Skip to main content
Erschienen in: Critical Care 3/2011

01.06.2011 | Review

Bench-to-bedside review: Contrast enhanced ultrasonography - a promising technique to assess renal perfusion in the ICU

verfasst von: Antoine Schneider, Lynne Johnson, Mark Goodwin, Anthony Schelleman, Rinaldo Bellomo

Erschienen in: Critical Care | Ausgabe 3/2011

Einloggen, um Zugang zu erhalten

Abstract

Acute kidney injury (AKI) is common in critically ill patients and associated with important morbidity and mortality. Although alterations in renal perfusion are thought to play a causative role in the pathogenesis of AKI, there is, to date, no reliable technique that allows the assessment of renal perfusion that is applicable in the ICU. Contrast-enhanced ultrasound (CEUS) is an ultrasound imaging technique that makes use of microbubble-based contrast agents. These microbubbles, when injected into the bloodstream, allow visualization of vascular structures and, with contrast-specific imaging modes, detection of blood flow at the capillary level. Some recent CEUS-derived approaches allow quantification of blood flow in several organs, including the kidney. Current generation ultrasound contrast agents have strong stability and safety profiles. Along with post-marketing surveillance, numerous studies report safe administration of these agents, including in critically ill patients. This review presents information on the physical principles underlying CEUS, the methods allowing blood flow quantification and the potential applications of CEUS in critical care nephrology, currently as a research tool but perhaps in the future as a way of monitoring renal perfusion.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Uchino S, Kellum JA, Bellomo R, Doig GS, Morimatsu H, Morgera S, Schetz M, Tan I, Bouman C, Macedo E, Gibney N, Tolwani A, Ronco C, Beginning and Ending Supportive Therapy for the Kidney (BEST Kidney) Investigators: Acute renal failure in critically ill patients: a multinational, multicenter study. JAMA 2005, 294: 813-818. 10.1001/jama.294.7.813CrossRefPubMed Uchino S, Kellum JA, Bellomo R, Doig GS, Morimatsu H, Morgera S, Schetz M, Tan I, Bouman C, Macedo E, Gibney N, Tolwani A, Ronco C, Beginning and Ending Supportive Therapy for the Kidney (BEST Kidney) Investigators: Acute renal failure in critically ill patients: a multinational, multicenter study. JAMA 2005, 294: 813-818. 10.1001/jama.294.7.813CrossRefPubMed
2.
Zurück zum Zitat Levy EM, Viscoli CM, Horwitz RI: The effect of acute renal failure on mortality. A cohort analysis. JAMA 1996, 275: 1489-1494. 10.1001/jama.275.19.1489CrossRefPubMed Levy EM, Viscoli CM, Horwitz RI: The effect of acute renal failure on mortality. A cohort analysis. JAMA 1996, 275: 1489-1494. 10.1001/jama.275.19.1489CrossRefPubMed
3.
Zurück zum Zitat Chertow GM, Levy EM, Hammermeister KE, Grover F, Daley J: Independent association between acute renal failure and mortality following cardiac surgery. Am J Med 1998, 104: 343-348. 10.1016/S0002-9343(98)00058-8CrossRefPubMed Chertow GM, Levy EM, Hammermeister KE, Grover F, Daley J: Independent association between acute renal failure and mortality following cardiac surgery. Am J Med 1998, 104: 343-348. 10.1016/S0002-9343(98)00058-8CrossRefPubMed
4.
Zurück zum Zitat Prowle JR, Ishikawa K, May CN, Bellomo R: Renal blood flow during acute renal failure in man. Blood Purif 2009, 28: 216-225. 10.1159/000230813CrossRefPubMed Prowle JR, Ishikawa K, May CN, Bellomo R: Renal blood flow during acute renal failure in man. Blood Purif 2009, 28: 216-225. 10.1159/000230813CrossRefPubMed
5.
