Skip to main content
Erschienen in: Surgical and Radiologic Anatomy 11/2018

15.05.2018 | Original Article

Available bone morphology and status of neural structures in the mandibular interforaminal region: three-dimensional analysis of anatomical structures

verfasst von: Duygu Goller Bulut, Emre Köse

Erschienen in: Surgical and Radiologic Anatomy | Ausgabe 11/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study aimed to clarify the size and morphology of the mandible and to determine state of neural structures for the planning of the dental implantation using cone-beam computerized tomography (CBCT).

Methods

Of the 252 patients, CBCT images of 48 selected patients were evaluated. The bone height and width were measured and the type of the mental portion of the inferior alveolar canal, the anterior loop length (ALL), the location of the incisive canal and lingual foramen were identified with cross-sectional and multiplane reformatted CBCT images. According to buccal and lingual concavities, the shape of the mandible is classified as type A, B and C.

Results

Bone widths of males were significantly higher than female (p < 0.05). The thickest part of the alveolar bone was measured in the middle triple zone (d line) and the thinnest part was measured in the area near the alveolar crest (b line). The most seen type of mandible was type B (45.8%) that mandible was concave on the buccal side. Bone heights had a tendency to increase towards to the anterior mandible, and bone height in male patients was slightly but not significantly greater than that in female patients. ALL was 4.2 ± 1.2 mm and visible incisive canal length on CBCT was 9.7 ± 3.8 mm.

