Abstract

Introduction

We present a catheter technique that utilizes a 5F system for the purpose of balloon-assisted coiling in the setting of intracranial aneurysms.

Methods

A standard 5F short sheath is placed in the common femoral artery, and a 5F diagnostic catheter is placed through the sheath and used for selective vessel angiography. When endovascular intervention is pursued, the diagnostic catheter is placed in the appropriate vessel and systemic heparinization is ensured. Over an exchange length wire, the 5F vertebral catheter and 5F short sheath are exchanged for a 5F Shuttle (Cook) sheath. We then routinely place a 10, 14 or 18 microcatheter over an appropriately gauged microguidewire into the aneurysm. As needed, balloon catheters are then placed across the neck of the aneurysm for remodeling purposes. During the course of the procedure, control angiography is performed through the Shuttle sheath. Following the placement of coils, the microcatheter and balloon catheter are removed and a final biplane image is obtained via the 5F Shuttle sheath.

Results

This technique has been employed in 15 patients who required balloon-assisted coiling of an intracranial aneurysm. There were no technical difficulties or arterial access site complications from the procedures. Catheter mobility and torque were not affected, nor was the quality of our imaging.

Conclusion

We conclude that this small-diameter system provides ample “room” for catheter placement and interventional treatment while reducing the known risks of postprocedural complications. Angiographic images remain excellent and are comparable to those obtained by larger catheters.
Literatur
1.
Zurück zum Zitat Lilly MP, Reichman W, Sarazen AA Jr et al (1990) Anatomic and clinical factors associated with complications of transfemoral arteriography. Ann Vasc Surg 4:264–269PubMedCrossRef Lilly MP, Reichman W, Sarazen AA Jr et al (1990) Anatomic and clinical factors associated with complications of transfemoral arteriography. Ann Vasc Surg 4:264–269PubMedCrossRef
2.
Zurück zum Zitat Kohli RS, Vetrovec GW, Lewis SA et al (1989) Study of the performance of 5 French and 7 French catheters in coronary angiography: a functional comparison. Cathet Cardiovasc Diagn 18:131–135PubMedCrossRef Kohli RS, Vetrovec GW, Lewis SA et al (1989) Study of the performance of 5 French and 7 French catheters in coronary angiography: a functional comparison. Cathet Cardiovasc Diagn 18:131–135PubMedCrossRef
3.
Zurück zum Zitat Morgan R, Belli A-M (2003) Current treatment methods for postcatheterization pseudoaneurysms. J Vasc Interv Radiol 14:697–710PubMed Morgan R, Belli A-M (2003) Current treatment methods for postcatheterization pseudoaneurysms. J Vasc Interv Radiol 14:697–710PubMed
4.
Zurück zum Zitat Luzardo GD, Ross IB, Gal G (2006) Balloon-assisted coiling through a single 6F guiding catheter. AJNR Am J Neuroradiol 27:190–191PubMed Luzardo GD, Ross IB, Gal G (2006) Balloon-assisted coiling through a single 6F guiding catheter. AJNR Am J Neuroradiol 27:190–191PubMed
Metadaten
Titel
Balloon-assisted coiling through a 5-French system
verfasst von
J. Bradley White
Kennith F. Layton
David F. Kallmes
Harry J. Cloft
Publikationsdatum
01.02.2007
Verlag
Springer-Verlag
Erschienen in
Neuroradiology / Ausgabe 2/2007
Print ISSN: 0028-3940
Elektronische ISSN: 1432-1920
DOI
https://doi.org/10.1007/s00234-006-0163-3

Weitere Artikel der Ausgabe 2/2007

Neuroradiology 2/2007 Zur Ausgabe

Leitlinien kompakt für die Neurologie

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.