Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 5/2018

14.02.2017 | Knee

Bone–femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty

verfasst von: Shinichi Kuriyama, Katsufumi Hyakuna, Satoshi Inoue, Yasutsugu Kawai, Yasuyuki Tamaki, Hiromu Ito, Shuichi Matsuda

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 5/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study retrospectively evaluated the fate of mismatch between an uncemented femoral component and each femoral cut surface (i.e., wedge-shaped gap) relative to sagittal mechanical alignment in total knee arthroplasty (TKA).

Methods

Primary TKA was performed on 99 consecutive knees. The femoral components were aligned to the sagittal mechanical axis with CT-based navigation. All patients were assessed with postoperative true lateral radiographs. Bone-side surfaces of the uncemented femoral component were divided into five zones: anterior flange, anterior chamfer, posterior chamfer, posterior part, and distal part, which were defined as zones 1 to 5, respectively. Bone filling of wedge-shaped gaps in each zone was evaluated after 1 year.

Results

Femoral anterior notching did not occur. However, wedge-shaped gaps were observed in at least one zone in 23 of 99 knees (23%), most frequently in zone 5 (18%). There were 9 and 7 gaps in zones 1 and 2, respectively. The femoral component showed malpositioning of approximately 3° of flexion in cases with wedge-shaped gaps in zones 2 and/or 5. After one year, 67% (6/9) of zone 1, 100% (7/7) of zone 2, and 94% (17/18) of zone 5 wedge-shaped gaps were filled in with new bone.

Conclusions

Femoral alignment relative to sagittal mechanical axis caused wedge-shaped gaps due to unstable anterior bone cutting through hard bone, but the small gaps were not clinically significant and filled in within one year. Sagittal setting of the femoral component should aim for the anatomical axis rather than the mechanical axis.

