Skip to main content
Erschienen in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie 6/2019

27.03.2019 | Editorials

Blind intubation using supraglottic devices: why should we even try?

verfasst von: Ruediger R. Noppens, MD, PhD, FEAMS, FRCPC, James Pius, MD

Erschienen in: Canadian Journal of Anesthesia/Journal canadien d'anesthésie | Ausgabe 6/2019

Einloggen, um Zugang zu erhalten

Excerpt

For years, clinicians have performed intubation of the trachea through various supraglottic airways (SGAs). As opposed to the purpose-designed LMA® Fastrach™ (Teleflex; Wayne, PA, USA) SGA, intubation through a regular SGA that is not specifically designed for this—which can be problematic. Potential for folding of the SGA tip and anatomical misplacements of the SGA are some of the reasons for failed blind intubation. Consequently, it is often recommended that endotracheal intubation is done with the assistance of direct flexible endoscopic visualization. A question that naturally arises from this, is whether there is ever a role for blindly performing tracheal intubation via an SGA without direct visualization? …
Literatur
3.
Zurück zum Zitat Timmermann A, Russo SG, Crozier TA, et al. Novices ventilate and intubate quicker and safer via intubating laryngeal mask than by conventional bag-mask ventilation and laryngoscopy. Anesthesiology 2007; 107: 570-6.CrossRefPubMed Timmermann A, Russo SG, Crozier TA, et al. Novices ventilate and intubate quicker and safer via intubating laryngeal mask than by conventional bag-mask ventilation and laryngoscopy. Anesthesiology 2007; 107: 570-6.CrossRefPubMed
4.
Zurück zum Zitat Ahn E, Choi G, Kang H, et al. Supraglottic airway devices as a strategy for unassisted tracheal intubation: a network meta-analysis. PLoS One 2018; 13: e0206804.CrossRefPubMedCentralPubMed Ahn E, Choi G, Kang H, et al. Supraglottic airway devices as a strategy for unassisted tracheal intubation: a network meta-analysis. PLoS One 2018; 13: e0206804.CrossRefPubMedCentralPubMed
5.
Zurück zum Zitat Piepho T, Cavus E, Noppens R, et al. S1 guidelines on airway management: Guideline of the German Society of Anesthesiology and Intensive Care Medicine 2015; 64 Suppl 1: 27-40. Piepho T, Cavus E, Noppens R, et al. S1 guidelines on airway management: Guideline of the German Society of Anesthesiology and Intensive Care Medicine 2015; 64 Suppl 1: 27-40.
6.
Zurück zum Zitat Law JA, Broemling N, Cooper RM, et al. The difficult airway with recommendations for management–part 1–difficult tracheal intubation encountered in an unconscious/induced patient. Can J Anesth 2013; 60: 1089-118.CrossRefPubMed Law JA, Broemling N, Cooper RM, et al. The difficult airway with recommendations for management–part 1–difficult tracheal intubation encountered in an unconscious/induced patient. Can J Anesth 2013; 60: 1089-118.CrossRefPubMed
7.
Zurück zum Zitat Berkow LC, Schwartz JM, Kan K, Corridore M, Heitmiller ES. Use of the Laryngeal Mask Airway-Aintree Intubating Catheter-fiberoptic bronchoscope technique for difficult intubation. J Clin Anesth 2011; 23: 534-9.CrossRefPubMed Berkow LC, Schwartz JM, Kan K, Corridore M, Heitmiller ES. Use of the Laryngeal Mask Airway-Aintree Intubating Catheter-fiberoptic bronchoscope technique for difficult intubation. J Clin Anesth 2011; 23: 534-9.CrossRefPubMed
Metadaten
Titel
Blind intubation using supraglottic devices: why should we even try?
verfasst von
Ruediger R. Noppens, MD, PhD, FEAMS, FRCPC
James Pius, MD
Publikationsdatum
27.03.2019
Verlag
Springer International Publishing
Erschienen in
Canadian Journal of Anesthesia/Journal canadien d'anesthésie / Ausgabe 6/2019
Print ISSN: 0832-610X
Elektronische ISSN: 1496-8975
DOI
https://doi.org/10.1007/s12630-019-01352-5

Weitere Artikel der Ausgabe 6/2019

Canadian Journal of Anesthesia/Journal canadien d'anesthésie 6/2019 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.