Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 2/2017

14.12.2015 | Original Article

Clinic research on the treatment for humeral shaft fracture with minimal invasive plate osteosynthesis: a retrospective study of 128 cases

verfasst von: H. Chen, X. Hu, G. Yang, M. Xiang

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 2/2017

Einloggen, um Zugang zu erhalten

Abstract

Introduction

Minimal invasive plate osteosynthesis (MIPO) is one of the most important techniques in the treatment for humeral shaft fractures. This study was performed to evaluate the efficacy of MIPO technique for the treatment for humeral shaft fractures.

Materials and methods

We retrospectively evaluated 128 cases with humeral shaft fractures that were treated with MIPO technique from March 2005 to August 2008. All the patients were followed up by routine radiological imaging and clinical examinations. Constant–Murley score and HSS elbow joint score were used to evaluate the treatment outcome.

Results

The average duration of the surgery was 60 min (range 40–95 min) without blood transfusion. All fractures healed without infection. All cases recovered carrying angle except four cases with 10°–15° cubitus varus. After the average follow-up of 23 (13–38) months, satisfactory function was achieved according to Constant–Murley score and HSS elbow joint score. Constant–Murley score was 80 on average (range 68–91). According to HSS elbow joint score, there were 123 cases of excellent clinical outcome and five cases of effective outcome.

