Abstract

Accumulating evidence shows that ultrasound (US) guidance improves effectiveness and safety of central venous catheter (CVC) placement. Several international guidelines therefore recommend the use of US for placement of CVCs. However, surveys show that the landmark-based technique is still widely used, while the percentage of physicians using US is increasing less than expected. The goal of this study was to investigate current practice for central venous catheterization in anaesthesiology and intensive care in the Netherlands, identify barriers for further implementation of US guidance and to evaluate whether personality traits are associated with the choice of technique. We conducted a web-based national survey, distributed among members of the Dutch societies of anaesthesiology (NVA) and intensive care (NVIC). The survey contained questions regarding physician and hospital characteristics, frequency of US use and reasons for use or non-use, as well as the NEO-FFI-3, a validated, translated questionnaire to characterize personality traits according to the ‘Big Five’ concept. Response rate was 22% (506/2291), of which 400 had also the personality questionnaire complete. Ultrasound guidance was used always or almost always in 68%; barriers for US use were working in a non-academic non-teaching hospital, providing cardiac anaesthesia and more years of physician experience. Reasons for not using US were perceived lack of benefit, increased procedure time, lack of US equipment and fear of loss of landmark technique skills. 13% of respondents had never experienced a complication during CVC placement, and 67% knew of a complication occurring the past year at their department. Ultrasound was thought not to be able to prevent the complication in half of these cases. Of the personality traits, only neuroticism and extraversion showed a minor positive association with US guidance. A majority of anaesthesiologists and intensivists uses US guidance for CVC placement, but a significant proportion of physicians still prefers the landmark technique. Most arguments from respondents against US guidance can be challenged. Personality traits most likely do not play a major role in the acceptance of US guidance for central venous catheterization. A potential intervention to increase US use could be formalizing local hospital policies mandating compliance with US guidance. Future research can perhaps focus on cognitive biases that currently limit more widespread use of US guidance.
Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1007/​s10877-018-00246-z) contains supplementary material, which is available to authorized users.

1 Introduction

Central venous catheters (CVC) are frequently placed in patients who are scheduled for major surgery or admitted to the intensive care unit (ICU). Traditionally, a landmark based technique is used but complications during placement occur in up to 15% of procedures, ranging from relatively mild such as local hematoma or arterial puncture to more serious adverse events such as pneumothorax, retroperitoneal hematoma or cerebral vascular accidents [1]. Ultrasound (US) guidance has consistently shown to not only improve success rate of procedures, but also to decrease complications [2, 3]. The benefits are most prominent for the jugular vein, but also for the subclavian or femoral vein evidence of increasing safety is accumulating [47]. Several national societies issued guidelines recommending ultrasound guidance during placement of CVC [810], already dating back to 2002 when the National Institute of Clinical Excellence (NICE) recommended US guidance in the United Kingdom. Furthermore, implementation of a local guideline advocating the use of US or the departmental switch from landmark to US results in a reduction of complications [11, 12]. However, previous surveys show that a significant proportion (50–60%) of physicians still prefers the landmark approach in daily practice [1315]. The most cited reasons for not using ultrasound are lack of benefit, not receiving education in US guidance or lack of US equipment [1315]. Most of these arguments do not hold anymore as US equipment is ubiquitous available, benefit is proven and training opportunities are universally offered.
Implementations of guidelines can be hampered not only by external barriers but attitudinal aspects also play a role [16]. Furthermore, medical judgment and decisions may be influenced by cognitive errors (biases) or personality traits [17]. Among personality traits, extraversion and neuroticism are known to be negatively correlated with work related safety behaviour [18]. As the use of US guidance can be regarded as a safety enhancing procedure, there may be a relationship between physicians’ personality traits and their adoption of US guidance for vascular access. The most frequently used model to describe personality traits is the ‘Big Five’ concept by Costa and McCrae, allowing rapid characterization of traits into five domains: neuroticism, extraversion, agreeableness, openness to experience and conscientiousness [19].
Hence, the aim of this study was twofold: first, to reassess current practice in central venous access by Dutch anaesthesiologists and intensivists and their attitude regarding US guidance. The second objective was to evaluate the possible association of physicians’ personality traits with clinical practice.

2 Methods

An invitation to participate in a web-based survey was sent to all members (including residents) of the Dutch Society of Anaesthesiology (NVA) and to the Dutch Society for Intensive Care (NVIC) using the Qualtrics platform (Qualtrics, Provo, UT, USA). Data was collected from June till September 2017.
The survey was based on previous studies concerning ultrasound guidance in vascular access, with questions regarding personal preferences and attitudes [1315]. (Supplemental Digital Content 1) For anaesthesiologists, questions regarding US use during regional anaesthesia procedures were added to compare this to CVC insertion practice and assess departmental availability of US equipment.
Personality traits were assessed using the Dutch translation of the revised NEO-FFI-3 [20]. (Supplemental Digital Content 2) The NEO-FFI-3 consists of a 60 item questionnaire assessing the ‘Big Five’ personality traits: neuroticism (N), the tendency to experience emotional distress; extraversion (E), or the tendency to experience positive emotions; conscientiousness (C), the manner of being careful or vigilant; openness to experience (O), or (intellectual) curiosity; and agreeableness (A), being a pro-social person [19]. The items are rated on a five point Likert scale, from totally disagree to totally agree.
The primary outcomes of the study were the frequency of landmark versus US guided CVC placement, and whether physicians’ personality traits were associated with the preference for one or the other technique.
Secondary outcomes were attitudes and perceived barriers regarding the use of US guidance.

