27.06.2015 | Original Research

Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output

verfasst von: Frederik Trinkmann, Manuel Berger, Christina Doesch, Theano Papavassiliu, Stefan O. Schoenberg, Martin Borggrefe, Jens J. Kaden, Joachim Saur

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 4/2016

Einloggen, um Zugang zu erhalten

Abstract

A novel algorithm of impedance cardiography referred to as electrical velocimetry (EV) has been introduced for non-invasive determination of cardiac output (CO). Previous validation studies yielded diverging results and no comparison with the non-invasive gold standard cardiac magnetic resonance imaging (CMR) has been performed. We therefore aimed to prospectively assess the accuracy and reproducibility of EV compared to CMR. 152 consecutive stable patients undergoing CMR were enrolled. EV measurements were taken twice before or after CMR in supine position and averaged over 20 s (AESCULON®, Osypka Medical, Berlin, Germany). Bland–Altman analysis showed insufficient agreement of EV and CMR with a mean bias of 1.2 ± 1.4 l/min (bias 23 ± 26 %, percentage error 51 %). Reproducibility was high with 0.0 ± 0.3 l/min (bias 0 ± 8 %, percentage error 15 %). Outlier analysis revealed gender, height, CO and stroke volume (SV) by CMR as independent predictors for larger variation. Stratification of COCMR in quintiles demonstrated a good agreement for low values (<4.4 l/min) with bias increasing significantly with quintile as high as 3.1 ± 1.1 l/min (p < 0.001). Reproducibility was not affected (p = 0.71). Subgroup analysis in patients with arrhythmias (p = 0.19), changes in thoracic fluid content (p = 0.51) or left heart failure (p = 0.47) could not detect significant differences in accuracy. EV showed insufficient agreement with CMR and good reproducibility. Gender, height and increasing CO and SV were associated with increased bias while not affecting reproducibility. Therefore, absolute values should not be used interchangeably in clinical routine. EV yet may find its place for clinical application with further investigation on its trending ability pending.
Literatur
1.
Zurück zum Zitat Pohost GM, Hung L, Doyle M. Clinical use of cardiovascular magnetic resonance. Circulation. 2003;108(6):647–53.CrossRefPubMed Pohost GM, Hung L, Doyle M. Clinical use of cardiovascular magnetic resonance. Circulation. 2003;108(6):647–53.CrossRefPubMed
2.
Zurück zum Zitat Kubicek WG, Karnegis JN, Patterson RP, Witsoe DA, Mattson RH. Development and evaluation of an impedance cardiac output system. Aerosp Med. 1966;37(12):1208–12.PubMed Kubicek WG, Karnegis JN, Patterson RP, Witsoe DA, Mattson RH. Development and evaluation of an impedance cardiac output system. Aerosp Med. 1966;37(12):1208–12.PubMed
3.
Zurück zum Zitat Appel PL, Kram HB, Mackabee J, Fleming AW, Shoemaker WC. Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients. Crit Care Med. 1986;14(11):933–5.CrossRefPubMed Appel PL, Kram HB, Mackabee J, Fleming AW, Shoemaker WC. Comparison of measurements of cardiac output by bioimpedance and thermodilution in severely ill surgical patients. Crit Care Med. 1986;14(11):933–5.CrossRefPubMed
4.
Zurück zum Zitat Franko E, Van De Water J, Wang X. Ideal measurement of cardiac output: is impedance cardiography the answer? Vasc Endovascular Surg. 1991;25:550–8.CrossRef Franko E, Van De Water J, Wang X. Ideal measurement of cardiac output: is impedance cardiography the answer? Vasc Endovascular Surg. 1991;25:550–8.CrossRef
5.
