Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 5/2021

Open Access 02.12.2020 | Review Article

Biomechanics and clinical outcome after posterior stabilization of mid-thoracic vertebral body fractures: a systematic literature review

verfasst von: Ulrich J. Spiegl, Georg Osterhoff, Philipp Bula, Frank Hartmann, Max J. Scheyerer, Klaus J. Schnake, Bernhard W. Ullrich

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 5/2021

Abstract

Purpose

The aim of this review is to systematically screen the literature for clinical and biomechanical studies dealing with posterior stabilization of acute traumatic mid-thoracic vertebral fractures in patients with normal bone quality.

Methods

This review is based on articles retrieved by a systematic search in the PubMed and Web of Science database for publications up to December 2018 dealing with the posterior stabilization of fractures of the mid-thoracic spine.

Results

Altogether, 1012 articles were retrieved from the literature search. A total of 960 articles were excluded. A total of 16 articles were dealing with the timing of surgery in polytraumatized patients, patients suffering of neurologic deficits after midthoracic fractures, and the impact of concomitant thoracic injuries and were excluded. Thus, 36 remaining original articles were included in this systematic review depicting the topics biomechanics, screw insertion, and outcome after posterior stabilization. The overall level of evidence of the vast majority of studies is low.

Conclusion

High quality studies are lacking. Long-segmental stabilization is indicated in unstable midthoracic fractures with concomitant sternal fractures. Generally, long-segmental constructs seem to be the safer treatment strategy considering the relative high penetration rate of pedicle screws in this region. Thereby, navigated insertion techniques and intraoperative 3D-imaging help to improve pedicle screw placement accuracy.

Introduction

The majority of traumatic vertebral fractures occur at the thoracolumbar junction and less commonly at the mid-thoracic or mid-lumbar spine [32]. In accordance, a high number of articles are dealing with thoracolumbar fractures focusing on the thoracolumbar junction. Nonetheless, the anatomy and biomechanics of the mid-thoracic spine differ from the thoracolumbar junction. First of all, the vertebral bodies including the pedicles are smaller at the thoracic spine, the orientation of the facet joints is different allowing rotational motion [44]. Next, the thoracic cage, defined as the fourth column by several authors, stabilizes the thoracic spine and leads to a higher stiffness [39]. Last but not least, the sagittal alignment of the thoracic spine consisting of a kyphosis differs tremendously from the thoracolumbar junction and the lordotic lumbar spine [33].
Based on these differences, the thoracic spine needs to be analyzed separately. According to literature, posterior stabilization is the most common used treatment strategy in unstable mid-thoracic fractures [37].
The aim of this review is to systematically review the literature for clinical and biomechanical studies dealing with posterior stabilization of acute traumatic mid-thoracic vertebral fractures. From this, the current state of evidence considering all aspects of the posterior stabilization shall be described. Based on these results, prospective studies could be created to increase the evidence in this field.

Methods

The literature search included unstable recent vertebral fractures (< 4 weeks) of the mid-thoracic spine (Th 2—Th 10) of adults treated by posterior stabilization with adequate trauma history. Children and adolescents (age < 18) and elderly (age > 65) with likely concomitant osteopenia/osteoporosis were not within the scope of this review and need to be analyzed separately. Furthermore, patients with fractures after non-adequate trauma (trivial falls from tripping) were not included in this review.
A systematic search of the literature was performed by two of the authors (UJS, BWU), including all articles until 12/26/2018. In each case, the two databases PubMed and Web of Science Core Collection were considered and searched. Excluded were articles dealing with osteoporotic or pathologic vertebral body fractures, cervical and/or lumbar vertebral body fractures, and exclusively non-operative therapy strategies. Furthermore studies dealing with the timing of surgery in polytraumatized patients, patients suffering of neurologic deficits after midthoracic fractures, and the impact of concomitant thoracic injuries and were excluded. Additionally, case reports, reviews, and animals studies were excluded. Since data collection had already been completed at the time of PROSPERO registration, this review could not be registered with PROSPERO. Using the PICO scheme [11], the following review questions were defined:
  • What is the recommended insertion technique of pedicle screws at the mid-thoracic spine?
  • Short or long segmental stabilization—what should be preferred
  • What is the expected outcome of fractures of the mid-thoracic spine treated by posterior stabilization?
The following search terms were used: “thoracic vertebral body fractures” OR “thoracic vertebral spine fractures” NOT “Osteoporosis” NOT “case report” NOT “tumor” NOT “lumbar spine”.
Subsequently, all relevant original articles were analyzed based on their levels of evidence and their appropriate conclusions. Here, the following topic areas were defined:
  • Biomechanics
  • Screw insertion
  • Outcome after posterior stabilization