2.1 Statistical analysis

The collected data was directly exported from the Qualtrics platform to a SPSS datafile.
Demographical data were described using mean and standard deviation (SD) for numerical variables and numbers or percentages for categorical variables. Unpaired t-test or Mann–Whitney-U test, and Chi2 tests were performed to test differences between groups.
To investigate the relationship between personality traits and ultrasound guidance, univariate and multivariate logistic regression was performed. Therefore, the answer regarding usage of US on the five-point scale was transformed to a binary variable; ‘Always’ and ‘Usually’ were combined as ‘frequent use’. ‘Sometimes’, ‘Rarely’ and ‘Never’ were grouped into ‘infrequent use’.
A p value of less than 0.05 was considered statistically significant. All statistical analyses were performed using SPSS Statistics Version 24 (IBM Corp., Armonk, NY, USA).

3 Results

A total of 2291 invitations to participate in the survey were sent to consultants and residents in anaesthesiology and intensive care. Overall response rate was 22%, which was divided among 354 anaesthesiologists (23, 6%), 87 residents anaesthesiology (20, 2%) and 156 intensive care physicians (16%) Further details of the respondents are displayed in (Table 1). The median of duration of practice was 11 years. Most respondents (> 80%) work in an academic or teaching hospital setting.
Table 1
Demographic variables of respondents
 
N
%
Gender
 Male
287
56.7
Years consultant
Median
IQR
 
11 (0–38)
5–19
Physician type
 Anesthesiologist
272
53.8
 Resident Anesthesiology
86
17.0
 Anesthesiologist-Intensivist
72
14.2
 Intensivist (other specialty)
66
13.0
 Fellow ICU
10
2.0
Cardiac anesthesia
 Yes
51
14.6
Hospital type (consultants)
 Academic
145
34.4
 Teaching
193
45.8
 Community
83
19.7
Central venous catheters placed annually
 0
9
1.8
 1–25 (< 2 monthly)
186
36.8
 25–49 (2–4 monthly)
162
32.0
 49–100 (1–2 weekly)
84
16.6
 > 100 (> 2 weekly)
65
12.8
Peripheral nerve blocks performed weekly
 0
50
13.9
 1–5
184
51.0
 5–15
96
26.6
 > 15
31
8.6

3.1 Central venous catheterization

Only nine respondents didn’t perform central venous cannulation. About two-thirds (68.6%) of the respondents always or almost always use US guidance during CVC insertion. (Fig. 1a, b) (Table 2) The most cited reason for not using US guidance was an increase in procedure time (35.8%). Other barriers are the loss of landmark skills (28.6%), lack of US equipment (22.7%) and no perceived benefit of US above the landmark technique 20.9%). On the other hand, higher success rate, less complications and an expected difficult puncture were arguments for the use of US guidance in over half of respondents. When US is used, 13.6% of respondents only locate the vein pre-procedural but the actual puncture is without US guidance. Of the real time users, roughly half prefers in-plane and the other half an out of plane approach. Most physicians experienced at least one complication during CVC placement during their career, of which arterial puncture (69.8%) was the most frequent. During the past year, 67% of respondents recall a complication occurring at their department. In their opinion in half of those cases, US guidance could have prevented the complication. However, in 43% the complication did take place despite using US guidance. An emergency situation where US equipment was not readily available was experienced by 17.2% of the population.
Table 2
Description of US guidance for central venous catheter placement
Use of US guidance
n
%
 Always
185
36.6
 Usually
162
32.0
 Sometimes
88
17.4
 Rarely
51
10.1
 Never
20
4.0
Reasons for not using US guidance (n = 335)
 More time consuming than landmark technique
115
35.8
 Loss of skills (landmark technique)
92
28.6
 Lack of US equipment
73
22.7
 No perceived benefit of US compared to landmarks
67
20.9
 Localization (subclavian/femoral vein)
33
10.3
 No adequate training/education
25
7.8
 Other
36
11.2
Reasons for using US guidance (n = 486)
 Less complications
326
67.1
 Higher success rate
286
58.8
 Expected difficulty (e.g. obesity)
252
51.9
 Education
184
37.9
 Coagulation abnormalities
173
35.6
 After landmark failed
10
2.1
 Other
60
12.3
US technique (n = 481)
 US assisted (anatomic scan, no real time guidance)
69
13.6
 Real time out of plane
216
42.7
 Real time in plane
196
38.7
Local protocol for CVC insertion
 Yes
349
69.0
  Recommending US guidance
264
52.2
 No
71
14.0
Did you ever have a complication during CVC insertion
 Never
68
13.1
 Arterial punction
363
69.8
 Arterial dilation/CVC insertion
70
13.5
 Pneumothorax
171
32.9
 Hematothorax
26
5.0
 Retroperitoneal hematoma
13
2.5
 Other
37
7.1
A complication during CVC insertion did occur last year
 Yes
338
67.3
  Preventable with US guidance
 Probably
177
52.5
 Absolutely not
15
4.5
 The complication did occur under US guidance
145
43.0
Experienced emergency situation without US available immediately
 Yes
86
17.2
Would you agree with a national guideline recommending US guidance
  
