Skip to main content

21.11.2018 | Editorial

Attenuation correction in multipinhole-CZT gamma camera

Differences in attenuation pattern in myocardial SPECT between CZT and conventional gamma cameras. Oddstig J, Martinsson E, Jogi J, Engblom H, Hindorf C. J Nucl Cardiol. 2018.

verfasst von: Valeria M. Moncayo, MD, James Galt, PhD

Erschienen in: Journal of Nuclear Cardiology

Einloggen, um Zugang zu erhalten

Excerpt

Practitioners of nuclear cardiology become familiar with their equipment. This is true for conventional SPECT systems as well as high-sensitivity systems with unique detectors and collimation. This editorial is prompted by an article by Oddstig et al that presents the differences in attenuation patterns between standard SPECT and a multi-pinhole CZT SPECT system.1
Literatur
2.
Zurück zum Zitat Piccinelli M, Garcia EV. Advances in single-photon emission computed tomography hardware and software. Cardiol Clin. 2016;34(1):1–11.CrossRef Piccinelli M, Garcia EV. Advances in single-photon emission computed tomography hardware and software. Cardiol Clin. 2016;34(1):1–11.CrossRef
3.
Zurück zum Zitat Slomka PJ, Berman DS, Germano G. New cardiac cameras: Single-photon emission CT and PET. Semin Nucl Med. 2014;44(4):232–51.CrossRef Slomka PJ, Berman DS, Germano G. New cardiac cameras: Single-photon emission CT and PET. Semin Nucl Med. 2014;44(4):232–51.CrossRef
4.
Zurück zum Zitat Esteves FP, et al. Diagnostic performance of low-dose rest/stress Tc-99m tetrofosmin myocardial perfusion SPECT using the 530c CZT camera: Quantitative vs visual analysis. J Nucl Cardiol. 2014;21(1):158–65.CrossRef Esteves FP, et al. Diagnostic performance of low-dose rest/stress Tc-99m tetrofosmin myocardial perfusion SPECT using the 530c CZT camera: Quantitative vs visual analysis. J Nucl Cardiol. 2014;21(1):158–65.CrossRef
5.
Zurück zum Zitat Esteves FP, et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16(6):927–34.CrossRef Esteves FP, et al. Novel solid-state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16(6):927–34.CrossRef
6.
Zurück zum Zitat Herzog BA, et al. Validation of CT attenuation correction for high-speed myocardial perfusion imaging using a novel cadmium-zinc-telluride detector technique. J Nucl Med. 2010;51(10):1539–44.CrossRef Herzog BA, et al. Validation of CT attenuation correction for high-speed myocardial perfusion imaging using a novel cadmium-zinc-telluride detector technique. J Nucl Med. 2010;51(10):1539–44.CrossRef
7.
Zurück zum Zitat Liu CJ, et al. A performance comparison of novel cadmium-zinc-telluride camera and conventional SPECT/CT using anthropomorphic torso phantom and water bags to simulate soft tissue and breast attenuation. Ann Nucl Med. 2015;29(4):342–50.CrossRef Liu CJ, et al. A performance comparison of novel cadmium-zinc-telluride camera and conventional SPECT/CT using anthropomorphic torso phantom and water bags to simulate soft tissue and breast attenuation. Ann Nucl Med. 2015;29(4):342–50.CrossRef
8.
Zurück zum Zitat Galt JR. New techniques, distinctive population, unique normal databases. J Nucl Cardiol. 2018;25(4):1338–41.CrossRef Galt JR. New techniques, distinctive population, unique normal databases. J Nucl Cardiol. 2018;25(4):1338–41.CrossRef
9.
Zurück zum Zitat Abbott BG, et al. Contemporary cardiac SPECT imaging-innovations and best practices: An information statement from the American Society of Nuclear Cardiology. J Nucl Cardiol. 2018;25(5):1847–60.CrossRef Abbott BG, et al. Contemporary cardiac SPECT imaging-innovations and best practices: An information statement from the American Society of Nuclear Cardiology. J Nucl Cardiol. 2018;25(5):1847–60.CrossRef
Metadaten
Titel
Attenuation correction in multipinhole-CZT gamma camera
Differences in attenuation pattern in myocardial SPECT between CZT and conventional gamma cameras. Oddstig J, Martinsson E, Jogi J, Engblom H, Hindorf C. J Nucl Cardiol. 2018.
verfasst von
Valeria M. Moncayo, MD
James Galt, PhD
Publikationsdatum
21.11.2018
Verlag
Springer International Publishing
Erschienen in
Journal of Nuclear Cardiology
Print ISSN: 1071-3581
Elektronische ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-018-01498-7

Herzstillstand nach Energy-Drinks

18.06.2024 Plötzlicher Herztod Nachrichten

Energy-Drinks können sich in Kombination mit anderen Risikofaktoren offenbar zu einem „perfekten Sturm“ zusammenbrauen, der schlimmstenfalls in einen plötzlichen Herzstillstand mündet. Sieben solcher Fälle schildert ein auf Rhythmusstörungen spezialisiertes US-Team.

Schleifendiuretikum ohne Herzinsuffizienz? Verordnung hinterfragen!

18.06.2024 Diuretika Nachrichten

Werden Schleifendiuretika häufig ohne sorgfältige Diagnostik verschrieben? Eine Kohortenstudie aus Schottland scheint darauf hinzudeuten.

Was eine zu kleine Klappe für die Langzeitprognose bedeutet

18.06.2024 Aortenklappenersatz Nachrichten

Stellt sich nach der Implantation eines biologischen Aortenklappenersatzes die Prothese als zu klein für den Patienten heraus, hat das offenbar nur geringe Auswirkungen auf Langzeitüberleben und Reoperationsrisiko; zumindest solange die effektive Öffnungsfläche über 0,65 cm2/m2 liegt.

Vorteile für Blutdruckselbstmanagement

18.06.2024 Hypertonie Nachrichten

Kontrollieren Hypertoniker ihren Blutdruck regelmäßig selbst, und passen sie entsprechend eigenständig ihre Antihypertensivadosis an, wird der Blutdruck um etwa 3 mmHg stärker gesenkt als unter dem üblichen ärztlichen Therapieplan.

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.