Skip to main content
Erschienen in: International Urogynecology Journal 12/2012

01.12.2012 | Original Article

Clinical evaluation of a wireless intra-vaginal pressure transducer

verfasst von: Yvonne Hsu, Tanner J. Coleman, Robert W. Hitchcock, Kristina Heintz, Janet M. Shaw, Ingrid E. Nygaard

Erschienen in: International Urogynecology Journal | Ausgabe 12/2012

Einloggen, um Zugang zu erhalten

Abstract

Objective

To describe the development, feasibility and validity of a wireless intra-vaginal pressure transducer (IVT) which can be used to measure intra-abdominal pressure in real-world settings.

Study design

A feasibility study was conducted in sixteen physically active women to determine retention and comfort of various IVT prototype designs during activity. A criterion validity study was conducted among women undergoing urodynamic testing to determine the accuracy of the IVT prototypes when compared to accepted clinical standards.

Results

A final prototype wireless IVT was developed after four design revisions of the second generation model. The feasibility study found that women reported the final prototype comfortable to wear and easily retained during physical activity. Intra-abdominal pressure measurements from the final prototype IVT compared favorably to standard urodynamic transducers, thus confirming evidence of its utility.

Conclusion

We have successfully advanced the design of a wireless, intra-vaginal pressure transducer which provides accurate measures of intra-abdominal pressure. The final wireless IVT is better tolerated by patients and overcomes limitations of traditional urodynamic testing while laying the foundations for intra-abdominal pressure monitoring outside of the clinic environment.
Literatur
1.
Zurück zum Zitat Woodman PJ, Swift SE, O’Boyle AL, Valley MT, Bland DR, Kahn MA, Schaffer JI (2006) Prevalence of severe pelvic organ prolapse in relation to job description and socioeconomic status: a multicenter cross-sectional study. Int Urogynecol J 17:340–5CrossRef Woodman PJ, Swift SE, O’Boyle AL, Valley MT, Bland DR, Kahn MA, Schaffer JI (2006) Prevalence of severe pelvic organ prolapse in relation to job description and socioeconomic status: a multicenter cross-sectional study. Int Urogynecol J 17:340–5CrossRef
2.
Zurück zum Zitat Braekken IH, Majida M, Ellstrom EM, Holme IM, Bo K (2009) Pelvic floor function is independently associated with pelvic organ prolapse. BJOG 116:1706–14PubMedCrossRef Braekken IH, Majida M, Ellstrom EM, Holme IM, Bo K (2009) Pelvic floor function is independently associated with pelvic organ prolapse. BJOG 116:1706–14PubMedCrossRef
3.
Zurück zum Zitat Nygaard I, Handa VL, Brubaker L, Borello-France D, Wei J, Wells E, Goode P, Pelvic Disorders Network (2008) Changes in physical activity after abdominal sacrocolpopexy for advanced pelvic organ prolapse. Am J Obstet Gynecol 198:570e1–5CrossRef Nygaard I, Handa VL, Brubaker L, Borello-France D, Wei J, Wells E, Goode P, Pelvic Disorders Network (2008) Changes in physical activity after abdominal sacrocolpopexy for advanced pelvic organ prolapse. Am J Obstet Gynecol 198:570e1–5CrossRef
4.
Zurück zum Zitat Rosenbluth EM, Johnson PJ, Hitchcock RW, Nygaard IE (2010) Developemnt and testing of a vaginal pressure sensor to measure intra-abdominal pressure in women. Neurourol Urodyn 29:532–5PubMed Rosenbluth EM, Johnson PJ, Hitchcock RW, Nygaard IE (2010) Developemnt and testing of a vaginal pressure sensor to measure intra-abdominal pressure in women. Neurourol Urodyn 29:532–5PubMed