Results

Altogether, 1012 abstracts were retrieved from the literature search (Fig. 1). Of these, articles were excluded based on abstract or title. Most of the excluded studies were overlaps between both databases, animals studies, no original articles or were articles investigated other pathologies or included cervical or lumbar factures, or exclusively evaluated non-operative treatment or anterior approaches. Altogether, 78 articles were analyzed completely. Of these articles 26 were additionally excluded, not focusing specifically on the thoracic spine, including geriatric patients or insufficiently describing the method of posterior stabilization. A total of 16 articles analyzed the timing of surgery in polytraumatized patients, reported of patients suffering of neurologic deficits after midthoracic fractures, and evaluated the impact of concomitant thoracic injuries and were excluded. Altogether, 976 articles were excluded (Fig. 1). All 36 remaining original articles, which covered the period from 1971 to 2018 are summarized in Tables 1, 2 and 3. Levels of evidence were defined as described by Bassler and Antes [1].
Table 1
Biomechanical studies
Study
Purpose
Key message
Watkin et al. [43] (2005)
Amount of stability provided by the rib cage
The intact rib cage provides high stability in all motion directions
Sternal fractures decrease stability particularly in extension-flexion motion
Perry et al. [30] (2014)
Long segment versus short segment instrumentation in thoracic burst fracture
Long segment instrumentation superior during flexion–extension
During lateral bending and axial rotation short and long instrumentations are comparable
Lazaro et al. [24] (2011)
Long segment instrumentation versus short instrumentation with cross-links and/or index screws
Index screws increase stability about 25%
Cross-links only stabilize during axial rotation
Hongo et al. [18] (2009)
Metal clamps combined with polyester belts versus sublaminar wiring versus hooks versus pedicle screws
Pedicle screw fixation is superior
Little et al. [26] (2010)
Costotransverse process screws versus pedicle screws
Pedicle screw fixation is superior
Table 2
Studies dealing with pedicle screw placement
Study
(year)
Purpose
Study design
No of screws
Main message
Ev-L
Vaccari et al. [40] (1995)
Pedicle screw insertion in Roy-Camille technique
Cadaver study
90
Screw penetration rate of 41%
n.a
Kothe et al. [22] (2001)
Navigated parapedicular insertion technique
Cadaver study
54
Safe and reliable technique
n.a
Reidy et al. [31] (2001)
Is intraoperative EMG-monitoring necessary
Prospective cohort study
95
No improvement in accuracy could be observed
II
Husted et al. [21] (2003)
Parapedicular approach
Cadaver study
24
No spinal canal penetration
No pleural or foraminal penetration
n.a
Schnake et al. [35] (2004)
Navigated screw insertion
Prospective cohort study
324
Significant reduction in all screw penetrations
Significant reduction in relevant screw penetration
II
Mac-Thiong et al. [27] (2003)
Evaluation of special drill guide for pedicle screw accuracy
Cadaver study
66
No screw penetration of more than 2 mm could be seen
IV
Bransford et al. [4] (2006)
Accuracy of free-hand pedicle screw placement under fluoroscopic control
Retrospective case series
1533
No major complication was observed
1.2% of prophylactic revision surg. due to screw malposition
IV
Dhawan et al. [9] (2008)
Comparison of the pedicle screw insertion direction
Cadaver study
966
The anatomic position leads to a 20% larger effective pedicle diameter
n.a
Chan et al. [6] (2010)
Evaluating the funnel technique
Cadaver study
240
No medial pedicle penetration by direct visualization via wide laminectomy
n.a
Wu et al. [43] (2010)
Free-hand versus navigated pedicle screw placement
Prospective randomized trial
176
Significant less pedicle screw penetrations with navigation
Significant reduced radiation time with navigation
Faster pedicle screw placement with navigation
II
Beck et al. [2] (2012)
Benefit of intraoperative 3D-imaging for pedicle screw accuracy
Prospective case series
240
3.8% intraoperative pedicle screw revision
2.5% of postoperative pedicle screw penetration, all grade I (< 2 mm)
III
Lehmann et al. [25] (2014)
