Skip to main content
Erschienen in: International Urogynecology Journal 7/2018

12.03.2018 | Commentary

Commentary on “Comparison of adjustable continence therapy periurethral balloons and artificial urinary sphincter in female patients with stress urinary incontinence due to intrinsic sphincter deficiency”

verfasst von: Abdelmageed Abdelrahman

Erschienen in: International Urogynecology Journal | Ausgabe 7/2018

Einloggen, um Zugang zu erhalten

Excerpt

This was a single-centre retrospective study that compared outcomes of Adjustable Continence Therapy (ACT) periurethral balloons with the artificial urinary sphincter AMS 800 in the treatment of stress urinary incontinence (SUI) due to sphincter deficiency in women. The inclusion criterion was all women who underwent surgical treatment for SUI due to intrinsic sphincter deficiency from 2007 to 2017. Intrinsic sphincter deficiency was defined as the combination of a low urethral closure pressure (<40 cm H20), loss of urethral mobility and a negative Marshall/Bonney test (urine leakage on straining or coughing not corrected by urethral support). The AMS 800 was considered as the standard treatment in these patients during the study period. Of note, the ACT balloons became available in this particular centre in 2011 and was used in the following cases: moderate incontinence (subjectively defined as pad test <200 g/24 h), patients >80 years and/or morbidly obese and/or lacking manual dexterity limiting the ability to operate the sphincter pump and/or with a history of previous pelvic irradiation therapy and/or who refused implantation of an artificial urinary sphincter. The primary endpoint was the functional outcome categorised as cure (complete continence, i.e. no pads used), improved (decrease in number of pads per day or in urine leakage assessed through pad test) or failure (no decrease in number of pads per day or urine leakage assessed through pad test). In this study, 25 patients underwent ACT implantation and 36 had AMS 800 implantation. Of note, patients in the latter group were younger, had less comorbidity and a higher rate of intraoperative complications; however, rates of postoperative complications were similar between groups. Overall, the authors concluded that results were in favour of the AMS 800 group. …
Metadaten
Titel
Commentary on “Comparison of adjustable continence therapy periurethral balloons and artificial urinary sphincter in female patients with stress urinary incontinence due to intrinsic sphincter deficiency”
verfasst von
Abdelmageed Abdelrahman
Publikationsdatum
12.03.2018
Verlag
Springer London
Erschienen in
International Urogynecology Journal / Ausgabe 7/2018
Print ISSN: 0937-3462
Elektronische ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-018-3607-5

Weitere Artikel der Ausgabe 7/2018

International Urogynecology Journal 7/2018 Zur Ausgabe

Update Gynäkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.