The aim of this study was to clarify the differences in thallium-201–chloride (thallium-201) myocardial perfusion imaging (MPI) scans evaluated by conventional anger-type single-photon emission computed tomography (conventional SPECT) versus cadmium–zinc–telluride SPECT (CZT SPECT) imaging in normal databases for different ethnic groups. MPI scans from 81 consecutive Japanese patients were examined using conventional SPECT and CZT SPECT and analyzed with the pre-installed quantitative perfusion SPECT (QPS) software. We compared the summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) for the two SPECT devices. For a normal MPI reference, we usually use Japanese databases for MPI created by the Japanese Society of Nuclear Medicine, which can be used with conventional SPECT but not with CZT SPECT. In this study, we used new Japanese normal databases constructed in our institution to compare conventional and CZT SPECT. Compared with conventional SPECT, CZT SPECT showed lower SSS (p < 0.001), SRS (p = 0.001), and SDS (p = 0.189) using the pre-installed SPECT database. In contrast, CZT SPECT showed no significant difference from conventional SPECT in QPS analysis using the normal databases from our institution. Myocardial perfusion analyses by CZT SPECT should be evaluated using normal databases based on the ethnic group being evaluated.
Literatur
1.
Zurück zum Zitat Mannting F, Morgan-Mannting MG (1993) Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities. J Nucl Med 34(4):601–608PubMed Mannting F, Morgan-Mannting MG (1993) Gated SPECT with technetium-99m-sestamibi for assessment of myocardial perfusion abnormalities. J Nucl Med 34(4):601–608PubMed
2.
Zurück zum Zitat DePuey EG, Rozanski A (1995) Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 36(6):952–955PubMed DePuey EG, Rozanski A (1995) Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med 36(6):952–955PubMed
3.
Zurück zum Zitat Iskandrian AE, Germano G, VanDecker W, Ogilby JD, Wolf N, Mintz R et al (1998) Validation of left ventricular volume measurements by gated SPECT 99mTc-labeled sestamibi imaging. J Nucl Cardiol 5(6):574–578CrossRefPubMed Iskandrian AE, Germano G, VanDecker W, Ogilby JD, Wolf N, Mintz R et al (1998) Validation of left ventricular volume measurements by gated SPECT 99mTc-labeled sestamibi imaging. J Nucl Cardiol 5(6):574–578CrossRefPubMed
4.
Zurück zum Zitat Shanoudy H, Raggi P, Beller GA, Soliman A, Ammermann EG, Kastner RJ et al (1998) Comparison of technetium-99m tetrofosmin and thallium-201 single-photon emission computed tomographic imaging for detection of myocardial perfusion defects in patients with coronary artery disease. J Am Coll Cardiol 31(2):331–337CrossRefPubMed Shanoudy H, Raggi P, Beller GA, Soliman A, Ammermann EG, Kastner RJ et al (1998) Comparison of technetium-99m tetrofosmin and thallium-201 single-photon emission computed tomographic imaging for detection of myocardial perfusion defects in patients with coronary artery disease. J Am Coll Cardiol 31(2):331–337CrossRefPubMed
5.
Zurück zum Zitat Husain SS (2007) Myocardial perfusion imaging protocols: is there an ideal protocol? J Nucl Med Technol 35(1):3–9PubMed Husain SS (2007) Myocardial perfusion imaging protocols: is there an ideal protocol? J Nucl Med Technol 35(1):3–9PubMed
6.
Zurück zum Zitat Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S et al (2008) High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 1(2):156–163CrossRefPubMed Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S et al (2008) High-speed myocardial perfusion imaging initial clinical comparison with conventional dual detector anger camera imaging. JACC Cardiovasc Imaging 1(2):156–163CrossRefPubMed
7.
Zurück zum Zitat Nakazato R, Slomka PJ, Fish M, Schwartz RG, Hayes SW, Thomson LE et al (2015) Quantitative high-efficiency cadmium-zinc-telluride SPECT with dedicated parallel-hole collimation system in obese patients: results of a multi-center study. J Nucl Cardiol 22(2):266–275CrossRefPubMed Nakazato R, Slomka PJ, Fish M, Schwartz RG, Hayes SW, Thomson LE et al (2015) Quantitative high-efficiency cadmium-zinc-telluride SPECT with dedicated parallel-hole collimation system in obese patients: results of a multi-center study. J Nucl Cardiol 22(2):266–275CrossRefPubMed
8.