Zurück zum Zitat Selkurt EE: Renal blood flow and renal clearance in hemorraghic shock. Am J Physiol 1946, 145: 699-799.PubMed Selkurt EE: Renal blood flow and renal clearance in hemorraghic shock. Am J Physiol 1946, 145: 699-799.PubMed
6.
Zurück zum Zitat Wan L, Yang N, Hiew CY, Schelleman A, Johnson L, May C, Bellomo R: An assessment of the accuracy of renal blood flow estimation by Doppler ultrasound. Intensive Care Med 2008, 34: 1503-1510. 10.1007/s00134-008-1106-8CrossRefPubMed Wan L, Yang N, Hiew CY, Schelleman A, Johnson L, May C, Bellomo R: An assessment of the accuracy of renal blood flow estimation by Doppler ultrasound. Intensive Care Med 2008, 34: 1503-1510. 10.1007/s00134-008-1106-8CrossRefPubMed
7.
Zurück zum Zitat Hofmann L, Simon-Zoula S, Nowak A, Giger A, Vock P, Boesch C, Frey FJ, Vogt B: BOLD-MRI for the assessment of renal oxygenation in humans: acute effect of nephrotoxic xenobiotics. Kidney Int 2006, 70: 144-150. 10.1038/sj.ki.5000418CrossRefPubMed Hofmann L, Simon-Zoula S, Nowak A, Giger A, Vock P, Boesch C, Frey FJ, Vogt B: BOLD-MRI for the assessment of renal oxygenation in humans: acute effect of nephrotoxic xenobiotics. Kidney Int 2006, 70: 144-150. 10.1038/sj.ki.5000418CrossRefPubMed
8.
Zurück zum Zitat Prowle JR, Molan MP, Hornsey E, Bellomo R: Cine phase-contrast magnetic resonance imaging for the measurement of renal blood flow. Contrib Nephrol 2010, 165: 329-336.CrossRefPubMed Prowle JR, Molan MP, Hornsey E, Bellomo R: Cine phase-contrast magnetic resonance imaging for the measurement of renal blood flow. Contrib Nephrol 2010, 165: 329-336.CrossRefPubMed
9.
Zurück zum Zitat Geleskie JV, Shung KK: Further studies on acoustic impedance of major bovine blood vessel walls. J Acoust Soc Am 1982, 71: 467-470. 10.1121/1.387417CrossRefPubMed Geleskie JV, Shung KK: Further studies on acoustic impedance of major bovine blood vessel walls. J Acoust Soc Am 1982, 71: 467-470. 10.1121/1.387417CrossRefPubMed
10.
Zurück zum Zitat Ophir J, Parker KJ: Contrast agents in diagnostic ultrasound. Ultrasound Med Biol 1989, 15: 319-333. 10.1016/0301-5629(89)90044-6CrossRefPubMed Ophir J, Parker KJ: Contrast agents in diagnostic ultrasound. Ultrasound Med Biol 1989, 15: 319-333. 10.1016/0301-5629(89)90044-6CrossRefPubMed
11.
Zurück zum Zitat Schacherer D, Klebl F, Goetz D, Buettner R, Zierhut S, Schoelmerich J, Langgartner J: Abdominal ultrasound in the intensive care unit: a 3-year survey on 400 patients. Intensive Care Med 2007, 33: 841-844. 10.1007/s00134-007-0577-3CrossRefPubMed Schacherer D, Klebl F, Goetz D, Buettner R, Zierhut S, Schoelmerich J, Langgartner J: Abdominal ultrasound in the intensive care unit: a 3-year survey on 400 patients. Intensive Care Med 2007, 33: 841-844. 10.1007/s00134-007-0577-3CrossRefPubMed
12.
Zurück zum Zitat de Jong N, Ten Cate FJ, Lancee CT, Roelandt JR, Bom N: Principles and recent developments in ultrasound contrast agents. Ultrasonics 1991, 29: 324-330. 10.1016/0041-624X(91)90030-CCrossRefPubMed de Jong N, Ten Cate FJ, Lancee CT, Roelandt JR, Bom N: Principles and recent developments in ultrasound contrast agents. Ultrasonics 1991, 29: 324-330. 10.1016/0041-624X(91)90030-CCrossRefPubMed
13.
