Skip to main content
Erschienen in: European Journal of Orthopaedic Surgery & Traumatology 1/2017

06.09.2016 | Original Article • KNEE - ARTHOPLASTY

Comparing Steri-Strip and surgical staple wound closures after primary total knee arthroplasties

verfasst von: Satoshi Takayama, Takeshi Yamamoto, Chiduru Tsuchiya, Hideo Noguchi, Junko Sato, Yoshinori Ishii

Erschienen in: European Journal of Orthopaedic Surgery & Traumatology | Ausgabe 1/2017

Einloggen, um Zugang zu erhalten

Abstract

Background

Steri-Strips (3M, Two Harbors, MN, USA) have recently been employed for skin closures after orthopedic surgeries. Here we compare the performance of Steri-Strips and skin staples for wound closure after primary total knee arthroplasties (TKAs).

Methods

A total of 76 consecutive osteoarthritic knees (71 patients) that underwent a primary TKA at our facility were included in this study. Thirty-eight knees received Steri-Strips for wound closure and were evaluated prospectively. The other 38 knees were closed with skin staples (Staple group) and evaluated retrospectively.

Results

No deep or superficial infections developed in this series. Although Steri-Strips detached from three knees during the 10-day postoperative period, no dehiscence was observed. Thirteen knees developed blisters around the surgical incision in the Steri-Strip group compared with five knees in the Staple group. The average operative time for the Steri-Strip group was 60.6 min (SD 7.3) compared with 54.1 min (SD 6.9) in the Staple group. There were significant differences in operative time (p < 0.001) and tourniquet time (p < 0.001) between the two groups. The average time until patients were permitted to start showering was significantly shorter in the Steri-Strip group (p = 0.0496). The material cost for Steri-Strips was approximately $3.00 USD for one operation compared with $26 USD for skin staplers.

Conclusions

Wound closure with Steri-Strips after a TKA does not require postoperative material removal and may have improved safety, comfort, cosmesis and cost-effectiveness compared with traditional skin closures.