Zurück zum Zitat Berman DS, Kang X, Tamarappoo B, Wolak A, Hayes SW, Nakazato R et al (2009) Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2(3):273–282CrossRefPubMed Berman DS, Kang X, Tamarappoo B, Wolak A, Hayes SW, Nakazato R et al (2009) Stress thallium-201/rest technetium-99m sequential dual isotope high-speed myocardial perfusion imaging. JACC Cardiovasc Imaging 2(3):273–282CrossRefPubMed
9.
Zurück zum Zitat Ben-Haim S, Kacperski K, Hain S, Van Gramberg D, Hutton BF, Erlandsson K et al (2010) Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera. Eur J Nucl Med Mol Imaging 37(9):1710–1721CrossRefPubMedPubMedCentral Ben-Haim S, Kacperski K, Hain S, Van Gramberg D, Hutton BF, Erlandsson K et al (2010) Simultaneous dual-radionuclide myocardial perfusion imaging with a solid-state dedicated cardiac camera. Eur J Nucl Med Mol Imaging 37(9):1710–1721CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Einstein AJ, Blankstein R, Andrews H, Fish M, Padgett R, Hayes SW et al (2014) Comparison of image quality, myocardial perfusion, and left ventricular function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: the MILLISIEVERT study. J Nucl Med 55(9):1430–1437CrossRefPubMedPubMedCentral Einstein AJ, Blankstein R, Andrews H, Fish M, Padgett R, Hayes SW et al (2014) Comparison of image quality, myocardial perfusion, and left ventricular function between standard imaging and single-injection ultra-low-dose imaging using a high-efficiency SPECT camera: the MILLISIEVERT study. J Nucl Med 55(9):1430–1437CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Tanaka H, Chikamori T, Tanaka N, Hida S, Igarashi Y, Yamashita J et al (2014) Diagnostic performance of a novel cadmium-zinc-telluride gamma camera system assessed using fractional flow reserve. Circ J 78(11):2727–2734CrossRefPubMed Tanaka H, Chikamori T, Tanaka N, Hida S, Igarashi Y, Yamashita J et al (2014) Diagnostic performance of a novel cadmium-zinc-telluride gamma camera system assessed using fractional flow reserve. Circ J 78(11):2727–2734CrossRefPubMed
12.
Zurück zum Zitat Hori Y, Yoda S, Nakanishi K, Tano A, Suzuki Y, Matsumoto N et al (2015) Myocardial ischemic reduction evidenced by gated myocardial perfusion imaging after treatment results in good prognosis in patients with coronary artery disease. J Cardiol 65(4):278–284CrossRefPubMed Hori Y, Yoda S, Nakanishi K, Tano A, Suzuki Y, Matsumoto N et al (2015) Myocardial ischemic reduction evidenced by gated myocardial perfusion imaging after treatment results in good prognosis in patients with coronary artery disease. J Cardiol 65(4):278–284CrossRefPubMed
13.
Zurück zum Zitat Shiraishi S, Sakamoto F, Tsuda N, Yoshida M, Tomiguchi S, Utsunomiya D et al (2015) Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera. Circ J 79(3):623–631CrossRefPubMed Shiraishi S, Sakamoto F, Tsuda N, Yoshida M, Tomiguchi S, Utsunomiya D et al (2015) Prediction of left main or 3-vessel disease using myocardial perfusion reserve on dynamic thallium-201 single-photon emission computed tomography with a semiconductor gamma camera. Circ J 79(3):623–631CrossRefPubMed
14.
Zurück zum Zitat Ishihara M, Taniguchi Y, Onoguchi M, Shibutani T (2016) Optimal thallium-201 dose in cadmium-zinc-telluride SPECT myocardial perfusion imaging. J Nucl Cardiol. doi:10.1007/s12350-016-0749-z Ishihara M, Taniguchi Y, Onoguchi M, Shibutani T (2016) Optimal thallium-201 dose in cadmium-zinc-telluride SPECT myocardial perfusion imaging. J Nucl Cardiol. doi:10.​1007/​s12350-016-0749-z
15.