Zurück zum Zitat Raisinghani A, Rafter P, Phillips P, Vannan MA, DeMaria AN: Microbubble contrast agents for echocardiography: rationale, composition, ultrasound interactions, and safety. Cardiol Clin 2004, 22: 171-180. v 10.1016/j.ccl.2004.02.001CrossRefPubMed Raisinghani A, Rafter P, Phillips P, Vannan MA, DeMaria AN: Microbubble contrast agents for echocardiography: rationale, composition, ultrasound interactions, and safety. Cardiol Clin 2004, 22: 171-180. v 10.1016/j.ccl.2004.02.001CrossRefPubMed
14.
Zurück zum Zitat Romero JR, Frey JL, Schwamm LH, Demaerschalk BM, Chaliki HP, Parikh G, Burke RF, Babikian VL: Cerebral ischemic events associated with 'bubble study' for identification of right to left shunts. Stroke 2009, 40: 2343-2348. 10.1161/STROKEAHA.109.549683CrossRefPubMed Romero JR, Frey JL, Schwamm LH, Demaerschalk BM, Chaliki HP, Parikh G, Burke RF, Babikian VL: Cerebral ischemic events associated with 'bubble study' for identification of right to left shunts. Stroke 2009, 40: 2343-2348. 10.1161/STROKEAHA.109.549683CrossRefPubMed
15.
Zurück zum Zitat Feinstein SB, Cheirif J, Ten Cate FJ, Silverman PR, Heidenreich PA, Dick C, Desir RM, Armstrong WF, Quinones MA, Shah PM: Safety and efficacy of a new transpulmonary ultrasound contrast agent: initial multicenter clinical results. J Am Coll Cardiol 1990, 16: 316-324. 10.1016/0735-1097(90)90580-ICrossRefPubMed Feinstein SB, Cheirif J, Ten Cate FJ, Silverman PR, Heidenreich PA, Dick C, Desir RM, Armstrong WF, Quinones MA, Shah PM: Safety and efficacy of a new transpulmonary ultrasound contrast agent: initial multicenter clinical results. J Am Coll Cardiol 1990, 16: 316-324. 10.1016/0735-1097(90)90580-ICrossRefPubMed
16.
Zurück zum Zitat Klibanov A: Ultrasound contrast agents: development of the field and current status. Topics Curr Chem 2002, 222: 73-106. 10.1007/3-540-46009-8_3CrossRef Klibanov A: Ultrasound contrast agents: development of the field and current status. Topics Curr Chem 2002, 222: 73-106. 10.1007/3-540-46009-8_3CrossRef
17.
Zurück zum Zitat Morel DR, Schwieger I, Hohn L, Terrettaz J, Llull JB, Cornioley YA, Schneider M: Human pharmacokinetics and safety evaluation of SonoVue, a new contrast agent for ultrasound imaging. Invest Radiol 2000, 35: 80-85. 10.1097/00004424-200001000-00009CrossRefPubMed Morel DR, Schwieger I, Hohn L, Terrettaz J, Llull JB, Cornioley YA, Schneider M: Human pharmacokinetics and safety evaluation of SonoVue, a new contrast agent for ultrasound imaging. Invest Radiol 2000, 35: 80-85. 10.1097/00004424-200001000-00009CrossRefPubMed
18.
19.
20.