Level of evidence

IV.
Literatur
1.
Zurück zum Zitat Antony J, Tetsworth K, Hohmann E (2016) Influence of sagittal plane component alignment on kinematics after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-016-4098-x PubMed Antony J, Tetsworth K, Hohmann E (2016) Influence of sagittal plane component alignment on kinematics after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-016-4098-x PubMed
2.
Zurück zum Zitat Banks SA, Harman MK, Hodge WA (2002) Mechanism of anterior impingement damage in total knee arthroplasty. J Bone Joint Surg Am 84:37–42CrossRefPubMed Banks SA, Harman MK, Hodge WA (2002) Mechanism of anterior impingement damage in total knee arthroplasty. J Bone Joint Surg Am 84:37–42CrossRefPubMed
3.
Zurück zum Zitat Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47 Berger RA, Rubash HE, Seel MJ, Thompson WH, Crossett LS (1993) Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis. Clin Orthop Relat Res 286:40–47
4.
Zurück zum Zitat Callaghan JJ, O’Rourke MR, Goetz DD, Schmalzried TP, Campbell PA, Johnston RC (2002) Tibial post impingement in posterior-stabilized total knee arthroplasty. Clin Orthop Relat Res 404:83–88CrossRef Callaghan JJ, O’Rourke MR, Goetz DD, Schmalzried TP, Campbell PA, Johnston RC (2002) Tibial post impingement in posterior-stabilized total knee arthroplasty. Clin Orthop Relat Res 404:83–88CrossRef
5.
Zurück zum Zitat Culp RW, Schmidt RG, Hanks G, Mak A, Esterhai JL Jr, Heppenstall RB (1987) Supracondylar fracture of the femur following prosthetic knee arthroplasty. Clin Orthop Relat Res 222:212–222 Culp RW, Schmidt RG, Hanks G, Mak A, Esterhai JL Jr, Heppenstall RB (1987) Supracondylar fracture of the femur following prosthetic knee arthroplasty. Clin Orthop Relat Res 222:212–222
6.
Zurück zum Zitat Chen JY, Yeo SJ, Yew AK, Tay DK, Chia SL, Lo NN, Chin PL (2014) The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:630–635CrossRefPubMed Chen JY, Yeo SJ, Yew AK, Tay DK, Chia SL, Lo NN, Chin PL (2014) The radiological outcomes of patient-specific instrumentation versus conventional total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:630–635CrossRefPubMed
7.
Zurück zum Zitat Chen S, Zeng Y, Yan M, Yue B, Zhang J, Wang Y (2016) Morphological evaluation of the sagittal plane femoral load-bearing surface in computer-simulated virtual total knee arthroplasty implantation at different flexion angles. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-016-3997-1 Chen S, Zeng Y, Yan M, Yue B, Zhang J, Wang Y (2016) Morphological evaluation of the sagittal plane femoral load-bearing surface in computer-simulated virtual total knee arthroplasty implantation at different flexion angles. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-016-3997-1
8.
Zurück zum Zitat Chiu YS, Chen WM, Huang CK, Chiang CC, Chen TH (2004) Fracture of the polyethylene tibial post in a NexGen posterior-stabilized knee prosthesis. J Arthroplast 19:1045–1049CrossRef Chiu YS, Chen WM, Huang CK, Chiang CC, Chen TH (2004) Fracture of the polyethylene tibial post in a NexGen posterior-stabilized knee prosthesis. J Arthroplast 19:1045–1049CrossRef
9.
Zurück zum Zitat Clarke HD, Math KR, Scuderi GR (2004) Polyethylene post failure in posterior stabilized total knee arthroplasty. J Arthroplast 19:652–657CrossRef Clarke HD, Math KR, Scuderi GR (2004) Polyethylene post failure in posterior stabilized total knee arthroplasty. J Arthroplast 19:652–657CrossRef
10.
Zurück zum Zitat Collier MB, Engh CA Jr, McAuley JP, Ginn SD, Engh GA (2005) Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively. J Bone Joint Surg Am 87:2702–2708PubMed Collier MB, Engh CA Jr, McAuley JP, Ginn SD, Engh GA (2005) Osteolysis after total knee arthroplasty: influence of tibial baseplate surface finish and sterilization of polyethylene insert. Findings at five to ten years postoperatively. J Bone Joint Surg Am 87:2702–2708PubMed
11.
Zurück zum Zitat Duffy GP, Murray BE, Trousdale RR (2007) Hybrid total knee arthroplasty analysis of component failures at an average of 15 years. J Arthroplasty 22:1112–1115CrossRefPubMed Duffy GP, Murray BE, Trousdale RR (2007) Hybrid total knee arthroplasty analysis of component failures at an average of 15 years. J Arthroplasty 22:1112–1115CrossRefPubMed
12.
Zurück zum Zitat Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12 Ewald FC (1989) The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop Relat Res 248:9–12
13.
Zurück zum Zitat Faris PM, Keating EM, Farris A, Meding JB, Ritter MA (2008) Hybrid total knee arthroplasty: 13-year survivorship of AGC total knee systems with average 7 years followup. Clin Orthop Relat Res 466:1204–1209CrossRefPubMedPubMedCentral Faris PM, Keating EM, Farris A, Meding JB, Ritter MA (2008) Hybrid total knee arthroplasty: 13-year survivorship of AGC total knee systems with average 7 years followup. Clin Orthop Relat Res 466:1204–1209CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Hamai S, Miura H, Higaki H, Shimoto T, Matsuda S, Iwamoto Y (2008) Evaluation of impingement of the anterior tibial post during gait in a posteriorly-stabilised total knee replacement. J Bone Joint Surg Br 90:1180–1185CrossRefPubMed Hamai S, Miura H, Higaki H, Shimoto T, Matsuda S, Iwamoto Y (2008) Evaluation of impingement of the anterior tibial post during gait in a posteriorly-stabilised total knee replacement. J Bone Joint Surg Br 90:1180–1185CrossRefPubMed