Zurück zum Zitat Carvalho P, Paiva R, Henriques J, Antunes M, Quintal I, Muehlsteff J. Robust characteristic points for ICG-definition and comparative analysis. Biosignals Rome, Italy; 2011. p. 161–8. Carvalho P, Paiva R, Henriques J, Antunes M, Quintal I, Muehlsteff J. Robust characteristic points for ICG-definition and comparative analysis. Biosignals Rome, Italy; 2011. p. 161–8.
6.
Zurück zum Zitat Norozi K, Beck C, Osthaus WA, Wille I, Wessel A, Bertram H. Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth. 2008;100(1):88–94.CrossRefPubMed Norozi K, Beck C, Osthaus WA, Wille I, Wessel A, Bertram H. Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth. 2008;100(1):88–94.CrossRefPubMed
7.
Zurück zum Zitat Osthaus WA, Huber D, Beck C, Winterhalter M, Boethig D, Wessel A, Sumpelmann R. Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets. Paediatr Anaesth. 2007;17(8):749–55.CrossRefPubMed Osthaus WA, Huber D, Beck C, Winterhalter M, Boethig D, Wessel A, Sumpelmann R. Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets. Paediatr Anaesth. 2007;17(8):749–55.CrossRefPubMed
8.
Zurück zum Zitat Schmidt C, Theilmeier G, Van Aken H, Korsmeier P, Wirtz SP, Berendes E, Hoffmeier A, Meissner A. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output. Br J Anaesth. 2005;95(5):603–10.CrossRefPubMed Schmidt C, Theilmeier G, Van Aken H, Korsmeier P, Wirtz SP, Berendes E, Hoffmeier A, Meissner A. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output. Br J Anaesth. 2005;95(5):603–10.CrossRefPubMed
9.
Zurück zum Zitat Suttner S, Schollhorn T, Boldt J, Mayer J, Rohm KD, Lang K, Piper SN. Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution. Intensive Care Med. 2006;32(12):2053–8.CrossRefPubMed Suttner S, Schollhorn T, Boldt J, Mayer J, Rohm KD, Lang K, Piper SN. Noninvasive assessment of cardiac output using thoracic electrical bioimpedance in hemodynamically stable and unstable patients after cardiac surgery: a comparison with pulmonary artery thermodilution. Intensive Care Med. 2006;32(12):2053–8.CrossRefPubMed
10.
Zurück zum Zitat Tomaske M, Knirsch W, Kretschmar O, Woitzek K, Balmer C, Schmitz A, Bauersfeld U, Weiss M. Cardiac output measurement in children: comparison of Aesculon cardiac output monitor and thermodilution. Br J Anaesth. 2008;100(4):517–20.CrossRefPubMed Tomaske M, Knirsch W, Kretschmar O, Woitzek K, Balmer C, Schmitz A, Bauersfeld U, Weiss M. Cardiac output measurement in children: comparison of Aesculon cardiac output monitor and thermodilution. Br J Anaesth. 2008;100(4):517–20.CrossRefPubMed
11.
Zurück zum Zitat Zoremba N, Bickenbach J, Krauss B, Rossaint R, Kuhlen R, Schalte G. Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand. 2007;51(10):1314–9.CrossRefPubMed Zoremba N, Bickenbach J, Krauss B, Rossaint R, Kuhlen R, Schalte G. Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand. 2007;51(10):1314–9.CrossRefPubMed
12.
Zurück zum Zitat Raue W, Swierzy M, Koplin G, Schwenk W. Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients. Eur J Anaesthesiol. 2009;26(12):1067–71.CrossRefPubMed Raue W, Swierzy M, Koplin G, Schwenk W. Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients. Eur J Anaesthesiol. 2009;26(12):1067–71.CrossRefPubMed
13.
Zurück zum Zitat Petter H, Erik A, Bjorn E, Goran R. Measurement of cardiac output with non-invasive Aesculon impedance versus thermodilution. Clin Physiol Funct Imaging. 2011;31(1):39–47.CrossRefPubMed Petter H, Erik A, Bjorn E, Goran R. Measurement of cardiac output with non-invasive Aesculon impedance versus thermodilution. Clin Physiol Funct Imaging. 2011;31(1):39–47.CrossRefPubMed
14.
