Capnodynamic assessment of effective lung volume during cardiac output manipulations in a porcine model

verfasst von: Caroline Hällsjö Sander, Per-Arne Lönnqvist, Magnus Hallbäck, Fernando Suarez Sipmann, Mats Wallin, Anders Oldner, Håkan Björne

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

A capnodynamic calculation of effective pulmonary blood flow includes a lung volume factor (ELV) that has to be estimated to solve the mathematical equation. In previous studies ELV correlated to reference methods for functional residual capacity (FRC). The aim was to evaluate the stability of ELV during significant manipulations of cardiac output (CO) and assess the agreement for absolute values and trending capacity during PEEP changes at different lung conditions. Ten pigs were included. Alterations of alveolar carbon dioxide were induced by cyclic reoccurring inspiratory holds. The Sulphur hexafluoride technique for FRC measurements was used as reference. Cardiac output was altered by preload reduction and inotropic stimulation at PEEP 5 and 12 cmH2O both in normal lung conditions and after repeated lung lavages. ELV at baseline PEEP 5 was [mean (SD)], 810 (163) mL and decreased to 400 (42) mL after lavage. ELV was not significantly affected by CO alterations within the same PEEP level. In relation to FRC the overall bias (limits of agreement) was −35 (−271 to 201) mL, and percentage error 36 %. A small difference between ELV and FRC was seen at PEEP 5 cmH2O before lavage and at PEEP 12 cmH2O after lavage. ELV trending capability between PEEP steps, showed a concordance rate of 100 %. ELV was closely related to FRC and remained stable during significant changes in CO. The trending capability was excellent both before and after surfactant depletion.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Force ADT, Ranieri VM, Rubenfeld GD, Thompson BT, Ferguson ND, Caldwell E, Fan E, Camporota L, Slutsky AS. Acute respiratory distress syndrome: the Berlin Definition. JAMA J Am Med Assoc. 2012;307(23):2526–33. doi:10.1001/jama.2012.5669. Force ADT, Ranieri VM, Rubenfeld GD, Thompson BT, Ferguson ND, Caldwell E, Fan E, Camporota L, Slutsky AS. Acute respiratory distress syndrome: the Berlin Definition. JAMA J Am Med Assoc. 2012;307(23):2526–33. doi:10.​1001/​jama.​2012.​5669.
3.
Zurück zum Zitat Albu G, Wallin M, Hallback M, Emtell P, Wolf A, Lonnqvist PA, Gothberg S, Petak F, Habre W. Comparison of static end-expiratory and effective lung volumes for gas exchange in healthy and surfactant-depleted lungs. Anesthesiology. 2013;119(1):101–10. doi:10.1097/ALN.0b013e3182923c40.CrossRefPubMed Albu G, Wallin M, Hallback M, Emtell P, Wolf A, Lonnqvist PA, Gothberg S, Petak F, Habre W. Comparison of static end-expiratory and effective lung volumes for gas exchange in healthy and surfactant-depleted lungs. Anesthesiology. 2013;119(1):101–10. doi:10.​1097/​ALN.​0b013e3182923c40​.CrossRefPubMed
5.
Zurück zum Zitat Brewer L, Orr J, Fulcher E, Markewitz B. Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation. J Clin Monit Comput. 2011;25(6):397–404. doi:10.1007/s10877-011-9318-9.CrossRefPubMed Brewer L, Orr J, Fulcher E, Markewitz B. Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation. J Clin Monit Comput. 2011;25(6):397–404. doi:10.​1007/​s10877-011-9318-9.CrossRefPubMed
6.
Zurück zum Zitat Hallsjo Sander C, Hallback M, Wallin M, Emtell P, Oldner A, Bjorne H. Novel continuous capnodynamic method for cardiac output assessment during mechanical ventilation. Br J Anaesth. 2014;112(5):824–31. doi:10.1093/bja/aet486.CrossRefPubMed Hallsjo Sander C, Hallback M, Wallin M, Emtell P, Oldner A, Bjorne H. Novel continuous capnodynamic method for cardiac output assessment during mechanical ventilation. Br J Anaesth. 2014;112(5):824–31. doi:10.​1093/​bja/​aet486.CrossRefPubMed
7.
Zurück zum Zitat Berggren S. The oxygeic deficit of arterial blood caused by non-ventilation parts of the lung. Acta Physiologica Scandinavica 1942;11:1–92. Berggren S. The oxygeic deficit of arterial blood caused by non-ventilation parts of the lung. Acta Physiologica Scandinavica 1942;11:1–92.