Identification of the ideal starting point of pedicle screw insertion
Cadaver study
229
2–3 mm lateral to the midline of the superior articular facet
n.a
Cho et al. [7] (2015)
Feasibility of translaminar screws
Cadaver study
294
Safe technique
Small number of moderate penetrations
n.a
Gonzalvo et al. [16] (2015)
Pedicle penetration rate in dependeny of the pedicle diameter
Retrospective case series
218
Penetration rate of 33%: pedicles diameter < 5 mm
Penetration rate of 11%:
 Pedicle diameter 5–7 mm
 No penetrations if pedicle diameter > 7 mm
IV
Hu et al. [19]
(2015)
Anatomic feasibility of translaminar screw placement
Cadaver study
6
Translaminar screws are not limited by anatomy in Asian patients
n.a
Kwan et al. [23]
(2015)
Comparison of pedicle screw accuracy between percutaneous and open placement
Cadaver study
288
Percutaneous technique has a similar accuracy compared to the open placement
Penetration rate: 11% open versus 8% percutaneous
n.a
Fischer et al. [12]
(2016)
Gguide wire-based pedicle screw insertion under CT-imaging
Retrospective case series
286
Very high accuracy and low complication rate using this technique
IV
Table 3
Clinical outcome studies
Study (year)
Purpose
Study design
N
FU (months)
Main message
Ev-L
Capen et al. [5] (1994)
Non-operative treatment of upper thoracic spine fractures
Retrospective case series
49
No data
Conservative treatment of fractures from T1 to T8 can be successful
IV
Harkönen et al. [17] (1979)
Non-operative treatment of thoracic spine fractures
Retrospective case series
98 (75)
64
Non-operative treatment did not prevent aggravation of rad.deformity
Clinical results were poor in patients with deformities
IV
Zifko et al. [48] (1971)
Non-operative treatment of thoracic spine fractures
Retrospective case series
271 (132)
60–108
Fractures with involvement of the discs and posterior ligaments associated with secondary deformity
IV
Dai et al. [8] (2001)
Operative and non-operative treatment of thoracic spine fractures
Retrospective case series
53 non-op vs. 24 op
24—180
“Unstable” fractures should be stabilized operatively
IV
Schouten et al. [36] (2014)
Quality of life after thoracic fractures
(non-operative and operative treatment)
Cross-sectional cohort study based on prospective database
28 (non-op) vs. 98 (operative)
12–186
Patients with ASIA D or E recover fully in general health
They have a favorable prognosis compared with other spinal injuries
III
Huckell et al. [20] (1994)
Distraction rod vs Luque rod fixation of thoracic spine fractures
Retrospective case series
34
 > 6 months
At final follow-up kyphosis
returned to the preoperative values in both groups
IV
Yue et al. [46] (2002)
Operative treatment of thoracic spine fractures (incl. L1)
Retrospective case series
32
22
Posterior pedicle screw fixation of thoracic fractures is safe
IV
Payer et al. [29] (2005)
Operative treatment of upper thoracic spine fractures
Retrospective case series
8
15
Posterior pedicle screw fixation of upper thoracic fractures is safe
IV-
Fisher et al. [13] (2009)
Operative treatment of upper thoracic spine fractures
Retrospective case series
27
28
Posterior pedicle screw fixation of upper thoracic fractures is safe end efficacious
IV
Marré et al. [28] (2011)
Operative treatment of thoracic spine fractures
Retrospective case series
51
12
Neurological impairment was the most important predictor of complications and disability
IV
Vassal et al. [41] (2014)
Operative treatment of thoracic spine fractures
Retrospective case series
50
23
Deformity can be seen during follow-up
Restitution of the anterior column must be considered more frequently
Quality of life at follow-up did not correlate with initial deformity
IV
Zhang et al. [47] (2015)
Timing of operative treatment of C3 thoracic fractures
Retrospective cohort study
36
23
No superiority of early (< 72 h) fixation in C3 thoracic fractures
IV
Gattozzi et al. [14] (2018)
Operative treatment of upper thoracic spine fractures
Retrospective case series
43
12
Surgical treatment of upper thoracic spine fractures is safe and effective
IV
Ghasemi et al. [15] (2016)
Operative treatment of thoracic spine fractures
Retrospective case series
25
15 (6–22)
Kyphotic deformity can be corrected by pedicle screw fixation
Neurologic symptoms might recover
IV

