Background

Ultrafast brain MRI is required for uncooperative patients and time-critical diseases such as stroke because it reduces scan times and motion artifacts. This study investigated the clinical feasibility of a 1-min ultrafast brain MRI protocol for detecting intracranial abnormalities in restless and uncooperative patients.

Methods

We retrospectively reviewed the records of 25 patients who underwent a 1-min ultrafast MRI protocol using T1-weighted image, T2-weighted image, echo-planar fluid-attenuated inversion recovery, diffusion-weighted image, and T2*-weighted image between March 2017 and May 2017. Simple methods were applied for ultrafast MRI protocol to reduce scan time as follows: parallel imaging techniques, multiband technique on diffusion sequence, and echo-planar fluid-attenuated inversion recovery. The images were compared with the routine brain MRI protocol using synthetic MRI, and quality was assessed by two independent readers. The Wilcoxon signed-rank test was used to compare the readers’ ratings of the routine MRI protocol and ultrafast MRI protocol images.

Results

Using a four-point assessment scale, overall image quality and anatomical delineation of ultrafast brain MRI images were lower than those of routine brain MRI images. However, the ultrafast protocol demonstrated sufficient overall image quality and anatomical delineation with an assessment rating greater than two points. The ultrafast protocol had fewer artifacts than the routine protocol using synthetic MRI.

