Skip to main content
Erschienen in: Heart and Vessels 1/2019

24.07.2018 | Original Article

Collateral closure in congenital heart defects with Amplatzer vascular plugs: single-center experience and a simplified delivery technique for exceptional cases

verfasst von: Rouven Kubicki, Brigitte Stiller, Johanna Hummel, Rene Höhn, Thilo Fleck, Jochen Grohmann

Erschienen in: Heart and Vessels | Ausgabe 1/2019

Einloggen, um Zugang zu erhalten

Abstract

The study describes our experience with Amplatzer Vascular Plugs (AVP2 and 4) and highlights a more refindes telescopic technique for AVP2 delivery. AVPs are well-established occlusion devices for vascular anomalies in congenital heart disease (CHD). The AVP2 is sometimes preferred to the AVP4 due to its shorter length, flat-profiled retention disks, and the availability of larger diameters, but its profile requires a larger inner lumen for safe delivery. The latter may actually hamper access to target lesions. This is a retrospective analysis of all CHD patients treated with the AVP2 and AVP4 between 12/2012 and 12/2015. Target vessels were characterized, measured, and the device-to-vessel diameter ratio calculated. A modified pigtail technique for AVP2 delivery was frequently used: a floppy wire was simply reinforced by the curved tip of a pigtail catheter (instead of the long sheath’s dilator) to guide the required delivery sheath towards the desired landing zone. 59 patients with a median age and bodyweight of 3.0 years (range 0.1–75) and 13.8 kg (range 2.5–80) underwent the implantation of 106 plug-devices (30 AVP2, 76 AVP4) in 91 target vessels. Indications for their use were ductus arteriosus (19%), aortopulmonary (43%) as well as venovenous collaterals (34%) and other miscellaneous lesions (4%). The pigtail-supported AVP2 delivery in six patients proved very convenient. No complications occurred. AVPs are excellent devices for embolizing shunt vessels in CHD patients. Here, we describe a simplified telescoping technique for AVP2 delivery to enter curvy target lesions gently and efficiently.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Feltes Timothy F, Bacha Emile, Beekman Robert H, Cheatham John P, Feinstein Jeffrey A, Gomes Antoinette S, Hijazi Ziyad M, Ing Frank F, Michael de Moor W, Morrow Robert, Mullins Charles E, Taubert Kathryn A, Zahn Evan M (2011) Indications for cardiac catheterization and intervention in pediatric cardiac disease: a scientific statement from the American Heart Association. Circulation 123(22):2607–2652CrossRef Feltes Timothy F, Bacha Emile, Beekman Robert H, Cheatham John P, Feinstein Jeffrey A, Gomes Antoinette S, Hijazi Ziyad M, Ing Frank F, Michael de Moor W, Morrow Robert, Mullins Charles E, Taubert Kathryn A, Zahn Evan M (2011) Indications for cardiac catheterization and intervention in pediatric cardiac disease: a scientific statement from the American Heart Association. Circulation 123(22):2607–2652CrossRef
2.
Zurück zum Zitat Porstmann W, Wierny L, Warnke H (1967) Closure of persistent ductus arteriosus without thoracotomy. Ger Med Mon 12(6):259–261PubMed Porstmann W, Wierny L, Warnke H (1967) Closure of persistent ductus arteriosus without thoracotomy. Ger Med Mon 12(6):259–261PubMed
3.
Zurück zum Zitat Schwartz M, Glatz AC, Rome JJ, Gillespie MJ (2010) The Amplatzer vascular plug and Amplatzer vascular plug II for vascular occlusion procedures in 50 patients with congenital cardiovascular disease. Catheter Cardiovasc Interv 76(3):411–417CrossRefPubMed Schwartz M, Glatz AC, Rome JJ, Gillespie MJ (2010) The Amplatzer vascular plug and Amplatzer vascular plug II for vascular occlusion procedures in 50 patients with congenital cardiovascular disease. Catheter Cardiovasc Interv 76(3):411–417CrossRefPubMed
4.