Biomechanics

A total of five studies dealt with mainly biomechanical aspects of posterior stabilization of thoracic fractures (Table 1). Generally, the thoracic spine is biomechanically stiffer than the other regions of the spine, because of two anatomical characteristics: the first one is the articulation of the head of the ribs with the articular facets of the adjacent vertebral bodies in combination with the radiate ligaments, which attach to the head of the ribs and both adjacent vertebral bodies, and the costotransverse ligaments. The second is the structure of the thoracic cage itself, which increases the resistance to all directions of motion [44]. Watkins et al. [43] evaluated the amount of stability provided by the rib cage and the sternum. In their study, the intact rib cage provided 40% of the stability of the thoracic spine in flexion–extension, 35% in lateral bending and 31% in axial rotation. A sternal fracture decreased the stability of the thoracic spine significantly by 42% in flexion–extension, 22% in lateral bending and 15% in axial rotation. Berg et al. [3] observed two clinical cases of combined sternal and thoracic spine fractures, which developed significant kyphotic deformities after nonoperative treatment and postulated the sternal-rib complex as the fourth column of the spine based on the three column theory of the spine by Denis. In general, the structural instability of thoracic fractures is treated with posterior instrumentation 2 levels above and below the fracture site, but in case of intact rib cage a short segment fixation with 1 level above and below the fractured vertebra could be an alternative. Therefore, Perry et al. [30] created a burst fracture at T9 in eight human thoracic spines (C7–L1) with intact rib cages and tested a long segment instrumentation (3 above, 2 below), a short segment instrumentation (1 above/1 below) with and without vertebral augmentation and vertebral augmentation without instrumentation. In their study, the long segment instrumentation showed a significant reduction of ROM during flexion–extension (− 90%), whereas the other instrumentations only tended to reduce motion. However, Perry et al. [30] suggested that in case of intact rib cages short segment instrumentation might adequately stabilize the spine. A common strategy to increase stability of short segment fixation is the addition of cross-links or screws at fracture site (index screws). Lazaro et al. [24] evaluated seven human thoracic spine segments after creating a wedge fracture in five conditions: long segment fixation (2 above/2 below) with cross-link, short segment fixation (1 above/1 below), short segment fixation with cross links, short segment fixation with index screws and short segment fixation with index screws and cross-link. The long segment fixation was significantly stiffer than short segment fixation, but adding index screws to the short segment construct significantly improved stability by 25%. Adding the cross-link increased stability only during axial rotation. Alternative fixation devices or techniques for the thoracic spine have been described, but pedicle screw systems still provide superior biomechanical properties [18, 26]. All relevant articles are summarized in Table 1.

Placement of thoracic pedicle screws

Transpedicular pedicle screws

Seventeen studies evaluated screw positioning, screw implantation and intra-operative control of screw placement (Table 2). The Placement of pedicle screws in the straight ahead technique promoted by Roy-Camille et al. [34] is associated with a penetrating rate of 41% [40]. Generally, structures at risk were the intercostal vessel (T4–5), esophagus (T5–9), diaphragm, azygos vein (T5–11), inferior vena cava (T11–12) on the right side as well as aorta (T5–12) and esophagus (T4–9) on the left side.
Dwahan et al. [9] analyzed the effective pedicle diameter and the mean insertion angle comparing three types of insertion techniques (straight ahead, straight forward with angulation in the axial plane, and anatomic with angulation in the axial and sagittal planes) and found the largest effective diameter using the anatomic way.
Additionally, the funnel technique, opening the insertion point to visualize the medial cortex of the lamina, was analyzed in a cadaver study [6]. The authors had a low perforating rate of 10% grade 1 and 0.4% grade 2. Another way to improve the accuracy could be the use of a special drill guide as tool for thoracic pedicle screw placement [27]. Only 5 of 66 screws had a perforation, all less than 2 mm.
Lehmann et al. [25] analyzed 229 pedicles in an anatomic study. The authors found an ideal starting point 2–3 mm lateral to the midline of the superior articular facet (line between the lateral and the middle third of the superior facet). The cephalocaudal point is more level depending. T7–9 at the cranial border of the transverse process, T6 and T10 between the cranial border and proximal one-third of transverse process, T4–5 and T11 proximal one third of transverse process and T1–3 and T12 bisected transverse process.
In a clinical setting, Bransfold et al. [4] reported of 1.2% revision surgery rate due to screw misplacement in 245 patients treated because of thoracic fractures in an open technique under fluoroscopic control. Thereby, there seems to be a correlation between pedicle diameter and penetration rate with a 33% misplacement rate in pedicle diameters of less than 5 mm to 11% in diameters between 5 and 7 mm and no misplacement in diameters above 7 mm [16]. Altogether, there seems to be no difference in accuracy of screw placement in thoracic spine between the open and percutaneous technique [23].
Two studies investigated the benefit of navigation for pedicle screw placement in the thoracic spine [35, 45]. Both studies found significant higher accuracy in the navigated pedicle screw placement technique. Alternatively, intraoperative 3D-Imaging using a cone-beam device can be used to improve accuracy [2]. A total of 3.8% of the pedicle screws were re-implanted due to the findings in the 3D-Scan. No penetration of more than 2 mm was seen postoperatively. Additionally, Fischer et al. [12] used preoperative CT-guided transpedicular guide wires and reported a high accuracy and a low complication rate.
In contrast, intraoperative electromyographic monitoring could not improve the accuracy of transpedicular screw placement in thoracic spine [31].