Zurück zum Zitat Mulvagh SL, Rakowski H, Vannan MA, Abdelmoneim SS, Becher H, Bierig SM, Burns PN, Castello R, Coon PD, Hagen ME, Jollis JG, Kimball TR, Kitzman DW, Kronzon I, Labovitz AJ, Lang RM, Mathew J, Moir WS, Nagueh SF, Pearlman AS, Perez JE, Porter TR, Rosenbloom J, Strachan GM, Thanigaraj S, Wei K, Woo A, Yu EH, Zoghbi WA, American Society of Echocardiography: American Society of Echocardiography Consensus Statement on the Clinical Applications of Ultrasonic Contrast Agents in Echocardiography. J Am Soc Echocardiogr 2008, 21: 1179-1201. quiz 1281 10.1016/j.echo.2008.09.009CrossRefPubMed Mulvagh SL, Rakowski H, Vannan MA, Abdelmoneim SS, Becher H, Bierig SM, Burns PN, Castello R, Coon PD, Hagen ME, Jollis JG, Kimball TR, Kitzman DW, Kronzon I, Labovitz AJ, Lang RM, Mathew J, Moir WS, Nagueh SF, Pearlman AS, Perez JE, Porter TR, Rosenbloom J, Strachan GM, Thanigaraj S, Wei K, Woo A, Yu EH, Zoghbi WA, American Society of Echocardiography: American Society of Echocardiography Consensus Statement on the Clinical Applications of Ultrasonic Contrast Agents in Echocardiography. J Am Soc Echocardiogr 2008, 21: 1179-1201. quiz 1281 10.1016/j.echo.2008.09.009CrossRefPubMed
21.
Zurück zum Zitat Fisher NG, Christiansen JP, Leong-Poi H, Jayaweera AR, Lindner JR, Kaul S: Myocardial and microcirculatory kinetics of BR14, a novel third-generation intravenous ultrasound contrast agent. J Am Coll Cardiol 2002, 39: 530-537. 10.1016/S0735-1097(01)01759-4CrossRefPubMed Fisher NG, Christiansen JP, Leong-Poi H, Jayaweera AR, Lindner JR, Kaul S: Myocardial and microcirculatory kinetics of BR14, a novel third-generation intravenous ultrasound contrast agent. J Am Coll Cardiol 2002, 39: 530-537. 10.1016/S0735-1097(01)01759-4CrossRefPubMed
22.
Zurück zum Zitat Lindner JR, Song J, Jayaweera AR, Sklenar J, Kaul S: Microvascular rheology of DeFinity microbubbles after intra-arterial and intravenous administration. J Am Soc Echocardiogr 2002, 15: 396-403. 10.1067/mje.2002.117290CrossRefPubMed Lindner JR, Song J, Jayaweera AR, Sklenar J, Kaul S: Microvascular rheology of DeFinity microbubbles after intra-arterial and intravenous administration. J Am Soc Echocardiogr 2002, 15: 396-403. 10.1067/mje.2002.117290CrossRefPubMed
23.
Zurück zum Zitat Braide M, Rasmussen H, Albrektsson A, Bagge U: Microvascular behavior and effects of sonazoid microbubbles in the cremaster muscle of rats after local administration. J Ultrasound Med 2006, 25: 883-890.PubMed Braide M, Rasmussen H, Albrektsson A, Bagge U: Microvascular behavior and effects of sonazoid microbubbles in the cremaster muscle of rats after local administration. J Ultrasound Med 2006, 25: 883-890.PubMed
24.
Zurück zum Zitat Kusnetzky LL, Khalid A, Khumri TM, Moe TG, Jones PG, Main ML: Acute mortality in hospitalized patients undergoing echocardiography with and without an ultrasound contrast agent: results in 18,671 consecutive studies. J Am Coll Cardiol 2008, 51: 1704-1706. 10.1016/j.jacc.2008.03.006CrossRefPubMed Kusnetzky LL, Khalid A, Khumri TM, Moe TG, Jones PG, Main ML: Acute mortality in hospitalized patients undergoing echocardiography with and without an ultrasound contrast agent: results in 18,671 consecutive studies. J Am Coll Cardiol 2008, 51: 1704-1706. 10.1016/j.jacc.2008.03.006CrossRefPubMed
25.