Conclusion

CBCT assessment of morphological features of the alveolar bone and locations of nerve canals and foramina in the anterior-premolar region of mandible represent useful practical anatomical information about the interforaminal region. This information is the guide to the dentist before implant surgery.
Literatur
2.
Zurück zum Zitat Araki K, Maki K, Seki K, Sakamaki K, Harata Y, Sakaino R, Okano T, Seo K (2004) Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay™): system configuration and physical properties. Dentomaxillofac Radiol 33:51–59CrossRef Araki K, Maki K, Seki K, Sakamaki K, Harata Y, Sakaino R, Okano T, Seo K (2004) Characteristics of a newly developed dentomaxillofacial X-ray cone beam CT scanner (CB MercuRay™): system configuration and physical properties. Dentomaxillofac Radiol 33:51–59CrossRef
3.
Zurück zum Zitat Arzouman MJ, Otis L, Kipnis V, Levine D (1993) Observations of the anterior loop of the inferior alveolar canal. Int J Oral Maxillofac Implant 8:295–300 Arzouman MJ, Otis L, Kipnis V, Levine D (1993) Observations of the anterior loop of the inferior alveolar canal. Int J Oral Maxillofac Implant 8:295–300
4.
Zurück zum Zitat Benavides E, Rios HF, Ganz SD, An C-H, Resnik R, Reardon GT, Feldman SJ, Mah JK, Hatcher D, Kim M-J (2012) Use of cone beam computed tomography in implant dentistry: the International Congress of Oral Implantologists consensus report. Implant Dent 21:78–86CrossRef Benavides E, Rios HF, Ganz SD, An C-H, Resnik R, Reardon GT, Feldman SJ, Mah JK, Hatcher D, Kim M-J (2012) Use of cone beam computed tomography in implant dentistry: the International Congress of Oral Implantologists consensus report. Implant Dent 21:78–86CrossRef
6.
Zurück zum Zitat De Andrade E, Otomo-Corgel J, Pucher J, Ranganath KA (2001) The intraosseous course of the mandibular incisive nerve in the mandibular symphysis. Int J Periodontics Restor Dent 21:591–597 De Andrade E, Otomo-Corgel J, Pucher J, Ranganath KA (2001) The intraosseous course of the mandibular incisive nerve in the mandibular symphysis. Int J Periodontics Restor Dent 21:591–597
7.
Zurück zum Zitat De Vera JDC-P, Calleja JL-A, Burgueño-García M (2008) Hematoma of the floor of the mouth and airway obstruction during mandibular dental implant placement: a case report. Oral Maxillofac Surg 12:223–226CrossRef De Vera JDC-P, Calleja JL-A, Burgueño-García M (2008) Hematoma of the floor of the mouth and airway obstruction during mandibular dental implant placement: a case report. Oral Maxillofac Surg 12:223–226CrossRef
8.
Zurück zum Zitat Ferrare N, Leite AF, Caracas HCPM., de Azevedo RB, de Melo NS, de Souza Figueiredo PT (2013) Cone-beam computed tomography and microtomography for alveolar bone measurements. Surg Radiol Anat 35:495–502CrossRef Ferrare N, Leite AF, Caracas HCPM., de Azevedo RB, de Melo NS, de Souza Figueiredo PT (2013) Cone-beam computed tomography and microtomography for alveolar bone measurements. Surg Radiol Anat 35:495–502CrossRef
9.
Zurück zum Zitat Gahleitner A, Hofschneider U, Tepper G, Pretterklieber M, Schick S, Zauza K, Watzek G (2001) Lingual vascular canals of the mandible: evaluation with dental CT. Radiology 220:186–189CrossRef Gahleitner A, Hofschneider U, Tepper G, Pretterklieber M, Schick S, Zauza K, Watzek G (2001) Lingual vascular canals of the mandible: evaluation with dental CT. Radiology 220:186–189CrossRef
10.
Zurück zum Zitat Gala V, Tirpude V, Shah D, Doshi A, Fernandes G (2018) A retrospective cone beam computed tomography (CBCT) study of the assessment of the length of the anterior loop of the inferior alveolar nerve. Int J Sci Res Sci Technol 4(5):828–832 Gala V, Tirpude V, Shah D, Doshi A, Fernandes G (2018) A retrospective cone beam computed tomography (CBCT) study of the assessment of the length of the anterior loop of the inferior alveolar nerve. Int J Sci Res Sci Technol 4(5):828–832
11.
Zurück zum Zitat Hwang K, Lee WJ, Song YB, Chung IH (2005) Vulnerability of the inferior alveolar nerve and mental nerve during genioplasty: an anatomic study. J Craniofac Surg 16:10–14CrossRef Hwang K, Lee WJ, Song YB, Chung IH (2005) Vulnerability of the inferior alveolar nerve and mental nerve during genioplasty: an anatomic study. J Craniofac Surg 16:10–14CrossRef
12.
Zurück zum Zitat Jacobs R, Mraiwa N, VanSteenberghe D, Gijbels F, Quirynen M (2002) Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan. Dentomaxillofac Radiol 31:322–327CrossRef Jacobs R, Mraiwa N, VanSteenberghe D, Gijbels F, Quirynen M (2002) Appearance, location, course, and morphology of the mandibular incisive canal: an assessment on spiral CT scan. Dentomaxillofac Radiol 31:322–327CrossRef