Level of evidence

Level II, Prognostic study.
Literatur
1.
Zurück zum Zitat Kawakami H, Setoyama T, Uchiyama S, Tominaga H, Tsuneyoshi Y, Komiya S (2012) Usefulness of Steri-Strips® and Dermabond® 203 in orthopedic surgery. Orthop Traumatol 61(3):463–467 (in Japanese) CrossRef Kawakami H, Setoyama T, Uchiyama S, Tominaga H, Tsuneyoshi Y, Komiya S (2012) Usefulness of Steri-Strips® and Dermabond® 203 in orthopedic surgery. Orthop Traumatol 61(3):463–467 (in Japanese) CrossRef
2.
Zurück zum Zitat Khan RJ, Fick D, Yao F, Tang K, Hurworth M, Nivbrant B, Wood D (2006) A comparison of three methods of wound closure following arthroplasty: a prospective, randomised, controlled trial. J Bone Joint Surg Br 88(2):238–242CrossRefPubMed Khan RJ, Fick D, Yao F, Tang K, Hurworth M, Nivbrant B, Wood D (2006) A comparison of three methods of wound closure following arthroplasty: a prospective, randomised, controlled trial. J Bone Joint Surg Br 88(2):238–242CrossRefPubMed
3.
Zurück zum Zitat Smith TO, Sexton D, Mann C, Donell S (2010) Sutures versus staples for skin closure in orthopaedic surgery: meta-analysis. BMJ 16(340):c1199CrossRef Smith TO, Sexton D, Mann C, Donell S (2010) Sutures versus staples for skin closure in orthopaedic surgery: meta-analysis. BMJ 16(340):c1199CrossRef
4.
Zurück zum Zitat Newman JT, Morgan SJ, Resende GV, Williams AE, Hammerberg EM, Dayton MR (2011) Modality of wound closure after total knee replacement: are staples as safe as sutures? A retrospective study of 181 patients. Patient Saf Surg 5(1):26CrossRefPubMedPubMedCentral Newman JT, Morgan SJ, Resende GV, Williams AE, Hammerberg EM, Dayton MR (2011) Modality of wound closure after total knee replacement: are staples as safe as sutures? A retrospective study of 181 patients. Patient Saf Surg 5(1):26CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Slade Shantz JA, Vernon J, Morshed S, Leiter J, Stranges G (2013) Sutures versus staples for wound closure in orthopaedic surgery: a pilot randomized controlled trial. Patient Saf Surg 7(1):6CrossRefPubMedPubMedCentral Slade Shantz JA, Vernon J, Morshed S, Leiter J, Stranges G (2013) Sutures versus staples for wound closure in orthopaedic surgery: a pilot randomized controlled trial. Patient Saf Surg 7(1):6CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Shetty AA, Kumar VS, Morgan-Hough C, Georgeu GA, James KD, Nicholl JE (2004) Comparing wound complication rates following closure of hip wounds with metallic skin staples or subcuticular vicryl suture: a prospective randomised trial. J Orthop Surg (Hong Kong) 12:191–193CrossRef Shetty AA, Kumar VS, Morgan-Hough C, Georgeu GA, James KD, Nicholl JE (2004) Comparing wound complication rates following closure of hip wounds with metallic skin staples or subcuticular vicryl suture: a prospective randomised trial. J Orthop Surg (Hong Kong) 12:191–193CrossRef
7.
Zurück zum Zitat Masuda H, Kuroki H, Hamanaka H, Inomata N, Higuchi S, Kawano K, Lee D, Chosa E (2012) Use of 2-Octyl cyanoacrylate (Dermabond HV) for skin closure in cervical laminoplasty. Orthop Traumatol 61(3):506–508 (in Japanese) CrossRef Masuda H, Kuroki H, Hamanaka H, Inomata N, Higuchi S, Kawano K, Lee D, Chosa E (2012) Use of 2-Octyl cyanoacrylate (Dermabond HV) for skin closure in cervical laminoplasty. Orthop Traumatol 61(3):506–508 (in Japanese) CrossRef
8.
Zurück zum Zitat Lazar HL, McCann J, Fitzgerald CA, Cabral HJ (2011) Adhesive strips versus subcuticular suture for mediansternotomy wound closure. J Card Surg 26(4):344–347CrossRefPubMed Lazar HL, McCann J, Fitzgerald CA, Cabral HJ (2011) Adhesive strips versus subcuticular suture for mediansternotomy wound closure. J Card Surg 26(4):344–347CrossRefPubMed
9.
Zurück zum Zitat van de Gevel DF, Hamad MA, Elenbaas TW, Ostertag JU, Schönberger JP (2010) Is the use of Steri-StripTM S for wound closure after coronary artery bypass grafting better than intracuticular suture? Interact CardioVasc Thorac Surg 10(4):561–564CrossRefPubMed van de Gevel DF, Hamad MA, Elenbaas TW, Ostertag JU, Schönberger JP (2010) Is the use of Steri-StripTM S for wound closure after coronary artery bypass grafting better than intracuticular suture? Interact CardioVasc Thorac Surg 10(4):561–564CrossRefPubMed
10.
