Abstract

Objectives

After middle ear reconstruction using partial or total ossicular replacement prostheses (PORP/TORP), an air–bone gap (ABG) may persist because of prosthesis displacement or malposition. So far, CT of the temporal bone has played the main role in the diagnosis of reasons for postoperative insufficient ABG improvement. Recent experimental and clinical studies have evaluated flat panel CT (fpCT) as an alternative imaging technique that provides images with high isovolumetric resolution, fewer metal-induced artefacts and lower irradiation doses.

Methods

One hundred and seven consecutive patients with chronic otitis media with or without cholesteatoma underwent reconstruction by PORP (n = 52) or TORP (n = 55). All subjects underwent preoperative and postoperative audiometric testing and postoperative fpCT.

Results

Statistical evaluation of all 107 patients as well as the sole sub-assembly groups (PORP or TORP) showed a highly significant correlation between hearing improvement and fpCT-determined prosthesis position. FpCT enables detailed postoperative information on patients with middle ear reconstruction.

Conclusions

FpCT is a new imaging technique that provides immediate feedback on surgical results after reconstructive middle ear surgery. Specific parameters evaluated by fpCT may serve as a predictive tool for estimated postoperative hearing improvement. Therefore this imaging technique is suitable for postoperative quality control in reconstructive middle ear surgery.

