Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 3/2019

10.11.2018

Cardiac effects of CPAP treatment in patients with obstructive sleep apnea and atrial fibrillation

verfasst von: Asmaa M. Abumuamar, David Newman, Paul Dorian, Colin M. Shapiro

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 3/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Obstructive sleep apnea (OSA) has been recognized as an independent risk factor for the development and progression of atrial fibrillation (AF). We aimed to investigate the changes in heart rate and atrial and ventricular ectopy after continuous positive airway pressure (CPAP) treatment in patients with OSA and AF.

Methods

Consecutive patients with AF underwent ambulatory sleep monitoring, and OSA was defined as an Apnea-Hypopnea-Index (AHI) ≥ 5/h. Treated patients completed in-laboratory CPAP titration study. A 24-h ECG Holter was performed at baseline and at 3 and 6 months after CPAP treatment.

Results

One hundred patients (70% males) with AF were included in the final analysis. OSA was diagnosed in 85% of patients. There were no significant changes in mean 24-h heart rate in patients with paroxysmal or permanent AF at 3 and 6 months of treatment compared to baseline. In patients with paroxysmal AF (n = 29), atrial and ventricular ectopy counts/24 h significantly decreased at 3 months compared to baseline (median (IQR) 351 (2049) to 57 (182), P = 0.002; 68 (105) to 16 (133), P = 0.01 respectively). At 6 months follow-up, the atrial ectopy count/24 h significantly decreased in patients with paroxysmal AF compared to baseline (median (IQR) 351 (2049) to 31 (113), P = 0.016, n = 14). In patients with permanent AF (n = 15), there was a significant reduction in ventricular ectopy count/24 h at 3 months compared to baseline (median (IQR) 100 (1116) to 33 (418), P = 0.02).