15.
Zurück zum Zitat Huang TW, Peng KT, Huang KC, Lee MS, Hsu RW (2014) Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:2954–2961CrossRefPubMed Huang TW, Peng KT, Huang KC, Lee MS, Hsu RW (2014) Differences in component and limb alignment between computer-assisted and conventional surgery total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 22:2954–2961CrossRefPubMed
16.
Zurück zum Zitat Huddleston JI, Wiley JW, Scott RD (2005) Zone 4 femoral radiolucent lines in hybrid versus cemented total knee arthroplasties: are they clinically significant? Clin Orthop Relat Res 441:334–339CrossRefPubMed Huddleston JI, Wiley JW, Scott RD (2005) Zone 4 femoral radiolucent lines in hybrid versus cemented total knee arthroplasties: are they clinically significant? Clin Orthop Relat Res 441:334–339CrossRefPubMed
17.
Zurück zum Zitat Illgen R, Tueting J, Enright T, Schreibman K, McBeath A, Heiner J (2004) Hybrid total knee arthroplasty: a retrospective analysis of clinical and radiographic outcomes at average 10 years follow-up. J Arthroplast 19:95–100CrossRef Illgen R, Tueting J, Enright T, Schreibman K, McBeath A, Heiner J (2004) Hybrid total knee arthroplasty: a retrospective analysis of clinical and radiographic outcomes at average 10 years follow-up. J Arthroplast 19:95–100CrossRef
18.
Zurück zum Zitat Kawahara S, Matsuda S, Fukagawa S, Mitsuyasu H, Nakahara H, Higaki H, Shimoto T, Iwamoto Y (2012) Upsizing the femoral component increases patellofemoral contact force in total knee replacement. J Bone Joint Surg Br 94:56–61CrossRefPubMed Kawahara S, Matsuda S, Fukagawa S, Mitsuyasu H, Nakahara H, Higaki H, Shimoto T, Iwamoto Y (2012) Upsizing the femoral component increases patellofemoral contact force in total knee replacement. J Bone Joint Surg Br 94:56–61CrossRefPubMed
19.
Zurück zum Zitat Keshmiri A, Springorum HR, Baier C, Zeman F, Grifka J, Maderbacher G (2016) Changes in sagittal component alignment alters patellar kinematics in TKA: an in vitro study. Knee Surg Sports Traumatol Arthrosc 24:823–829CrossRefPubMed Keshmiri A, Springorum HR, Baier C, Zeman F, Grifka J, Maderbacher G (2016) Changes in sagittal component alignment alters patellar kinematics in TKA: an in vitro study. Knee Surg Sports Traumatol Arthrosc 24:823–829CrossRefPubMed
20.
Zurück zum Zitat Kim YH, Kim JS, Yoon SH (2007) Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br 89:471–476CrossRefPubMed Kim YH, Kim JS, Yoon SH (2007) Alignment and orientation of the components in total knee replacement with and without navigation support: a prospective, randomised study. J Bone Joint Surg Br 89:471–476CrossRefPubMed
21.
Zurück zum Zitat Ko JH, Han CD, Shin KH, Nguku L, Yang IH, Lee WS, Kim KI, Park KK (2016) Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24:2476–2482CrossRefPubMed Ko JH, Han CD, Shin KH, Nguku L, Yang IH, Lee WS, Kim KI, Park KK (2016) Femur bowing could be a risk factor for implant flexion in conventional total knee arthroplasty and notching in navigated total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 24:2476–2482CrossRefPubMed
22.
Zurück zum Zitat Lee CS, Chen WM, Kou HC, Lo WH, Chen CL (2009) Early nontraumatic fracture of the polyethylene tibial post in a NexGen LPS-Flex posterior stabilized kneeprosthesis. J Arthroplasty 24(1292):e5–e9 Lee CS, Chen WM, Kou HC, Lo WH, Chen CL (2009) Early nontraumatic fracture of the polyethylene tibial post in a NexGen LPS-Flex posterior stabilized kneeprosthesis. J Arthroplasty 24(1292):e5–e9
24.
Zurück zum Zitat Lustig S, Scholes CJ, Stegeman TJ, Oussedik S, Coolican MR, Parker DA (2012) Sagittal placement of the femoral component in total knee arthroplasty predicts knee flexion contracture at one-year follow-up. Int Orthop 36:1835–1839CrossRefPubMedPubMedCentral Lustig S, Scholes CJ, Stegeman TJ, Oussedik S, Coolican MR, Parker DA (2012) Sagittal placement of the femoral component in total knee arthroplasty predicts knee flexion contracture at one-year follow-up. Int Orthop 36:1835–1839CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Melton JT, Mayahi R, Baxter SE, Facek M, Glezos C (2012) Long-term outcome in an uncemented, hydroxyapatite-coated total knee replacement: a 15- to 18-year survivorship analysis. J Bone Joint Surg Br 94:1067–1070CrossRefPubMed Melton JT, Mayahi R, Baxter SE, Facek M, Glezos C (2012) Long-term outcome in an uncemented, hydroxyapatite-coated total knee replacement: a 15- to 18-year survivorship analysis. J Bone Joint Surg Br 94:1067–1070CrossRefPubMed
26.