Zurück zum Zitat Dolan MS, Gala SS, Dodla S, Abdelmoneim SS, Xie F, Cloutier D, Bierig M, Mulvagh SL, Porter TR, Labovitz AJ: Safety and efficacy of commercially available ultrasound contrast agents for rest and stress echocardiography a multicenter experience. J Am Coll Cardiol 2009, 53: 32-38. 10.1016/j.jacc.2008.08.066CrossRefPubMed Dolan MS, Gala SS, Dodla S, Abdelmoneim SS, Xie F, Cloutier D, Bierig M, Mulvagh SL, Porter TR, Labovitz AJ: Safety and efficacy of commercially available ultrasound contrast agents for rest and stress echocardiography a multicenter experience. J Am Coll Cardiol 2009, 53: 32-38. 10.1016/j.jacc.2008.08.066CrossRefPubMed
26.
Zurück zum Zitat Main ML, Ryan AC, Davis TE, Albano MP, Kusnetzky LL, Hibberd M: Acute mortality in hospitalized patients undergoing echocardiography with and without an ultrasound contrast agent (multicenter registry results in 4,300,966 consecutive patients). Am J Cardiol 2008, 102: 1742-1746. 10.1016/j.amjcard.2008.08.019CrossRefPubMed Main ML, Ryan AC, Davis TE, Albano MP, Kusnetzky LL, Hibberd M: Acute mortality in hospitalized patients undergoing echocardiography with and without an ultrasound contrast agent (multicenter registry results in 4,300,966 consecutive patients). Am J Cardiol 2008, 102: 1742-1746. 10.1016/j.amjcard.2008.08.019CrossRefPubMed
27.
Zurück zum Zitat Wei K, Mulvagh SL, Carson L, Davidoff R, Gabriel R, Grimm RA, Wilson S, Fane L, Herzog CA, Zoghbi WA, Taylor R, Farrar M, Chaudhry FA, Porter TR, Irani W, Lang RM: The safety of deFinity and Optison for ultrasound image enhancement: a retrospective analysis of 78,383 administered contrast doses. J Am Soc Echocardiogr 2008, 21: 1202-1206. 10.1016/j.echo.2008.07.019CrossRefPubMed Wei K, Mulvagh SL, Carson L, Davidoff R, Gabriel R, Grimm RA, Wilson S, Fane L, Herzog CA, Zoghbi WA, Taylor R, Farrar M, Chaudhry FA, Porter TR, Irani W, Lang RM: The safety of deFinity and Optison for ultrasound image enhancement: a retrospective analysis of 78,383 administered contrast doses. J Am Soc Echocardiogr 2008, 21: 1202-1206. 10.1016/j.echo.2008.07.019CrossRefPubMed
28.
Zurück zum Zitat Jiménez C, de Gracia R, Aguilera A, Alonso S, Cirugeda A, Benito J, Regojo RM, Aguilar R, Warlters A, Gómez R, Largo C, Selgas R: In situ kidney insonation with microbubble contrast agents does not cause renal tissue damage in a porcine model. J Ultrasound Med 2008, 27: 1607-1615.PubMed Jiménez C, de Gracia R, Aguilera A, Alonso S, Cirugeda A, Benito J, Regojo RM, Aguilar R, Warlters A, Gómez R, Largo C, Selgas R: In situ kidney insonation with microbubble contrast agents does not cause renal tissue damage in a porcine model. J Ultrasound Med 2008, 27: 1607-1615.PubMed
29.
Zurück zum Zitat Wei K, Jayaweera AR, Firoozan S, Linka A, Skyba DM, Kaul S: Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 1998, 97: 473-483.CrossRefPubMed Wei K, Jayaweera AR, Firoozan S, Linka A, Skyba DM, Kaul S: Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. Circulation 1998, 97: 473-483.CrossRefPubMed
30.
Zurück zum Zitat Wei K, Le E, Bin JP, Coggins M, Thorpe J, Kaul S: Quantification of renal blood flow with contrast-enhanced ultrasound. J Am Coll Cardiol 2001, 37: 1135-1140. 10.1016/S0735-1097(00)01210-9CrossRefPubMed Wei K, Le E, Bin JP, Coggins M, Thorpe J, Kaul S: Quantification of renal blood flow with contrast-enhanced ultrasound. J Am Coll Cardiol 2001, 37: 1135-1140. 10.1016/S0735-1097(00)01210-9CrossRefPubMed
31.