Zurück zum Zitat Wiegand G, Sieverding L, Bocksch W, Hofbeck M (2013) Transcatheter closure of abnormal vessels and arteriovenous fistulas with the Amplatzer vascular plug 4 in patients with congenital heart disease. Pediatr Cardiol 34(7):1668–1673CrossRefPubMed Wiegand G, Sieverding L, Bocksch W, Hofbeck M (2013) Transcatheter closure of abnormal vessels and arteriovenous fistulas with the Amplatzer vascular plug 4 in patients with congenital heart disease. Pediatr Cardiol 34(7):1668–1673CrossRefPubMed
5.
Zurück zum Zitat Brown SC, Boshoff DE, Eyskens B, Mertens L, Gewillig M (2009) Use of a microcatheter in a telescopic system to reach difficult targets in complex congenital heart disease. Catheter Cardiovasc Interv 73(5):676–681CrossRefPubMed Brown SC, Boshoff DE, Eyskens B, Mertens L, Gewillig M (2009) Use of a microcatheter in a telescopic system to reach difficult targets in complex congenital heart disease. Catheter Cardiovasc Interv 73(5):676–681CrossRefPubMed
6.
Zurück zum Zitat Krichenko A, Benson LN, Burrows P, Moes CA, McLaughlin P, Freedom RM (1989) Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol 63(12):877–880CrossRefPubMed Krichenko A, Benson LN, Burrows P, Moes CA, McLaughlin P, Freedom RM (1989) Angiographic classification of the isolated, persistently patent ductus arteriosus and implications for percutaneous catheter occlusion. Am J Cardiol 63(12):877–880CrossRefPubMed
7.
Zurück zum Zitat Wang W, Li H, Tam MD, Zhou D, Wang DX, Spain J (2012) The Amplatzer vascular plug: a review of the device and its clinical applications. Cardiovasc Interv Radiol 35(4):725–740CrossRef Wang W, Li H, Tam MD, Zhou D, Wang DX, Spain J (2012) The Amplatzer vascular plug: a review of the device and its clinical applications. Cardiovasc Interv Radiol 35(4):725–740CrossRef
9.
Zurück zum Zitat Barwad P, Ramakrishnan S, Kothari SS, Saxena A, Gupta SK, Juneja R, Gulati GS, Jagia P, Sharma S (2013) Amplatzer vascular plugs in congenital cardiovascular malformations. Ann Pediatr Cardiol 6(2):132–140CrossRefPubMedPubMedCentral Barwad P, Ramakrishnan S, Kothari SS, Saxena A, Gupta SK, Juneja R, Gulati GS, Jagia P, Sharma S (2013) Amplatzer vascular plugs in congenital cardiovascular malformations. Ann Pediatr Cardiol 6(2):132–140CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Fischer G, Apostolopoulou SC, Rammos S, Kiaffas M, Kramer HH (2007) Transcatheter closure of coronary arterial fistulas using the new Amplatzer vascular plug. Cardiol Young 17(3):283–287CrossRefPubMed Fischer G, Apostolopoulou SC, Rammos S, Kiaffas M, Kramer HH (2007) Transcatheter closure of coronary arterial fistulas using the new Amplatzer vascular plug. Cardiol Young 17(3):283–287CrossRefPubMed
11.
Zurück zum Zitat Hill SL, Hijazi ZM, Hellenbrand WE, Cheatham JP (2006) Evaluation of the Amplatzer vascular plug for embolization of peripheral vascular malformations associated with congenital heart disease. Catheter Cardiovasc Interv 67(1):113–119CrossRefPubMed Hill SL, Hijazi ZM, Hellenbrand WE, Cheatham JP (2006) Evaluation of the Amplatzer vascular plug for embolization of peripheral vascular malformations associated with congenital heart disease. Catheter Cardiovasc Interv 67(1):113–119CrossRefPubMed
12.
Zurück zum Zitat Butera G, Hassan E, MacDonald ST (2012) Telescopic catheter-in-long sheath and parallel to a stiff guide wire technique for complex pulmonary artery anatomy. Catheter Cardiovasc Interv 80(4):673–677CrossRefPubMed Butera G, Hassan E, MacDonald ST (2012) Telescopic catheter-in-long sheath and parallel to a stiff guide wire technique for complex pulmonary artery anatomy. Catheter Cardiovasc Interv 80(4):673–677CrossRefPubMed
13.
Zurück zum Zitat Zhu X, Tam MD, Pierce G, McLennan G, Sands MJ, Lieber MS, Wang W (2011) Utility of the Amplatzer vascular plug in splenic artery embolization: a comparison study with conventional coil technique. Cardiovasc Interv Radiol 34(3):522–531CrossRef Zhu X, Tam MD, Pierce G, McLennan G, Sands MJ, Lieber MS, Wang W (2011) Utility of the Amplatzer vascular plug in splenic artery embolization: a comparison study with conventional coil technique. Cardiovasc Interv Radiol 34(3):522–531CrossRef
14.