Parapedicular pedicle screws

The insertion of pedicle screws parapedicularly is an alternative to the transpedicular screws placement [10]. The accuracy of this technique under computer-assisted navigation was good and reliable [22].
Husted et al. [21] performed a cadaver study for the parapedicular approach. In this technique, the screws were inserted cephalad to the tip of the transverse process and advanced between the transverse process and the rib. The direction of insertion was caudad in an oblique direction following the course of the rib medially to its articulation with the vertebral body under fluoroscopic control. All screws had an extraspinal position and were positioned in the pedicle rib unit.

Translaminar screws

Alternatively, translaminar screw fixation has been evaluated, which can be inserted with high accuracy under clinically control [7].
Hu et al. [19] analyzed the laminar of the high thoracic spine (Th 1–3) in an Asian population. The authors found larger lamina in males than females but sufficient corridors in all cases.

Outcome after posterior stabilization

There were 14 clinical studies evaluating the outcome in patients with unstable thoracic fractures (Table 3). Most studies on non-operative treatment of unstable fractures are historical. They report treatment algorithms that include bedrest for 2–6 weeks [5, 17, 48]. Hospitalisation times with non-operative treatment range from 3 weeks to 3 months [5, 17] and can be reduced to between less than 2 weeks and 3 weeks by operative treatment in patients with isolated thoracic vertebral fractures [13, 14].
After surgical treatment of thoracic vertebral fractures by posterior stabilization in general, non-surgery-related complications occur in 49%–60%, especially in patients with complete or incomplete paraplegia [28, 46]. Deep venous thrombosis is observed in 4%–9% [13, 36]—compared to 24.5% in conservatively treated patients [5]. This results in an in-hospital mortality rate of 6%–8% [46, 47]. Neurologic worsening during follow-up can be reduced from around 2% [5, 48] with non-operative treatment to less than 1% with posterior stabilization [28, 29, 45, 46]. The only complication directly linked to the non-operative treatment is brace-related skin complications in 16% [5]. For surgical posterior stabilization, the need for revision surgery is reported in 0 to 22% [13, 15, 29, 36, 41, 46]. Some authors differentiate between early revision surgery in 4%–19% and late revision surgery in 16%–22%—with late revisions being mainly those for pain and low-grade-infection [13, 14, 28]. One study identified lamina hooks as source of potential neurological complications requiring revision surgery [41].
Radiological secondary deformity was seen in 94% with non-operative-management, particularly in fractures with associated injuries to the adjacent disc and/or posterior ligaments [17, 48]. With posterior stabilization, a loss of reduction of 1° to 4° was observed after 1 year and of 2° to 4° after 2 years and more [13, 14, 29, 41]. The only study reporting data on bone healing stated a fusion rate of 95% at 12 months on conventional radiographs [14].
Pain at follow-up after non-operative treatment was reported by 21% to 48% of the patients at 5 years and longer, while this was the case in 35% with a mean of VAS 3 at 15 months after operative treatment with posterior stabilization [5, 8, 17, 48]. Harkönen et al. [17] reported that 13% of the patients had “poor” mobility at 5 years with non-operative treatment, while Yue et al. [46] reported “very good to excellent levels of satisfaction with regards to pain, mobility, posture, and activity” 22 months after posterior stabilization.
Only few studies report patient-reported outcomes for operatively treated patients with values for the SF 36—PCS of 36–40 and the SF 36-MCS of 43–56 [36, 41]. No difference in functional outcome was seen between short and long segmental construct. Generally, return to work was less likely in patients with concomitant spinal cord injuries (25% of ASIA A/B/C and 88% of ASIA D/E) [36]. One year after posterior stabilization of a thoracic vertbral fracture, 7.8% received compensation payments for chronic back pain [28].
There is also some evidence that percutaneous posterior stabilization of thoracic spine fractures is associated with a reduced inflammatory response, less bleeding, shorter hospitalisation time and earlier return to activities of daily living [20, 42].