Conclusions

Although the overall image quality and anatomical delineation of the 1-min ultrafast MRI were inferior to those of the routine brain MRI protocol, the ultrafast protocol showed at least sufficient image quality. Therefore, this protocol may be an option in specific clinical situations involving non-cooperative, restless, or pediatric patients, or patients with time-critical disease such as stroke. Further study is required to validate our findings.
Literatur
1.
Zurück zum Zitat Blystad I, Warntjes JB, Smedby O, Landtblom AM, Lundberg P, Larsson EM (2012) Synthetic MRI of the brain in a clinical setting. Acta Radiol 53:1158–1163CrossRefPubMed Blystad I, Warntjes JB, Smedby O, Landtblom AM, Lundberg P, Larsson EM (2012) Synthetic MRI of the brain in a clinical setting. Acta Radiol 53:1158–1163CrossRefPubMed
2.
Zurück zum Zitat Heidemann RM, Ozsarlak O, Parizel PM, Michiels J, Kiefer B, Jellus V, Müller M, Breuer F, Blaimer M, Griswold MA, Jakob PM (2003) A brief review of parallel magnetic resonance imaging. Eur Radiol 13:2323–2337CrossRef Heidemann RM, Ozsarlak O, Parizel PM, Michiels J, Kiefer B, Jellus V, Müller M, Breuer F, Blaimer M, Griswold MA, Jakob PM (2003) A brief review of parallel magnetic resonance imaging. Eur Radiol 13:2323–2337CrossRef
3.
Zurück zum Zitat Warntjes JB, Leinhard OD, West J, Lundberg P (2008) Rapid magnetic resonance quantification on the brain: optimization for clinical usage. Magn Reson Med 60:320–329CrossRefPubMed Warntjes JB, Leinhard OD, West J, Lundberg P (2008) Rapid magnetic resonance quantification on the brain: optimization for clinical usage. Magn Reson Med 60:320–329CrossRefPubMed
4.
Zurück zum Zitat Granberg T, Uppman M, Hashim F, Cananau C, Nordin LE, Shams S, Berglund J, Forslin Y, Aspelin P, Fredrikson S, Kristoffersen-Wiberg M (2016) Clinical feasibility of synthetic MRI in multiple sclerosis: a diagnostic and volumetric validation study. AJNR Am J Neuroradiol 37:1023–1029CrossRef Granberg T, Uppman M, Hashim F, Cananau C, Nordin LE, Shams S, Berglund J, Forslin Y, Aspelin P, Fredrikson S, Kristoffersen-Wiberg M (2016) Clinical feasibility of synthetic MRI in multiple sclerosis: a diagnostic and volumetric validation study. AJNR Am J Neuroradiol 37:1023–1029CrossRef
5.
Zurück zum Zitat Tanenbaum LN, Tsiouris AJ, Johnson AN, Naidich TP, DeLano MC, Melhem ER, Quarterman P, Parameswaran SX, Shankaranarayanan A, Goyen M, Field AS (2017) Synthetic MRI for clinical neuroimaging: results of the magnetic resonance image compilation (MAGiC) prospective, multicenter, multireader trial. AJNR Am J Neuroradiol 38:1103–1110CrossRef Tanenbaum LN, Tsiouris AJ, Johnson AN, Naidich TP, DeLano MC, Melhem ER, Quarterman P, Parameswaran SX, Shankaranarayanan A, Goyen M, Field AS (2017) Synthetic MRI for clinical neuroimaging: results of the magnetic resonance image compilation (MAGiC) prospective, multicenter, multireader trial. AJNR Am J Neuroradiol 38:1103–1110CrossRef
6.
Zurück zum Zitat Betts AM, Leach JL, Jones BV, Zhang B, Serai S (2016) Brain imaging with synthetic MR in children: clinical quality assessment. Neuroradiology 58:1017–1026CrossRefPubMed Betts AM, Leach JL, Jones BV, Zhang B, Serai S (2016) Brain imaging with synthetic MR in children: clinical quality assessment. Neuroradiology 58:1017–1026CrossRefPubMed
8.
Zurück zum Zitat Gulani V, Schmitt P, Griswold MA, Webb AG, Jakob PM (2004) Towards a single-sequence neurologic magnetic resonance imaging examination: multiple-contrast images from an IR TrueFISP experiment. Investig Radiol 39:767–774CrossRef Gulani V, Schmitt P, Griswold MA, Webb AG, Jakob PM (2004) Towards a single-sequence neurologic magnetic resonance imaging examination: multiple-contrast images from an IR TrueFISP experiment. Investig Radiol 39:767–774CrossRef
9.
Zurück zum Zitat Hagiwara A, Warntjes M, Hori M, Andica C, Nakazawa M, Kumamaru KK, Abe O, Aoki S (2017) SyMRI of the brain: rapid quantification of relaxation rates and proton density, with synthetic MRI, automatic brain segmentation, and myelin measurement. Investig Radiol 52:647–657CrossRef Hagiwara A, Warntjes M, Hori M, Andica C, Nakazawa M, Kumamaru KK, Abe O, Aoki S (2017) SyMRI of the brain: rapid quantification of relaxation rates and proton density, with synthetic MRI, automatic brain segmentation, and myelin measurement. Investig Radiol 52:647–657CrossRef
10.
Zurück zum Zitat Barth M, Breuer F, Koopmans PJ, Norris DG, Poser BA (2016) Simultaneous multislice (SMS) imaging techniques. Magn Reson Med 75:63–81CrossRefPubMed Barth M, Breuer F, Koopmans PJ, Norris DG, Poser BA (2016) Simultaneous multislice (SMS) imaging techniques. Magn Reson Med 75:63–81CrossRefPubMed
11.
Zurück zum Zitat Prakkamakul S, Witzel T, Huang S, Boulter D, Borja MJ, Schaefer P, Rosen B, Heberlein K, Ratai E, Gonzalez G, Rapalino O (2016) Ultrafast brain MRI: clinical deployment and comparison to conventional brain MRI at 3 T. J Neuroimaging 26:503–510CrossRefPubMed Prakkamakul S, Witzel T, Huang S, Boulter D, Borja MJ, Schaefer P, Rosen B, Heberlein K, Ratai E, Gonzalez G, Rapalino O (2016) Ultrafast brain MRI: clinical deployment and comparison to conventional brain MRI at 3 T. J Neuroimaging 26:503–510CrossRefPubMed
12.
