Skip to main content
Erschienen in: International Orthopaedics 6/2016

18.04.2016 | Original Paper

Clinical and radiographic outcome of unilateral open-door laminoplasty with alternative levels centerpiece mini-plate fixation for cervical compressive myelopathy: a five-year follow-up study

verfasst von: Lin-nan Wang, Lei Wang, Yue-ming Song, Xi Yang, Li-min Liu, Tao Li

Erschienen in: International Orthopaedics | Ausgabe 6/2016

Einloggen, um Zugang zu erhalten

Abstract

Introduction

To evaluate the five year clinical and radiographic outcome of unilateral open-door laminoplasty with alternative levels centerpiece mini-plate fixation for cervical compressive myelopathy.

Methods

From August 2009 to June 2010, 56 patients with cervical compressive myelopathy underwent unilateral open-door laminoplasty with alternative levels centerpiece mini-plate fixation with a mean age of 64.8 years. Clinical results were investigated including Japanese Orthopedic Association (JOA) scores, Neck Dysfunction Index (NDI), occurrences of complications and neurological deterioration. Radiographic results including cervical alignments, cervical range of motion (ROM), spinal canal enlargement and spinal cord decompression were assessed on X-ray, three-dimensional CT and MRI.

Results

The mean follow-up period was 59.2 months (range 53∼64 months), and all patients achieved osseous fusion at hinge side at an average of 6.8 months after operation. The average cost from admission to discharge is $9817.9. Compared to previous all-level fixation, the cost decreased nearly 40 %. During the follow-up, all patients showed a significant improvement in the JOA score and NDI score. A 23.2 % incidence of axial neck pain were also observed; Significant enlargement of the spinal canal and spinal cord drift was achieved and well maintained, overall cervical ROM decreased by 27.1 % (mean 12.9° loss) at the final follow-up and cervical lordosis decreased slightly in all patients without statistic difference. No instrumentation failure or lamina reclosure was observed in our study. Comparing mini-plate segments and suture segments, the mean AP diameter and Pavlov’s ratio at the final follow-up showed no statistic difference, only open angle at the final follow-up showed significant decrease.