Zurück zum Zitat Tiemann K, Becher H, Lohmeier S: Real-time assessment of tissue perfusion following bubble destruction at low emission-power - first experimental results using power pulse inversion imaging. J Am Coll Cardiol 2000, 35: 426A. Tiemann K, Becher H, Lohmeier S: Real-time assessment of tissue perfusion following bubble destruction at low emission-power - first experimental results using power pulse inversion imaging. J Am Coll Cardiol 2000, 35: 426A.
32.
Zurück zum Zitat Arditi M, Frinking PJ, Zhou X, Rognin NG: A new formalism for the quantification of tissue perfusion by the destruction-replenishment method in contrast ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control 2006, 53: 1118-1129.CrossRefPubMed Arditi M, Frinking PJ, Zhou X, Rognin NG: A new formalism for the quantification of tissue perfusion by the destruction-replenishment method in contrast ultrasound imaging. IEEE Trans Ultrason Ferroelectr Freq Control 2006, 53: 1118-1129.CrossRefPubMed
33.
Zurück zum Zitat Rim SJ, Leong-Poi H, Lindner JR, Couture D, Ellegala D, Mason H, Durieux M, Kassel NF, Kaul S: Quantification of cerebral perfusion with "real-time" contrast-enhanced ultrasound. Circulation 2001, 104: 2582-2587. 10.1161/hc4601.099400CrossRefPubMed Rim SJ, Leong-Poi H, Lindner JR, Couture D, Ellegala D, Mason H, Durieux M, Kassel NF, Kaul S: Quantification of cerebral perfusion with "real-time" contrast-enhanced ultrasound. Circulation 2001, 104: 2582-2587. 10.1161/hc4601.099400CrossRefPubMed
34.
Zurück zum Zitat Vogel R, Indermuhle A, Reinhardt J, Meier P, Siegrist PT, Namdar M, Kaufmann PA, Seiler C: The quantification of absolute myocardial perfusion in humans by contrast echocardiography: algorithm and validation. J Am Coll Cardiol 2005, 45: 754-762. 10.1016/j.jacc.2004.11.044CrossRefPubMed Vogel R, Indermuhle A, Reinhardt J, Meier P, Siegrist PT, Namdar M, Kaufmann PA, Seiler C: The quantification of absolute myocardial perfusion in humans by contrast echocardiography: algorithm and validation. J Am Coll Cardiol 2005, 45: 754-762. 10.1016/j.jacc.2004.11.044CrossRefPubMed
35.
Zurück zum Zitat Kishimoto N, Mori Y, Nishiue T, Shibasaki Y, Iba O, Nose A, Uchiyama-Tanaka Y, Masaki H, Matsubara H, Iwasaka T: Renal blood flow measurement with contrast-enhanced harmonic ultrasonography: evaluation of dopamine-induced changes in renal cortical perfusion in humans. Clin Nephrol 2003, 59: 423-428.CrossRefPubMed Kishimoto N, Mori Y, Nishiue T, Shibasaki Y, Iba O, Nose A, Uchiyama-Tanaka Y, Masaki H, Matsubara H, Iwasaka T: Renal blood flow measurement with contrast-enhanced harmonic ultrasonography: evaluation of dopamine-induced changes in renal cortical perfusion in humans. Clin Nephrol 2003, 59: 423-428.CrossRefPubMed
36.
Zurück zum Zitat Kishimoto N, Mori Y, Nishiue T, Nose A, Kijima Y, Tokoro T, Yamahara H, Okigaki M, Kosaki A, Iwasaka T: Ultrasound evaluation of valsartan therapy for renal cortical perfusion. Hypertens Res 2004, 27: 345-349. 10.1291/hypres.27.345CrossRefPubMed Kishimoto N, Mori Y, Nishiue T, Nose A, Kijima Y, Tokoro T, Yamahara H, Okigaki M, Kosaki A, Iwasaka T: Ultrasound evaluation of valsartan therapy for renal cortical perfusion. Hypertens Res 2004, 27: 345-349. 10.1291/hypres.27.345CrossRefPubMed
37.