Discussion

The majority of articles that were selected had a low level of evidence (level IV). Thus, no strength of evidence and statistical precision in the evaluation of the outcomes was performed. In contrast, a narrative presentation of the results was chosen.
Based on this, the most important findings of this study are the low evidence on posterior stabilization of mid-thoracic vertebral body fractures particularly dealing with clinical outcomes can be observed. Besides, the tremendous effect of sternal integrity on spinal stability has been shown. Furthermore, the penetration rates of pedicle screws varies between the studies ranging up to 40% based on the rather small pedicle diameters at the upper thoracic spine. Thereby, the accuracy of pedicle screw placement could be improved by navigated pedicle screw insertion as well as intraoperative 3D-Imaging and the insertion should be done anatomically.
Most authors perform long-segmental posterior instrumentation in patients with mid-thoracic vertebral fractures [4, 29, 38, 41]. This seems to be necessary particularly in patients with concomitant sternal fractures [30]. Based on the findings on the association of pedicle diameters and penetration rates, navigated techniques or intraoperative 3D-Imaging should be particularly used in pedicle diameters of less than 5 mm [2, 16, 35, 45]. In small pedicles, translaminar screws at the upper thoracic spine or parapedicular screws might be a viable alternative [7, 22]. Interestingly, percutaneous techniques were not associated with higher penetration rates. Therefore, percutaneous stabilization is a very good solution in long-segmental stabilizations and polytraumatized patients based on their reduced approach-related morbidity and significantly reduced blood loss [23].
Under consideration of these results, the authors generally recommend long-segmental stabilization of unstable midthoracic fractures in patients with concomitant fractures of the rib cage, particularly sternal fractures. On the other side, comparable biomechanical construct stabilities could be seen in unstable midthoracic fractures with intact rib cages between short-segmental stabilization with index screw and cross link and long-segmental stabilization. However, it has to be kept in mind that biomechanical tests are traditionally performed under ideal conditions, including optimal pedicle screw positioning. In contrast, it has been shown that pedicle screw placement was insufficient in a relevant number of patients with small pedicle including a penetration rate of 33% in pedicle diameters of less than 5 mm [16]. This can affect the screw hold considerably leading to impaired construct stability in patients treated with short-segment stabilization. Based on the limited pedicle screw diameters at the midthoracic spine, short-segmental stabilization has to be discussed critically in this region particularly as there are no signs of any functional benefit of short-segmental stabilization [36, 38]. In the authors’ view short-segment stabilization is only a viable option in patients with large pedicle diameters, or in cases where navigation or intraoperative 3D-scans are used. In these cases, correct pedicle screw placement can be expected. Based on the biomechanical data short-segment constructs should include index screws. Additionally, cross links improve the construct stability and should be added particularly when an open approach has been used. Furthermore, pedicle screws with a diameter as large as possible and a sufficient length should be used to increase construct stability. In the authors’ experience, no pedicle screws with diameters of less than 5 mm should be inserted. Thereby, the authors recommend parapedicular screw placement in those patients with too small pedicle diameters.
Unfortunately, the evidence level of the clinical follow-up studies is low. Altogether, the results of posterior stabilization of unstable thoracic fractures are superior compared to non-operative treatment, with a lower rate of neurologic deterioration, higher return to work rates and lower limitations [28, 29, 46, 47]. However, the complication rate after both, operative and non-operative treatment is high [26, 41, 47].
This study has several limitations. First of all, articles might have been missed by the used search items. Besides, the level of evidence in the majority of studies is low, leading to a limited conclusion that can be drawn out of it. Last but not least, the high number of studies with low evidence level was the reason to present the results in a narrative manner without any statistical evaluation of the strength of evidence and the precision of outcome parameters.
Altogether, further studies are necessary to define patients who benefit from surgery as well as which surgical strategies might lead to superior mid- and long-term results.

Conclusions

The evidence of the available literature is low. Prospective randomized studies are lacking. However, long-segmental stabilization is indicated in unstable midthoracic fractures with concomitant sternal fractures. Generally, long-segmental constructs seem to be the safer treatment strategy considering the relative high penetration rate of pedicle screws in this region. In the case of short-segmental stabilization, the use of index screw can be recommended. Additionally, pedicle screws with a diameter as large as possible should be used. Thereby, navigated insertion techniques and intraoperative 3D-imaging help to improve pedicle screw placement accuracy.