5.
Zurück zum Zitat Johnson PJ, Rosenbluth EM, Nygaard IE, Parikh MK, Hitchcock RW (2009) Developemnt of a novel intra-vaginal transducer with improved dynamic response. Biomed Microdevices 11:1213–21PubMedCrossRef Johnson PJ, Rosenbluth EM, Nygaard IE, Parikh MK, Hitchcock RW (2009) Developemnt of a novel intra-vaginal transducer with improved dynamic response. Biomed Microdevices 11:1213–21PubMedCrossRef
6.
Zurück zum Zitat Coleman TJ, Thomsen JC, Maass SD, Hsu Y, Nygaard IE, Hitchcock RW (2011) Development of a wireless intra-vaginal transducer for monitoring intra-abdominal pressure in women. Biomed Microdevices. . [Epub ahead of print] Coleman TJ, Thomsen JC, Maass SD, Hsu Y, Nygaard IE, Hitchcock RW (2011) Development of a wireless intra-vaginal transducer for monitoring intra-abdominal pressure in women. Biomed Microdevices. . [Epub ahead of print]
7.
Zurück zum Zitat Malbrain ML (2004) Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal. Intensice Care Med 30:357–71CrossRef Malbrain ML (2004) Different techniques to measure intra-abdominal pressure (IAP): time for a critical re-appraisal. Intensice Care Med 30:357–71CrossRef
8.
Zurück zum Zitat Nager CW, Albo ME, Fitzgerald MP, McDermott SM, Kraus S, Richter HE, Zimmern P, Network Urinary Incontinence Treatment (2007) Process for development of multicenter urodynamic studies. Urology 69:63–7PubMedCrossRef Nager CW, Albo ME, Fitzgerald MP, McDermott SM, Kraus S, Richter HE, Zimmern P, Network Urinary Incontinence Treatment (2007) Process for development of multicenter urodynamic studies. Urology 69:63–7PubMedCrossRef
9.
Zurück zum Zitat ANSI/AAMI BP22: 1994 Association for the Advancement of Medical Instrumentation. ANSI/AAMI BP22: 1994 Association for the Advancement of Medical Instrumentation.
10.
Zurück zum Zitat Barber MD, Kuchibhatla MN, Pieper CF, Bump RC (2001) Psychometric evaluation of 2 comprehensive condition-specific quality of life instruments for women with pelvic floor disorders. Am J Obstet Gynecol 185:1388–95PubMedCrossRef Barber MD, Kuchibhatla MN, Pieper CF, Bump RC (2001) Psychometric evaluation of 2 comprehensive condition-specific quality of life instruments for women with pelvic floor disorders. Am J Obstet Gynecol 185:1388–95PubMedCrossRef
11.
Zurück zum Zitat Bump RC, Mattiasson A, Bø K, Brubaker LP, DeLancey JO, Klarskov P, Shull BL, Smith AR (1996) The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction. Am J Obstet Gynecol 175:10–7PubMedCrossRef Bump RC, Mattiasson A, Bø K, Brubaker LP, DeLancey JO, Klarskov P, Shull BL, Smith AR (1996) The standardization of terminology of female pelvic organ prolapse and pelvic floor dysfunction. Am J Obstet Gynecol 175:10–7PubMedCrossRef
12.
Zurück zum Zitat Lukban JC, Aguirre OA, Davila GW, Sand PK (2006) Safety and effectiveness of Colpexin sphere in the treatment of pelvic organ prolapse. Int Urogynecol J 17:449–54CrossRef Lukban JC, Aguirre OA, Davila GW, Sand PK (2006) Safety and effectiveness of Colpexin sphere in the treatment of pelvic organ prolapse. Int Urogynecol J 17:449–54CrossRef
13.
Zurück zum Zitat Gerten KA, Richter HE, Wheeler TL, Pair LS, Burgio KL, Redden DT, Varner RE, Hibner M (2008) Intrabdominal pressure changes associated with lifting:implications for postoperative activity restrictions. Am J Obstet Gyneol 198:306 Gerten KA, Richter HE, Wheeler TL, Pair LS, Burgio KL, Redden DT, Varner RE, Hibner M (2008) Intrabdominal pressure changes associated with lifting:implications for postoperative activity restrictions. Am J Obstet Gyneol 198:306