 Yes
305
60.3
 Yes, but only for the jugular vein
58
11.5
 Yes, but only for residents
18
3.6
 No
123
24.3

3.2 Personality traits

Complete NEO-FFI-3 inventories were available for 421 respondents. The average scores for males and females are displayed in (Table 3) with the normal references. Female respondents scored higher on the neuroticism scale, but were also more agreeable compared to male respondents. Overall, the respondents scores on all domains were slightly higher than in the general population, except for neuroticism where the scores were just below average. Among specialists, providing cardiac anesthesia was also associated with lower scores on the neuroticism scale.
Table 3
Personality traits of respondents
 
All
Male
Female
p
Mean
Range
SD
Mean
Range
SD
Mean
Range
SD
Neuroticism
27.2
12–51
7.0
26.0
12–46
6.6
28.6
13–51
7.2
< 0.001
Extraversion
43.2
19–56
5.5
43.0
25–56
5.3
43.5
19–56
5.7
0.386
Openness
40.8
24–57
5.7
41.1
24–56
5.2
40.5
26–57
6.1
0.291
Agreeableness
43.2
24–55
4.4
42.4
29–55
4.4
44.2
24–54
4.1
< 0.001
Conscientioussness
47.5
28–59
4.8
47.3
30–59
5.1
47.6
28–59
4.4
0.517

3.3 Regression analysis

We found that both the personality traits neuroticism and extraversion were positively associated with the use of US guidance during CVC placement. The correlation coefficients are displayed in (Table 4). Univariate logistic regression showed significant relationships between not frequently using US and working in a non-academic hospital, placing > 100 CVC’s yearly, male gender, more years of experience, being involved in cardiac anaesthesia and not having a departmental protocol requiring US use. After multivariate analysis, only working in a non-teaching community hospital and providing cardiac anaesthesia were significantly associated with not regularly using US. The results of the logistic regression are displayed in Table 5.
Table 4
Regression analysis of personality traits with the use of US guidance during CVC placement
 
OR
95% CI
p
Neuroticism
1.047
1.008–1.087
0.017
Extraversion
1.094
1.044–1.145
0.000
Openness
0.985
0.947–1.025
0.451
Agreeableness
1.044
0.994–1.096
0.088
Conscientiousness
0.953
0.905–1.004
0.069
Table 5
Univariate and multivariate logistic regression
 
Univariate
Multivariate
OR
95% C.I
p
OR
95% C.I
p
Type of hospital
 Academic
   
0.00
   
0.00
 Community, teaching
2.38
1.45
3.91
0.00
1.59
0.75
3.39
0.23
 Community, non-teaching
4.77
2.64
8.60
0.00
4.99
1.92
12.98
0.00
Gender
 Male
1.83
1.24
2.71
0.00
1.29
0.68
2.44
0.43
Number of CVCs last year
 1–25 (< 2 monthly)
   
0.00
   
0.70
 25–49 (2–4 monthly)
1.14
0.71
1.83
0.58
1.43
0.38
5.360
0.60
 50–100 (1–2 weekly)
0.99
0.55
1.78
0.98
0.90
0.29
3.42
0.88
 > 100 (> 2 weekly)
3.07
1.71
5.51
0.00
1.24
0.36
4.32
0.74
Specialty
 Anesthesia
0.76
0.46
1.24
0.27
0.70
0.31
1.57
0.39
Years experience
 Less than 5 years
0.23
0.15
0.36
0.00
0.51
0.20
1.29
0.15
 Less than 10 years
0.32
0.22
0.47
0.00
0.97
0.35
2.63
0.94
 Less than 15 years
0.40
0.26
0.60
0.00
0.81
0.33
2.00
0.65
Cardiac anesthesia?
3.96
2.11
7.44
0.00
5.89
1.69
20.49
0.01
Department protocol
 Yes
1.01
0.82
1.25
0.93
    
 US recommended
0.17
0.10
0.28
0.00
0.00
0.22
0.11
0.44
OR for not using US during CVC placement