Key Points

Flat panel CT offers advantages with regard to artefacts and radiation dose.
FpCT provides higher isovolumetric resolution of temporal bone and middle ear implants.
FpCT allows prediction of the postoperative hearing outcome in patients.
FpCT is an important tool for immediate postoperative quality control.
FpCT improves postoperative management of patients with complications following ossicular replacement
Literatur
1.
Zurück zum Zitat Begall K, Zimmermann H (2000) Reconstruction of the ossicular chain with titanium implants. Results of a multicenter study. Laryngorhinootologie 79:139–145PubMedCrossRef Begall K, Zimmermann H (2000) Reconstruction of the ossicular chain with titanium implants. Results of a multicenter study. Laryngorhinootologie 79:139–145PubMedCrossRef
2.
Zurück zum Zitat Bernal-Sprekelsen M, Romaguera Lliso MD, Sanz Gonzalo JJ (2003) Cartilage palisades in type III tympanoplasty: anatomic and functional long-term results. Otol Neurotol 24:38–42PubMedCrossRef Bernal-Sprekelsen M, Romaguera Lliso MD, Sanz Gonzalo JJ (2003) Cartilage palisades in type III tympanoplasty: anatomic and functional long-term results. Otol Neurotol 24:38–42PubMedCrossRef
3.
Zurück zum Zitat Dost P, Wiemann M, ten Cate WJ (2005) Biomaterial studies in cultures of human stapedial bone-like cells. HNO 53:545–547PubMedCrossRef Dost P, Wiemann M, ten Cate WJ (2005) Biomaterial studies in cultures of human stapedial bone-like cells. HNO 53:545–547PubMedCrossRef
4.
Zurück zum Zitat Sudhoff H, Lindner N, Gronemeyer J, Dazert S, Hildmann H (2005) Study of osteointegration of a titanium prosthesis to the stapes: observations on an accidentally extracted stapes. Otol Neurotol 26:583–586PubMedCrossRef Sudhoff H, Lindner N, Gronemeyer J, Dazert S, Hildmann H (2005) Study of osteointegration of a titanium prosthesis to the stapes: observations on an accidentally extracted stapes. Otol Neurotol 26:583–586PubMedCrossRef
5.
Zurück zum Zitat Asai M, Huber AM, Goode RL (1999) Analysis of the best site on the stapes footplate for ossicular chain reconstruction. Acta Otolaryngol 119:356–361PubMedCrossRef Asai M, Huber AM, Goode RL (1999) Analysis of the best site on the stapes footplate for ossicular chain reconstruction. Acta Otolaryngol 119:356–361PubMedCrossRef
6.
Zurück zum Zitat Fisch U, May J, Linder T, Naumann IC (2004) A new L-shaped titanium prosthesis for total reconstruction of the ossicular chain. Otol Neurotol 25:891–902PubMedCrossRef Fisch U, May J, Linder T, Naumann IC (2004) A new L-shaped titanium prosthesis for total reconstruction of the ossicular chain. Otol Neurotol 25:891–902PubMedCrossRef
7.
Zurück zum Zitat Huttenbrink KB, Zahnert T, Wustenberg EG, Hofmann G (2004) Titanium clip prosthesis. Otol Neurotol 25:436–442PubMedCrossRef Huttenbrink KB, Zahnert T, Wustenberg EG, Hofmann G (2004) Titanium clip prosthesis. Otol Neurotol 25:436–442PubMedCrossRef
8.
Zurück zum Zitat Rosowski JJ, Merchant SN (1995) Mechanical and acoustic analysis of middle ear reconstruction. Am J Otol 16:486–497PubMed Rosowski JJ, Merchant SN (1995) Mechanical and acoustic analysis of middle ear reconstruction. Am J Otol 16:486–497PubMed
9.
Zurück zum Zitat Schwager K (2002) Titanium as a material for ossicular replacement—basic aspects and clinical application. Laryngorhinootologie 81:178–183PubMedCrossRef Schwager K (2002) Titanium as a material for ossicular replacement—basic aspects and clinical application. Laryngorhinootologie 81:178–183PubMedCrossRef
10.
11.
Zurück zum Zitat Offergeld C, Kromeier J, Aschendorff A et al (2007) Rotational tomography of the normal and reconstructed middle ear in temporal bones: an experimental study. Eur Arch Otorhinolaryngol 264:345–351PubMedCrossRef Offergeld C, Kromeier J, Aschendorff A et al (2007) Rotational tomography of the normal and reconstructed middle ear in temporal bones: an experimental study. Eur Arch Otorhinolaryngol 264:345–351PubMedCrossRef
12.
Zurück zum Zitat Bozzato A, Struffert T, Hertel V, Iro H, Hornung J (2010) Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses. Eur Radiol 20:566–571PubMedCrossRef Bozzato A, Struffert T, Hertel V, Iro H, Hornung J (2010) Analysis of the accuracy of high-resolution computed tomography techniques for the measurement of stapes prostheses. Eur Radiol 20:566–571PubMedCrossRef
13.
Zurück zum Zitat Naumann IC, Porcellini B, Fisch U (2005) Otosclerosis: incidence of positive findings on high-resolution computed tomography and their correlation to audiological test data. Ann Otol Rhinol Laryngol 114:709–716PubMed Naumann IC, Porcellini B, Fisch U (2005) Otosclerosis: incidence of positive findings on high-resolution computed tomography and their correlation to audiological test data. Ann Otol Rhinol Laryngol 114:709–716PubMed
14.
Zurück zum Zitat Aschendorff A, Kubalek R, Hochmuth A et al (2004) Imaging procedures in cochlear implant patients—evaluation of different radiological techniques. Acta Otolaryngol Suppl 552:46–49PubMedCrossRef Aschendorff A, Kubalek R, Hochmuth A et al (2004) Imaging procedures in cochlear implant patients—evaluation of different radiological techniques. Acta Otolaryngol Suppl 552:46–49PubMedCrossRef
15.
Zurück zum Zitat Zaoui K, Kromeier J, Neudert M et al (2012) Flat panel CT following stapes prosthesis insertion: an experimental and clinical study. Eur Radiol 22:837–844PubMedCrossRef Zaoui K, Kromeier J, Neudert M et al (2012) Flat panel CT following stapes prosthesis insertion: an experimental and clinical study. Eur Radiol 22:837–844PubMedCrossRef
16.