Zurück zum Zitat Heringlake M, Handke U, Hanke T, Eberhardt F, Schumacher J, Gehring H, Heinze H. Lack of agreement between thermodilution and electrical velocimetry cardiac output measurements. Intensive Care Med. 2007;33(12):2168–72.CrossRefPubMed Heringlake M, Handke U, Hanke T, Eberhardt F, Schumacher J, Gehring H, Heinze H. Lack of agreement between thermodilution and electrical velocimetry cardiac output measurements. Intensive Care Med. 2007;33(12):2168–72.CrossRefPubMed
15.
Zurück zum Zitat Tomaske M, Knirsch W, Kretschmar O, Balmer C, Woitzek K, Schmitz A, Bauersfeld U, Weiss M. Evaluation of the Aesculon cardiac output monitor by subxiphoidal Doppler flow measurement in children with congenital heart defects. Eur J Anaesthesiol. 2009;26(5):412–5.CrossRefPubMed Tomaske M, Knirsch W, Kretschmar O, Balmer C, Woitzek K, Schmitz A, Bauersfeld U, Weiss M. Evaluation of the Aesculon cardiac output monitor by subxiphoidal Doppler flow measurement in children with congenital heart defects. Eur J Anaesthesiol. 2009;26(5):412–5.CrossRefPubMed
16.
Zurück zum Zitat Trinkmann F, Berger M, Hoffmann U, Borggrefe M, Kaden JJ, Saur J. A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output. Clin Res Cardiol. 2011;100(10):935–43.CrossRefPubMed Trinkmann F, Berger M, Hoffmann U, Borggrefe M, Kaden JJ, Saur J. A comparative evaluation of electrical velocimetry and inert gas rebreathing for the non-invasive assessment of cardiac output. Clin Res Cardiol. 2011;100(10):935–43.CrossRefPubMed
17.
Zurück zum Zitat Grollmuss O, Demontoux S, Capderou A, Serraf A, Belli E. Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery. Intensive Care Med. 2012;38(6):1032–9.CrossRefPubMed Grollmuss O, Demontoux S, Capderou A, Serraf A, Belli E. Electrical velocimetry as a tool for measuring cardiac output in small infants after heart surgery. Intensive Care Med. 2012;38(6):1032–9.CrossRefPubMed
18.
Zurück zum Zitat Bernstein D, Osypka M. Apparatus and method for determining an approximation of the stroke volume and the cardiac output of the heart. US Patent 6,511,438 B2; 2003. Bernstein D, Osypka M. Apparatus and method for determining an approximation of the stroke volume and the cardiac output of the heart. US Patent 6,511,438 B2; 2003.
19.
Zurück zum Zitat Papavassiliu T, Kuhl HP, Schroder M, Suselbeck T, Bondarenko O, Bohm CK, Beek A, Hofman MM, van Rossum AC. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology. 2005;236(1):57–64.CrossRefPubMed Papavassiliu T, Kuhl HP, Schroder M, Suselbeck T, Bondarenko O, Bohm CK, Beek A, Hofman MM, van Rossum AC. Effect of endocardial trabeculae on left ventricular measurements and measurement reproducibility at cardiovascular MR imaging. Radiology. 2005;236(1):57–64.CrossRefPubMed
20.
Zurück zum Zitat Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRefPubMed Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet. 1986;1(8476):307–10.CrossRefPubMed
21.
Zurück zum Zitat Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15(2):85–91.CrossRefPubMed Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15(2):85–91.CrossRefPubMed
22.
Zurück zum Zitat Woltjer HH, Bogaard HJ, van der Spoel HI, de Vries PM. The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients. Intensive Care Med. 1996;22(8):766–71.CrossRefPubMed Woltjer HH, Bogaard HJ, van der Spoel HI, de Vries PM. The influence of weight on stroke volume determination by means of impedance cardiography in cardiac surgery patients. Intensive Care Med. 1996;22(8):766–71.CrossRefPubMed
23.
