Skip to main content
Erschienen in: Japanese Journal of Ophthalmology 1/2020

01.11.2019 | Clinical Investigation

Choroidal thickness and intraocular pressure after 25-gauge and 23-gauge vitrectomy for idiopathic epiretinal membrane

verfasst von: Asuka Takeyama, Yutaka Imamura, Masaki Shibata, Yuko Komiya, Goji Tomita, Masahiro Ishida

Erschienen in: Japanese Journal of Ophthalmology | Ausgabe 1/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To determine the relationship between the subfoveal choroidal thickness (SCT) and intraocular pressure (IOP) following 25-gauge (25G) and 23-gauge (23G) vitrectomy for idiopathic epiretinal membrane (ERM).

Study design

Retrospective, consecutive, interventional case series.

Methods

Sixty-two patients undergoing 25G vitrectomy and 56 patients undergoing 23G vitrectomy for ERM participated. SCT was measured using enhanced depth imaging optical coherence tomography and IOP were measured both at baseline and postoperatively.

Results

In both groups, the IOPs on day one and one week after surgery were significantly lower than at baseline (P < 0.001 for both). The rates of changes of IOP were significantly greater in 23G compared to 25G on day one (P = 0.026). In 23G the SCTs on day one and one week after surgery were significantly thicker (P < 0.001) than baseline. The rates of changes in SCT between baseline and day one negatively correlated with those of IOP in 23G (r = −0.559, P < 0.001) but no correlation was observed with 25G (r = −0.129, P = 0.316).