Conclusions

Unilateral open-door laminoplasty with alternative levels centerpiece mini-plate fixation is a safe, effective and economical surgical method for cervical compressive myelopathy and the five year result is satisfactory.
Literatur
1.
Zurück zum Zitat Jiang JL, Li XL, Zhou XG, Lin H, Dong J (2012) Plate-only open-door laminoplasty with fusion for treatment of multilevel degenerative cervical disease. J Clin Neurosci 19(6):804–809CrossRefPubMed Jiang JL, Li XL, Zhou XG, Lin H, Dong J (2012) Plate-only open-door laminoplasty with fusion for treatment of multilevel degenerative cervical disease. J Clin Neurosci 19(6):804–809CrossRefPubMed
2.
Zurück zum Zitat Suri A, Chabbra RP, Mehta VS, Gaikwad S, Pandey RM (2003) Effect of intramedullary signal changes on the surgical outcome of patients with cervical spondylotic myelopathy. Spine J 3(1):33–45CrossRefPubMed Suri A, Chabbra RP, Mehta VS, Gaikwad S, Pandey RM (2003) Effect of intramedullary signal changes on the surgical outcome of patients with cervical spondylotic myelopathy. Spine J 3(1):33–45CrossRefPubMed
3.
Zurück zum Zitat Chiba K, Ogawa Y, Ishii K et al (2006) Long-term results of expansive open-door laminoplasty for cervical myelopathy-average 14-year follow-up study. Spine 31(26):2998–3005CrossRefPubMed Chiba K, Ogawa Y, Ishii K et al (2006) Long-term results of expansive open-door laminoplasty for cervical myelopathy-average 14-year follow-up study. Spine 31(26):2998–3005CrossRefPubMed
4.
Zurück zum Zitat Hirabayashi K, Watanabe K, Wakano K, Suzuki N, Satomi K, Ishii Y (1983) Expansive open-door laminoplasty for cervical spinal stenotic myelopathy. Spine 8(7):693–699CrossRefPubMed Hirabayashi K, Watanabe K, Wakano K, Suzuki N, Satomi K, Ishii Y (1983) Expansive open-door laminoplasty for cervical spinal stenotic myelopathy. Spine 8(7):693–699CrossRefPubMed
5.
Zurück zum Zitat Hyun SJ, Rhim SC, Roh SW, Kang SH, Riew KD (2009) The time course of range of motion loss after cervical laminoplasty: a prospective study with minimum two-year follow-up. Spine 34(11):1134–1139CrossRefPubMed Hyun SJ, Rhim SC, Roh SW, Kang SH, Riew KD (2009) The time course of range of motion loss after cervical laminoplasty: a prospective study with minimum two-year follow-up. Spine 34(11):1134–1139CrossRefPubMed
6.
Zurück zum Zitat Tanaka N, Nakanishi K, Fujimoto Y et al (2008) Expansive laminoplasty for cervical myelopathy with interconnected porous calcium hydroxyapatite ceramic spacers: comparison with autogenous bone spacers. J Spinal Disord Tech 21(8):547–552CrossRefPubMed Tanaka N, Nakanishi K, Fujimoto Y et al (2008) Expansive laminoplasty for cervical myelopathy with interconnected porous calcium hydroxyapatite ceramic spacers: comparison with autogenous bone spacers. J Spinal Disord Tech 21(8):547–552CrossRefPubMed
7.
Zurück zum Zitat Yu HL, Xiang LB, Liu J, Chen Y, Yu M, Cao Y (2010) Laminoplasty using Twinfix suture anchors to maintain cervical canal expansion. Eur Spine J 19(10):1795–1798CrossRefPubMedPubMedCentral Yu HL, Xiang LB, Liu J, Chen Y, Yu M, Cao Y (2010) Laminoplasty using Twinfix suture anchors to maintain cervical canal expansion. Eur Spine J 19(10):1795–1798CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Ono A, Yokoyama T, Numasawa T, Wada K, Toh S (2007) Dural damage due to a loosened hydroxyapatite intraspinous spacer after spinous process-splitting laminoplasty. Report of two cases. J Neurosurg Spine 7(2):230–235CrossRefPubMed Ono A, Yokoyama T, Numasawa T, Wada K, Toh S (2007) Dural damage due to a loosened hydroxyapatite intraspinous spacer after spinous process-splitting laminoplasty. Report of two cases. J Neurosurg Spine 7(2):230–235CrossRefPubMed
9.
Zurück zum Zitat Kanemura A, Doita M, Iguchi T, Kasahara K, Kurosaka M, Sumi M (2008) Delayed dural laceration by hydroxyapatite spacer causing tetraparesis following double-door laminoplasty. J Neurosurg Spine 8(2):121–128CrossRefPubMed Kanemura A, Doita M, Iguchi T, Kasahara K, Kurosaka M, Sumi M (2008) Delayed dural laceration by hydroxyapatite spacer causing tetraparesis following double-door laminoplasty. J Neurosurg Spine 8(2):121–128CrossRefPubMed
10.
Zurück zum Zitat Rhee JM, Register B, Hamasaki T, Franklin B (2010) Plate-only open door laminoplasty maintains stable spinal canal expansion with high rates of hinge union and no plate failures. Spine 36(1):9–14CrossRef Rhee JM, Register B, Hamasaki T, Franklin B (2010) Plate-only open door laminoplasty maintains stable spinal canal expansion with high rates of hinge union and no plate failures. Spine 36(1):9–14CrossRef
11.
Zurück zum Zitat Jiang LJ, Chen WS, Chen Q, Xu K, Wu Q, Li F (2012) Clinical application of a new plate fixation system in open-door laminoplasty. Orthopedics 35(2):225–231 Jiang LJ, Chen WS, Chen Q, Xu K, Wu Q, Li F (2012) Clinical application of a new plate fixation system in open-door laminoplasty. Orthopedics 35(2):225–231
