Skip to main content
Erschienen in: Magnetic Resonance Materials in Physics, Biology and Medicine 4/2020

28.11.2019 | Research Article

Comparison between synthetic and conventional magnetic resonance imaging in patients with multiple sclerosis and controls

verfasst von: Francesca Di Giuliano, Silvia Minosse, Eliseo Picchi, Girolama Alessandra Marfia, Valerio Da Ros, Massimo Muto, Mario Muto, Chiara Adriana Pistolese, Andrea Laghi, Francesco Garaci, Roberto Floris

Erschienen in: Magnetic Resonance Materials in Physics, Biology and Medicine | Ausgabe 4/2020

Einloggen, um Zugang zu erhalten

Abstract

Objectives

Synthetic magnetic resonance imaging (SyMRI) allows to obtain different weighted-images using the multiple-dynamic multiple-echo sequence lasting 6 min. The aim is to compare quantitatively and qualitatively synthetic- and conventional MRI in patients with multiple sclerosis (MS) and controls assessing the contrast (C), the signal to noise ratio (SNR), and the contrast to noise ratio (CNR). We evaluated the lesion count and lesion-to-white matter contrast (\({\text{C}}_{{\text{l } - \text{ WM}}} {)}\) in the MS patients.

Methods and methods

51 patients underwent synthetic- and conventional MRI. Qualitative analysis was evaluated by assigning scores to all synthetic- and conventional MRI sequences by two neuroradiologists. Lesions were counted in MS patients both in the conventional- and synthetic T2-FLAIR. Regions of interest were placed in the cerebrospinal fluid, in the white- and grey matter. For the sequences were evaluated: C, CNR, and SNR.

Results

Synthetic T2-FLAIR images are qualitatively inferior. C and CNR were significantly higher in synthetic T1W and T2W images compared to conventional images, but not for T2-FLAIR. The SNR value was always lower in synthetic images than in conventional ones.

Conclusions

SyMRI can be used in clinical practice because it has a similar diagnostic accuracy which reduces the scanning time compared to the conventional one. However, synthetic T2-FLAIR images need to be improved.
Literatur
2.
Zurück zum Zitat Riederer SJ, Lee JN, Farzaneh F, Wang HZ, Wright RC (1986) Magnetic resonance image synthesis. Clinical implementation. Acta Radiol Suppl 369:466–468PubMed Riederer SJ, Lee JN, Farzaneh F, Wang HZ, Wright RC (1986) Magnetic resonance image synthesis. Clinical implementation. Acta Radiol Suppl 369:466–468PubMed
14.
Zurück zum Zitat Bobman SA, Riederer SJ, Lee JN, Suddarth SA, Wang HZ, Drayer BP, MacFall JR (1985) Cerebral magnetic resonance image synthesis. Am J Neuroradiol 6:265–269PubMed Bobman SA, Riederer SJ, Lee JN, Suddarth SA, Wang HZ, Drayer BP, MacFall JR (1985) Cerebral magnetic resonance image synthesis. Am J Neuroradiol 6:265–269PubMed
15.
Zurück zum Zitat Granberg T, Uppman M, Hashim F, Cananau C, Nordin LE, Shams S, Berglund J, Forslin Y, Aspelin P, Fredrikson S, Kristoffersen-Wiberg M (2016) Clinical feasibility of synthetic MRI in multiple sclerosis: a diagnostic and volumetric validation study. Am J Neuroradiol. https://doi.org/10.3174/ajnr.A4665 CrossRefPubMed Granberg T, Uppman M, Hashim F, Cananau C, Nordin LE, Shams S, Berglund J, Forslin Y, Aspelin P, Fredrikson S, Kristoffersen-Wiberg M (2016) Clinical feasibility of synthetic MRI in multiple sclerosis: a diagnostic and volumetric validation study. Am J Neuroradiol. https://​doi.​org/​10.​3174/​ajnr.​A4665 CrossRefPubMed
18.
Zurück zum Zitat Tanenbaum LN, Tsiouris AJ, Johnson AN, Naidich TP, DeLano MC, Melhem ER, Quarterman P, Parameswaran SX, Shankaranarayanan A, Goyen M, Field AS (2017) Synthetic MRI for clinical neuroimaging: results of the magnetic resonance image compilation (MAGiC) prospective, multicenter, multireader trial. Am J Neuroradiol. https://doi.org/10.3174/ajnr.A5227 CrossRefPubMed Tanenbaum LN, Tsiouris AJ, Johnson AN, Naidich TP, DeLano MC, Melhem ER, Quarterman P, Parameswaran SX, Shankaranarayanan A, Goyen M, Field AS (2017) Synthetic MRI for clinical neuroimaging: results of the magnetic resonance image compilation (MAGiC) prospective, multicenter, multireader trial. Am J Neuroradiol. https://​doi.​org/​10.​3174/​ajnr.​A5227 CrossRefPubMed
21.
23.
Zurück zum Zitat Hagiwara A, Otsuka Y, Hori M, Tachibana Y, Yokoyama K, Fujita S, Andica C, Kamagata K, Irie R, Koshino S, Maekawa T, Chougar L, Wada A, Takemura MY, Hattori N, Aoki S (2019) Improving the quality of synthetic FLAIR images with deep learning using a conditional generative adversarial network for pixel-by-pixel image translation. Am J Neuroradiol. https://doi.org/10.3174/ajnr.A5927 CrossRefPubMed Hagiwara A, Otsuka Y, Hori M, Tachibana Y, Yokoyama K, Fujita S, Andica C, Kamagata K, Irie R, Koshino S, Maekawa T, Chougar L, Wada A, Takemura MY, Hattori N, Aoki S (2019) Improving the quality of synthetic FLAIR images with deep learning using a conditional generative adversarial network for pixel-by-pixel image translation. Am J Neuroradiol. https://​doi.​org/​10.​3174/​ajnr.​A5927 CrossRefPubMed
25.
Zurück zum Zitat Nelson F, Poonawalla AH, Hou P, Huang F, Wolinsky JS, Narayana PA (2007) Improved identification of intracortical lesions in multiple sclerosis with phase-sensitive inversion recovery in combination with fast double inversion recovery MR imaging. Am J Neuroradiol. https://doi.org/10.3174/ajnr.A0645 CrossRefPubMed Nelson F, Poonawalla AH, Hou P, Huang F, Wolinsky JS, Narayana PA (2007) Improved identification of intracortical lesions in multiple sclerosis with phase-sensitive inversion recovery in combination with fast double inversion recovery MR imaging. Am J Neuroradiol. https://​doi.​org/​10.​3174/​ajnr.​A0645 CrossRefPubMed
Metadaten
Titel
Comparison between synthetic and conventional magnetic resonance imaging in patients with multiple sclerosis and controls
verfasst von
Francesca Di Giuliano
Silvia Minosse
Eliseo Picchi
Girolama Alessandra Marfia
Valerio Da Ros
Massimo Muto
Mario Muto
Chiara Adriana Pistolese
Andrea Laghi
Francesco Garaci
Roberto Floris
Publikationsdatum
28.11.2019
Verlag
Springer International Publishing
Erschienen in
Magnetic Resonance Materials in Physics, Biology and Medicine / Ausgabe 4/2020
Print ISSN: 0968-5243
Elektronische ISSN: 1352-8661
DOI
https://doi.org/10.1007/s10334-019-00804-9

Weitere Artikel der Ausgabe 4/2020

Magnetic Resonance Materials in Physics, Biology and Medicine 4/2020 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.