Zurück zum Zitat De Santis A, Cifarelli A, Violini R (2010) Transcatheter closure of coronary artery fistula using the new Amplatzer vascular plug and a telescoping catheter technique. J Cardiovasc Med (Hagerstown) 11(8):605–609CrossRef De Santis A, Cifarelli A, Violini R (2010) Transcatheter closure of coronary artery fistula using the new Amplatzer vascular plug and a telescoping catheter technique. J Cardiovasc Med (Hagerstown) 11(8):605–609CrossRef
15.
Zurück zum Zitat Lange M, Bultel H, Weglage H, Loffeld P, Wichter T (2016) Using a steerable guiding sheath to implant an AMPLATZERAmulet Left Atrial Appendage Occluder for prevention of thromboembolic stroke. Int J Cardiol 221:466–467CrossRefPubMed Lange M, Bultel H, Weglage H, Loffeld P, Wichter T (2016) Using a steerable guiding sheath to implant an AMPLATZERAmulet Left Atrial Appendage Occluder for prevention of thromboembolic stroke. Int J Cardiol 221:466–467CrossRefPubMed
16.
Zurück zum Zitat Jambon E, Petitpierre F, Brizzi V, Dubuisson V, Le Bras Y, Grenier N, Cornelis F (2017) Proximal occlusion of medium-sized vessels with the penumbra occlusion device: a study of safety and efficacy. Cardiovasc Interv Radiol 40(2):210–215CrossRef Jambon E, Petitpierre F, Brizzi V, Dubuisson V, Le Bras Y, Grenier N, Cornelis F (2017) Proximal occlusion of medium-sized vessels with the penumbra occlusion device: a study of safety and efficacy. Cardiovasc Interv Radiol 40(2):210–215CrossRef
17.
Zurück zum Zitat Yu PS, Yu SC, Ng CT, Kwok MW, Chow SC, Ho JY, Underwood MJ, Wong RH (2016) Coil embolization of diverticulum of Kommerell: a targeted hybrid endovascular technique. Ann Thorac Surg 101(5):e139–e141CrossRefPubMed Yu PS, Yu SC, Ng CT, Kwok MW, Chow SC, Ho JY, Underwood MJ, Wong RH (2016) Coil embolization of diverticulum of Kommerell: a targeted hybrid endovascular technique. Ann Thorac Surg 101(5):e139–e141CrossRefPubMed
18.
Zurück zum Zitat Fanning NF, Berentei Z, Brennan PR, Thornton J (2007) HydroCoil as an adjuvant to bare platinum coil treatment of 100 cerebral aneurysms. Neuroradiology 49(2):139–148CrossRefPubMed Fanning NF, Berentei Z, Brennan PR, Thornton J (2007) HydroCoil as an adjuvant to bare platinum coil treatment of 100 cerebral aneurysms. Neuroradiology 49(2):139–148CrossRefPubMed
19.
Zurück zum Zitat Conrad MB, Ishaque BM, Surman AM, Kerlan RK Jr, Hope MD, Dickey MA, Hetts SW, Wilson MW (2015) Intraprocedural safety and technical success of the MVP micro vascular plug for embolization of pulmonary arteriovenous malformations. J Vasc Interv Radiol 26(11):1735–1739CrossRefPubMed Conrad MB, Ishaque BM, Surman AM, Kerlan RK Jr, Hope MD, Dickey MA, Hetts SW, Wilson MW (2015) Intraprocedural safety and technical success of the MVP micro vascular plug for embolization of pulmonary arteriovenous malformations. J Vasc Interv Radiol 26(11):1735–1739CrossRefPubMed
20.
Zurück zum Zitat Boudjemline Y (2017) Covidien micro vascular plug in congenital heart diseases and vascular anomalies: a new kid on the block for premature babies and older patients. Catheter Cardiovasc Interv 89(1):114–119CrossRefPubMed Boudjemline Y (2017) Covidien micro vascular plug in congenital heart diseases and vascular anomalies: a new kid on the block for premature babies and older patients. Catheter Cardiovasc Interv 89(1):114–119CrossRefPubMed
21.
Zurück zum Zitat Sathanandam S, Justino H, Waller BR 3rd, Gowda ST, Radtke W, Qureshi AM (2017) The medtronic micro vascular plug for vascular embolization in children with congenital heart diseases. J Interv Cardiol 30(2):177–184CrossRefPubMed Sathanandam S, Justino H, Waller BR 3rd, Gowda ST, Radtke W, Qureshi AM (2017) The medtronic micro vascular plug for vascular embolization in children with congenital heart diseases. J Interv Cardiol 30(2):177–184CrossRefPubMed
22.