8.
Zurück zum Zitat Aksnes EG. Determinations of physiological dead-space and alveolo-arterial oxygen gradients by the indirect methods of Riley and Enghoff. III. Studies in patients with pulmonary tuberculosis. Scand J Clin Lab Invest. 1962;14:507–12.CrossRefPubMed Aksnes EG. Determinations of physiological dead-space and alveolo-arterial oxygen gradients by the indirect methods of Riley and Enghoff. III. Studies in patients with pulmonary tuberculosis. Scand J Clin Lab Invest. 1962;14:507–12.CrossRefPubMed
9.
Zurück zum Zitat Larsson A, Linnarsson D, Jonmarker C, Jonson B, Larsson H, Werner O. Measurement of lung volume by sulfur hexafluoride washout during spontaneous and controlled ventilation: further development of a method. Anesthesiology. 1987;67(4):543–50.CrossRefPubMed Larsson A, Linnarsson D, Jonmarker C, Jonson B, Larsson H, Werner O. Measurement of lung volume by sulfur hexafluoride washout during spontaneous and controlled ventilation: further development of a method. Anesthesiology. 1987;67(4):543–50.CrossRefPubMed
10.
Zurück zum Zitat Capek JM, Roy RJ. Noninvasive measurement of cardiac output using partial CO2 rebreathing. IEEE transactions on bio-medical engineering. 1988;35(9):653–61.CrossRefPubMed Capek JM, Roy RJ. Noninvasive measurement of cardiac output using partial CO2 rebreathing. IEEE transactions on bio-medical engineering. 1988;35(9):653–61.CrossRefPubMed
12.
Zurück zum Zitat Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies—with specific reference to the measurement of cardiac output. Crit Care. 2009;13(1):201. doi:10.1186/cc7129.CrossRefPubMedPubMedCentral Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies—with specific reference to the measurement of cardiac output. Crit Care. 2009;13(1):201. doi:10.​1186/​cc7129.CrossRefPubMedPubMedCentral
13.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRefPubMed Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRefPubMed
14.
Zurück zum Zitat Axiak Flammer SM, Critchley LA, Weber A, Pirbodaghi T, Brinks H, Vandenberghe S. Reliability of lithium dilution cardiac output in anaesthetized sheep. Br J Anaesth. 2013;111(5):833–9. doi:10.1093/bja/aet220.CrossRefPubMed Axiak Flammer SM, Critchley LA, Weber A, Pirbodaghi T, Brinks H, Vandenberghe S. Reliability of lithium dilution cardiac output in anaesthetized sheep. Br J Anaesth. 2013;111(5):833–9. doi:10.​1093/​bja/​aet220.CrossRefPubMed
16.
17.
Zurück zum Zitat Yem JS, Turner MJ, Baker AB. Sources of error in partial rebreathing pulmonary blood flow measurements in lungs with emphysema and pulmonary embolism. Br J Anaesth. 2006;97(5):732–41. doi:10.1093/bja/ael214.CrossRefPubMed Yem JS, Turner MJ, Baker AB. Sources of error in partial rebreathing pulmonary blood flow measurements in lungs with emphysema and pulmonary embolism. Br J Anaesth. 2006;97(5):732–41. doi:10.​1093/​bja/​ael214.CrossRefPubMed
18.
Zurück zum Zitat Yem JS, Tang Y, Turner MJ, Baker AB. Sources of error in noninvasive pulmonary blood flow measurements by partial rebreathing: a computer model study. Anesthesiology. 2003;98(4):881–7.CrossRefPubMed Yem JS, Tang Y, Turner MJ, Baker AB. Sources of error in noninvasive pulmonary blood flow measurements by partial rebreathing: a computer model study. Anesthesiology. 2003;98(4):881–7.CrossRefPubMed
Metadaten
Titel
Capnodynamic assessment of effective lung volume during cardiac output manipulations in a porcine model
verfasst von
Caroline Hällsjö Sander
Per-Arne Lönnqvist
Magnus Hallbäck
Fernando Suarez Sipmann
Mats Wallin
Anders Oldner
Håkan Björne
Publikationsdatum
16.09.2015
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 6/2016
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9767-7

Weitere Artikel der Ausgabe 6/2016

Journal of Clinical Monitoring and Computing 6/2016 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.