Zurück zum Zitat Romero P, Frongia G, Wingerter S, Holland-Cunz S (2011) Prospective, randomized, controlled trial comparing a tissue adhesive (Dermabond™) with adhesive strips (Steri-Strips™) for the closure of laparoscopic trocar wounds in children. Eur J Pediatr Surg 21(3):159–162CrossRefPubMed Romero P, Frongia G, Wingerter S, Holland-Cunz S (2011) Prospective, randomized, controlled trial comparing a tissue adhesive (Dermabond™) with adhesive strips (Steri-Strips™) for the closure of laparoscopic trocar wounds in children. Eur J Pediatr Surg 21(3):159–162CrossRefPubMed
11.
Zurück zum Zitat Stavrou P, Symeonidis PD, Iselin LD, Dracopoulos G (2012) Sutures versus sterile strips for closure of ankle arthroscopy portals: prospective crossover trial. Foot Ankle Int 33(3):190–195CrossRefPubMed Stavrou P, Symeonidis PD, Iselin LD, Dracopoulos G (2012) Sutures versus sterile strips for closure of ankle arthroscopy portals: prospective crossover trial. Foot Ankle Int 33(3):190–195CrossRefPubMed
12.
Zurück zum Zitat Grottkau BE, Rebello G, Merlin G, Winograd JM (2010) Coaptive film versus subcuticular suture: comparing skin closure time after posterior spinal instrumented fusion in pediatric patients with spinal deformity. Spine 35(23):2027–2029CrossRefPubMed Grottkau BE, Rebello G, Merlin G, Winograd JM (2010) Coaptive film versus subcuticular suture: comparing skin closure time after posterior spinal instrumented fusion in pediatric patients with spinal deformity. Spine 35(23):2027–2029CrossRefPubMed
13.
Zurück zum Zitat Halawi MJ (2015) Fracture blisters after primary total knee arthroplasty. Am J Orthop (Belle Mead NJ) 44(8):E291–E293 Halawi MJ (2015) Fracture blisters after primary total knee arthroplasty. Am J Orthop (Belle Mead NJ) 44(8):E291–E293
14.
Zurück zum Zitat Koval KJ, Egol KA, Polatsch DB, Baskies MA, Homman JP, Hiebert RN (2003) Tape blisters following hip surgery, a prospective, randomized study of two types of tape. J Bone Joint Surg Am 85(10):1884–1887CrossRefPubMed Koval KJ, Egol KA, Polatsch DB, Baskies MA, Homman JP, Hiebert RN (2003) Tape blisters following hip surgery, a prospective, randomized study of two types of tape. J Bone Joint Surg Am 85(10):1884–1887CrossRefPubMed
15.
Zurück zum Zitat Anuar Ramdhan I, Zulmi W, Hidayah A, Kamel M, Fadhil M, Anwar Hau M (2013) Comparative study between coaptive film versus suture for wound closure after long bone fracture fixation. Malays Orthop J 7(1):52–55PubMedPubMedCentral Anuar Ramdhan I, Zulmi W, Hidayah A, Kamel M, Fadhil M, Anwar Hau M (2013) Comparative study between coaptive film versus suture for wound closure after long bone fracture fixation. Malays Orthop J 7(1):52–55PubMedPubMedCentral
16.
Zurück zum Zitat Mangram AJ, Horan TC, Pearson ML, Silver LC, Jarvis WR (1999) The hospital infection control practices advisory committee. Guideline for prevention of surgical site infection, 1999. Infect Control Hosp Epidemiol 20(4):250–278CrossRefPubMed Mangram AJ, Horan TC, Pearson ML, Silver LC, Jarvis WR (1999) The hospital infection control practices advisory committee. Guideline for prevention of surgical site infection, 1999. Infect Control Hosp Epidemiol 20(4):250–278CrossRefPubMed
17.
Zurück zum Zitat Hsieh PY, Chen KY, Chen HY, Sheng WH, Chang CH, Wang CL, Chiag PY, Chen HP, Shiao CW, Lee PC, Tai HC, Chien HF, Yu PJ, Lin BR, Lai YH, Chen JS, Lai HS (2016) Postoperative showering for clean and clean-contaminated wounds: a prospective, randomized controlled trial. Ann Surg 263(5):931–936CrossRefPubMed Hsieh PY, Chen KY, Chen HY, Sheng WH, Chang CH, Wang CL, Chiag PY, Chen HP, Shiao CW, Lee PC, Tai HC, Chien HF, Yu PJ, Lin BR, Lai YH, Chen JS, Lai HS (2016) Postoperative showering for clean and clean-contaminated wounds: a prospective, randomized controlled trial. Ann Surg 263(5):931–936CrossRefPubMed
Metadaten
Titel
Comparing Steri-Strip and surgical staple wound closures after primary total knee arthroplasties
verfasst von
Satoshi Takayama
Takeshi Yamamoto
Chiduru Tsuchiya
Hideo Noguchi
Junko Sato
Yoshinori Ishii
Publikationsdatum
06.09.2016
Verlag
Springer Paris
Erschienen in
European Journal of Orthopaedic Surgery & Traumatology / Ausgabe 1/2017
Print ISSN: 1633-8065
Elektronische ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-016-1848-x

Weitere Artikel der Ausgabe 1/2017

European Journal of Orthopaedic Surgery & Traumatology 1/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.