Compliance with ethical standards

Conflict of interest

Georg Osterhoff is consultant for Medacta. No further conflict of interests exists.
Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Orthopädie & Unfallchirurgie

Kombi-Abonnement

Mit e.Med Orthopädie & Unfallchirurgie erhalten Sie Zugang zu CME-Fortbildungen der Fachgebiete, den Premium-Inhalten der dazugehörigen Fachzeitschriften, inklusive einer gedruckten Zeitschrift Ihrer Wahl.

Neuer Inhalt

Print-Titel

Literatur
1.
Zurück zum Zitat Bassler D, Antes G. Wie erhalte ich Antworten auf meine Fragen? In: Lehrbuch Evidenzbasierte Medizin in Klinik und Praxis. Deutscher Ärzte-Verlag, Köln. 2000. Bassler D, Antes G. Wie erhalte ich Antworten auf meine Fragen? In: Lehrbuch Evidenzbasierte Medizin in Klinik und Praxis. Deutscher Ärzte-Verlag, Köln. 2000.
2.
Zurück zum Zitat Beck M, Rotter R, Gradl G, Herlyn P, Krober M, Mittlmeier T, Gierer P. Reliability and consequences of intraoperative 3D imaging to control positions of thoracic pedicle screws. Arch Orthop Trauma Surg Archiv fur orthopadische und Unfall-Chirurgie. 2012;132(10):1371–7. https://doi.org/10.1007/s00402-012-1555-y.CrossRef Beck M, Rotter R, Gradl G, Herlyn P, Krober M, Mittlmeier T, Gierer P. Reliability and consequences of intraoperative 3D imaging to control positions of thoracic pedicle screws. Arch Orthop Trauma Surg Archiv fur orthopadische und Unfall-Chirurgie. 2012;132(10):1371–7. https://​doi.​org/​10.​1007/​s00402-012-1555-y.CrossRef
3.
Zurück zum Zitat Berg EE. The sternal-rib complex. A possible fourth column in thoracic spine fractures. Spine. 1993;18(13):16–9.CrossRef Berg EE. The sternal-rib complex. A possible fourth column in thoracic spine fractures. Spine. 1993;18(13):16–9.CrossRef
5.
Zurück zum Zitat Capen DA, Gordon ML, Zigler JE, Garland DE, Nelson RW, Nagelberg S. Nonoperative management of upper thoracic spine fractures. Orthop Rev. 1994;23(10):818–21. Capen DA, Gordon ML, Zigler JE, Garland DE, Nelson RW, Nagelberg S. Nonoperative management of upper thoracic spine fractures. Orthop Rev. 1994;23(10):818–21.
8.
Zurück zum Zitat Dai L. Thoracic spine fractures. Chin Med Sci J Chung-kuo i hsueh k’o hsueh tsa chih. 2001;16(4):227–30. Dai L. Thoracic spine fractures. Chin Med Sci J Chung-kuo i hsueh k’o hsueh tsa chih. 2001;16(4):227–30.
11.
Zurück zum Zitat Farrugia P, Petrisor BA, Farrokhyar F, Bhandari M. Practical tips for surgical research: research questions, hypotheses and objectives. Can J Surg J Canadien de Chirurgie. 2010;53(4):278–81. Farrugia P, Petrisor BA, Farrokhyar F, Bhandari M. Practical tips for surgical research: research questions, hypotheses and objectives. Can J Surg J Canadien de Chirurgie. 2010;53(4):278–81.
16.
17.
Zurück zum Zitat Harkonen M, Kataja M, Lepisto P, Paakkala T, Patiala H, Rokkanen P. Fractures of the thoracic spine. Clinical and radiological results in 98 patients. Arch Orthop Trauma Surg Archiv fur orthopadische und Unfall-Chirurgie. 1979;94(3):179–84.CrossRef Harkonen M, Kataja M, Lepisto P, Paakkala T, Patiala H, Rokkanen P. Fractures of the thoracic spine. Clinical and radiological results in 98 patients. Arch Orthop Trauma Surg Archiv fur orthopadische und Unfall-Chirurgie. 1979;94(3):179–84.CrossRef
19.
20.
Zurück zum Zitat Huckell CB, Powell J, Eggli S, Hu R. A comparative analysis of distraction rods versus Luque rods in thoracic spine fractures. Eur Spine J. 1994;3(5):270–5.CrossRef Huckell CB, Powell J, Eggli S, Hu R. A comparative analysis of distraction rods versus Luque rods in thoracic spine fractures. Eur Spine J. 1994;3(5):270–5.CrossRef
22.
