Abstract

Centralising devices were introduced to ensure that the prosthesis is implanted in a neutral position and that a cement mantle of optimal thickness is achieved proximally and distally. A distal centralising device (DCD) is compared with a proximal midshaft centralising device (PCD) to test which one provides a more neutral prosthetic alignment. Thirty consecutive patients undergoing hemiarthroplasties for femoral neck fractures were studied prospectively. Patients were blindly randomised to receive either a femoral component with proximal midshaft centraliser or distal centraliser. Both components were implanted following the manufacturer’s protocol. Postoperative true anteroposterior and lateral radiographs were made to assess the stem position. There was no statistically significant difference between the two groups in zones 1, 2, 3, 4, 5, 6 and 7 in both anteroposterior and lateral radiographic measurements. DCP and PCD both have similar centralisation and cement mantle. Future studies should be done to evaluate their long-term effect.
Literatur
1.
Zurück zum Zitat Anthony PP, Gie GA, Howie CR, Ling RSM (1990) Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties. J Bone Joint Surg Br 72:971–979PubMed Anthony PP, Gie GA, Howie CR, Ling RSM (1990) Localised endosteal bone lysis in relation to the femoral components of cemented total hip arthroplasties. J Bone Joint Surg Br 72:971–979PubMed
2.
Zurück zum Zitat Berger RA, Seel MJ, Wood K et al (1997) Effect of a centralizing device on cement mantle deficiencies and initial prosthetic alignment in total hip arthroplasty. J Arthroplasty 12:434–443PubMedCrossRef Berger RA, Seel MJ, Wood K et al (1997) Effect of a centralizing device on cement mantle deficiencies and initial prosthetic alignment in total hip arthroplasty. J Arthroplasty 12:434–443PubMedCrossRef
3.
Zurück zum Zitat Charnley J (1979) Low friction arthroplasty of the hip. Theory and practice. Springer, New York, pp 66–90 Charnley J (1979) Low friction arthroplasty of the hip. Theory and practice. Springer, New York, pp 66–90
4.
Zurück zum Zitat Ebramzadeh E, Sarmiento A, McKellop HA et al (1994) The cement mantle in total hip arthroplasty. Analysis of long-term radiographic results. J Bone Joint Surg Am 76:77–87PubMed Ebramzadeh E, Sarmiento A, McKellop HA et al (1994) The cement mantle in total hip arthroplasty. Analysis of long-term radiographic results. J Bone Joint Surg Am 76:77–87PubMed
5.
Zurück zum Zitat Goldberg BA, Al-Habbal G, Noble PC et al (1998) Proximal and distal femoral centralizers in modern cemented hip arthroplasty. Clin Orthop Relat Res 349:163–173PubMedCrossRef Goldberg BA, Al-Habbal G, Noble PC et al (1998) Proximal and distal femoral centralizers in modern cemented hip arthroplasty. Clin Orthop Relat Res 349:163–173PubMedCrossRef
6.
Zurück zum Zitat Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed
7.
Zurück zum Zitat Huddleston HD (1988) Femoral lysis after cemented hip arthroplasty. J Arthroplasty 3:285–297PubMedCrossRef Huddleston HD (1988) Femoral lysis after cemented hip arthroplasty. J Arthroplasty 3:285–297PubMedCrossRef
8.
Zurück zum Zitat Johnston RC, Fitzgerald RH Jr, Harris WH et al (1990) Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg Am 72:161–168PubMed Johnston RC, Fitzgerald RH Jr, Harris WH et al (1990) Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J Bone Joint Surg Am 72:161–168PubMed
9.
Zurück zum Zitat Kawate K, Ohmura T, Nakajima H et al (2001) Distal cement mantle thickness with a triangular distal centralizer inserted into the stem tip in cemented total hip arthroplasty. J Arthroplasty 16(8):998–1003PubMedCrossRef Kawate K, Ohmura T, Nakajima H et al (2001) Distal cement mantle thickness with a triangular distal centralizer inserted into the stem tip in cemented total hip arthroplasty. J Arthroplasty 16(8):998–1003PubMedCrossRef
10.
Zurück zum Zitat Levy R, Noble P, Scheller A Jr, Tullos H, Turner R (1988) The clinical reproducibility of precise asymmetric femoral cement mantle for total hip replacement. Orthop Trans 12:591 Levy R, Noble P, Scheller A Jr, Tullos H, Turner R (1988) The clinical reproducibility of precise asymmetric femoral cement mantle for total hip replacement. Orthop Trans 12:591
11.
Zurück zum Zitat Pazzaglia UE (1990) Pathology of the bone-cement interface in loosening of total hip replacement. Arch Orthop Trauma Surg 109:83–88PubMedCrossRef Pazzaglia UE (1990) Pathology of the bone-cement interface in loosening of total hip replacement. Arch Orthop Trauma Surg 109:83–88PubMedCrossRef
12.
Zurück zum Zitat Søballe K, Christensen F (1988) Calcar resorption after total hip arthroplasty. J Arthroplasty 3:103–107PubMedCrossRef Søballe K, Christensen F (1988) Calcar resorption after total hip arthroplasty. J Arthroplasty 3:103–107PubMedCrossRef
13.
Zurück zum Zitat Star MJ, Colwell CW, Kelman GJ et al (1994) Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure. A retrospective radiographic analysis favoring distal stem centralization. J Arthroplasty 9(2):143–149PubMedCrossRef Star MJ, Colwell CW, Kelman GJ et al (1994) Suboptimal (thin) distal cement mantle thickness as a contributory factor in total hip arthroplasty femoral component failure. A retrospective radiographic analysis favoring distal stem centralization. J Arthroplasty 9(2):143–149PubMedCrossRef
Metadaten
Titel
Comparison of distal and proximal centralising devices in hip arthroplasty
verfasst von
N. Aydin
M. Bezer
A. H. Akgulle
B. Saygi
B. Kocaoğlu
O. Guven
Publikationsdatum
01.08.2009
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 4/2009
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-008-0610-3

Weitere Artikel der Ausgabe 4/2009

International Orthopaedics 4/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.