4 Discussion

Although the number of physicians regularly using US has been gradually increasing since the publication of the NICE guidelines in 2002, still 20–50% of CVC’s is placed using the landmark technique [1315, 21]. We found that roughly one-third of anaesthesiologists and intensivists in the Netherlands still rely on the landmark technique, despite compelling evidence claiming the superiority of US guidance. This is the first study looking at physicians’ personality traits and their influence on medical decision making concerning US guidance for central venous access.
Factors associated with infrequent use of US guidance were: working in a non-teaching hospital, increasing years of experience and providing cardiac anaesthesia. Gender, number of central vascular procedures performed or type of specialization were not correlated after multivariate logistic regression.
Most cited arguments against the use of US were availability of ultrasound equipment, increase in procedure time, lack of perceived benefit, and loss of (landmark) skills. However, most anaesthesiology or critical care departments own multiple US machines [22]. Moreover, peripheral nerve blocks are performed with US guidance in > 95% by respondents in this study. The present survey shows that cardiac anaesthesiologists are the least frequent users of ultrasound for central venous access. This is a surprising finding, as current practice is that an ultrasound machine is permanent in the cardiac operating room.
Regarding the perceived extra procedural time needed for US guidance, actually the average time decreases using US as multiple misguided punctures will be prevented. But even more important, less skin breaks can decrease complications such as catheter related bloodstream infections [12, 2325].
Some respondents felt the landmark technique should still be taught, for occasions where US equipment would not be immediately available. First, recognizing external landmarks before continuing the procedure under US guidance is possible, even allowing for better anatomical knowledge or identifying anatomical variations [23, 26]. Interestingly, a significant portion of physicians uses US when landmark technique fails, implicating that using US from the start of the procedure may increase its success ratio.
A complication during catheter placement occurred at the department of 67% of respondents the past year, of which 50% believed the complication was probably preventable with US guidance. Remarkably, 43% of those complications occurred despite using US. An explanation could be not using a real time technique, or known dangers of the out of plane technique as the needle tip is not constantly visualized in this approach, increasing the risk of damaging structures not visible in the US screen. Because of the anonymous design of the survey, no conclusions about departmental protocols and occurrence of complications can be made.
We hypothesized that personality traits may explain the preference for US or landmark technique. We used the ‘Big Five’ model, an established and validated method to characterize personality in five basic traits: neuroticism (or emotional instability), extraversion, agreeableness, openness to experience and conscientiousness [19]. We expected physicians with high scores on extraversion and neuroticism to prefer the landmark technique, as those traits are negatively related to safety related work behaviour [18]. Equally, conscientiousness, agreeableness and openness are linked with a tendency to try new things and to be more precise and careful, so we hypothesized these traits to be associated with US guidance. Contradictory to our hypotheses, we found a very small association between both neuroticism and extraversion and the use of US. For other personality traits we found no effect. When looking at the scores for neuroticism, all respondents have a low score on this scale when compared to the general population. From other scientific disciplines, it is known that a certain degree of neuroticism is associated with more risk aversive behaviour. Put it another way, too little neuroticism can maybe cause an physician underestimate risks and therefore be more resilient in accepting US guidance as a risk lowering strategy for CVC placement are probably turning worries or anxiety into positive behaviour.
Individuals who score higher on neuroticism are known to exhibit risk averse behaviour, especially when also scoring high on conscientiousness [27, 28]. Conversely, openness and extraversion are associated with more risk taking. However, in medicine this relationship has not been studied before [2931].
Our study has several limitations. The overall response rate of 22% is lower than previous surveys. The past years, a trend in declining response rates of web-based surveys of health care professionals is observed [32, 33]. A proven strategy to improve response rates is a follow up reminder after the initial invitation to non-responders [32, 34]. However, during its distribution many physicians had objections against the personality questionnaire and did not finish this part of the survey. Maybe we struck a nerve on this subject, but we decided not to send the reminder. Moreover, we hypothesize echo enthusiast physicians are more likely to complete the survey, so actual use of US guidance may be lower than we found.
We did not differentiate between locations for CVC placement. The evidence is most clear for the jugular vein, but the principle to visualize needle and target is valid for every location. Indeed, only a minority of respondents cited the location as a reason for not using US.
Our study still leaves some questions unanswered. We demonstrated that US guidance for CVC placement is still not adopted universally despite several guidelines advocating its use. Cabana identified barriers to implement guidelines such as lack of awareness, lack of agreement, external barriers (availability of equipment), the same as we found in our study [35]. In psychological literature, such barriers affecting judgment are called cognitive biases, for instance inertia of previous practice or the ‘status quo’ bias [36, 37]. Another bias occurs when adverse events (e.g. catheter related bloodstream infections) are not directly noted or not communicated back, which is interpreted as positive feedback [38]. Likewise, the ‘overconfidence’ bias, or the ‘above average effect’ results from clinicians (and all other human beings) considering themselves to perform better than their peers, and this confidence is misperceived as competence [39, 40]. Those biases are difficult to overcome by just presenting evidence, as facts that challenge existing assumptions are usually ignored by individuals if they conflict with their personal experiences [41]. Also, physicians are less willing to change their practice when confronted by others [40]. To address all barriers, a combination of education, conversation and skills for motivational change is necessary [42]. Future research and interventions aimed at increasing US guidance for CVC insertion should address those cognitive biases. But despite the reluctancy to accept guidelines, hospitals with a departmental protocol for CVC placement that recommend US guidance had a significantly higher proportion of physicians relying on US guidance.. Additionally, a future scenario with an expanded US-only protocol where X-ray is substituted by US for confirmation of correct central line position and ruling out pneumothorax after insertion, could further lower the barriers for US guidance for placement. However, as availability and acquaintance with US equipment in the cardiac ORs does not seem to have a positive effect, the overall effect of a US-only protocol remains to be seen.
In conclusion, the use of ultrasound guidance for placement of CVCs in the Netherlands has slightly increased the past years but a significant proportion of physicians continues using the landmark technique. Personality traits do not seem to play an important role in the acceptance of ultrasound. Indeed, using landmark technique most CVC’s are placed without adverse events. However, the procedure is performed frequently, possible complications are associated with significant morbidity (and even mortality) and a proven strategy to minimize these complications is directly available. As local guidelines show to increase its use, we encourage department leaders to mandate US guidance in central venous access protocols in order to help the removal of the last barriers for universal use of US guidance.

