Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 4/2019

16.08.2018 | Original Research

Comparison of ability of pulse pressure variation to predict fluid responsiveness in prone and supine position: an observational study

verfasst von: Achmet Ali, Taner Abdullah, Pulat Akin Sabanci, Lerzan Dogan, Mukadder Orhan-Sungur, Ibrahim Ozkan Akinci

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

We aimed to compare the ability of pulse pressure variation (PPV) to predict fluid responsiveness in prone and supine positions and investigate effect of body mass index (BMI), intraabdominal pressure (IAP) and static respiratory compliance (CS) on PPV. A total of 88 patients undergoing neurosurgery were included. After standardized anesthesia induction, patients’ PPV, stroke volume index (SVI), CS and IAP values were recorded in supine (T1) and prone (T2) positions and after fluid loading (T3). Also, PPV change percentage (PPVΔ%) between T2 and T1 times was calculated. Patients whose SVI increased more than 15% after the fluid loading were defined as volume responders. In 10 patients, PPVΔ% was ≤ − 20%. All of these patients had CST2 < 31 ml/cmH2O, seven had BMI > 30 kg/m2, and two had IAPT2 > 15 mmHg. In 16 patients, PPVΔ% was ≥ 20%. In these patients, 10 had CST2 < 31 ml/cmH2O, 10 had BMI > 30 kg/m2, and 12 had IAPT2 > 15 mmHg. Thirty-nine patients were volume responder. When all patients were examined for predicting fluid responsiveness, area under curves (AUC) of PPVT2 (0.790, 95%CI 0.690–0.870) was significantly lower than AUC of PPVT1 (0.937, 95%CI 0.878–0.997) with ROC analysis (p = 0.002). When patients whose CST2 was < 31 ml/cmH2O and whose BMI was > 30 kg/m2 were excluded from analysis separately, AUC of PPVT2 became similar to PPVT1. PPV in the prone can predict fluid responsiveness as good as PPV in the supine, only if BMI is < 30 kg/m2 and CS value at prone is > 31 ml/cmH2O.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Conway DH, Mayall R, Abdul-Latif MS, Gilligan S, Tackaberry C. Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery. Anaesthesia. 2002;57:845–9.CrossRefPubMed Conway DH, Mayall R, Abdul-Latif MS, Gilligan S, Tackaberry C. Randomised controlled trial investigating the influence of intravenous fluid titration using oesophageal Doppler monitoring during bowel surgery. Anaesthesia. 2002;57:845–9.CrossRefPubMed
2.
Zurück zum Zitat Venn R, Steele A, Richardson P, Poloniecki J, Grounds M, Newman P. Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth. 2002;88:65–71.CrossRefPubMed Venn R, Steele A, Richardson P, Poloniecki J, Grounds M, Newman P. Randomized controlled trial to investigate influence of the fluid challenge on duration of hospital stay and perioperative morbidity in patients with hip fractures. Br J Anaesth. 2002;88:65–71.CrossRefPubMed
3.
Zurück zum Zitat Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97:820–6.CrossRefPubMed Gan TJ, Soppitt A, Maroof M, et al. Goal-directed intraoperative fluid administration reduces length of hospital stay after major surgery. Anesthesiology. 2002;97:820–6.CrossRefPubMed
4.
Zurück zum Zitat Derichard A, Robin E, Tavernier B, et al. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery. Br J Anaesth. 2009;103:678–84.CrossRefPubMed Derichard A, Robin E, Tavernier B, et al. Automated pulse pressure and stroke volume variations from radial artery: evaluation during major abdominal surgery. Br J Anaesth. 2009;103:678–84.CrossRefPubMed
5.