Conclusions

There is a significant decrease in atrial and ventricular ectopy count/24 h in patients with AF and OSA at 3 and 6 months of CPAP treatment compared to baseline.
Literatur
2.
Zurück zum Zitat Mooe T, Gullsby S, Rabben T, Eriksson P. Sleep-disordered breathing: a novel predictor of atrial fibrillation after coronary artery bypass surgery. Coron Artery Dis. 1996;7(6):475–8.CrossRefPubMed Mooe T, Gullsby S, Rabben T, Eriksson P. Sleep-disordered breathing: a novel predictor of atrial fibrillation after coronary artery bypass surgery. Coron Artery Dis. 1996;7(6):475–8.CrossRefPubMed
3.
Zurück zum Zitat Abumuamar AM, Mollayeva T, Sandor P, Newman D, Nanthakumar K, Shapiro CM. Efficacy of continuous positive airway pressure treatment in patients with cardiac arrhythmia and obstructive sleep apnea: what is the evidence? Clinical Medicine Insights: Therapeutics. 2017;9(Supplementary Material_734227):1179559X17734227. https://doi.org/10.1177/1179559X17734227.CrossRef Abumuamar AM, Mollayeva T, Sandor P, Newman D, Nanthakumar K, Shapiro CM. Efficacy of continuous positive airway pressure treatment in patients with cardiac arrhythmia and obstructive sleep apnea: what is the evidence? Clinical Medicine Insights: Therapeutics. 2017;9(Supplementary Material_734227):1179559X17734227. https://​doi.​org/​10.​1177/​1179559X17734227​.CrossRef
11.
Zurück zum Zitat Mazza A, Bendini MG, Cristofori M, Nardi S, Leggio M, De Cristofaro R, et al. Baseline apnoea/hypopnoea index and high-sensitivity C-reactive protein for the risk of recurrence of atrial fibrillation after successful electrical cardioversion: a predictive model based upon the multiple effects of significant variables. Europace. 2009;11(7):902–9. https://doi.org/10.1093/europace/eup107.CrossRefPubMed Mazza A, Bendini MG, Cristofori M, Nardi S, Leggio M, De Cristofaro R, et al. Baseline apnoea/hypopnoea index and high-sensitivity C-reactive protein for the risk of recurrence of atrial fibrillation after successful electrical cardioversion: a predictive model based upon the multiple effects of significant variables. Europace. 2009;11(7):902–9. https://​doi.​org/​10.​1093/​europace/​eup107.CrossRefPubMed
12.
Zurück zum Zitat Narkiewicz K, Kato M, Phillips BG, Pesek CA, Davison DE, Somers VK. Nocturnal continuous positive airway pressure decreases daytime sympathetic traffic in obstructive sleep apnea. Circulation. 1999;100(23):2332–5.CrossRefPubMed Narkiewicz K, Kato M, Phillips BG, Pesek CA, Davison DE, Somers VK. Nocturnal continuous positive airway pressure decreases daytime sympathetic traffic in obstructive sleep apnea. Circulation. 1999;100(23):2332–5.CrossRefPubMed
15.
Zurück zum Zitat Bayir PT, Demirkan B, Bayir O, Duyuler S, Firat H, Güray U, et al. Impact of continuous positive airway pressure therapy on atrial electromechanical delay and P-wave dispersion in patients with obstructive sleep apnea. Ann Noninvasive Electrocardiol. 2014;19(3):226–33. https://doi.org/10.1111/anec.12106.CrossRefPubMed Bayir PT, Demirkan B, Bayir O, Duyuler S, Firat H, Güray U, et al. Impact of continuous positive airway pressure therapy on atrial electromechanical delay and P-wave dispersion in patients with obstructive sleep apnea. Ann Noninvasive Electrocardiol. 2014;19(3):226–33. https://​doi.​org/​10.​1111/​anec.​12106.CrossRefPubMed
19.
Zurück zum Zitat Holmqvist F, Guan N, Zhu Z, Kowey PR, Allen LA, Fonarow GC, et al. Impact of obstructive sleep apnea and continuous positive airway pressure therapy on outcomes in patients with atrial fibrillation—results from the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT-AF). Am Heart J. 2015;169(5):647–654.e2. https://doi.org/10.1016/j.ahj.2014.12.024.CrossRefPubMed Holmqvist F, Guan N, Zhu Z, Kowey PR, Allen LA, Fonarow GC, et al. Impact of obstructive sleep apnea and continuous positive airway pressure therapy on outcomes in patients with atrial fibrillation—results from the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation (ORBIT-AF). Am Heart J. 2015;169(5):647–654.e2. https://​doi.​org/​10.​1016/​j.​ahj.​2014.​12.​024.CrossRefPubMed
21.
Zurück zum Zitat Dediu GN, Dumitrache-Rujinski S, Lungu R, Frunză S, Diaconu C, Bartoş D, et al. Positive pressure therapy in patients with cardiac arrhythmias and obstructive sleep apnea. Pneumologia. 2015;64(1):18–22.PubMed Dediu GN, Dumitrache-Rujinski S, Lungu R, Frunză S, Diaconu C, Bartoş D, et al. Positive pressure therapy in patients with cardiac arrhythmias and obstructive sleep apnea. Pneumologia. 2015;64(1):18–22.PubMed
22.
Zurück zum Zitat Harbison J, O’Reilly P, McNicholas WT. Cardiac rhythm disturbances in the obstructive sleep apnea syndrome: effects of nasal continuous positive airway pressure therapy. Chest. 2000;118(3):591–5.CrossRefPubMed Harbison J, O’Reilly P, McNicholas WT. Cardiac rhythm disturbances in the obstructive sleep apnea syndrome: effects of nasal continuous positive airway pressure therapy. Chest. 2000;118(3):591–5.CrossRefPubMed
29.
Zurück zum Zitat Kwon Y, Koene RJ, Kwon O, Kealhofer JV, Adabag S, Duval S. Effect of sleep-disordered breathing on appropriate implantable cardioverter-defibrillator therapy in patients with heart failure: a systematic review and meta-analysis. Circ Arrhythm Electrophysiol. 2017;10(2):–e004609. https://doi.org/10.1161/CIRCEP.116.004609. Kwon Y, Koene RJ, Kwon O, Kealhofer JV, Adabag S, Duval S. Effect of sleep-disordered breathing on appropriate implantable cardioverter-defibrillator therapy in patients with heart failure: a systematic review and meta-analysis. Circ Arrhythm Electrophysiol. 2017;10(2):–e004609. https://​doi.​org/​10.​1161/​CIRCEP.​116.​004609.
Metadaten
Titel
Cardiac effects of CPAP treatment in patients with obstructive sleep apnea and atrial fibrillation
verfasst von
Asmaa M. Abumuamar
David Newman
Paul Dorian
Colin M. Shapiro
Publikationsdatum
10.11.2018
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 3/2019
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-018-0482-4

Weitere Artikel der Ausgabe 3/2019

Journal of Interventional Cardiac Electrophysiology 3/2019 Zur Ausgabe

Update Kardiologie