Compliance with ethical standards

Conflict of interest

This investigator-initiated work is part of a PhD study (H.J.S.), which is embedded in a research consortium of the Catharina Hospital Eindhoven, the University of Technology Eindhoven and Philips research Eindhoven (IMPULS project). RAB and HHMK receive consultancy fees for Philips research Eindhoven. All authors declared that they have no conflict of interest.
OpenAccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Anhänge

Electronic supplementary material

Below is the link to the electronic supplementary material.
Literatur
1.
Zurück zum Zitat Lennon M, Zaw NN, Pöpping DM, Wenk M. Procedural complications of central venous catheter insertion. Minerva Anestesiol. 2012;78:1234–40.PubMed Lennon M, Zaw NN, Pöpping DM, Wenk M. Procedural complications of central venous catheter insertion. Minerva Anestesiol. 2012;78:1234–40.PubMed
2.
Zurück zum Zitat Brass P, Hellmich M, Kolodziej L, Schick G, Af S, Brass P, et al. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization. Cochrane Database Syst Rev. 2015;1:CD011447.PubMed Brass P, Hellmich M, Kolodziej L, Schick G, Af S, Brass P, et al. Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization. Cochrane Database Syst Rev. 2015;1:CD011447.PubMed
3.
Zurück zum Zitat Wu S-Y, Ling Q, Cao L-H, Wang J, Xu M-X, Zeng W-A. Real-time two-dimensional ultrasound guidance for central venous cannulation. Anesthesiology 2013;57:321. Wu S-Y, Ling Q, Cao L-H, Wang J, Xu M-X, Zeng W-A. Real-time two-dimensional ultrasound guidance for central venous cannulation. Anesthesiology 2013;57:321.
4.
Zurück zum Zitat Lalu MM, Fayad A, Ahmed O, Bryson GL, Fergusson DA, Barron CC, et al. Ultrasound-guided subclavian vein catheterization: a systematic review and meta-analysis. Crit Care Med. 2015;43:1498–507.PubMedCrossRef Lalu MM, Fayad A, Ahmed O, Bryson GL, Fergusson DA, Barron CC, et al. Ultrasound-guided subclavian vein catheterization: a systematic review and meta-analysis. Crit Care Med. 2015;43:1498–507.PubMedCrossRef
5.
Zurück zum Zitat Saugel B, Scheeren TWL, Teboul J-L. Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice. Crit Care Crit Care. 2017;21:225.PubMedCrossRef Saugel B, Scheeren TWL, Teboul J-L. Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice. Crit Care Crit Care. 2017;21:225.PubMedCrossRef
6.
Zurück zum Zitat Brass P, Hellmich M, Kolodziej L, Schick G, Smith AF. Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization. Cochrane Database Syst Rev. 2015;1:CD011447.PubMed Brass P, Hellmich M, Kolodziej L, Schick G, Smith AF. Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization. Cochrane Database Syst Rev. 2015;1:CD011447.PubMed
7.
Zurück zum Zitat Powell JT, Mink JT, Nomura JT, Levine BJ, Jasani N, Nichols WL, et al. Ultrasound-guidance can reduce adverse events during femoral central venous cannulation. J Emerg Med. 2014;46:519–24.PubMedCrossRef Powell JT, Mink JT, Nomura JT, Levine BJ, Jasani N, Nichols WL, et al. Ultrasound-guidance can reduce adverse events during femoral central venous cannulation. J Emerg Med. 2014;46:519–24.PubMedCrossRef
8.
Zurück zum Zitat Lamperti M, Bodenham AR, Pittiruti M, Blaivas M, Augoustides JG, Elbarbary M, et al. International evidence-based recommendations on ultrasound-guided vascular access. Intensive Care Med. 2012;38:1105–17.PubMedCrossRef Lamperti M, Bodenham AR, Pittiruti M, Blaivas M, Augoustides JG, Elbarbary M, et al. International evidence-based recommendations on ultrasound-guided vascular access. Intensive Care Med. 2012;38:1105–17.PubMedCrossRef
9.
Zurück zum Zitat Rupp S, Apfelbaum JL, Blitt C, Caplan RA, Connis RT, Domino KB, et al. Practice guidelines for central venous access: a report by the American Society of Anesthesiologists task force on central venous access. Anesthesiology 2012;116:539–73.PubMedCrossRef Rupp S, Apfelbaum JL, Blitt C, Caplan RA, Connis RT, Domino KB, et al. Practice guidelines for central venous access: a report by the American Society of Anesthesiologists task force on central venous access. Anesthesiology 2012;116:539–73.PubMedCrossRef
10.
Zurück zum Zitat Bodenham A, Babu S, Bennett J, Binks R, Fee P, Fox B, et al. Association of anaesthetists of great Britain and Ireland: safe vascular access 2016. Anaesthesia 2016;71:573–85.CrossRef Bodenham A, Babu S, Bennett J, Binks R, Fee P, Fox B, et al. Association of anaesthetists of great Britain and Ireland: safe vascular access 2016. Anaesthesia 2016;71:573–85.CrossRef