Zurück zum Zitat Fagundes J, Longo MG, Huang SY, Rosen BR, Witzel T, Heberlein K, Gonzalez RG, Schaefer P, Rapalino O (2017) Diagnostic performance of a 10-minute gadolinium-enhanced brain MRI protocol compared with the standard clinical protocol for detection of intracranial enhancing lesions. AJNR Am J Neuroradiol 38:1689–1694CrossRefPubMed Fagundes J, Longo MG, Huang SY, Rosen BR, Witzel T, Heberlein K, Gonzalez RG, Schaefer P, Rapalino O (2017) Diagnostic performance of a 10-minute gadolinium-enhanced brain MRI protocol compared with the standard clinical protocol for detection of intracranial enhancing lesions. AJNR Am J Neuroradiol 38:1689–1694CrossRefPubMed
13.
Zurück zum Zitat U-King-Im JM, Trivedi RA, Graves MJ, Harkness K, Eales H, Joubert I, Koo B, Antoun N, Warburton EA, Gillard JH, Baron JC (2005) Utility of an ultrafast magnetic resonance imaging protocol in recent and semi-recent strokes. J Neurol Neurosurg Psychiatry 76:1002–1005CrossRefPubMedPubMedCentral U-King-Im JM, Trivedi RA, Graves MJ, Harkness K, Eales H, Joubert I, Koo B, Antoun N, Warburton EA, Gillard JH, Baron JC (2005) Utility of an ultrafast magnetic resonance imaging protocol in recent and semi-recent strokes. J Neurol Neurosurg Psychiatry 76:1002–1005CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Nael K, Khan R, Choudhary G, Meshksar A, Villablanca P, Tay J, Drake K, Coull BM, Kidwell CS (2014) Six-minute magnetic resonance imaging protocol for evaluation of acute ischemic stroke: pushing the boundaries. Stroke 45:1985–1991CrossRefPubMed Nael K, Khan R, Choudhary G, Meshksar A, Villablanca P, Tay J, Drake K, Coull BM, Kidwell CS (2014) Six-minute magnetic resonance imaging protocol for evaluation of acute ischemic stroke: pushing the boundaries. Stroke 45:1985–1991CrossRefPubMed
15.
Zurück zum Zitat Patel DM, Tubbs RS, Pate G, Johnston JM Jr, Blount JP (2014) Fast-sequence MRI studies for surveillance imaging in pediatric hydrocephalus. J Neurosurg Pediatr 13:440–447CrossRefPubMed Patel DM, Tubbs RS, Pate G, Johnston JM Jr, Blount JP (2014) Fast-sequence MRI studies for surveillance imaging in pediatric hydrocephalus. J Neurosurg Pediatr 13:440–447CrossRefPubMed
16.
Zurück zum Zitat Likert R (1932) A technique for the measurement of attitudes. Arch Psychol 22:1–55 Likert R (1932) A technique for the measurement of attitudes. Arch Psychol 22:1–55
17.
Zurück zum Zitat Skare S, Sprenger T, Norbeck O, Rydén H, Blomberg L, Avventi E, Engström M (2018) A 1-minute full brain MR exam using a multicontrast EPI sequence. Magn Reson Med 79:3045–3054CrossRefPubMed Skare S, Sprenger T, Norbeck O, Rydén H, Blomberg L, Avventi E, Engström M (2018) A 1-minute full brain MR exam using a multicontrast EPI sequence. Magn Reson Med 79:3045–3054CrossRefPubMed
18.
Zurück zum Zitat Tomura N, Kato K, Takahashi S, Sashi R, Izumi J, Narita K, Watarai J (2002) Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging. Comput Med Imaging Gr 26:65–72CrossRef Tomura N, Kato K, Takahashi S, Sashi R, Izumi J, Narita K, Watarai J (2002) Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging. Comput Med Imaging Gr 26:65–72CrossRef
19.
Zurück zum Zitat Korogi Y, Sugahara T, Shigematsu Y, Ikushima I, Hirai T, Okuda T, Takahashi M (1999) Ultrafast FLAIR imaging with single-shot echo-planar technique in evaluation of intracranial lesions. Comput Med Imaging Gr 23:119–126CrossRef Korogi Y, Sugahara T, Shigematsu Y, Ikushima I, Hirai T, Okuda T, Takahashi M (1999) Ultrafast FLAIR imaging with single-shot echo-planar technique in evaluation of intracranial lesions. Comput Med Imaging Gr 23:119–126CrossRef
20.
Zurück zum Zitat Pruessmann KP (2004) Parallel imaging at high field strength: synergies and joint potential. Top Magn Reson Imaging 15:237–244CrossRefPubMed Pruessmann KP (2004) Parallel imaging at high field strength: synergies and joint potential. Top Magn Reson Imaging 15:237–244CrossRefPubMed
21.
Zurück zum Zitat Wiesinger F, Van de Moortele PF, Adriany G, De Zanche N, Ugurbil K, Pruessmann KP (2006) Potential and feasibility of parallel MRI at high field. NMR Biomed 19:368–378CrossRefPubMed Wiesinger F, Van de Moortele PF, Adriany G, De Zanche N, Ugurbil K, Pruessmann KP (2006) Potential and feasibility of parallel MRI at high field. NMR Biomed 19:368–378CrossRefPubMed
22.
Zurück zum Zitat Viera AJ, Garrett JM (2005) Understanding interobserver agreement: the kappa statistic. Fam Med 37:360–363 Viera AJ, Garrett JM (2005) Understanding interobserver agreement: the kappa statistic. Fam Med 37:360–363
23.
Zurück zum Zitat Feinstein AR, Cicchetti DV (1990) High agreement but low kappa: I. The problems of two paradoxes. J Clin Epidemiol 43:543–549CrossRef Feinstein AR, Cicchetti DV (1990) High agreement but low kappa: I. The problems of two paradoxes. J Clin Epidemiol 43:543–549CrossRef
Metadaten
Titel
Clinical feasibility of 1-min ultrafast brain MRI compared with routine brain MRI using synthetic MRI: a single center pilot study
verfasst von
Kyeong Hwa Ryu
Dae Seob Choi
Hye Jin Baek
Soo Buem Cho
Ji Young Ha
Tae Byeong Kim
Moon Jung Hwang
Publikationsdatum
07.12.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
Journal of Neurology / Ausgabe 2/2019
Print ISSN: 0340-5354
Elektronische ISSN: 1432-1459
DOI
https://doi.org/10.1007/s00415-018-9149-4