Zurück zum Zitat Offergeld C, Kromeier J, Merchant SN et al (2010) Experimental investigation of rotational tomography in reconstructed middle ears with clinical implications. Hear Res 263:191–197PubMedCentralPubMedCrossRef Offergeld C, Kromeier J, Merchant SN et al (2010) Experimental investigation of rotational tomography in reconstructed middle ears with clinical implications. Hear Res 263:191–197PubMedCentralPubMedCrossRef
17.
Zurück zum Zitat Offergeld C (2013) Quality control following reconstructive middle ear surgery: From bench to bedside. HNO Offergeld C (2013) Quality control following reconstructive middle ear surgery: From bench to bedside. HNO
18.
Zurück zum Zitat De Vos C, Gersdorff M, Gerard JM (2007) Prognostic factors in ossiculoplasty. Otol Neurotol 28:61–67PubMedCrossRef De Vos C, Gersdorff M, Gerard JM (2007) Prognostic factors in ossiculoplasty. Otol Neurotol 28:61–67PubMedCrossRef
19.
Zurück zum Zitat Morris DP, Bance M, van Wijhe RG, Kiefte M, Smith R (2004) Optimum tension for partial ossicular replacement prosthesis reconstruction in the human middle ear. Laryngoscope 114:305–308PubMedCrossRef Morris DP, Bance M, van Wijhe RG, Kiefte M, Smith R (2004) Optimum tension for partial ossicular replacement prosthesis reconstruction in the human middle ear. Laryngoscope 114:305–308PubMedCrossRef
20.
Zurück zum Zitat Yung M (2006) Long-term results of ossiculoplasty: reasons for surgical failure. Otol Neurotol 27:20–26PubMedCrossRef Yung M (2006) Long-term results of ossiculoplasty: reasons for surgical failure. Otol Neurotol 27:20–26PubMedCrossRef
21.
Zurück zum Zitat Yung M, Vowler SL (2006) Long-term results in ossiculoplasty: an analysis of prognostic factors. Otol Neurotol 27:874–881PubMedCrossRef Yung M, Vowler SL (2006) Long-term results in ossiculoplasty: an analysis of prognostic factors. Otol Neurotol 27:874–881PubMedCrossRef
22.
Zurück zum Zitat Rodt T, Bartling S, Schmidt AM, Weber BP, Lenarz T, Becker H (2002) Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography. Eur Radiol 12:1684–1692PubMedCrossRef Rodt T, Bartling S, Schmidt AM, Weber BP, Lenarz T, Becker H (2002) Virtual endoscopy of the middle ear: experimental and clinical results of a standardised approach using multi-slice helical computed tomography. Eur Radiol 12:1684–1692PubMedCrossRef
24.
Zurück zum Zitat Chuang MT, Chiang IC, Liu GC, Lin WC (2006) Multidetector row CT demonstration of inner and middle ear structures. Clin Anat 19:337–344PubMedCrossRef Chuang MT, Chiang IC, Liu GC, Lin WC (2006) Multidetector row CT demonstration of inner and middle ear structures. Clin Anat 19:337–344PubMedCrossRef
25.
Zurück zum Zitat Roosli C, Hoffmann A, Treumann T, Linder TE (2008) Significance of computed tomography evaluation before revision stapes surgery. HNO 56:895–900PubMedCrossRef Roosli C, Hoffmann A, Treumann T, Linder TE (2008) Significance of computed tomography evaluation before revision stapes surgery. HNO 56:895–900PubMedCrossRef
26.
Zurück zum Zitat Hahn Y, Diaz R, Hartman J, Bobinski M, Brodie H (2009) Assessing stapes piston position using computed tomography: a cadaveric study. Otol Neurotol 30:223–230PubMedCrossRef Hahn Y, Diaz R, Hartman J, Bobinski M, Brodie H (2009) Assessing stapes piston position using computed tomography: a cadaveric study. Otol Neurotol 30:223–230PubMedCrossRef
27.
Zurück zum Zitat Bartling SH, Majdani O, Gupta R et al (2007) Large scan field, high spatial resolution flat-panel detector based volumetric CT of the whole human skull base and for maxillofacial imaging. Dentomaxillofac Radiol 36:317–327PubMedCrossRef Bartling SH, Majdani O, Gupta R et al (2007) Large scan field, high spatial resolution flat-panel detector based volumetric CT of the whole human skull base and for maxillofacial imaging. Dentomaxillofac Radiol 36:317–327PubMedCrossRef
28.
Zurück zum Zitat Trieger A, Schulze A, Schneider M, Zahnert T, Murbe D (2011) In vivo measurements of the insertion depth of cochlear implant arrays using flat-panel volume computed tomography. Otol Neurotol 32:152–157PubMedCrossRef Trieger A, Schulze A, Schneider M, Zahnert T, Murbe D (2011) In vivo measurements of the insertion depth of cochlear implant arrays using flat-panel volume computed tomography. Otol Neurotol 32:152–157PubMedCrossRef
29.
Zurück zum Zitat Zeitler DM, Wang KH, Prasad RS, Wang EY, Roland JT (2011) Flat-panel computed tomography versus multislice computed tomography to evaluate cochlear implant positioning. Cochlear Implants Int 12:216–222PubMedCrossRef Zeitler DM, Wang KH, Prasad RS, Wang EY, Roland JT (2011) Flat-panel computed tomography versus multislice computed tomography to evaluate cochlear implant positioning. Cochlear Implants Int 12:216–222PubMedCrossRef
30.
Zurück zum Zitat Offergeld C, Pilling E, Lazurashvili N et al (2007) Conventional tomographic investigations of the reconstructed middle ear in temporal bone specimen. Laryngorhinootologie 86:501–506PubMedCrossRef Offergeld C, Pilling E, Lazurashvili N et al (2007) Conventional tomographic investigations of the reconstructed middle ear in temporal bone specimen. Laryngorhinootologie 86:501–506PubMedCrossRef
31.
Zurück zum Zitat Choi HG, Lee DH, Chang KH, Yeo SW, Yoon SH, Jun BC (2011) Frequency-specific hearing results after surgery for chronic ear diseases. Clin Exp Otorhinolaryngol 4:126–130PubMedCentralPubMedCrossRef Choi HG, Lee DH, Chang KH, Yeo SW, Yoon SH, Jun BC (2011) Frequency-specific hearing results after surgery for chronic ear diseases. Clin Exp Otorhinolaryngol 4:126–130PubMedCentralPubMedCrossRef
Metadaten
Titel
Clinical investigation of flat panel CT following middle ear reconstruction: a study of 107 patients
Publikationsdatum
01.03.2014
Erschienen in
European Radiology / Ausgabe 3/2014
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-013-3068-7

Weitere Artikel der Ausgabe 3/2014

European Radiology 3/2014 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.