11.
Zurück zum Zitat Wigmore TJ, Smythe JF, Hacking MB, Raobaikady R, MacCallum NS. Effect of the implementation of NICE guidelines for ultrasound guidance on the complication rates associated with central venous catheter placement in patients presenting for routine surgery in a tertiary referral centre. Br J Anaesth. 2007;99:662–5.PubMedCrossRef Wigmore TJ, Smythe JF, Hacking MB, Raobaikady R, MacCallum NS. Effect of the implementation of NICE guidelines for ultrasound guidance on the complication rates associated with central venous catheter placement in patients presenting for routine surgery in a tertiary referral centre. Br J Anaesth. 2007;99:662–5.PubMedCrossRef
12.
Zurück zum Zitat Peris A, Zagli G, Bonizzoli M, Cianchi G, Ciapetti M, Spina R, et al. Implantation of 3951 long-term central venous catheters: Performances, risk analysis, and patient comfort after ultrasound-guidance introduction. Anesth Analg. 2010;111:1194–201.PubMedCrossRef Peris A, Zagli G, Bonizzoli M, Cianchi G, Ciapetti M, Spina R, et al. Implantation of 3951 long-term central venous catheters: Performances, risk analysis, and patient comfort after ultrasound-guidance introduction. Anesth Analg. 2010;111:1194–201.PubMedCrossRef
13.
Zurück zum Zitat Bailey PL, Glance LG, Eaton MP, Parshall B, McIntosh S. A survey of the use of ultrasound during central venous catheterization. Anesth Analg. 2007;104:491–7.PubMedCrossRef Bailey PL, Glance LG, Eaton MP, Parshall B, McIntosh S. A survey of the use of ultrasound during central venous catheterization. Anesth Analg. 2007;104:491–7.PubMedCrossRef
14.
Zurück zum Zitat Matava C, Hayes J. A survey of ultrasound use by academic and community anesthesiologists in Ontario. Can J Anesth. 2011;58:929–35.PubMedCrossRef Matava C, Hayes J. A survey of ultrasound use by academic and community anesthesiologists in Ontario. Can J Anesth. 2011;58:929–35.PubMedCrossRef
15.
Zurück zum Zitat McGrattan T, Duffty J, Green JS, O’Donnell N. A survey of the use of ultrasound guidance in internal jugular venous cannulation. Anaesthesia 2008;63:1222–5.PubMedCrossRef McGrattan T, Duffty J, Green JS, O’Donnell N. A survey of the use of ultrasound guidance in internal jugular venous cannulation. Anaesthesia 2008;63:1222–5.PubMedCrossRef
16.
Zurück zum Zitat Cranney M, Warren E, Barton S, Gardner K, Walley T. Why do GPs not implement evidence-based guidelines? a descriptive study. Fam Pract. 2001;18:359–63.PubMedCrossRef Cranney M, Warren E, Barton S, Gardner K, Walley T. Why do GPs not implement evidence-based guidelines? a descriptive study. Fam Pract. 2001;18:359–63.PubMedCrossRef
17.
Zurück zum Zitat Saposnik G, Redelmeier D, Ruff CC, Tobler PN. Cognitive biases associated with medical decisions: a systematic review. BMC Med Inform Decis Mak. 2016;16(1):138.PubMedPubMedCentralCrossRef Saposnik G, Redelmeier D, Ruff CC, Tobler PN. Cognitive biases associated with medical decisions: a systematic review. BMC Med Inform Decis Mak. 2016;16(1):138.PubMedPubMedCentralCrossRef
18.
Zurück zum Zitat Beus JM, Dhanani LY, Mccord MA. A Meta-Analysis of personality and workplace safety: addressing unanswered questions. J Appl Psychol. 2015;100:481–98.PubMedCrossRef Beus JM, Dhanani LY, Mccord MA. A Meta-Analysis of personality and workplace safety: addressing unanswered questions. J Appl Psychol. 2015;100:481–98.PubMedCrossRef
19.
Zurück zum Zitat Costa PT. McCrae R. Normal personality assessment in clinical practice: the NEO Personality Inventory. Psychol Assess. 1992;4:5–13.CrossRef Costa PT. McCrae R. Normal personality assessment in clinical practice: the NEO Personality Inventory. Psychol Assess. 1992;4:5–13.CrossRef
20.
Zurück zum Zitat Hoekstra H, Ormel J, De Fruyt F. Handleiding NEO persoonlijkheids-vragenlijsten NEO-PI-R en NEO-FFI. Lisse: Hogrefe; 1996. Hoekstra H, Ormel J, De Fruyt F. Handleiding NEO persoonlijkheids-vragenlijsten NEO-PI-R en NEO-FFI. Lisse: Hogrefe; 1996.
21.
