Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 2/2020

05.10.2019 | Original Paper

Challenges of recognizing bicuspid aortic valve in elderly patients undergoing TAVR

verfasst von: Won-Keun Kim, Christoph Liebetrau, Ulrich Fischer-Rasokat, Matthias Renker, Andreas Rolf, Mirko Doss, Helge Möllmann, Holger Nef, Thomas Walther, Christian W. Hamm

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 2/2020

Einloggen, um Zugang zu erhalten

Abstract

Recognition of bicuspid aortic valve (BAV) may be challenging in elderly patients with heavily calcified aortic valves undergoing transcatheter aortic valve replacement (TAVR). In this subset, the diagnostic value of pre-procedural echocardiography in clinical routine is unknown. From a total of 2583 patients undergoing TAVR in our center, we determined the rate of BAV detected by routine echocardiography as documented in the medical records. Pre-procedural multidetector computed tomography (MDCT) images were retrospectively analyzed for the presence of BAV and served as reference standard. Using MDCT criteria, BAV was found in 235 (9.1%) (age 80.1 years [interquartile range 76.4; 83.4], 44.3% female). Of these, only 27/235 (11.5%) had been identified as BAV according to echocardiography reports, whereas 6/2348 (0.3%) with TAV had been wrongly diagnosed as BAV (p < 0.001; sensitivity 11.5%, specificity 99.7%). Correct diagnosis of BAV by echocardiography was more likely when transesophageal echocardiography was available (odds ratio (OR) 5.12 [95% confidence interval (CI) 2.22; 11.80]; p < 0.001) and the reader was experienced (OR 5.28 [95% CI 1.55; 18.04]; p = 0.008). Furthermore, correct diagnosis of BAV was more likely in bicommissural-type BAV (OR 2.22 [95% CI 0.90; 5.48]; p = 0.08), whereas heavy aortic valve calcification lead to misdiagnosis (OR 0.39 [95% CI 0.14; 1.06]; p = 0.07). In elderly patients with severe aortic stenosis that are candidates for TAVR, the presence of BAV may be considerably underestimated when relying solely on routine echocardiography. This underlines the value of MDCT for the screening of BAV in this patient population.
Literatur
3.
Zurück zum Zitat Takeda H, Muro T, Saito T et al (2013) Diagnostic accuracy of transthoracic and transesophageal echocardiography for the diagnosis of bicuspid aortic valve: comparison with operative findings. Osaka City Med J 59(2):69–78PubMed Takeda H, Muro T, Saito T et al (2013) Diagnostic accuracy of transthoracic and transesophageal echocardiography for the diagnosis of bicuspid aortic valve: comparison with operative findings. Osaka City Med J 59(2):69–78PubMed
Metadaten
Titel
Challenges of recognizing bicuspid aortic valve in elderly patients undergoing TAVR
verfasst von
Won-Keun Kim
Christoph Liebetrau
Ulrich Fischer-Rasokat
Matthias Renker
Andreas Rolf
Mirko Doss
Helge Möllmann
Holger Nef
Thomas Walther
Christian W. Hamm
Publikationsdatum
05.10.2019
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 2/2020
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-019-01704-8

Weitere Artikel der Ausgabe 2/2020

The International Journal of Cardiovascular Imaging 2/2020 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.