Skip to main content
Erschienen in: European Spine Journal 3/2010

01.03.2010 | Original Article

C1 lateral mass screw-induced occipital neuralgia: a report of two cases

verfasst von: Eimear Conroy, Alan Laing, Rory Kenneally, A. R. Poynton

Erschienen in: European Spine Journal | Ausgabe 3/2010

Einloggen, um Zugang zu erhalten

Abstract

C1–2 polyaxial screw-rod fixation is a relatively new technique. While recognizing the potential for inadvertent vertebral artery injury, there have been few reports in the literature outlining all the possible complications. Aim of this study is to review all cases of C1 lateral mass screws insertion with emphasis on the evaluation of potential structures at risk during the procedure. We retrospectively reviewed all patients in our unit who had C1 lateral mass screw insertion over a 2-year period. The C1 lateral mass screw was inserted as part of an atlantoaxial stabilization or incorporated into a modular occiput/subaxial construct. Outcome measures included clinical and radiological parameters. Clinical indicators included age, gender, neurologic status, surgical indication and the number of levels stabilized. Intraoperative complications including blood loss, vertebral artery injury or dural tears were recorded. Postoperative pain distribution and neurological deficit were recorded. Radiological indicators included postoperative plain radiographs to assess sagittal alignment and to check for screw malposition or construct failure. A total of 18 lateral mass screws were implanted in 9 patients. There were three male and six female patients who had C1 lateral mass screw insertion in this unit. Two patients had atlantoaxial stabilization for C2 fracture. There were four patients with rheumatoid arthritis whose C1 lateral mass screws were inserted as part of an occipitocervical or subaxial cervical stabilization. There was no vertebral artery injury, no cerebrospinal fluid leak and minimal blood loss in all patients. Three patients developed postoperative occipital neuralgia. This neuralgia was transient, in one of the patients having settled at 6-week follow-up. In the other two patients the neuralgia was unresolved at time of latest follow-up but was adequately controlled with appropriate pain management. Postoperatively no patient had radiographic evidence of construct failure and all demonstrated excellent sagittal alignment. It has been reported that the absence of threads on the upper portion of the long shank screw may protect against neural irritation. However, insertion of the C1 lateral mass screw necessitates careful caudal retraction of the C2 dorsal root ganglion. The insertion point for the C1 lateral mass screw is at the junction of the C1 posterior arch and the midpoint of the posterior inferior part of the C1 lateral mass. Two patients in our series suffered occipital neuralgia post-insertion of C1 lateral mass screws. This highlights the potential for damage to the C2 nerve root during C1 lateral mass screw placement.
Literatur
1.
Zurück zum Zitat Currier BL, Yaszemski ML (2004) The use of C1 lateral mass fixation in the cervical spine. Curr Opin Orthop 15:184–191CrossRef Currier BL, Yaszemski ML (2004) The use of C1 lateral mass fixation in the cervical spine. Curr Opin Orthop 15:184–191CrossRef
2.
Zurück zum Zitat Fiore AJ, Haid RW, Rodts GE, Subach BR, Mummaneni PV, Riedel CJ, Birch BD (2002) Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series. Neurosurg Focus 12(1):E5CrossRefPubMed Fiore AJ, Haid RW, Rodts GE, Subach BR, Mummaneni PV, Riedel CJ, Birch BD (2002) Atlantal lateral mass screws for posterior spinal reconstruction: technical note and case series. Neurosurg Focus 12(1):E5CrossRefPubMed
3.
Zurück zum Zitat Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129:47–53CrossRef Goel A, Laheri V (1994) Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien) 129:47–53CrossRef
4.
Zurück zum Zitat Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51:1351–1357CrossRefPubMed Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51:1351–1357CrossRefPubMed
5.
Zurück zum Zitat Grob D, Jeanneret B, Aebi M, Markwalder TM (1991) Atlanto-axial fusion with transarticular screw fixation. J Bone Jt Surg Br 73:972–976 Grob D, Jeanneret B, Aebi M, Markwalder TM (1991) Atlanto-axial fusion with transarticular screw fixation. J Bone Jt Surg Br 73:972–976
6.
Zurück zum Zitat Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine 26:2467–2471CrossRefPubMed Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine 26:2467–2471CrossRefPubMed
7.
Zurück zum Zitat Henriques T, Cunningham BW, Olerud C et al (2002) Biomechanical comparison of five different atlantoaxial posterior fixation techniques. Spine 25:2877–2883CrossRef Henriques T, Cunningham BW, Olerud C et al (2002) Biomechanical comparison of five different atlantoaxial posterior fixation techniques. Spine 25:2877–2883CrossRef
8.
Zurück zum Zitat Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86:961–968CrossRefPubMed Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86:961–968CrossRefPubMed
9.
Zurück zum Zitat Melcher RP, Puttlitz CM, Kleinstueck FS et al (2002) Biomechanical testing of posterior atlantoaxial fixation techniques. Spine 27:2435–2440CrossRefPubMed Melcher RP, Puttlitz CM, Kleinstueck FS et al (2002) Biomechanical testing of posterior atlantoaxial fixation techniques. Spine 27:2435–2440CrossRefPubMed
10.
Zurück zum Zitat Rhee WT, You SH, Kim SK, Lee SY (2008) Troublesome occipital neuralgia developed by c1–c2 harms construct. J Korean Neurosurg Soc 43(2):111–113CrossRefPubMed Rhee WT, You SH, Kim SK, Lee SY (2008) Troublesome occipital neuralgia developed by c1–c2 harms construct. J Korean Neurosurg Soc 43(2):111–113CrossRefPubMed
11.
Zurück zum Zitat Smith MD, Kotzar G, Yoo J et al (1993) A biomechanical analysis of atlantoaxial stabilization methods using a bovine model: C1/2 fixation analysis. Clin Orthop Relat Res 290:285–295PubMed Smith MD, Kotzar G, Yoo J et al (1993) A biomechanical analysis of atlantoaxial stabilization methods using a bovine model: C1/2 fixation analysis. Clin Orthop Relat Res 290:285–295PubMed
12.
Zurück zum Zitat Stokes JK, Villavicencio AT, Liu PC et al (2002) Posterior atlantoaxial stabilization: new alternative to C1–2 transarticular screws. Neurosurg Focus 12(1):E6CrossRefPubMed Stokes JK, Villavicencio AT, Liu PC et al (2002) Posterior atlantoaxial stabilization: new alternative to C1–2 transarticular screws. Neurosurg Focus 12(1):E6CrossRefPubMed
Metadaten
Titel
C1 lateral mass screw-induced occipital neuralgia: a report of two cases
verfasst von
Eimear Conroy
Alan Laing
Rory Kenneally
A. R. Poynton
Publikationsdatum
01.03.2010
Verlag
Springer-Verlag
Erschienen in
European Spine Journal / Ausgabe 3/2010
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-009-1178-3

Weitere Artikel der Ausgabe 3/2010

European Spine Journal 3/2010 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.