Zurück zum Zitat Jefferson P, Ogbue MN, Hamilton KES, Ball DR. A survey of the use of portable ultrasound for central vein cannulation on critical care units in the UK. Anaesthesia 2002;57:365–8.PubMedCrossRef Jefferson P, Ogbue MN, Hamilton KES, Ball DR. A survey of the use of portable ultrasound for central vein cannulation on critical care units in the UK. Anaesthesia 2002;57:365–8.PubMedCrossRef
22.
Zurück zum Zitat Harris N, Hodzovic I, Latto P. A national survey of the use of ultrasound locating devices for placing central venous catheters. Anaesthesia 2007;62:306–7.CrossRef Harris N, Hodzovic I, Latto P. A national survey of the use of ultrasound locating devices for placing central venous catheters. Anaesthesia 2007;62:306–7.CrossRef
23.
Zurück zum Zitat Karakitsos D, Labropoulos N, De Groot E, Patrianakos AP, Kouraklis G, Poularas J, et al. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit Care. 2006;10:R162.PubMedPubMedCentralCrossRef Karakitsos D, Labropoulos N, De Groot E, Patrianakos AP, Kouraklis G, Poularas J, et al. Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients. Crit Care. 2006;10:R162.PubMedPubMedCentralCrossRef
24.
Zurück zum Zitat Milling TJ, Rose J, Briggs WM, Birkhahn R, Gaeta TJ, Bove JJ, et al. Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: the Third Sonography Outcomes Assessment Program (SOAP-3) Trial*. Crit Care Med. 2005;33:1764–9.PubMedCrossRef Milling TJ, Rose J, Briggs WM, Birkhahn R, Gaeta TJ, Bove JJ, et al. Randomized, controlled clinical trial of point-of-care limited ultrasonography assistance of central venous cannulation: the Third Sonography Outcomes Assessment Program (SOAP-3) Trial*. Crit Care Med. 2005;33:1764–9.PubMedCrossRef
25.
Zurück zum Zitat Eisen LA, Narasimhan M, Berger JS, Mayo PH, Rosen MJ, Schneider RF. Mechanical complications of central venous catheters. J Intensive Care Med. 2006;21:40–6.PubMedCrossRef Eisen LA, Narasimhan M, Berger JS, Mayo PH, Rosen MJ, Schneider RF. Mechanical complications of central venous catheters. J Intensive Care Med. 2006;21:40–6.PubMedCrossRef
26.
Zurück zum Zitat Feller-Kopman D. Ultrasound-guided central venous catheter placement: The new standard of care? Crit Care Med. 2005;33:1875–7.PubMedCrossRef Feller-Kopman D. Ultrasound-guided central venous catheter placement: The new standard of care? Crit Care Med. 2005;33:1875–7.PubMedCrossRef
27.
Zurück zum Zitat Turiano NA, Mroczek DK, Moynihan J, Chapman BP. Big 5 personality traits and interleukin-6: evidence for “healthy neuroticism” in a US population sample. Brain Behav Immun. 2013;28:83–9.PubMedCrossRef Turiano NA, Mroczek DK, Moynihan J, Chapman BP. Big 5 personality traits and interleukin-6: evidence for “healthy neuroticism” in a US population sample. Brain Behav Immun. 2013;28:83–9.PubMedCrossRef
28.
Zurück zum Zitat Friedman HS, Clark M, Criqui L, Martin J, Schwartz C, Tomlinson-Keasey JT. Long-term relations of personality and health: dynamisms, mechanisms, tropisms. J Pers. 2000;68:6.CrossRef Friedman HS, Clark M, Criqui L, Martin J, Schwartz C, Tomlinson-Keasey JT. Long-term relations of personality and health: dynamisms, mechanisms, tropisms. J Pers. 2000;68:6.CrossRef
29.
Zurück zum Zitat Oehler A, Wedlich F. The relationship of extraversion and neuroticism with risk attitude, risk perception, and return expectations. J Neurosci Psychol Econ. 2018;11:63–92.CrossRef Oehler A, Wedlich F. The relationship of extraversion and neuroticism with risk attitude, risk perception, and return expectations. J Neurosci Psychol Econ. 2018;11:63–92.CrossRef
30.
Zurück zum Zitat Lauriola M, Levin IP. Personality traits and risky decision-making in a controlled experimental task: an exploratory study. Pers Individ Dif. 2001;31:215–26.CrossRef Lauriola M, Levin IP. Personality traits and risky decision-making in a controlled experimental task: an exploratory study. Pers Individ Dif. 2001;31:215–26.CrossRef
31.
Zurück zum Zitat Figner B, Weber EU. Personality and risk taking. In: Wright JD, editor. International encyclopedia of the social & behavioral sciences. 2nd ed. Amsterdam: Elsevier; 2015. pp. 809–13.CrossRef Figner B, Weber EU. Personality and risk taking. In: Wright JD, editor. International encyclopedia of the social & behavioral sciences. 2nd ed. Amsterdam: Elsevier; 2015. pp. 809–13.CrossRef
32.