14.
Zurück zum Zitat Guttormson R, Tschirhart J, Boysen D, Martison K (2008) Are postoperative activity restrictions evidence-based? Am J Surg 195:401–3PubMedCrossRef Guttormson R, Tschirhart J, Boysen D, Martison K (2008) Are postoperative activity restrictions evidence-based? Am J Surg 195:401–3PubMedCrossRef
15.
Zurück zum Zitat Mouritsen L, Hulbaek M, Brostrom S, Bogstad J (2007) Vaginal pressure during activities before and after vaginal repair. Int Urogynecol J 18:943–8CrossRef Mouritsen L, Hulbaek M, Brostrom S, Bogstad J (2007) Vaginal pressure during activities before and after vaginal repair. Int Urogynecol J 18:943–8CrossRef
16.
Zurück zum Zitat Schäfer W, Abrams P, Liao L, Mattiasson A, Pesce F, Spangberg A, Sterling AM, Zinner NR, van Kerrebroeck P; International Continence Society. Good urodynamic practices:uroflowmetry, filling cystometry, and pressure-flow studies. Neuourol Urodyn 21:261–74 Schäfer W, Abrams P, Liao L, Mattiasson A, Pesce F, Spangberg A, Sterling AM, Zinner NR, van Kerrebroeck P; International Continence Society. Good urodynamic practices:uroflowmetry, filling cystometry, and pressure-flow studies. Neuourol Urodyn 21:261–74
17.
Zurück zum Zitat Iberti TJ, Lieber CE, Benjamin E (1989) Determination of intra-abdominal pressure using a transurethral bladder catheter: clinical validation of the technique. Anesthesiology 70:47–50PubMedCrossRef Iberti TJ, Lieber CE, Benjamin E (1989) Determination of intra-abdominal pressure using a transurethral bladder catheter: clinical validation of the technique. Anesthesiology 70:47–50PubMedCrossRef
18.
Zurück zum Zitat Dolan LM, Dixon WE, Brown K, Ord T, Hilton P (2005) Randomized comparison of vaginal and rectal measurement of intra-abdominal pressure during subtracted dual-channel cystometry. Urology 65:1059–63PubMedCrossRef Dolan LM, Dixon WE, Brown K, Ord T, Hilton P (2005) Randomized comparison of vaginal and rectal measurement of intra-abdominal pressure during subtracted dual-channel cystometry. Urology 65:1059–63PubMedCrossRef
19.
Zurück zum Zitat Wall LL, Hewitt JK, Helms MJ (1995) Are vaginal and rectal pressures equivalent approximations of one another for the purpose of performing subtracted cystometry? Obstet Gynecol 85:488–93PubMedCrossRef Wall LL, Hewitt JK, Helms MJ (1995) Are vaginal and rectal pressures equivalent approximations of one another for the purpose of performing subtracted cystometry? Obstet Gynecol 85:488–93PubMedCrossRef
20.
Zurück zum Zitat Gray M (2010) Traces: making sense of urodynamics testing. Urol Nurs 30:267–75PubMed Gray M (2010) Traces: making sense of urodynamics testing. Urol Nurs 30:267–75PubMed
Metadaten
Titel
Clinical evaluation of a wireless intra-vaginal pressure transducer
verfasst von
Yvonne Hsu
Tanner J. Coleman
Robert W. Hitchcock
Kristina Heintz
Janet M. Shaw
Ingrid E. Nygaard
Publikationsdatum
01.12.2012
Verlag
Springer-Verlag
Erschienen in
International Urogynecology Journal / Ausgabe 12/2012
Print ISSN: 0937-3462
Elektronische ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-012-1811-2

Weitere Artikel der Ausgabe 12/2012

International Urogynecology Journal 12/2012 Zur Ausgabe

BriefCommunication

Urogynecology digest

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.