Abstract

Background

Modularity in total hip arthroplasty has been used for decades with great success, but new findings regarding corrosion artifacts have caused a resurgence in tapered junction research. Mechanically assisted crevice corrosion (MACC) is thought to be the mechanism by which corrosive attack occurs. Myriad multi-factorial variables are known to influence the susceptibility of a modular taper junction to MACC. Some of these variables are design and manufacture related and others can be controlled by the surgeon.

Questions/Purposes

This study was performed to assess a 22-year retrieval database to determine if correlations exist between severity of corrosion artifacts and head size, time in vivo, head offset, or head material. Secondarily, the agreement of visual and semi-quantitative scoring methods was assessed using the retrieved components.

Methods

A total of 210 femoral head tapers were scored and heads receiving high scores were measured to quantify material loss due to MACC.

Results

Increased head size and increased time in vivo did not correlate to higher corrosion scores. Contrarily, there were differences in corrosion scores based on femoral head offset and material. Deviations away from a neutral offset (where neutral is defined as the alignment of femoral head center and stem taper gage point) resulted in higher scores. Cobalt-chromium-molybdenum heads were associated with higher corrosion scores and higher material loss as compared to oxidized zirconium heads.

Conclusion

Reducing the moment arm at the head-neck junction and choosing a more inert material appears to provide greater resistance to corrosion.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Bis zum 22.10. bestellen und 100 € sparen!

Weitere Produktempfehlungen anzeigen
Zusatzmaterial
ESM 1 (PDF 1224 kb)
11420_2016_9517_MOESM1_ESM.pdf
ESM 2 (PDF 1224 kb)
11420_2016_9517_MOESM2_ESM.pdf
ESM 3 (PDF 1224 kb)
11420_2016_9517_MOESM3_ESM.pdf
ESM 4 (PDF 1224 kb)
11420_2016_9517_MOESM4_ESM.pdf
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 1/2017

HSS Journal ® 1/2017 Zur Ausgabe
  1. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

  2. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

Neu im Fachgebiet Orthopädie und Unfallchirurgie

 

 

 
 

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Orthopädie und Unfallchirurgie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise