Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 4/2019

10.07.2018 | Original Research

Can variable practice habits and injection port dead-volume put patients at risk?

verfasst von: Michael T. Kuntz, Roman Dudaryk, Richard R. McNeer

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

Injection ports used to administer medications and draw blood samples have inherent dead-volume. This volume can potentially lead to inadvertent drug administration, contribute to erroneous laboratory values by dilution of blood samples, and increase the risk of vascular air embolism. We sought to characterize provider practice in management of intravenous (IV) and arterial lines and measure dead-volumes of various injection ports. A survey was circulated to anesthesiology physicians and nurses to determine practice habits when administering medications and drawing blood samples. Dead-volume of one and four-way injection ports was determined by injecting methylene blue to simulate medication administration or blood sample aspiration and using absorption spectroscopy to measure sample concentration. Among the 65 survey respondents, most (64.52%) increase mainstream flow rate to flush medication given by a 1-way injection port. When using 4-way stopcocks, 56.45% flush through the same injection site. To obtain a sample from an arterial line, 67.74% draw back blood and collect the sample from the same 4-way stopcock; 32.26% use a different stopcock. Mean (SD) dead-volume in microliters ranged from 0.1 (0.0) to 5.6 (1.0) in 1-way injection ports and from 54.1 (2.8) to 126.5 (8.3) in 4-way injection ports. The practices of our providers when giving medications and drawing blood samples are variable. The dead-volume associated with injection ports used at our institution may be clinically significant, increasing errors in medication delivery and laboratory analysis.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Smart NG. The functional deadspace of needle-free injection ports. Anaesth Intensive Care. 1991;19(3):429–33.CrossRefPubMed Smart NG. The functional deadspace of needle-free injection ports. Anaesth Intensive Care. 1991;19(3):429–33.CrossRefPubMed
2.
Zurück zum Zitat Gould T, Roberts RJ. Therapeutic problems arising from the use of the intravenous route for drug administration. J Pediatr. 1979;95(3):465–71.CrossRefPubMed Gould T, Roberts RJ. Therapeutic problems arising from the use of the intravenous route for drug administration. J Pediatr. 1979;95(3):465–71.CrossRefPubMed
3.
Zurück zum Zitat Lovich MA, Doles J, Peterfreund RA. The impact of carrier flow rate and infusion set dead-volume on the dynamics of intravenous drug delivery. Anesth Analg. 2005;100(4):1048–55.CrossRefPubMed Lovich MA, Doles J, Peterfreund RA. The impact of carrier flow rate and infusion set dead-volume on the dynamics of intravenous drug delivery. Anesth Analg. 2005;100(4):1048–55.CrossRefPubMed
4.
Zurück zum Zitat Lovich MA, Kinnealley ME, Sims NM, Peterfreund RA. The delivery of drugs to patients by continuous intravenous infusion: modeling predicts potential dose fluctuations depending on flow rates and infusion system dead volume. Anesth Analg. 2006;102(4):1147–53.CrossRefPubMed Lovich MA, Kinnealley ME, Sims NM, Peterfreund RA. The delivery of drugs to patients by continuous intravenous infusion: modeling predicts potential dose fluctuations depending on flow rates and infusion system dead volume. Anesth Analg. 2006;102(4):1147–53.CrossRefPubMed
9.
Zurück zum Zitat Casella SJ, Mongilio MK, Plotnick LP, Hesterberg MP, Long CA. Accuracy and precision of low-dose insulin administration. Pediatrics. 1993;91(6):1155–7.PubMed Casella SJ, Mongilio MK, Plotnick LP, Hesterberg MP, Long CA. Accuracy and precision of low-dose insulin administration. Pediatrics. 1993;91(6):1155–7.PubMed
14.
Zurück zum Zitat Brull SJ, Prielipp RC. Vascular air embolism: a silent hazard to patient safety. J Crit Care. 2017;42:255–63.CrossRefPubMed Brull SJ, Prielipp RC. Vascular air embolism: a silent hazard to patient safety. J Crit Care. 2017;42:255–63.CrossRefPubMed
17.
Zurück zum Zitat Murphy GS, Szokol JW, Marymont JH, Avram MJ, Vender JS, Kubasiak J. Retrograde blood flow in the brachial and axillary arteries during routine radial arterial catheter flushing. Anesthesiology. 2006;105(3):492–7.CrossRefPubMed Murphy GS, Szokol JW, Marymont JH, Avram MJ, Vender JS, Kubasiak J. Retrograde blood flow in the brachial and axillary arteries during routine radial arterial catheter flushing. Anesthesiology. 2006;105(3):492–7.CrossRefPubMed
Metadaten
Titel
Can variable practice habits and injection port dead-volume put patients at risk?
verfasst von
Michael T. Kuntz
Roman Dudaryk
Richard R. McNeer
Publikationsdatum
10.07.2018
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2019
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-0179-3

Weitere Artikel der Ausgabe 4/2019

Journal of Clinical Monitoring and Computing 4/2019 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.