14.
Zurück zum Zitat Kieser J, Kuzmanovic D, Payne A, Dennison J, Herbison P (2002) Patterns of emergence of the human mental nerve. Arch Oral Biol 47:743–747CrossRef Kieser J, Kuzmanovic D, Payne A, Dennison J, Herbison P (2002) Patterns of emergence of the human mental nerve. Arch Oral Biol 47:743–747CrossRef
15.
Zurück zum Zitat Kim ST, Hu K-S, Song W-C, Kang M-K, Park H-D, Kim H-J (2009) Location of the mandibular canal and the topography of its neurovascular structures. J Craniofac Surg 20:936–939CrossRef Kim ST, Hu K-S, Song W-C, Kang M-K, Park H-D, Kim H-J (2009) Location of the mandibular canal and the topography of its neurovascular structures. J Craniofac Surg 20:936–939CrossRef
16.
Zurück zum Zitat Kobayashi K, Shimoda S, Nakagawa Y, Yamamoto A (2004) Accuracy in measurement of distance using limited cone-beam computerized tomography. Int J Oral Maxillofac Implant 19 Kobayashi K, Shimoda S, Nakagawa Y, Yamamoto A (2004) Accuracy in measurement of distance using limited cone-beam computerized tomography. Int J Oral Maxillofac Implant 19
17.
Zurück zum Zitat Kuzmanovic DV, Payne AG, Kieser JA, Dias GJ (2003) Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implant Res 14:464–471CrossRef Kuzmanovic DV, Payne AG, Kieser JA, Dias GJ (2003) Anterior loop of the mental nerve: a morphological and radiographic study. Clin Oral Implant Res 14:464–471CrossRef
18.
Zurück zum Zitat Leung CC, Palomo L, Griffith R, Hans MG (2010) Accuracy and reliability of cone-beam computed tomography for measuring alveolar bone height and detecting bony dehiscences and fenestrations. Am J Orthod Dentofac Orthop 137:S109–S119CrossRef Leung CC, Palomo L, Griffith R, Hans MG (2010) Accuracy and reliability of cone-beam computed tomography for measuring alveolar bone height and detecting bony dehiscences and fenestrations. Am J Orthod Dentofac Orthop 137:S109–S119CrossRef
20.
Zurück zum Zitat Mardinger O, Chaushu G, Arensburg B, Taicher S, Kaffe I (2000) Anatomic and radiologic course of the mandibular incisive canal. Surg Radiol Anat 22:157–161CrossRef Mardinger O, Chaushu G, Arensburg B, Taicher S, Kaffe I (2000) Anatomic and radiologic course of the mandibular incisive canal. Surg Radiol Anat 22:157–161CrossRef
21.
Zurück zum Zitat Mischkowski RA, Pulsfort R, Ritter L, Neugebauer J, Brochhagen HG, Keeve E, Zöller JE (2007) Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104:551–559CrossRef Mischkowski RA, Pulsfort R, Ritter L, Neugebauer J, Brochhagen HG, Keeve E, Zöller JE (2007) Geometric accuracy of a newly developed cone-beam device for maxillofacial imaging. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 104:551–559CrossRef
22.
Zurück zum Zitat Molen AD (2010) Considerations in the use of cone-beam computed tomography for buccal bone measurements. Am J Orthod Dentofac Orthop 137:S130–S135CrossRef Molen AD (2010) Considerations in the use of cone-beam computed tomography for buccal bone measurements. Am J Orthod Dentofac Orthop 137:S130–S135CrossRef
23.
Zurück zum Zitat Mraiwa N, Jacobs R, Moerman P, Lambrichts I, van Steenberghe D, Quirynen M (2003) Presence and course of the incisive canal in the human mandibular interforaminal region: two-dimensional imaging versus anatomical observations. Surg Radiol Anat 25:416–423CrossRef Mraiwa N, Jacobs R, Moerman P, Lambrichts I, van Steenberghe D, Quirynen M (2003) Presence and course of the incisive canal in the human mandibular interforaminal region: two-dimensional imaging versus anatomical observations. Surg Radiol Anat 25:416–423CrossRef
24.
Zurück zum Zitat Panjnoush M, Rabiee ZS, Kheirandish Y (2016) Assessment of location and anatomical characteristics of mental foramen, anterior loop and mandibular incisive canal using cone beam computed tomography. J Dent (Tehran) 13:126–132 Panjnoush M, Rabiee ZS, Kheirandish Y (2016) Assessment of location and anatomical characteristics of mental foramen, anterior loop and mandibular incisive canal using cone beam computed tomography. J Dent (Tehran) 13:126–132
25.
Zurück zum Zitat Polland KE, Munro S, Reford G, Lockhart A, Logan G, Brocklebank L, McDonald SW (2001) The mandibular canal of the edentulous jaw. Clin Anat 14:445–452CrossRef Polland KE, Munro S, Reford G, Lockhart A, Logan G, Brocklebank L, McDonald SW (2001) The mandibular canal of the edentulous jaw. Clin Anat 14:445–452CrossRef
27.