Zurück zum Zitat Kalantarinia K, Belcik JT, Patrie JT, Wei K: Real-time measurement of renal blood flow in healthy subjects using contrast-enhanced ultrasound. Am J Physiol Renal Physiol 2009, 297: F1129-1134. 10.1152/ajprenal.00172.2009PubMedCentralCrossRefPubMed Kalantarinia K, Belcik JT, Patrie JT, Wei K: Real-time measurement of renal blood flow in healthy subjects using contrast-enhanced ultrasound. Am J Physiol Renal Physiol 2009, 297: F1129-1134. 10.1152/ajprenal.00172.2009PubMedCentralCrossRefPubMed
38.
Zurück zum Zitat Schneider A, Eggimann P, Burnier M, Vogt B: Renal perfusion quantification with contrast echography [abstract]. Swiss Med Forum 2009,9(Suppl 48):7S. Schneider A, Eggimann P, Burnier M, Vogt B: Renal perfusion quantification with contrast echography [abstract]. Swiss Med Forum 2009,9(Suppl 48):7S.
39.
Zurück zum Zitat Fischer T, Dieckhofer J, Muhler M, Lembcke A, Morgera S, Budde K, Neumayer HH, Ebeling V, Thomas A, Filimonow S: The use of contrast-enhanced US in renal transplant: first results and potential clinical benefi t. Eur Radiol 2005,15(Suppl 5):E109-116.CrossRefPubMed Fischer T, Dieckhofer J, Muhler M, Lembcke A, Morgera S, Budde K, Neumayer HH, Ebeling V, Thomas A, Filimonow S: The use of contrast-enhanced US in renal transplant: first results and potential clinical benefi t. Eur Radiol 2005,15(Suppl 5):E109-116.CrossRefPubMed
40.
Zurück zum Zitat Schwenger V, Korosoglou G, Hinkel UP, Morath C, Hansen A, Sommerer C, Dikow R, Hardt S, Schmidt J, Kücherer H, Katus HA, Zeier M: Real-time contrast-enhanced sonography of renal transplant recipients predicts chronic allograft nephropathy. Am J Transplant 2006, 6: 609-615. 10.1111/j.1600-6143.2005.01224.xCrossRefPubMed Schwenger V, Korosoglou G, Hinkel UP, Morath C, Hansen A, Sommerer C, Dikow R, Hardt S, Schmidt J, Kücherer H, Katus HA, Zeier M: Real-time contrast-enhanced sonography of renal transplant recipients predicts chronic allograft nephropathy. Am J Transplant 2006, 6: 609-615. 10.1111/j.1600-6143.2005.01224.xCrossRefPubMed
41.
Zurück zum Zitat Benozzi L, Cappelli G, Granito M, Davoli D, Favali D, Montecchi MG, Grossi A, Torricelli P, Albertazzi A: Contrast-enhanced sonography in early kidney graft dysfunction. Transplant Proc 2009, 41: 1214-1215. 10.1016/j.transproceed.2009.03.029CrossRefPubMed Benozzi L, Cappelli G, Granito M, Davoli D, Favali D, Montecchi MG, Grossi A, Torricelli P, Albertazzi A: Contrast-enhanced sonography in early kidney graft dysfunction. Transplant Proc 2009, 41: 1214-1215. 10.1016/j.transproceed.2009.03.029CrossRefPubMed
Metadaten
Titel
Bench-to-bedside review: Contrast enhanced ultrasonography - a promising technique to assess renal perfusion in the ICU
verfasst von
Antoine Schneider
Lynne Johnson
Mark Goodwin
Anthony Schelleman
Rinaldo Bellomo
Publikationsdatum
01.06.2011
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 3/2011
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/cc10058

Weitere Artikel der Ausgabe 3/2011

Critical Care 3/2011 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.