Zurück zum Zitat Hofer CK, Muller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest. 2005;128:848–54.CrossRefPubMed Hofer CK, Muller SM, Furrer L, Klaghofer R, Genoni M, Zollinger A. Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting. Chest. 2005;128:848–54.CrossRefPubMed
6.
Zurück zum Zitat Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology. 2005;103:419–28.CrossRefPubMed Michard F. Changes in arterial pressure during mechanical ventilation. Anesthesiology. 2005;103:419–28.CrossRefPubMed
7.
Zurück zum Zitat Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth. 2010;104:407–13.CrossRefPubMed Biais M, Bernard O, Ha JC, Degryse C, Sztark F. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Br J Anaesth. 2010;104:407–13.CrossRefPubMed
8.
Zurück zum Zitat Dharmavaram S, Jellish WS, Nockels RP, et al. Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study. Spine (Phila Pa 1976). 2006;31:1388–93.CrossRef Dharmavaram S, Jellish WS, Nockels RP, et al. Effect of prone positioning systems on hemodynamic and cardiac function during lumbar spine surgery: an echocardiographic study. Spine (Phila Pa 1976). 2006;31:1388–93.CrossRef
9.
Zurück zum Zitat Yang SY, Shim JK, Song Y, Seo SJ, Kwak YL. Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position. Br J Anaesth. 2013;110:713–20.CrossRefPubMed Yang SY, Shim JK, Song Y, Seo SJ, Kwak YL. Validation of pulse pressure variation and corrected flow time as predictors of fluid responsiveness in patients in the prone position. Br J Anaesth. 2013;110:713–20.CrossRefPubMed
10.
Zurück zum Zitat Robinson JD, Lupkiewicz SM, Palenik L, Lopez LM, Ariet M. Determination of ideal body weight for drug dosage calculations. Am J Hosp Pharm. 1983;40:1016–9.PubMed Robinson JD, Lupkiewicz SM, Palenik L, Lopez LM, Ariet M. Determination of ideal body weight for drug dosage calculations. Am J Hosp Pharm. 1983;40:1016–9.PubMed
11.
12.
Zurück zum Zitat Yokoyama M, Ueda W, Hirakawa M, Yamamoto H. Hemodynamic effect of the prone position during anesthesia. Acta Anaesthesiol Scand. 1991;35:741–4.CrossRefPubMed Yokoyama M, Ueda W, Hirakawa M, Yamamoto H. Hemodynamic effect of the prone position during anesthesia. Acta Anaesthesiol Scand. 1991;35:741–4.CrossRefPubMed
13.
Zurück zum Zitat Marks R, Silverman R, Fernandez R, Candiotti KA, Fu E. Does the systolic pressure variation change in the prone position? J Clin Monit Comput. 2009;23:279–82.CrossRefPubMed Marks R, Silverman R, Fernandez R, Candiotti KA, Fu E. Does the systolic pressure variation change in the prone position? J Clin Monit Comput. 2009;23:279–82.CrossRefPubMed
14.
Zurück zum Zitat Takata M, Wise RA, Robotham JL. Effects of abdominal pressure on venous return: abdominal vascular zone conditions. J Appl Physiol (1985). 1990;69:1961–72.CrossRef Takata M, Wise RA, Robotham JL. Effects of abdominal pressure on venous return: abdominal vascular zone conditions. J Appl Physiol (1985). 1990;69:1961–72.CrossRef
15.
Zurück zum Zitat Kitano Y, Takata M, Sasaki N, Zhang Q, Yamamoto S, Miyasaka K. Influence of increased abdominal pressure on steady-state cardiac performance. J Appl Physiol. 1999;86:1651–6.CrossRefPubMed Kitano Y, Takata M, Sasaki N, Zhang Q, Yamamoto S, Miyasaka K. Influence of increased abdominal pressure on steady-state cardiac performance. J Appl Physiol. 1999;86:1651–6.CrossRefPubMed
16.
Zurück zum Zitat Renner J, Gruenewald M, Quaden R, et al. Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model. Crit Care Med. 2009;37:650–8.CrossRefPubMed Renner J, Gruenewald M, Quaden R, et al. Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model. Crit Care Med. 2009;37:650–8.CrossRefPubMed
17.
Zurück zum Zitat Palmon SC, Kirsch JR, Depper JA, Toung TJ. The effect of the prone position on pulmonary mechanics is frame-dependent. Anesth Analg. 1998;87:1175–80.PubMed Palmon SC, Kirsch JR, Depper JA, Toung TJ. The effect of the prone position on pulmonary mechanics is frame-dependent. Anesth Analg. 1998;87:1175–80.PubMed
18.
Zurück zum Zitat Chiumello D, Cressoni M, Racagni M, Landi L, Li Bassi G, Polli F, Carlesso E, Gattinoni L. Effects of thoraco-pelvic supports during prone position in patients with acute lung injury/acute respiratory distress syndrome: a physiological study. Crit Care. 2006;10:R87.CrossRefPubMedPubMedCentral Chiumello D, Cressoni M, Racagni M, Landi L, Li Bassi G, Polli F, Carlesso E, Gattinoni L. Effects of thoraco-pelvic supports during prone position in patients with acute lung injury/acute respiratory distress syndrome: a physiological study. Crit Care. 2006;10:R87.CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Tournadre JP, Allaouchiche B, Cayrel V, Mathon L, Chassard D. Estimation of cardiac preload changes by systolic pressure variation in pigs undergoing pneumoperitoneum. Acta Anaesthesiol Scand. 2000;44:231–5.CrossRefPubMed Tournadre JP, Allaouchiche B, Cayrel V, Mathon L, Chassard D. Estimation of cardiac preload changes by systolic pressure variation in pigs undergoing pneumoperitoneum. Acta Anaesthesiol Scand. 2000;44:231–5.CrossRefPubMed
20.
Zurück zum Zitat Magder S. Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med. 2004;169:151–5.CrossRefPubMed Magder S. Clinical usefulness of respiratory variations in arterial pressure. Am J Respir Crit Care Med. 2004;169:151–5.CrossRefPubMed
21.
Zurück zum Zitat Teboul JL, Pinsky MR, Mercat A, et al. Estimating cardiac filling pressure in mechanically ventilated patients with hyperinflation. Crit Care Med. 2000;28:3631–6.CrossRefPubMed Teboul JL, Pinsky MR, Mercat A, et al. Estimating cardiac filling pressure in mechanically ventilated patients with hyperinflation. Crit Care Med. 2000;28:3631–6.CrossRefPubMed
22.
Zurück zum Zitat Jardin F, Genevray B, Brun-Ney D, Bourdarias JP. Influence of lung and chest wall compliances on transmission of airway pressure to the pleural space in critically ill patients. Chest. 1985;88:653–8.CrossRefPubMed Jardin F, Genevray B, Brun-Ney D, Bourdarias JP. Influence of lung and chest wall compliances on transmission of airway pressure to the pleural space in critically ill patients. Chest. 1985;88:653–8.CrossRefPubMed
23.
Zurück zum Zitat Monnet X, Bleibtreu A, Ferré A, et al. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med. 2012;40:152–7.CrossRefPubMed Monnet X, Bleibtreu A, Ferré A, et al. Passive leg-raising and end-expiratory occlusion tests perform better than pulse pressure variation in patients with low respiratory system compliance. Crit Care Med. 2012;40:152–7.CrossRefPubMed
Metadaten
Titel
Comparison of ability of pulse pressure variation to predict fluid responsiveness in prone and supine position: an observational study
verfasst von
Achmet Ali
Taner Abdullah
Pulat Akin Sabanci
Lerzan Dogan
Mukadder Orhan-Sungur
Ibrahim Ozkan Akinci
Publikationsdatum
16.08.2018
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2019
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-0195-3

Weitere Artikel der Ausgabe 4/2019

Journal of Clinical Monitoring and Computing 4/2019 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.