Zurück zum Zitat Hoetink AE, Faes TJ, Schuur EH, Gorkink R, Goovaerts HG, Meijer JH, Heethaar RM. Comparing spot electrode arrangements for electric impedance cardiography. Physiol Meas. 2002;23(2):457–67.CrossRefPubMed Hoetink AE, Faes TJ, Schuur EH, Gorkink R, Goovaerts HG, Meijer JH, Heethaar RM. Comparing spot electrode arrangements for electric impedance cardiography. Physiol Meas. 2002;23(2):457–67.CrossRefPubMed
24.
Zurück zum Zitat Tan KH, Lai FO, Hwang NC. Measurement of cardiac output using Physio Flow with different positions of electrode placement. Singapore Med J. 2006;47(11):967–70.PubMed Tan KH, Lai FO, Hwang NC. Measurement of cardiac output using Physio Flow with different positions of electrode placement. Singapore Med J. 2006;47(11):967–70.PubMed
25.
Zurück zum Zitat Dhingra VK, Fenwick JC, Walley KR, Chittock DR, Ronco JJ. Lack of agreement between thermodilution and fick cardiac output in critically ill patients. Chest. 2002;122(3):990–7.CrossRefPubMed Dhingra VK, Fenwick JC, Walley KR, Chittock DR, Ronco JJ. Lack of agreement between thermodilution and fick cardiac output in critically ill patients. Chest. 2002;122(3):990–7.CrossRefPubMed
26.
Zurück zum Zitat van Grondelle A, Ditchey RV, Groves BM, Wagner WW Jr, Reeves JT. Thermodilution method overestimates low cardiac output in humans. Am J Physiol. 1983;245(4):H690–2.PubMed van Grondelle A, Ditchey RV, Groves BM, Wagner WW Jr, Reeves JT. Thermodilution method overestimates low cardiac output in humans. Am J Physiol. 1983;245(4):H690–2.PubMed
27.
Zurück zum Zitat Stetz CW, Miller RG, Kelly GE, Raffin TA. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis. 1982;126(6):1001–4.PubMed Stetz CW, Miller RG, Kelly GE, Raffin TA. Reliability of the thermodilution method in the determination of cardiac output in clinical practice. Am Rev Respir Dis. 1982;126(6):1001–4.PubMed
28.
Zurück zum Zitat Saur J, Fluechter S, Trinkmann F, Papavassiliu T, Schoenberg S, Weissmann J, Haghi D, Borggrefe M, Kaden JJ. Noninvasive determination of cardiac output by the inert-gas-rebreathing method—comparison with cardiovascular magnetic resonance imaging. Cardiology. 2009;114(4):247–54.CrossRefPubMed Saur J, Fluechter S, Trinkmann F, Papavassiliu T, Schoenberg S, Weissmann J, Haghi D, Borggrefe M, Kaden JJ. Noninvasive determination of cardiac output by the inert-gas-rebreathing method—comparison with cardiovascular magnetic resonance imaging. Cardiology. 2009;114(4):247–54.CrossRefPubMed
29.
Zurück zum Zitat Trinkmann F, Sampels M, Doesch C, Papavassiliu T, Brade J, Schmid-Bindert G, Hoffmann U, Borggrefe M, Kaden JJ, Saur J. Is arterial pulse contour analysis using Nexfin a new option in the noninvasive measurement of cardiac output?—A pilot study. J Cardiothorac Vasc Anesth. 2013;27(2):283–7.CrossRefPubMed Trinkmann F, Sampels M, Doesch C, Papavassiliu T, Brade J, Schmid-Bindert G, Hoffmann U, Borggrefe M, Kaden JJ, Saur J. Is arterial pulse contour analysis using Nexfin a new option in the noninvasive measurement of cardiac output?—A pilot study. J Cardiothorac Vasc Anesth. 2013;27(2):283–7.CrossRefPubMed
30.