Kompaktes Leitlinien-Wissen Neurologie (Link öffnet in neuem Fenster)

Mit medbee Pocketcards schnell und sicher entscheiden.
Leitlinien-Wissen kostenlos und immer griffbereit auf ihrem Desktop, Handy oder Tablet.

Neu im Fachgebiet Neurologie

„Wir wollen die Bedeutung von Gen- und Umwelteinflüssen besser verstehen“

Eine Mutation in einem einzelnen Gen kann bei Mäusen eine Art Bipolarstörung auslösen. PD Dr. Jan Deussing vom Max-Planck-Institut für Psychiatrie in München sieht in solchen Tiermodellen eine Möglichkeit, den Ursachen der Erkrankung auf den Grund zu gehen.

Suizidassistenz erhöht Suizidzahlen: Aktuelle Ergebnisse der geplanten S3-Leitlinie

Erstmals wird in Deutschland eine S3-Leitlinie zum Thema Suizidalität erarbeitet. Ziel ist es, die Versorgung in suizidalen Krisen durch einheitliche Standards zu verbessern. Erste Ergebnisse der bisherigen Leitlinienarbeit wurden auf dem DGPPN-Kongress vorgestellt.

Kaum Vorteile durch intraarterielle Lyse während Thrombektomie

Nach der Thrombektomie kleinere Fragmente über eine intraarterielle Lyse auflösen – dies könnte die Schlaganfalltherapie verbessern. Zwei aktuelle Studien ergeben für die periprozedurale Lyse jedoch keine großen Vorteile. Die Frage, wie viel sie nützt, bleibt weiter offen.

Nasenstimulation lindert chronische Migräne

Wird die Naseninnenseite durch Vibrationen stimuliert, kann dies offenbar die Zahl der Migränetage von Menschen mit chronischer Migräne deutlich senken. Darauf deuten die Resultate einer randomisiert-kontrollierten deutsch-finnischen Untersuchung.

Update Neurologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.