Zurück zum Zitat Minoda Y, Kobayashi A, Iwaki H, Mitsuhiko I, Kadoya Y, Ohashi H, Takaoka K, Nakamura H (2010) The risk of notching the anterior femoral cortex with the use of navigation systems in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 18:718–722CrossRefPubMed Minoda Y, Kobayashi A, Iwaki H, Mitsuhiko I, Kadoya Y, Ohashi H, Takaoka K, Nakamura H (2010) The risk of notching the anterior femoral cortex with the use of navigation systems in total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 18:718–722CrossRefPubMed
27.
Zurück zum Zitat Minoda Y, Kobayashi A, Iwaki H, Ohashi H, Takaoka K (2009) TKA sagittal alignment with navigation systems and conventional techniques vary only a few degrees. Clin Orthop Relat Res 467:1000–1006CrossRefPubMed Minoda Y, Kobayashi A, Iwaki H, Ohashi H, Takaoka K (2009) TKA sagittal alignment with navigation systems and conventional techniques vary only a few degrees. Clin Orthop Relat Res 467:1000–1006CrossRefPubMed
28.
Zurück zum Zitat Minoda Y, Kobayashi A, Iwaki H, Sugama R, Iwakiri K, Kadoya Y, Ohashi H, Takaoka K (2008) Sagittal alignment of the lower extremity while standing in Japanese male. Arch Orthop Trauma Surg 128:435–442CrossRefPubMed Minoda Y, Kobayashi A, Iwaki H, Sugama R, Iwakiri K, Kadoya Y, Ohashi H, Takaoka K (2008) Sagittal alignment of the lower extremity while standing in Japanese male. Arch Orthop Trauma Surg 128:435–442CrossRefPubMed
29.
Zurück zum Zitat Minoda Y, Watanabe K, Iwaki H, Takahashi S, Fukui M, Nakamura H (2013) Theoretical risk of anterior femoral cortex notching in total knee arthroplasty using a navigation system. J Arthroplast 28:1533–1537CrossRef Minoda Y, Watanabe K, Iwaki H, Takahashi S, Fukui M, Nakamura H (2013) Theoretical risk of anterior femoral cortex notching in total knee arthroplasty using a navigation system. J Arthroplast 28:1533–1537CrossRef
30.
Zurück zum Zitat Mizu-uchi H, Matsuda S, Miura H, Okazaki K, Akasaki Y, Iwamoto Y (2008) The evaluation of post-operative alignment in total knee replacement using a CT-based navigation system. J Bone Joint Surg Br 90:1025–1031CrossRefPubMed Mizu-uchi H, Matsuda S, Miura H, Okazaki K, Akasaki Y, Iwamoto Y (2008) The evaluation of post-operative alignment in total knee replacement using a CT-based navigation system. J Bone Joint Surg Br 90:1025–1031CrossRefPubMed
31.
Zurück zum Zitat Murphy M, Journeaux S, Hides J, Russell T (2014) Does flexion of the femoral implant in total knee arthroplasty increase knee flexion: a randomised controlled trial. Knee 21:257–263CrossRefPubMed Murphy M, Journeaux S, Hides J, Russell T (2014) Does flexion of the femoral implant in total knee arthroplasty increase knee flexion: a randomised controlled trial. Knee 21:257–263CrossRefPubMed
32.
Zurück zum Zitat Nakahara H, Matsuda S, Okazaki K, Tashiro Y, Iwamoto Y (2012) Sagittal cutting error changes femoral anteroposterior sizing in total knee arthroplasty. Clin Orthop Relat Res 470:3560–3565CrossRefPubMedPubMedCentral Nakahara H, Matsuda S, Okazaki K, Tashiro Y, Iwamoto Y (2012) Sagittal cutting error changes femoral anteroposterior sizing in total knee arthroplasty. Clin Orthop Relat Res 470:3560–3565CrossRefPubMedPubMedCentral
33.
Zurück zum Zitat Sugama R, Minoda Y, Kobayashi A, Iwaki H, Ikebuchi M, Hashimoto Y, Takaoka K, Nakamura H (2011) Sagittal alignment of the lower extremity while standing in female. Knee Surg Sports Traumatol Arthrosc 19:74–79CrossRefPubMed Sugama R, Minoda Y, Kobayashi A, Iwaki H, Ikebuchi M, Hashimoto Y, Takaoka K, Nakamura H (2011) Sagittal alignment of the lower extremity while standing in female. Knee Surg Sports Traumatol Arthrosc 19:74–79CrossRefPubMed
34.
Zurück zum Zitat Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2014) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res 472:263–271CrossRefPubMed Victor J, Dujardin J, Vandenneucker H, Arnout N, Bellemans J (2014) Patient-specific guides do not improve accuracy in total knee arthroplasty: a prospective randomized controlled trial. Clin Orthop Relat Res 472:263–271CrossRefPubMed
35.
Zurück zum Zitat Yang JH, Yoon JR, Oh CH, Kim TS (2012) Hybrid component fixation in total knee arthroplasty: minimum of 10-year follow-up study. J Arthroplast 27:1111–1118CrossRef Yang JH, Yoon JR, Oh CH, Kim TS (2012) Hybrid component fixation in total knee arthroplasty: minimum of 10-year follow-up study. J Arthroplast 27:1111–1118CrossRef
Metadaten
Titel
Bone–femoral component interface gap after sagittal mechanical axis alignment is filled with new bone after cementless total knee arthroplasty
verfasst von
Shinichi Kuriyama
Katsufumi Hyakuna
Satoshi Inoue
Yasutsugu Kawai
Yasuyuki Tamaki
Hiromu Ito
Shuichi Matsuda
Publikationsdatum
14.02.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 5/2018
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-017-4452-7

Weitere Artikel der Ausgabe 5/2018

Knee Surgery, Sports Traumatology, Arthroscopy 5/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.