Clinical value of high-resolution (5–17 MHz) echo-color Doppler (ECD) for identifying filling materials and assessment of damage or complications in aesthetic medicine/surgery

verfasst von: Maria Scotto di Santolo, Candida Massimo, Giovanni Tortora, Valeria Romeo, Michele Amitrano, Arturo Brunetti, Massimo Imbriaco

Erschienen in: La radiologia medica | Ausgabe 6/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this retrospective study is to evaluate the role of echo-color-Doppler (ECD) imaging in identifying a series of characteristics pursuant to aesthetic filling material such as their degree of absorbability and their potential complications which include their propensity to stimulate the formation of encapsulated foreign-body granulomas. In the latter case, ECD can be of aid by giving indication for surgical therapy.

Materials and Methods

Over a 4-year period, we studied 180 patients (60 ♂) who underwent an aesthetic medical/surgical treatment. We used ECD to evaluate the implant material, its thickness, the injection site, the integrity of dermal layers and the presence of any associated complications.

Results

In 97% (174/180) of our patients, we were able to identify the type of material used; furthermore, 57% of patients had a hyaluronic acid implant, 14% a lipofilling and 29% a non-absorbable filler (with 10% of silicone). In 6/180 (3%), we could not recognize the material used; 89% (161/180) of our patients presented post-injection complications; moreover, 67% showed peri-implant dermal–hypodermal thickening areas with adjacent lymphostasis, 6% displayed an abnormal implant site, and 17% showed inflammation with encapsulated foreign-body granulomas that required subsequent surgical excision. Biopsy samples were obtained from 37/180 patients (21%); among these, 31 patients had an ECD evidence of granuloma and on 6 patients we were not able to define the injected material. Histopathological examination identified 29 granulomas, 5 sterile abscesses and 3 chronic inflammations in the absence of granuloma. ECD showed an overall 78% diagnostic accuracy, with 90% sensitivity and 37% specificity in detecting filler granulomas.