Zurück zum Zitat Kothe R, Matthias Strauss J, Deuretzbacher G, Hemmi T, Lorenzen M, Wiesner L. Computer navigation of parapedicular screw fixation in the thoracic spine: a cadaver study. Spine. 2001;26(21):E496-501.CrossRef Kothe R, Matthias Strauss J, Deuretzbacher G, Hemmi T, Lorenzen M, Wiesner L. Computer navigation of parapedicular screw fixation in the thoracic spine: a cadaver study. Spine. 2001;26(21):E496-501.CrossRef
31.
Zurück zum Zitat Reidy DP, Houlden D, Nolan PC, Kim M, Finkelstein JA. Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws. J Bone Jt Surg Br. 2001;83(7):1009–14.CrossRef Reidy DP, Houlden D, Nolan PC, Kim M, Finkelstein JA. Evaluation of electromyographic monitoring during insertion of thoracic pedicle screws. J Bone Jt Surg Br. 2001;83(7):1009–14.CrossRef
32.
Zurück zum Zitat Reinhold M, Knop C, Beisse R, Audige L, Kandziora F, Pizanis A, Pranzl R, Gercek E, Schultheiss M, Weckbach A, Buhren V, Blauth M. [Operative treatment of traumatic fractures of the thoracic and lumbar spinal column. Part I: epidemiology]. Der Unfallchirurg. 2009;112(1):33–42, 44–35. https://doi.org/10.1007/s00113-008-1524-7 Reinhold M, Knop C, Beisse R, Audige L, Kandziora F, Pizanis A, Pranzl R, Gercek E, Schultheiss M, Weckbach A, Buhren V, Blauth M. [Operative treatment of traumatic fractures of the thoracic and lumbar spinal column. Part I: epidemiology]. Der Unfallchirurg. 2009;112(1):33–42, 44–35. https://​doi.​org/​10.​1007/​s00113-008-1524-7
34.
Zurück zum Zitat Roy-Camille R, Saillant G, Berteaux D, Salgado V. Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles. Reconstr Surg Traumatol. 1976;15:2–16. Roy-Camille R, Saillant G, Berteaux D, Salgado V. Osteosynthesis of thoraco-lumbar spine fractures with metal plates screwed through the vertebral pedicles. Reconstr Surg Traumatol. 1976;15:2–16.
43.
Zurück zum Zitat Rt W, Watkins R 3rd, Williams L, Ahlbrand S, Garcia R, Karamanian A, Sharp L, Vo C, Hedman T. Stability provided by the sternum and rib cage in the thoracic spine. Spine. 2005;30(11):1283–6.CrossRef Rt W, Watkins R 3rd, Williams L, Ahlbrand S, Garcia R, Karamanian A, Sharp L, Vo C, Hedman T. Stability provided by the sternum and rib cage in the thoracic spine. Spine. 2005;30(11):1283–6.CrossRef
44.
Zurück zum Zitat White AA, Panjabi MM. Clinical biomechanics of the spine, vol. 2. Philadelphia: JB Lippincott Company; 1990. White AA, Panjabi MM. Clinical biomechanics of the spine, vol. 2. Philadelphia: JB Lippincott Company; 1990.
45.
Zurück zum Zitat Wu H, Gao ZL, Wang JC, Li YP, Xia P, Jiang R. Pedicle screw placement in the thoracic spine: a randomized comparison study of computer-assisted navigation and conventional techniques. Chin J Traumatol Zhonghua Chuang Shang za zhi. 2010;13(4):201–5.PubMed Wu H, Gao ZL, Wang JC, Li YP, Xia P, Jiang R. Pedicle screw placement in the thoracic spine: a randomized comparison study of computer-assisted navigation and conventional techniques. Chin J Traumatol Zhonghua Chuang Shang za zhi. 2010;13(4):201–5.PubMed
48.
Zurück zum Zitat Zifko B, Schodl F, Holzmuller H. Conservative treatment of fractures of the thoracic spine. Hefte zur Unfallheilkunde. 1971;108:84–7. Zifko B, Schodl F, Holzmuller H. Conservative treatment of fractures of the thoracic spine. Hefte zur Unfallheilkunde. 1971;108:84–7.
Metadaten
Titel
Biomechanics and clinical outcome after posterior stabilization of mid-thoracic vertebral body fractures: a systematic literature review
verfasst von
Ulrich J. Spiegl
Georg Osterhoff
Philipp Bula
Frank Hartmann
Max J. Scheyerer
Klaus J. Schnake
Bernhard W. Ullrich
Publikationsdatum
02.12.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 5/2021
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-020-01560-5

Weitere Artikel der Ausgabe 5/2021

European Journal of Trauma and Emergency Surgery 5/2021 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.