Zurück zum Zitat Quirynen M, Mraiwa N, Van Steenberghe D, Jacobs R (2003) Morphology and dimensions of the mandibular jaw bone in the interforaminal region in patients requiring implants in the distal areas. Clin Oral Implant Res 14:280–285CrossRef Quirynen M, Mraiwa N, Van Steenberghe D, Jacobs R (2003) Morphology and dimensions of the mandibular jaw bone in the interforaminal region in patients requiring implants in the distal areas. Clin Oral Implant Res 14:280–285CrossRef
29.
Zurück zum Zitat Rosenquist B (1996) Is there an anterior loop of the inferior alveolar nerve? Int J Periodontics Restor Dent 16 Rosenquist B (1996) Is there an anterior loop of the inferior alveolar nerve? Int J Periodontics Restor Dent 16
30.
Zurück zum Zitat Sahman H, Sisman Y (2016) Anterior loop of the inferior alveolar canal: a cone-beam computerized tomography study of 494 cases. J Oral Implantol 42:333–336CrossRef Sahman H, Sisman Y (2016) Anterior loop of the inferior alveolar canal: a cone-beam computerized tomography study of 494 cases. J Oral Implantol 42:333–336CrossRef
32.
Zurück zum Zitat Solar P, Ulm C, Frey G, Matejka M (1994) A classification of the intraosseous paths of the mental nerve. Int J Oral Maxillofac Implant 9:339–344 Solar P, Ulm C, Frey G, Matejka M (1994) A classification of the intraosseous paths of the mental nerve. Int J Oral Maxillofac Implant 9:339–344
33.
Zurück zum Zitat Srebrzyńska-Witek A, Koszowski R, Różyło-Kalinowska I (2018) Relationship between anterior mandibular bone thickness and the angulation of incisors and canines—a CBCT study. Clin Oral Investig 22:1567–1578CrossRef Srebrzyńska-Witek A, Koszowski R, Różyło-Kalinowska I (2018) Relationship between anterior mandibular bone thickness and the angulation of incisors and canines—a CBCT study. Clin Oral Investig 22:1567–1578CrossRef
34.
Zurück zum Zitat Tepper G, Hofschneider UB, Gahleitner A, Ulm C (2001) Computed tomographic diagnosis and localization of bone canals in the mandibular interforaminal region for prevention of bleeding complications during implant surgery. Int J Oral Maxillofac Implant 16:68–72 Tepper G, Hofschneider UB, Gahleitner A, Ulm C (2001) Computed tomographic diagnosis and localization of bone canals in the mandibular interforaminal region for prevention of bleeding complications during implant surgery. Int J Oral Maxillofac Implant 16:68–72
35.
Zurück zum Zitat Timock AM, Cook V, McDonald T, Leo MC, Crowe J, Benninger BL, Covell DA (2011) Accuracy and reliability of buccal bone height and thickness measurements from cone-beam computed tomography imaging. Am J Orthod Dentofac Orthop 140:734–744CrossRef Timock AM, Cook V, McDonald T, Leo MC, Crowe J, Benninger BL, Covell DA (2011) Accuracy and reliability of buccal bone height and thickness measurements from cone-beam computed tomography imaging. Am J Orthod Dentofac Orthop 140:734–744CrossRef
36.
Zurück zum Zitat Tomomi H, Tsukasa S, Kenji S, Tomohiro O (2004) Radiologic measurements of the mandible: a comparison between CT-reformatted and conventional tomographic images. Clin Oral Implant Res 15:226–232CrossRef Tomomi H, Tsukasa S, Kenji S, Tomohiro O (2004) Radiologic measurements of the mandible: a comparison between CT-reformatted and conventional tomographic images. Clin Oral Implant Res 15:226–232CrossRef
37.
Zurück zum Zitat Uchida Y, Noguchi N, Goto M, Yamashita Y, Hanihara T, Takamori H, Sato I, Kawai T, Yosue T (2009) Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg 67:744–750CrossRef Uchida Y, Noguchi N, Goto M, Yamashita Y, Hanihara T, Takamori H, Sato I, Kawai T, Yosue T (2009) Measurement of anterior loop length for the mandibular canal and diameter of the mandibular incisive canal to avoid nerve damage when installing endosseous implants in the interforaminal region: a second attempt introducing cone beam computed tomography. J Oral Maxillofac Surg 67:744–750CrossRef
38.
Zurück zum Zitat Watanabe H, Abdul MM, Kurabayashi T, Aoki H (2010) Mandible size and morphology determined with CT on a premise of dental implant operation. Surg Radiol Anat 32:343–349CrossRef Watanabe H, Abdul MM, Kurabayashi T, Aoki H (2010) Mandible size and morphology determined with CT on a premise of dental implant operation. Surg Radiol Anat 32:343–349CrossRef
Metadaten
Titel
Available bone morphology and status of neural structures in the mandibular interforaminal region: three-dimensional analysis of anatomical structures
verfasst von
Duygu Goller Bulut
Emre Köse
Publikationsdatum
15.05.2018
Verlag
Springer Paris
Erschienen in
Surgical and Radiologic Anatomy / Ausgabe 11/2018
Print ISSN: 0930-1038
Elektronische ISSN: 1279-8517
DOI
https://doi.org/10.1007/s00276-018-2039-8

Weitere Artikel der Ausgabe 11/2018

Surgical and Radiologic Anatomy 11/2018 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.