Conclusion

ECD is a low-cost technique that allows to identify filling materials and to assess the complications of an esthetic medical/surgical treatment.
Literatur
2.
3.
Zurück zum Zitat Alexander H, Miller DL (1979) Determining skin thickness with pulsed ultrasound. J Invest Dermatol 72(1):17–19CrossRefPubMed Alexander H, Miller DL (1979) Determining skin thickness with pulsed ultrasound. J Invest Dermatol 72(1):17–19CrossRefPubMed
4.
Zurück zum Zitat Wortsman X, Alfageme F, Roustan G, Arias Santiago S, Martorell A, Catalano O, Scotto di Santolo M, Zarchi K, Bouer M, Gonzalez C, Bard R, Mandava A, Gaitini D (2016) Guidelines for performing dermatologic ultrasound examinations by the DERMUS group. J Ultrasound Med 35:111–114CrossRef Wortsman X, Alfageme F, Roustan G, Arias Santiago S, Martorell A, Catalano O, Scotto di Santolo M, Zarchi K, Bouer M, Gonzalez C, Bard R, Mandava A, Gaitini D (2016) Guidelines for performing dermatologic ultrasound examinations by the DERMUS group. J Ultrasound Med 35:111–114CrossRef
5.
Zurück zum Zitat Wortsman X, Alfageme F, Roustan G, Arias Santiago S, Martorell A, Catalano O, Scotto di Santolo M, Zarchi K, Bouer M, Gonzalez C, Bard R, Mandava A, Gaitini D (2016) Proposal for an Assessment Training Program in Dermatologic Ultrasound by the DERMUS Group. J Ultrasound Med 35:e5–e9.|https://doi.org/10.7863/ultra.15.10068 Wortsman X, Alfageme F, Roustan G, Arias Santiago S, Martorell A, Catalano O, Scotto di Santolo M, Zarchi K, Bouer M, Gonzalez C, Bard R, Mandava A, Gaitini D (2016) Proposal for an Assessment Training Program in Dermatologic Ultrasound by the DERMUS Group. J Ultrasound Med 35:e5–e9.|https://​doi.​org/​10.​7863/​ultra.​15.​10068
7.
Zurück zum Zitat Daines SM, Williams EF. Complications associated with injectable soft tissue fillers: a 5-year retrospective review. JAMA Facial Plast Surg 15:226–231 Daines SM, Williams EF. Complications associated with injectable soft tissue fillers: a 5-year retrospective review. JAMA Facial Plast Surg 15:226–231
8.
Zurück zum Zitat Callan P, Goodman GJ, Carlisle I et al (2013) Efficacy and safety of a hyaluronic acid filler in subjects treated for correction of midface volume deficiency: a 24 month study. Clin Cosmet Investig Dermatol 6:81–89CrossRefPubMedPubMedCentral Callan P, Goodman GJ, Carlisle I et al (2013) Efficacy and safety of a hyaluronic acid filler in subjects treated for correction of midface volume deficiency: a 24 month study. Clin Cosmet Investig Dermatol 6:81–89CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Wortsman X (2012) Common applications of dermatologic sonography. J Ultrasound Med 31(1):97–111CrossRefPubMed Wortsman X (2012) Common applications of dermatologic sonography. J Ultrasound Med 31(1):97–111CrossRefPubMed
11.
Zurück zum Zitat Wortsman X (2015) Identification and complications of cosmetic fillers: sonography first. J Ultrasound Med 34(7):1163–1172CrossRefPubMed Wortsman X (2015) Identification and complications of cosmetic fillers: sonography first. J Ultrasound Med 34(7):1163–1172CrossRefPubMed
12.
Zurück zum Zitat Costantino A, Fioramonti P, Ciotti M, Onesti MG (2012) Lipofilling in skin affected by radiodermatitis: clinical and ultrasound aspects. Case report. G Chir 33(5):186–190PubMed Costantino A, Fioramonti P, Ciotti M, Onesti MG (2012) Lipofilling in skin affected by radiodermatitis: clinical and ultrasound aspects. Case report. G Chir 33(5):186–190PubMed
15.
Zurück zum Zitat Young SR, Bolton PA, Downie J (2008) Use of high-frequency ultrasound in the assessment of injectable dermal fillers. Skin Res Technol 14:320–323CrossRefPubMed Young SR, Bolton PA, Downie J (2008) Use of high-frequency ultrasound in the assessment of injectable dermal fillers. Skin Res Technol 14:320–323CrossRefPubMed
16.
Zurück zum Zitat Grippaudo FR, Mattei M (2010) High-frequency sonography of temporary and permanent dermal fillers. Skin Res Technol 16:265–269PubMed Grippaudo FR, Mattei M (2010) High-frequency sonography of temporary and permanent dermal fillers. Skin Res Technol 16:265–269PubMed
17.
Zurück zum Zitat Schelke LW, Van Den Elzen HJ, Erkamp PP, Neumann HA (2010) Use of ultrasound to provide overall information on facial fillers and surrounding tissue. Dermatol Surg 36(suppl 3):1843–1851CrossRefPubMed Schelke LW, Van Den Elzen HJ, Erkamp PP, Neumann HA (2010) Use of ultrasound to provide overall information on facial fillers and surrounding tissue. Dermatol Surg 36(suppl 3):1843–1851CrossRefPubMed
18.
Zurück zum Zitat De Lorenzi C (2013) Complications of injectable fillers, part I. Aesthet Surg J 33:561–575CrossRef De Lorenzi C (2013) Complications of injectable fillers, part I. Aesthet Surg J 33:561–575CrossRef
19.
Zurück zum Zitat De Lorenzi C (2014) Complications of injectable fillers, part 2: vascular complications. Aesthet Surg J 34:584–600CrossRef De Lorenzi C (2014) Complications of injectable fillers, part 2: vascular complications. Aesthet Surg J 34:584–600CrossRef
20.
Zurück zum Zitat Dayan SH (2013) Complications from toxins and fillers in the dermatology clinic: recognition, prevention, and treatment. Facial Plast Surg Clin North Am 21:663–673CrossRefPubMed Dayan SH (2013) Complications from toxins and fillers in the dermatology clinic: recognition, prevention, and treatment. Facial Plast Surg Clin North Am 21:663–673CrossRefPubMed
Metadaten
Titel
Clinical value of high-resolution (5–17 MHz) echo-color Doppler (ECD) for identifying filling materials and assessment of damage or complications in aesthetic medicine/surgery
verfasst von
Maria Scotto di Santolo
Candida Massimo
Giovanni Tortora
Valeria Romeo
Michele Amitrano
Arturo Brunetti
Massimo Imbriaco
Publikationsdatum
01.06.2019
Verlag
Springer Milan
Erschienen in
La radiologia medica / Ausgabe 6/2019
Print ISSN: 0033-8362
Elektronische ISSN: 1826-6983
DOI
https://doi.org/10.1007/s11547-018-0969-1

Neu im Fachgebiet Radiologie

KI-gestütztes Mammografiescreening überzeugt im Praxistest

Mit dem Einsatz künstlicher Intelligenz lässt sich die Detektionsrate im Mammografiescreening offenbar deutlich steigern. Mehr unnötige Zusatzuntersuchungen sind laut der Studie aus Deutschland nicht zu befürchten.

Stumme Schlaganfälle − ein häufiger Nebenbefund im Kopf-CT?

In 4% der in der Notfallambulanz initiierten zerebralen Bildgebung sind „alte“ Schlaganfälle zu erkennen. Gar nicht so selten handelt es sich laut einer aktuellen Studie dabei um unbemerkte Insulte. Bietet sich hier womöglich die Chance auf ein effektives opportunistisches Screening?

Die elektronische Patientenakte kommt: Das sollten Sie jetzt wissen

Am 15. Januar geht die „ePA für alle“ zunächst in den Modellregionen an den Start. Doch schon bald soll sie in allen Praxen zum Einsatz kommen. Was ist jetzt zu tun? Was müssen Sie wissen? Wir geben in einem FAQ Antworten auf 21 Fragen.

Stören weiße Wände und viel Licht die Bildqualitätskontrolle?

Wenn es darum geht, die technische Qualität eines Mammogramms zu beurteilen, könnten graue Wandfarbe und reduzierte Beleuchtung im Bildgebungsraum von Vorteil sein. Darauf deuten zumindest Ergebnisse einer kleinen Studie hin. 

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.