Conclusion

Choroidal thickness increases soon after 23G vitrectomy for ERM which is probably due to the transient hypotony, however, early SCT change does not appear in 25G vitrectomy. Twenty-five-gauge vitrectomy may have an advantage in minimizing postoperative choroidal changes.
Literatur
1.
Zurück zum Zitat Thompson JT, Sjaarda RN, Glaser BM, Murphy RP. Increased intraocular pressure after macular hole surgery. Am J Ophthalmol. 1996;121:615–22.CrossRef Thompson JT, Sjaarda RN, Glaser BM, Murphy RP. Increased intraocular pressure after macular hole surgery. Am J Ophthalmol. 1996;121:615–22.CrossRef
2.
Zurück zum Zitat Chen PP, Thompson JT. Risk factors for elevated intraocular pressure after the use of intraocular gases in vitreoretinal surgery. Ophthalmic Surg Lasers. 1997;28:37–42.PubMed Chen PP, Thompson JT. Risk factors for elevated intraocular pressure after the use of intraocular gases in vitreoretinal surgery. Ophthalmic Surg Lasers. 1997;28:37–42.PubMed
3.
Zurück zum Zitat Lalezary M, Shah RJ, Reddy RK, Kammer JA, Kuchtey RW, Joos KM, et al. Prospective retinal and optic nerve vitrectomy evaluation (PROVE) study: Twelve-month findings. Ophthalmology. 2014;121:1983–9.CrossRef Lalezary M, Shah RJ, Reddy RK, Kammer JA, Kuchtey RW, Joos KM, et al. Prospective retinal and optic nerve vitrectomy evaluation (PROVE) study: Twelve-month findings. Ophthalmology. 2014;121:1983–9.CrossRef
4.
Zurück zum Zitat Wu L, Berrocal MH, Rodriguez FJ, Maja M, Morales-Canton V, Figueroa M, et al. Intraocular pressure elevation after uncomplicated pars plana vitrectomy: Results of the pan American collaborative retina study group. Retina. 2014;34:1985–9.CrossRef Wu L, Berrocal MH, Rodriguez FJ, Maja M, Morales-Canton V, Figueroa M, et al. Intraocular pressure elevation after uncomplicated pars plana vitrectomy: Results of the pan American collaborative retina study group. Retina. 2014;34:1985–9.CrossRef
5.
Zurück zum Zitat Gupta OP, Weichel ED, Regillo CD, Fineman MS, Kaiser RS, Ho AC, et al. Postoperative complications associated with 25-gauge pars plana vitrectomy. Ophthalmic Surg Lasers Imaging. 2007;38:270–5.CrossRef Gupta OP, Weichel ED, Regillo CD, Fineman MS, Kaiser RS, Ho AC, et al. Postoperative complications associated with 25-gauge pars plana vitrectomy. Ophthalmic Surg Lasers Imaging. 2007;38:270–5.CrossRef
6.
Zurück zum Zitat Woo SJ, Park KH, Hwang JM, Kim JH, Yu YS, Chung H. Risk factors associated with sclerotomy leakage and postoperative hypotony after 23-gauge transconjunctival sutureless vitrectomy. Retina. 2009;29:456–63.CrossRef Woo SJ, Park KH, Hwang JM, Kim JH, Yu YS, Chung H. Risk factors associated with sclerotomy leakage and postoperative hypotony after 23-gauge transconjunctival sutureless vitrectomy. Retina. 2009;29:456–63.CrossRef
7.
Zurück zum Zitat Haas A, Seidel G, Steinbrugger I, Maier R, Gasser-Steiner V, Wedrich A, et al. Twenty-three-gauge and 20-gauge vitrectomy in epiretinal membrane surgery. Retina. 2010;30:112–6.CrossRef Haas A, Seidel G, Steinbrugger I, Maier R, Gasser-Steiner V, Wedrich A, et al. Twenty-three-gauge and 20-gauge vitrectomy in epiretinal membrane surgery. Retina. 2010;30:112–6.CrossRef
8.
Zurück zum Zitat Ishida M, Wakakuri T, Imamura Y. Correlation between choroidal thickness and intraocular pressure after 23-gauge vitrectomy for idiopathic epiretinal membrane. Int J Ophthalmol. 2018;11:1774–8.PubMedPubMedCentral Ishida M, Wakakuri T, Imamura Y. Correlation between choroidal thickness and intraocular pressure after 23-gauge vitrectomy for idiopathic epiretinal membrane. Int J Ophthalmol. 2018;11:1774–8.PubMedPubMedCentral
9.
Zurück zum Zitat Ahn SJ, Woo SJ, Park KH. Choroidal thickness change following vitrectomy in idiopathic epiretinal membrane and macular hole. Graefes Arch Clin Exp Ophthalmol. 2016;254:1059–67.CrossRef Ahn SJ, Woo SJ, Park KH. Choroidal thickness change following vitrectomy in idiopathic epiretinal membrane and macular hole. Graefes Arch Clin Exp Ophthalmol. 2016;254:1059–67.CrossRef
10.
Zurück zum Zitat Kara N, Baz O, Altan C, Satana B, Kurt T, Demirok A. Changes in choroidal thickness, axial length, and ocular perfusion pressure accompanying successful glaucoma filtration surgery. Eye (Lond). 2013;27:940–5.CrossRef Kara N, Baz O, Altan C, Satana B, Kurt T, Demirok A. Changes in choroidal thickness, axial length, and ocular perfusion pressure accompanying successful glaucoma filtration surgery. Eye (Lond). 2013;27:940–5.CrossRef
11.
Zurück zum Zitat Chang S. LXII Edward Jackson lecture: Open angle glaucoma after vitrectomy. Am J Ophthalmol. 2006;141:1033–43.CrossRef Chang S. LXII Edward Jackson lecture: Open angle glaucoma after vitrectomy. Am J Ophthalmol. 2006;141:1033–43.CrossRef
12.
Zurück zum Zitat Brown JS, Flitcroft DI, Ying GS, Francis EL, Schmid GF, Quinn GE, et al. In vivo human choroidal thickness measurements: Evidence for diurnal fluctuations. Invest Ophthalmol Vis Sci. 2009;50:5–12.CrossRef Brown JS, Flitcroft DI, Ying GS, Francis EL, Schmid GF, Quinn GE, et al. In vivo human choroidal thickness measurements: Evidence for diurnal fluctuations. Invest Ophthalmol Vis Sci. 2009;50:5–12.CrossRef
13.
Zurück zum Zitat Chakraborty R, Read SA, Collins MJ. Diurnal variations in axial length, choroidal thickness, intraocular pressure, and ocular biometrics. Invest Ophthalmol Vis Sci. 2011;52:5121–9.CrossRef Chakraborty R, Read SA, Collins MJ. Diurnal variations in axial length, choroidal thickness, intraocular pressure, and ocular biometrics. Invest Ophthalmol Vis Sci. 2011;52:5121–9.CrossRef
14.
Zurück zum Zitat Tan CS, Ouyang Y, Ruiz H, Sadda SR. Diurnal variation of choroidal thickness in normal, healthy subjects measured by spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2012;53:261–6.CrossRef Tan CS, Ouyang Y, Ruiz H, Sadda SR. Diurnal variation of choroidal thickness in normal, healthy subjects measured by spectral domain optical coherence tomography. Invest Ophthalmol Vis Sci. 2012;53:261–6.CrossRef
15.
Zurück zum Zitat Usui S, Ikuno Y, Akiba M, Maruko I, Sekiryu T, Nishida K, et al. Circadian changes in subfoveal choroidal thickness and the relationship with circulatory factors in healthy subjects. Invest Ophthalmol Vis Sci. 2012;53:2300–7.CrossRef Usui S, Ikuno Y, Akiba M, Maruko I, Sekiryu T, Nishida K, et al. Circadian changes in subfoveal choroidal thickness and the relationship with circulatory factors in healthy subjects. Invest Ophthalmol Vis Sci. 2012;53:2300–7.CrossRef
16.
Zurück zum Zitat Kida T, Liu JH, Weinreb RN. Effect of 24-hour corneal biomechanical changes on intraocular pressure measurement. Invest Ophthalmol Vis Sci. 2006;47:4422–6.CrossRef Kida T, Liu JH, Weinreb RN. Effect of 24-hour corneal biomechanical changes on intraocular pressure measurement. Invest Ophthalmol Vis Sci. 2006;47:4422–6.CrossRef
Metadaten
Titel
Choroidal thickness and intraocular pressure after 25-gauge and 23-gauge vitrectomy for idiopathic epiretinal membrane
verfasst von
Asuka Takeyama
Yutaka Imamura
Masaki Shibata
Yuko Komiya
Goji Tomita
Masahiro Ishida
Publikationsdatum
01.11.2019
Verlag
Springer Japan
Erschienen in
Japanese Journal of Ophthalmology / Ausgabe 1/2020
Print ISSN: 0021-5155
Elektronische ISSN: 1613-2246
DOI
https://doi.org/10.1007/s10384-019-00694-3

Weitere Artikel der Ausgabe 1/2020

Japanese Journal of Ophthalmology 1/2020 Zur Ausgabe

Neu im Fachgebiet Augenheilkunde

Update Augenheilkunde

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.