12.
Zurück zum Zitat Matsuzaki H, Hoshino M, Kiuchi T, Toriyama S (1989) Expansive laminoplasty for the second cervical vertebra. Spine 14(11):1198–1203CrossRefPubMed Matsuzaki H, Hoshino M, Kiuchi T, Toriyama S (1989) Expansive laminoplasty for the second cervical vertebra. Spine 14(11):1198–1203CrossRefPubMed
13.
Zurück zum Zitat Takeshita K, Murakami M, Kobayashi A, Nakamura C (2001) Relationship between cervical curvature index (Ishihara) and cervical spine angle (C2—7). J Orthop Sci 6(3):223–226CrossRefPubMed Takeshita K, Murakami M, Kobayashi A, Nakamura C (2001) Relationship between cervical curvature index (Ishihara) and cervical spine angle (C2—7). J Orthop Sci 6(3):223–226CrossRefPubMed
14.
Zurück zum Zitat Iwasaki M, Kawaguchi Y, Kimura T, Yonenobu K (2002) Long-term results of expansive laminoplasty for ossification of the posterior longitudinal ligament of the cervical spine: more than 10 years follow up. J Neurosurg 96(2 Suppl):180–189 Iwasaki M, Kawaguchi Y, Kimura T, Yonenobu K (2002) Long-term results of expansive laminoplasty for ossification of the posterior longitudinal ligament of the cervical spine: more than 10 years follow up. J Neurosurg 96(2 Suppl):180–189
15.
Zurück zum Zitat Kawaguchi Y, Kanamori M, Ishihara H et al (2003) Minimum 10-year follow-up after an bloc cervical laminoplasty. Clin Orthop 411:129–139CrossRefPubMed Kawaguchi Y, Kanamori M, Ishihara H et al (2003) Minimum 10-year follow-up after an bloc cervical laminoplasty. Clin Orthop 411:129–139CrossRefPubMed
16.
Zurück zum Zitat Wang HQ, Mak KC, Samartzis D et al (2011) “Spring-back” closure associated with open-door cervical laminoplasty. Spine J 11(9):832–838CrossRefPubMed Wang HQ, Mak KC, Samartzis D et al (2011) “Spring-back” closure associated with open-door cervical laminoplasty. Spine J 11(9):832–838CrossRefPubMed
17.
Zurück zum Zitat Lee DH, Park SA, Kim NH et al (2011) Laminar closure after classic Hirabayashi open-door Laminoplasty. Spine 36(25):1634–1640CrossRef Lee DH, Park SA, Kim NH et al (2011) Laminar closure after classic Hirabayashi open-door Laminoplasty. Spine 36(25):1634–1640CrossRef
18.
Zurück zum Zitat Seichi A, Hoshino Y, Kimura A et al (2011) Neurological complications of cervical laminoplasty for patients with ossification of the posterior longitudinal ligament-a multi-institutional retrospective study. Spine 36(15):998–1003CrossRef Seichi A, Hoshino Y, Kimura A et al (2011) Neurological complications of cervical laminoplasty for patients with ossification of the posterior longitudinal ligament-a multi-institutional retrospective study. Spine 36(15):998–1003CrossRef
19.
Zurück zum Zitat Satomi K, Nishu Y, Kohno T, Hirabayashi K (1994) Long-term follow-up studies of open-door expansive laminoplasty for cervical stenotic myelopathy. Spine 19(5):507–510CrossRefPubMed Satomi K, Nishu Y, Kohno T, Hirabayashi K (1994) Long-term follow-up studies of open-door expansive laminoplasty for cervical stenotic myelopathy. Spine 19(5):507–510CrossRefPubMed
20.
Zurück zum Zitat Cheng Z, Chen W, Yan S, Li W, Qian S (2015) Expansive open-door cervical laminoplasty: in situ reconstruction of extensor muscle insertion on the C2 spinous process combined with titanium miniplates internal fixation. Medicine 94(28):1–6 Cheng Z, Chen W, Yan S, Li W, Qian S (2015) Expansive open-door cervical laminoplasty: in situ reconstruction of extensor muscle insertion on the C2 spinous process combined with titanium miniplates internal fixation. Medicine 94(28):1–6
21.
Zurück zum Zitat Hosono N, Yonenobu K, Ono K (1996) Neck and shoulder pain after laminoplasty. A noticeable complication. Spine 21(17):1969–1973CrossRefPubMed Hosono N, Yonenobu K, Ono K (1996) Neck and shoulder pain after laminoplasty. A noticeable complication. Spine 21(17):1969–1973CrossRefPubMed
22.
Zurück zum Zitat Wang ZF, Chen GD, Xue F, Sheng XW, Yang HL, Qian J (2014) All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty. Indian J Orthop 48(6):582–586CrossRefPubMedPubMedCentral Wang ZF, Chen GD, Xue F, Sheng XW, Yang HL, Qian J (2014) All levels versus alternate levels plate fixation in expansive open door cervical laminoplasty. Indian J Orthop 48(6):582–586CrossRefPubMedPubMedCentral
Metadaten
Titel
Clinical and radiographic outcome of unilateral open-door laminoplasty with alternative levels centerpiece mini-plate fixation for cervical compressive myelopathy: a five-year follow-up study
verfasst von
Lin-nan Wang
Lei Wang
Yue-ming Song
Xi Yang
Li-min Liu
Tao Li
Publikationsdatum
18.04.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 6/2016
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-016-3194-3

Weitere Artikel der Ausgabe 6/2016

International Orthopaedics 6/2016 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.