Zurück zum Zitat Cho YI, Johnson TP, VanGeest JB. Enhancing surveys of health care professionals: a meta-analysis of techniques to improve response. Eval Health Prof. 2013;36:382–407.PubMedCrossRef Cho YI, Johnson TP, VanGeest JB. Enhancing surveys of health care professionals: a meta-analysis of techniques to improve response. Eval Health Prof. 2013;36:382–407.PubMedCrossRef
33.
Zurück zum Zitat VanDenKerkhof EG, Parlow JL, Goldstein DH, Milne B. In Canada, anesthesiologists are less likely to respond to an electronic, compared to a paper questionnaire. Can J Anesth. 2004;51:449–54.PubMedCrossRef VanDenKerkhof EG, Parlow JL, Goldstein DH, Milne B. In Canada, anesthesiologists are less likely to respond to an electronic, compared to a paper questionnaire. Can J Anesth. 2004;51:449–54.PubMedCrossRef
34.
Zurück zum Zitat Klabunde CN, Willis GB, Casalino LP. Facilitators and barriers to survey participation by physicians: a call to action for researchers. Eval Health Prof. 2013;36:279–95.PubMedCrossRef Klabunde CN, Willis GB, Casalino LP. Facilitators and barriers to survey participation by physicians: a call to action for researchers. Eval Health Prof. 2013;36:279–95.PubMedCrossRef
35.
Zurück zum Zitat Cabana MD, Rand CS, Powe NR, Wu AW, Wilson MH, Abboud P-AC, et al. Why don’t physicians follow clinical practice guidelines? JAMA J Am Med Assoc. 1999;282:1458–65.CrossRef Cabana MD, Rand CS, Powe NR, Wu AW, Wilson MH, Abboud P-AC, et al. Why don’t physicians follow clinical practice guidelines? JAMA J Am Med Assoc. 1999;282:1458–65.CrossRef
36.
Zurück zum Zitat Blumenthal-Barby J, Krieger H. Cognitive biases and heuristics in medical decision making: a critical review using a systematic search strategy. Med Decis Making. 2015;35:539–57.PubMedCrossRef Blumenthal-Barby J, Krieger H. Cognitive biases and heuristics in medical decision making: a critical review using a systematic search strategy. Med Decis Making. 2015;35:539–57.PubMedCrossRef
37.
Zurück zum Zitat Kahneman D, Knetsch JL, Thaler RH, Journal T, Winter N. Anomalies the endowment effect, loss aversion, and status quo bias. J Econ Perspect. 2001;5:193–206.CrossRef Kahneman D, Knetsch JL, Thaler RH, Journal T, Winter N. Anomalies the endowment effect, loss aversion, and status quo bias. J Econ Perspect. 2001;5:193–206.CrossRef
38.
Zurück zum Zitat Stiegler MP, Neelankavil JP, Canales C, Dhillon A. Cognitive errors detected in anaesthesiology: a literature review and pilot study. Br J Anaesth. 2012;108:229–35.PubMedCrossRef Stiegler MP, Neelankavil JP, Canales C, Dhillon A. Cognitive errors detected in anaesthesiology: a literature review and pilot study. Br J Anaesth. 2012;108:229–35.PubMedCrossRef
39.
Zurück zum Zitat Brenner LA, Koehler DJ, Rottenstreich Y. Remarks on support theory: recent advances and future directions. In: Gilovich T, Griffin D, Kahneman D, editors. Heuristics and biases: The psychology of intuitive judgment. New York: Cambridge University Press; 2002. pp. 489–509. Brenner LA, Koehler DJ, Rottenstreich Y. Remarks on support theory: recent advances and future directions. In: Gilovich T, Griffin D, Kahneman D, editors. Heuristics and biases: The psychology of intuitive judgment. New York: Cambridge University Press; 2002. pp. 489–509.
40.
Zurück zum Zitat Duffy FD, Holmboe ES. Self-assessment in lifelong learning and improving performance in practice. JAMA 2006;296:1137.PubMedCrossRef Duffy FD, Holmboe ES. Self-assessment in lifelong learning and improving performance in practice. JAMA 2006;296:1137.PubMedCrossRef
41.
Zurück zum Zitat Kahnemann D. Don’t blink! The hazards of confidence. New York Times. 2011. Kahnemann D. Don’t blink! The hazards of confidence. New York Times. 2011.
42.
Zurück zum Zitat Pronovost PJ. Enhancing physicians’ use of clinical guidelines. JAMA 2013;310(23):2501–2.CrossRef Pronovost PJ. Enhancing physicians’ use of clinical guidelines. JAMA 2013;310(23):2501–2.CrossRef
Metadaten
Titel
Barriers to ultrasound guidance for central venous access: a survey among Dutch intensivists and anaesthesiologists
verfasst von
Harm J. Scholten
Esther ten Bloemendal
Bente Botter
Hendrikus H. M. Korsten
R. Arthur Bouwman
Publikationsdatum
19.01.2019
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 6/2019
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-00246-z

Weitere Artikel der Ausgabe 6/2019

Journal of Clinical Monitoring and Computing 6/2019 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.