Zurück zum Zitat Trinkmann F, Doesch C, Papavassiliu T, Weissmann J, Haghi D, Gruettner J, Schoenberg SO, Borggrefe M, Kaden JJ, Saur J. A novel noninvasive ultrasonic cardiac output monitor: comparison with cardiac magnetic resonance. Clin Cardiol. 2010;33(2):E8–14.CrossRefPubMed Trinkmann F, Doesch C, Papavassiliu T, Weissmann J, Haghi D, Gruettner J, Schoenberg SO, Borggrefe M, Kaden JJ, Saur J. A novel noninvasive ultrasonic cardiac output monitor: comparison with cardiac magnetic resonance. Clin Cardiol. 2010;33(2):E8–14.CrossRefPubMed
31.
Zurück zum Zitat Tan HL, Pinder M, Parsons R, Roberts B, van Heerden PV. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth. 2005;94(3):287–91.CrossRefPubMed Tan HL, Pinder M, Parsons R, Roberts B, van Heerden PV. Clinical evaluation of USCOM ultrasonic cardiac output monitor in cardiac surgical patients in intensive care unit. Br J Anaesth. 2005;94(3):287–91.CrossRefPubMed
32.
Zurück zum Zitat Williams BO, Caird FI. Accuracy of the impedance cardiogram in the measurement of cardiac output in the elderly. Age Ageing. 1985;14(5):277–81.CrossRefPubMed Williams BO, Caird FI. Accuracy of the impedance cardiogram in the measurement of cardiac output in the elderly. Age Ageing. 1985;14(5):277–81.CrossRefPubMed
33.
Zurück zum Zitat Berman IR, Scheetz WL, Jenkins EB, Hufnagel HV. Transthoracic electrical impedance s a guide to intravascular overload. Arch Surg. 1971;102(1):61–4.CrossRefPubMed Berman IR, Scheetz WL, Jenkins EB, Hufnagel HV. Transthoracic electrical impedance s a guide to intravascular overload. Arch Surg. 1971;102(1):61–4.CrossRefPubMed
34.
Zurück zum Zitat Penney BC. Theory and cardiac applications of electrical impedance measurements. Crit Rev Biomed Eng. 1986;13(3):227–81.PubMed Penney BC. Theory and cardiac applications of electrical impedance measurements. Crit Rev Biomed Eng. 1986;13(3):227–81.PubMed
35.
Zurück zum Zitat Pomerantz M, Delgado F, Eiseman B. Clinical evaluation of transthoracic electrical impedance as a guide to intrathoracic fluid volumes. Ann Surg. 1970;171(5):686–94.CrossRefPubMedPubMedCentral Pomerantz M, Delgado F, Eiseman B. Clinical evaluation of transthoracic electrical impedance as a guide to intrathoracic fluid volumes. Ann Surg. 1970;171(5):686–94.CrossRefPubMedPubMedCentral
36.
Zurück zum Zitat Saur J, Trinkmann F, Doesch C, Weissmann J, Hamm K, Schoenberg SO, Borggrefe M, Haghi D, Kaden JJ. Non-invasive measurement of cardiac output during atrial fibrillation: comparison between cardiac magnetic resonance imaging and inert gas rebreathing. Cardiology. 2010;115(3):212–6.CrossRefPubMed Saur J, Trinkmann F, Doesch C, Weissmann J, Hamm K, Schoenberg SO, Borggrefe M, Haghi D, Kaden JJ. Non-invasive measurement of cardiac output during atrial fibrillation: comparison between cardiac magnetic resonance imaging and inert gas rebreathing. Cardiology. 2010;115(3):212–6.CrossRefPubMed
37.