Zurück zum Zitat MacDonald ST, Carminati M, Butera G (2011) Initial experience with the Amplatzer vascular plug IV in congenital heart disease: coronary artery fistula and aortopulmonary collateral artery embolization. J Invasive Cardiol 23(3):120–124PubMed MacDonald ST, Carminati M, Butera G (2011) Initial experience with the Amplatzer vascular plug IV in congenital heart disease: coronary artery fistula and aortopulmonary collateral artery embolization. J Invasive Cardiol 23(3):120–124PubMed
23.
Zurück zum Zitat Adelmann R, Windfuhr A, Bennink G, Emmel M, Sreeram N (2011) Extended applications of the Amplatzer vascular plug IV in infants. Cardiol Young 21(2):178–181CrossRefPubMed Adelmann R, Windfuhr A, Bennink G, Emmel M, Sreeram N (2011) Extended applications of the Amplatzer vascular plug IV in infants. Cardiol Young 21(2):178–181CrossRefPubMed
24.
Zurück zum Zitat Delaney JW, Fletcher SE (2013) Patent ductus arteriosus closure using the Amplatzer(R) vascular plug II for all anatomic variants. Catheter Cardiovasc Interv 81(5):820–824CrossRefPubMed Delaney JW, Fletcher SE (2013) Patent ductus arteriosus closure using the Amplatzer(R) vascular plug II for all anatomic variants. Catheter Cardiovasc Interv 81(5):820–824CrossRefPubMed
25.
Zurück zum Zitat Zahn EM, Nevin P, Simmons C, Garg R (2015) A novel technique for transcatheter patent ductus arteriosus closure in extremely preterm infants using commercially available technology. Catheter Cardiovasc Interv 85(2):240–248CrossRefPubMed Zahn EM, Nevin P, Simmons C, Garg R (2015) A novel technique for transcatheter patent ductus arteriosus closure in extremely preterm infants using commercially available technology. Catheter Cardiovasc Interv 85(2):240–248CrossRefPubMed
26.
Zurück zum Zitat Baruteau AE, Hascoet S, Baruteau J, Boudjemline Y, Lambert V, Angel CY, Belli E, Petit J, Pass R (2014) Transcatheter closure of patent ductus arteriosus: past, present and future. Arch Cardiovasc Dis 107(2):122–132CrossRefPubMed Baruteau AE, Hascoet S, Baruteau J, Boudjemline Y, Lambert V, Angel CY, Belli E, Petit J, Pass R (2014) Transcatheter closure of patent ductus arteriosus: past, present and future. Arch Cardiovasc Dis 107(2):122–132CrossRefPubMed
27.
Zurück zum Zitat Philip R, Waller BR 3rd, Agrawal V, Wright D, Arevalo A, Zurakowski D, Sathanandam S (2016) Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device. Catheter Cardiovasc Interv 87(2):310–317CrossRefPubMed Philip R, Waller BR 3rd, Agrawal V, Wright D, Arevalo A, Zurakowski D, Sathanandam S (2016) Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device. Catheter Cardiovasc Interv 87(2):310–317CrossRefPubMed
28.
Zurück zum Zitat Garay FJ, Aguirre D, Cardenas L, Springmuller D, Heusser F (2015) Use of the amplatzer vascular plug II device to occlude different types of patent ductus arteriosus in pediatric patients. J Interv Cardiol 28(2):198–204CrossRefPubMed Garay FJ, Aguirre D, Cardenas L, Springmuller D, Heusser F (2015) Use of the amplatzer vascular plug II device to occlude different types of patent ductus arteriosus in pediatric patients. J Interv Cardiol 28(2):198–204CrossRefPubMed
29.
Zurück zum Zitat Baruteau AE, Lambert V, Riou JY, Angel CY, Belli E, Petit J (2015) Closure of tubular patent ductus arteriosus with the Amplatzer vascular plug IV: feasibility and safety. World J Pediatr Congenit Heart Surg 6(1):39–45CrossRefPubMed Baruteau AE, Lambert V, Riou JY, Angel CY, Belli E, Petit J (2015) Closure of tubular patent ductus arteriosus with the Amplatzer vascular plug IV: feasibility and safety. World J Pediatr Congenit Heart Surg 6(1):39–45CrossRefPubMed
Metadaten
Titel
Collateral closure in congenital heart defects with Amplatzer vascular plugs: single-center experience and a simplified delivery technique for exceptional cases
verfasst von
Rouven Kubicki
Brigitte Stiller
Johanna Hummel
Rene Höhn
Thilo Fleck
Jochen Grohmann
Publikationsdatum
24.07.2018
Verlag
Springer Japan
Erschienen in
Heart and Vessels / Ausgabe 1/2019
Print ISSN: 0910-8327
Elektronische ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-018-1232-3

Weitere Artikel der Ausgabe 1/2019

Heart and Vessels 1/2019 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.