Conclusion

It seems to be a safe and effective method for managing humeral shaft fractures with MIPO technique.
Literatur
1.
Zurück zum Zitat Helmy N, Hintermann B. New trends in the treatment of proximal humerus fractures. Clin Orthop Relat Res. 2006;442:100–8.CrossRefPubMed Helmy N, Hintermann B. New trends in the treatment of proximal humerus fractures. Clin Orthop Relat Res. 2006;442:100–8.CrossRefPubMed
2.
Zurück zum Zitat Shao Y, Harwood P, Grotz M, Giannoudis P. Radial nerve palsy associated with fractures of the shaft of the humerus: a systematic review. J Bone Joint Surg Br Vol. 2005;87(12):1647–52.CrossRef Shao Y, Harwood P, Grotz M, Giannoudis P. Radial nerve palsy associated with fractures of the shaft of the humerus: a systematic review. J Bone Joint Surg Br Vol. 2005;87(12):1647–52.CrossRef
3.
Zurück zum Zitat Livani B, Belangero WD. Bridging plate osteosynthesis of humeral shaft fractures. Injury. 2004;35(6):587–95.CrossRefPubMed Livani B, Belangero WD. Bridging plate osteosynthesis of humeral shaft fractures. Injury. 2004;35(6):587–95.CrossRefPubMed
4.
Zurück zum Zitat Livani B, Belangero W, Andrade K, Zuiani G, Pratali R. Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation. Int Orthop. 2009;33(6):1719–23.CrossRefPubMed Livani B, Belangero W, Andrade K, Zuiani G, Pratali R. Is MIPO in humeral shaft fractures really safe? Postoperative ultrasonographic evaluation. Int Orthop. 2009;33(6):1719–23.CrossRefPubMed
5.
Zurück zum Zitat Bono CM, Grossman MG, Hochwald N, Tornetta P III. Radial and axillary nerves: anatomic considerations for humeral fixation. Clin Orthop Relat Res. 2000;373:259–64.CrossRef Bono CM, Grossman MG, Hochwald N, Tornetta P III. Radial and axillary nerves: anatomic considerations for humeral fixation. Clin Orthop Relat Res. 2000;373:259–64.CrossRef
6.
Zurück zum Zitat Crenshaw A. Surgical approaches. In: Campell’s operative orthopaedics, vol 1, 8th edn. St Louis: Mosby, 1992:23–116. Crenshaw A. Surgical approaches. In: Campell’s operative orthopaedics, vol 1, 8th edn. St Louis: Mosby, 1992:23–116.
7.
Zurück zum Zitat Smith J, Berry G, Laflamme Y, Blain-Pare E, Reindl R, Harvey E. Percutaneous insertion of a proximal humeral locking plate: an anatomic study. Injury. 2007;38(2):206–11.CrossRefPubMed Smith J, Berry G, Laflamme Y, Blain-Pare E, Reindl R, Harvey E. Percutaneous insertion of a proximal humeral locking plate: an anatomic study. Injury. 2007;38(2):206–11.CrossRefPubMed
8.
Zurück zum Zitat Claessen FM, Peters RM, Verbeek DO, Helfet DL, Ring D. Factors associated with radial nerve palsy after operative treatment of diaphyseal humeral shaft fractures. J Shoulder Elbow Surg. 2015;24(11):e307–11.CrossRefPubMed Claessen FM, Peters RM, Verbeek DO, Helfet DL, Ring D. Factors associated with radial nerve palsy after operative treatment of diaphyseal humeral shaft fractures. J Shoulder Elbow Surg. 2015;24(11):e307–11.CrossRefPubMed
10.
Zurück zum Zitat Lau T, Leung F, Chan C, Chow S. Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture. Int Orthop. 2007;31(5):657–64.CrossRefPubMed Lau T, Leung F, Chan C, Chow S. Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture. Int Orthop. 2007;31(5):657–64.CrossRefPubMed
11.
Zurück zum Zitat Standring S, Ellis H, Healy J, Johnson D, Williams A, Collins P, et al. Gray’s anatomy: the anatomical basis of clinical practice. Am J Neuroradiol. 2005;26(10):2703. Standring S, Ellis H, Healy J, Johnson D, Williams A, Collins P, et al. Gray’s anatomy: the anatomical basis of clinical practice. Am J Neuroradiol. 2005;26(10):2703.
12.
Zurück zum Zitat Rancan M, Dietrich M, Lamdark T, Can U, Platz A. Minimal invasive long PHILOS®-plate osteosynthesis in metadiaphyseal fractures of the proximal humerus. Injury. 2010;41(12):1277–83.CrossRefPubMed Rancan M, Dietrich M, Lamdark T, Can U, Platz A. Minimal invasive long PHILOS®-plate osteosynthesis in metadiaphyseal fractures of the proximal humerus. Injury. 2010;41(12):1277–83.CrossRefPubMed
13.
Zurück zum Zitat Huerta LJ, Luna PD. A comparision of the prevalence of radial nerve lesion after fixation of humeral shaft fractures with dynamic compression plate versus intramedullary nailing. Acta Ort Mex. 2007;22(5):287–91. Huerta LJ, Luna PD. A comparision of the prevalence of radial nerve lesion after fixation of humeral shaft fractures with dynamic compression plate versus intramedullary nailing. Acta Ort Mex. 2007;22(5):287–91.
14.
Zurück zum Zitat Petsatodes G, Karataglis D, Papadopoulos P, Christoforides J, Gigis J, Pournaras J. Antegrade interlocking nailing of humeral shaft fractures. J Orthop Sci. 2004;9(3):247–52.CrossRefPubMed Petsatodes G, Karataglis D, Papadopoulos P, Christoforides J, Gigis J, Pournaras J. Antegrade interlocking nailing of humeral shaft fractures. J Orthop Sci. 2004;9(3):247–52.CrossRefPubMed
15.
Zurück zum Zitat Perren SM. Evolution of the internal fixation of long bone fractures. J Bone Joint Surg Br. 2002;84(8):1093–110.CrossRefPubMed Perren SM. Evolution of the internal fixation of long bone fractures. J Bone Joint Surg Br. 2002;84(8):1093–110.CrossRefPubMed
16.
Zurück zum Zitat Apivatthakakul T, Phornphutkul C, Laohapoonrungsee A, Sirirungruangsarn Y. Less invasive plate osteosynthesis in humeral shaft fractures. Oper Orthop Traumatol. 2009;21(6):602–13.CrossRefPubMed Apivatthakakul T, Phornphutkul C, Laohapoonrungsee A, Sirirungruangsarn Y. Less invasive plate osteosynthesis in humeral shaft fractures. Oper Orthop Traumatol. 2009;21(6):602–13.CrossRefPubMed
17.
Zurück zum Zitat Schwarz N, Windisch M, Mayr B. Minimally invasive anterior plate osteosynthesis in humeral shaft fractures. Eur J Trauma Emerg Surg. 2008;35(3):271–6.CrossRefPubMed Schwarz N, Windisch M, Mayr B. Minimally invasive anterior plate osteosynthesis in humeral shaft fractures. Eur J Trauma Emerg Surg. 2008;35(3):271–6.CrossRefPubMed
18.
Zurück zum Zitat Kim JW, Oh C-W, Byun Y-S, Kim JJ, Park KC. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis. J Orthop Trauma. 2015;29(4):189–94.CrossRefPubMed Kim JW, Oh C-W, Byun Y-S, Kim JJ, Park KC. A prospective randomized study of operative treatment for noncomminuted humeral shaft fractures: conventional open plating versus minimal invasive plate osteosynthesis. J Orthop Trauma. 2015;29(4):189–94.CrossRefPubMed
19.
Zurück zum Zitat Schwarz N, Windisch M, Mayr B. Minimally invasive anterior plate osteosynthesis in humeral shaft fractures. Eur J Trauma Emerg Surg. 2009;35(3):271–6.CrossRefPubMed Schwarz N, Windisch M, Mayr B. Minimally invasive anterior plate osteosynthesis in humeral shaft fractures. Eur J Trauma Emerg Surg. 2009;35(3):271–6.CrossRefPubMed
Metadaten
Titel
Clinic research on the treatment for humeral shaft fracture with minimal invasive plate osteosynthesis: a retrospective study of 128 cases
verfasst von
H. Chen
X. Hu
G. Yang
M. Xiang
Publikationsdatum
14.12.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 2/2017
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-015-0616-7

Weitere Artikel der Ausgabe 2/2017

European Journal of Trauma and Emergency Surgery 2/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.