04.09.2015 | Original Article | Ausgabe 9/2016

Heart and Vessels 9/2016

Comparison between drug-coated balloon angioplasty and second-generation drug-eluting stent placement for the treatment of in-stent restenosis after drug-eluting stent implantation

Zeitschrift:
Heart and Vessels > Ausgabe 9/2016
Autoren:
In Sook Kang, Islam Shehata, Dong-Ho Shin, Jung-Sun Kim, Byeong-Keuk Kim, Young-Guk Ko, Donghoon Choi, Yangsoo Jang, Myeong-Ki Hong
Wichtige Hinweise
I. S. Kang and I. Shehata contributed equally to this paper.

Abstract

Even though drug-coated balloon (DCB) angioplasty has emerged as a treatment option for drug-eluting stent in-stent restenosis (DES–ISR), the most effective treatment strategy for DES–ISR is still under debate. Therefore, we compared long-term clinical outcomes following DCB treatment of DES–ISR with those following 2nd-generation drug-eluting stent (DES) treatment. We identified 248 DES–ISR lesions in 238 patients that were treated with either 2nd-generation DES implantation (n = 56) or DCB angioplasty (n = 192). We compared the incidences of major adverse cardiac events (MACEs) in the two groups during the 2-year period following treatment. MACE was defined as cardiac death, non-fatal myocardial infarction, or target-vessel revascularization. The percentage of patients with diabetes and the mean age of patients in the DCB group were greater than in the DES group. The DCB group also had a smaller reference vessel diameter. The DES group had a larger post-intervention minimal luminal diameter. We found no significant difference in the MACE rate between the two groups during the 2 years following treatment (11.0 % in the DCB group vs. 8.9 % in the DES group, p = 0.660). Reference segment diameter was the only independent predictive factor for MACE in the post-treatment period (hazard ratio 0.35, 95 % confidence interval: 0.15–0.82, p = 0.016). Clinical efficacy of DCB angioplasty for treatment of DES–ISR was comparable to that of 2nd-generation DES implantation as measured by the rate of MACEs in the two groups. Reference segment diameter was the only statistically significant independent predictor for MACE in the 2-year period following treatment.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 9/2016

Heart and Vessels 9/2016 Zur Ausgabe

Neu im Fachgebiet Kardiologie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Kardiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise