Skip to main content
Erschienen in: International Orthopaedics 7/2021

24.02.2021 | Original Paper

Comparison of “Bilboquet” device and locking plate for surgical treatment of proximal humerus complex fractures at two years follow-up

verfasst von: Yaniv Bismuth, Adeline Cambon-Binder, Alain Sautet, Levon Doursounian, Thomas Gregory, Claire Bastard

Erschienen in: International Orthopaedics | Ausgabe 7/2021

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Surgical treatment of three or four part fractures of the proximal humerus is complex. Different conservative techniques have been described. The main goal of this study was to compare the clinical and radiological outcomes of Bilboquet and locking plate at two year follow-up.

Methods

This is a retrospective, comparative study, with a continuous series of 41 patients. Bony fixation was achieved with a Bilboquet device in 22 patients or a locking plate in 19 patients. Patient evaluation included clinical data: shoulder range of motion, Constant–Murley shoulder score and DASH (Disabilities of the Arm, Shoulder and Hand) score, and imaging using standard shoulder X-rays.

Results

Of the 41 patients included, 1 patient was lost to follow-up in the locking plate group. At a mean follow-up of 24 months patients in Bilboquet group showed a Constant score higher than in locking plate (p = 0.02). Range of motion and DASH score were not significantly different between the two groups. avascular necrosis occured in three patients of Bilboquet group (14%) versus in two patients in the locking plate group (11%) (p > 0.5). Complication and reintervention rate were non-significantly higher in the locking plate group than in the Bilboquet group (37 vs 14%).

Conclusion

Bilboquet and locking plate give good functional outcomes in complex proximal humerus fractures. However, the Bilboquet device appears to provide better functional results than locking plate at mid-term follow-up.
Literatur
2.
Zurück zum Zitat Stableforth PG (1984) Four-part fractures of the neck of the humerus. The Journal of Bone and Joint Surgery. Br Vol 66(1):104–108 Stableforth PG (1984) Four-part fractures of the neck of the humerus. The Journal of Bone and Joint Surgery. Br Vol 66(1):104–108
3.
Zurück zum Zitat Akalın Y, Şahin İG, Çevik N, Güler BO, Avci Ö, Öztürk A (2020) Locking compression plate fixation versus intramedullary nailing of humeral shaft fractures: Which one is better? A single-centre prospective randomized study. Int Orthop. https://doi.org/10.1007/s00264-020-04696-6 Akalın Y, Şahin İG, Çevik N, Güler BO, Avci Ö, Öztürk A (2020) Locking compression plate fixation versus intramedullary nailing of humeral shaft fractures: Which one is better? A single-centre prospective randomized study. Int Orthop. https://​doi.​org/​10.​1007/​s00264-020-04696-6
6.
Zurück zum Zitat Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P (2009) Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elb Surg 18(6):837–844CrossRef Thanasas C, Kontakis G, Angoules A, Limb D, Giannoudis P (2009) Treatment of proximal humerus fractures with locking plates: a systematic review. J Shoulder Elb Surg 18(6):837–844CrossRef
10.
Zurück zum Zitat Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164 Constant CR, Murley AH (1987) A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res 214:160–164
18.
Zurück zum Zitat Südkamp N, Bayer J, Hepp P, Voigt C, Oestern H, Kääb M, Luo C, Plecko M, Wendt K, Köstler W, Konrad G (2009) Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. J Bone Joint Surg Am 91(6):1320–1328. https://doi.org/10.2106/JBJS.H.00006CrossRefPubMed Südkamp N, Bayer J, Hepp P, Voigt C, Oestern H, Kääb M, Luo C, Plecko M, Wendt K, Köstler W, Konrad G (2009) Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. Results of a prospective, multicenter, observational study. J Bone Joint Surg Am 91(6):1320–1328. https://​doi.​org/​10.​2106/​JBJS.​H.​00006CrossRefPubMed
Metadaten
Titel
Comparison of “Bilboquet” device and locking plate for surgical treatment of proximal humerus complex fractures at two years follow-up
verfasst von
Yaniv Bismuth
Adeline Cambon-Binder
Alain Sautet
Levon Doursounian
Thomas Gregory
Claire Bastard
Publikationsdatum
24.02.2021
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 7/2021
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-021-04967-w