Zurück zum Zitat Erlandsson K, Kacperski K, van Gramberg D, Hutton BF (2009) Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology. Phys Med Biol 54(9):2635–2649CrossRefPubMed Erlandsson K, Kacperski K, van Gramberg D, Hutton BF (2009) Performance evaluation of D-SPECT: a novel SPECT system for nuclear cardiology. Phys Med Biol 54(9):2635–2649CrossRefPubMed
16.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet 1(8476):307–310CrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. The Lancet 1(8476):307–310CrossRef
17.
Zurück zum Zitat Baggish AL, Boucher CA (2008) Radiopharmaceutical agents for myocardial perfusion imaging. Circulation 118(16):1668–1674CrossRefPubMed Baggish AL, Boucher CA (2008) Radiopharmaceutical agents for myocardial perfusion imaging. Circulation 118(16):1668–1674CrossRefPubMed
18.
Zurück zum Zitat Chen CC, Huang WS, Hung GU, Chen WC, Kao CH, Chen J (2013) Left-ventricular dyssynchrony evaluated by thallium-201 gated SPECT myocardial perfusion imaging: a comparison with Tc-99m sestamibi. Nucl Med Commun 34(3):229–232CrossRefPubMedPubMedCentral Chen CC, Huang WS, Hung GU, Chen WC, Kao CH, Chen J (2013) Left-ventricular dyssynchrony evaluated by thallium-201 gated SPECT myocardial perfusion imaging: a comparison with Tc-99m sestamibi. Nucl Med Commun 34(3):229–232CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Songy B, Lussato D, Guernou M, Queneau M, Geronazzo R (2011) Comparison of myocardial perfusion imaging using thallium-201 between a new cadmium-zinc-telluride cardiac camera and a conventional SPECT camera. Clin Nucl Med 36(9):776–780CrossRefPubMed Songy B, Lussato D, Guernou M, Queneau M, Geronazzo R (2011) Comparison of myocardial perfusion imaging using thallium-201 between a new cadmium-zinc-telluride cardiac camera and a conventional SPECT camera. Clin Nucl Med 36(9):776–780CrossRefPubMed
20.
Zurück zum Zitat Sharir T, Slomka PJ, Hayes SW, DiCarli MF, Ziffer JA, Martin WH et al (2010) Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging: quantitative results of myocardial perfusion and left ventricular function. J Am Coll Cardiol 55(18):1965–1974CrossRefPubMed Sharir T, Slomka PJ, Hayes SW, DiCarli MF, Ziffer JA, Martin WH et al (2010) Multicenter trial of high-speed versus conventional single-photon emission computed tomography imaging: quantitative results of myocardial perfusion and left ventricular function. J Am Coll Cardiol 55(18):1965–1974CrossRefPubMed
21.
Zurück zum Zitat Cuberas-Borrós G, Aguadé-Bruix S, Boronat-de Ferrater M, Muxi-Pradas MA, Romero-Farina G, Castell-Conesa J et al (2010) Normal myocardial perfusion SPECT database for the Spanish population. Rev Esp Cardiol 63(8):934–942CrossRefPubMed Cuberas-Borrós G, Aguadé-Bruix S, Boronat-de Ferrater M, Muxi-Pradas MA, Romero-Farina G, Castell-Conesa J et al (2010) Normal myocardial perfusion SPECT database for the Spanish population. Rev Esp Cardiol 63(8):934–942CrossRefPubMed
22.
Zurück zum Zitat Nakajima K, Kumita S, Ishida Y, Momose M, Hashimoto J, Morita K et al (2007) Creation and characterization of Japanese standards for myocardial perfusion SPECT: database from the Japanese Society of Nuclear Medicine Working Group. Ann Nucl Med 21(9):505–511CrossRefPubMed Nakajima K, Kumita S, Ishida Y, Momose M, Hashimoto J, Morita K et al (2007) Creation and characterization of Japanese standards for myocardial perfusion SPECT: database from the Japanese Society of Nuclear Medicine Working Group. Ann Nucl Med 21(9):505–511CrossRefPubMed
Metadaten
Titel
Comparison of conventional and cadmium–zinc–telluride single-photon emission computed tomography for analysis of thallium-201 myocardial perfusion imaging: an exploratory study in normal databases for different ethnicities
verfasst von
Masaru Ishihara
Masahisa Onoguchi
Yasuyo Taniguchi
Takayuki Shibutani
Publikationsdatum
29.06.2017
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 12/2017
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-017-1205-0

Weitere Artikel der Ausgabe 12/2017

The International Journal of Cardiovascular Imaging 12/2017 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.