Zurück zum Zitat Tang WH, Tong W. Measuring impedance in congestive heart failure: current options and clinical applications. Am Heart J. 2009;157(3):402–11.CrossRefPubMed Tang WH, Tong W. Measuring impedance in congestive heart failure: current options and clinical applications. Am Heart J. 2009;157(3):402–11.CrossRefPubMed
38.
Zurück zum Zitat Voss F, Becker R, Hauck M, Katus HA, Bauer A. The basic pacing rate in CRT patients: the higher the better? Clin Res Cardiol. 2009;98(4):219–23.CrossRefPubMed Voss F, Becker R, Hauck M, Katus HA, Bauer A. The basic pacing rate in CRT patients: the higher the better? Clin Res Cardiol. 2009;98(4):219–23.CrossRefPubMed
39.
Zurück zum Zitat Tonelli AR, Alkukhun L, Arelli V, Ramos J, Newman J, McCarthy K, Pichurko B, Minai OA, Dweik RA. Value of impedance cardiography during 6-minute walk test in pulmonary hypertension. Clin Transl Sci. 2013;6(6):474–80.CrossRefPubMedPubMedCentral Tonelli AR, Alkukhun L, Arelli V, Ramos J, Newman J, McCarthy K, Pichurko B, Minai OA, Dweik RA. Value of impedance cardiography during 6-minute walk test in pulmonary hypertension. Clin Transl Sci. 2013;6(6):474–80.CrossRefPubMedPubMedCentral
40.
Zurück zum Zitat Lee WT, Brown A, Peacock AJ, Johnson MK. Use of non-invasive haemodynamic measurements to detect treatment response in precapillary pulmonary hypertension. Thorax. 2011;66(9):810–4.CrossRefPubMed Lee WT, Brown A, Peacock AJ, Johnson MK. Use of non-invasive haemodynamic measurements to detect treatment response in precapillary pulmonary hypertension. Thorax. 2011;66(9):810–4.CrossRefPubMed
41.
Zurück zum Zitat Flinck M, Graden A, Milde H, Flinck A, Hellstrom M, Bjork J, Nyman U. Cardiac output measured by electrical velocimetry in the CT suite correlates with coronary artery enhancement: a feasibility study. Acta Radiol. 2010;51(8):895–902.CrossRefPubMed Flinck M, Graden A, Milde H, Flinck A, Hellstrom M, Bjork J, Nyman U. Cardiac output measured by electrical velocimetry in the CT suite correlates with coronary artery enhancement: a feasibility study. Acta Radiol. 2010;51(8):895–902.CrossRefPubMed
42.
Zurück zum Zitat Liu Y, Pian-Smith MC, Leffert LR, Minehart RD, Torri A, Cote C, Kacmarek RM, Jiang Y. Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery. J Clin Monit Comput. 2014. doi:10.1007/s10877-014-9645-8. Liu Y, Pian-Smith MC, Leffert LR, Minehart RD, Torri A, Cote C, Kacmarek RM, Jiang Y. Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery. J Clin Monit Comput. 2014. doi:10.​1007/​s10877-014-9645-8.
43.
Zurück zum Zitat Kupersztych-Hagege E, Teboul JL, Artigas A, Talbot A, Sabatier C, Richard C, Monnet X. Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients. Br J Anaesth. 2013;111(6):961–6.CrossRefPubMed Kupersztych-Hagege E, Teboul JL, Artigas A, Talbot A, Sabatier C, Richard C, Monnet X. Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients. Br J Anaesth. 2013;111(6):961–6.CrossRefPubMed
Metadaten
Titel
Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output
verfasst von
Frederik Trinkmann
Manuel Berger
Christina Doesch
Theano Papavassiliu
Stefan O. Schoenberg
Martin Borggrefe
Jens J. Kaden
Joachim Saur
Publikationsdatum
27.06.2015
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 4/2016
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9731-6

Weitere Artikel der Ausgabe 4/2016

Journal of Clinical Monitoring and Computing 4/2016 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.