Severe obesity is asscociated with an increased risk of coronary artery disease (CAD) but non-invasive cardiac imaging modalities have important technical limits.
Case presentation
We report a case of a 58-year old patient with suspected CAD and severely elevated BMI of 58 kg/m2.
Conclusions
Stress-CMR was able to non-invasively stratify risk with good imaging quality despite the body dimensions of the patient.
Abkürzungen
BMI
Body mass index
CAD
Coronary artery disease
CMR
Cardiac magnetic resonance
HLA
Horizontal long axis
MIBG
123I–metaiodobenzylguanidine
LGE
Late gadolinium enhancement
NAFLD
Nonalcoholic fatty liver disease
NYHA
New York Heart Failure Association
SAX
Short axis
SSFP
Steady-state free precession
VLA
Vertical long axis
Background
Severe obesity is defined as a body mass index (BMI) ≥40 kg/m2 and is independently asscociated with an increased risk of coronary artery disease (CAD) [1‐3]. Despite common use in the general population, conventional imaging modalities as stress-echo have important technical limits for overweight individuals. In nuclear medecine, some stress/rest perfusion protocols provide high image quality [4]. However, limitations for tracer uptakes in obese patients undergoing 123I–metaiodobenzylguanidine (MIBG)-scintygraphy, widely used for risk stratification in heart failure, have been reported [5]. Cardiac magnetic resonance (CMR) imaging perfusion, also known as stress-CMR, is not depending on acoustic windows and has been also reported to be safe and feasible in obese patients [2, 6, 7]. In addition, CMR is able to perform perfusion, viability and ventricular function within a single examination [7].
Case presentation
We are reporting a case of a 58-year old woman with a BMI of 58,08 kg/m2 who was referred for stress-CMR to our department. She had undergone ambulatory stress-echo but image quality was poor as a result of body habitus. No treadmill exercise test could be performed. She was reporting exertional dyspnea of NYHA class II and no history of chest pain, syncope or palpitations. Due to the patient’s extreme body weight and concomitant diabetes suspicion for CAD was raised. She did not use any medication and had no fevers, night sweats, upper respiratory symptoms, cough, nausea, vomiting, diarrhea, rash, arthralgias or urinary tract symptoms and no history of asthma or allergy to contrast agents. Blood pressure at admission was 149/79 mmHg, heart rate 75 beats per minute at rest. The 12-lead ECG showed sinus rhythm with slightly notched S in the inferior leads but no signs of cardiac hypertrophy. Laboratory-test prior to admission found elevated liver enzymes. Medical history included cholecystectomy several years ago. Abdominal ultrasound had shown nonalcoholic fatty liver disease (NAFLD) supposingly as a result of abnormal metabolism. Cholesterol levels where slightly elevated, hemoglobin A1c level of 8.2% indicated poor glycemic control.
Anzeige
We performed a stress-CMR on a Philips Ingenia 3.0 Tesla Scanner with a 70 cm wide bore system using phased array receive coils (16 elements anterior, 12 elements posterior) which allowed examination despite the body dimensions of the patient (Fig. 1A). Cine imaging with SSFP, perfusion and delayed hyperenhancement (LGE) protocol were started. Image acquisition was performed without any notable complications, the patient intermittently reported mild forms of chest pain and dypnea. The horizontal long axis (HLA), vertical long axis (VLA), and short axis (SAX) planes (Field of View 250 mm (x) /250 mm (y); Pixel spacing 1.12 mm (x) /1.12 mm (y); Flip angle 45°; Echo time 1,75 ms; Repetition time 3,5 ms; Image resolution 224 × 224 pixels) demonstrated preserved biventricular function with a LV-EF of 65% and normal ventricular and atrial dimensions. Mild concentric hypertrophy was seen, with a basal septum enddiastolic diameter of 12 mm. Regadenoson in a dose of 400 μg was administered as a vasodilatory agent, the total gadolinium dose was 22 mmol. Perfusion-images showed high diagnostic image quality throughout the protocol (Fig. 1C), comparable to perfusion-sequences in a normal-weight and obese individuals (Figs. 2 and 3). No exercised perfusion deficits indicating myocardial ischemia were detected in either one of the three acquired short-axis views and there was no sign of myocardial scar tissue in the LGE images (Fig. 1F).
×
×
×
Conclusions
Overall, stress-CMR was feasible and absence of ischemia or myocardial scar was documented in the examination. Due to the high negative predictive value of a negative stress-CMR, there was no need for further invasive cardiac examination [8]. Stress-CMR was able to non-invasively stratify risk with good imaging quality in a patient with suspected CAD and severely elevated BMI.
Acknowledgements
We would like to thank our MR technicians for helping with the high quality CMR examinations. We also thank Anne Gale for editorial assistance.
Funding
B.S. and S.K. were funded by Philips Healthcare. B.P. and S.K. received support from DZHK (German Center for Cardiovascular Research, Partner Site Berlin).
Anzeige
Availability of data and materials
All data and materials are available on request via the authors at the German Heart Center Berlin.
Ethics approval and consent to participate
All examinations were performed in accordance with all the ethical standards. Written informed consent was provided by the patient.
Consent for publication
Written consent to publish was provided by the patient.
Competing interests
The authors declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.