Skip to main content
Erschienen in: European Journal of Trauma and Emergency Surgery 3/2020

22.10.2018 | Original Article

Comparison of intraoperative 2D vs. 3D imaging in open reduction and fixation of distal radius fractures

verfasst von: Diego Hammerle, Georg Osterhoff, Florin Allemann, Clement Max Léonard Werner

Erschienen in: European Journal of Trauma and Emergency Surgery | Ausgabe 3/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

In the volar plating of distal radius fractures, intraoperative three-dimensional (3D) imaging is designed to allow better judgment regarding screw and implant positioning compared with conventional intraoperative two-dimensional (2D) imaging. We evaluated the impact of these two imaging modalities on the rates of intraoperative revision and secondary surgery, as well as the need for implant removal during follow-up.

Methods

A retrospective analysis of consecutive patients who underwent volar plate osteosynthesis for isolated distal radius fractures between January 2008 and April 2016 was performed. Patient files were evaluated for intraoperative imaging findings, intraoperative and postoperative revision rates, and implant removal during follow-up. Additional analyses of radiation exposure, operation time, and hospitalization time were performed.

Results

A total of 314 patients were analyzed (mean age: 54 ± 19 years; 210 females). For 246 patients, only 2D imaging was performed, while the remaining 68 patients underwent both 2D and 3D imaging (O-Arm, Medtronic). The intraoperative revision rate was significantly (p < 0.001) higher with 3D imaging (32.4%) compared with 2D imaging (2.0%). The postoperative revision rates were similar between both the groups (2.9% vs. 2.0%; p = 0.674). Compared with 2D imaging, the use of the Medtronic O-Arm resulted in a significantly lower implant removal rate (8.8% vs. 18.7%; p = 0.036) during follow-up.

Conclusion

Compared with conventional 2D imaging, the use of intraoperative 3D imaging significantly increased the intraoperative revision rate and has the potential for positive long-term effects for lowering the risk of requiring an implant removal.
Literatur
1.
Zurück zum Zitat Nana AD, Joshi A, Lichtman DM. Plating of the distal radius. J Am Acad Orthop Surg. 2005;13(3):159–71.CrossRef Nana AD, Joshi A, Lichtman DM. Plating of the distal radius. J Am Acad Orthop Surg. 2005;13(3):159–71.CrossRef
2.
Zurück zum Zitat Messer TM. Complications of volar plate fixation for managing distal. J Am Acad Orthop Surg. 2009;17(6):369–77.CrossRef Messer TM. Complications of volar plate fixation for managing distal. J Am Acad Orthop Surg. 2009;17(6):369–77.CrossRef
3.
Zurück zum Zitat Academy A, Board OS, December D. (2009) The treatment of distal radius fractures. Guidline and Evidence Report. Am Acad Orthop Surg Clin Pract Guid AAOS v1 0 12.05.09. Academy A, Board OS, December D. (2009) The treatment of distal radius fractures. Guidline and Evidence Report. Am Acad Orthop Surg Clin Pract Guid AAOS v1 0 12.05.09.
4.
Zurück zum Zitat Orbay J. Volar plate fixation of distal radius fractures. Hand Clin. 2005;21:347–54.CrossRef Orbay J. Volar plate fixation of distal radius fractures. Hand Clin. 2005;21:347–54.CrossRef
11.
Zurück zum Zitat Park DH, Tr F, Goldie BS. Volar plating for distal radius fractures—do not trust the image intensifier when judging distal subchondral screw length. Park DH, Tr F, Goldie BS. Volar plating for distal radius fractures—do not trust the image intensifier when judging distal subchondral screw length.
27.
Zurück zum Zitat Meier R, Kfuri M, Geerling J, et al. [Intraoperative three-dimensional imaging with an isocentric mobile C-arm at the wrist]. Handchirurgie, Mikrochirurgie, Plast Chir Organ der Deutschsprachigen Arbeitsgemeinschaft für Handchirurgie Organ der Deutschsprachigen Arbeitsgemeinschaft für Mikrochirurgie der Peripher Nerven und Gefässe. Organ der Vereinigung der Deut. 2005;37:256–9. https://doi.org/10.1055/s-2004-830563.CrossRef Meier R, Kfuri M, Geerling J, et al. [Intraoperative three-dimensional imaging with an isocentric mobile C-arm at the wrist]. Handchirurgie, Mikrochirurgie, Plast Chir Organ der Deutschsprachigen Arbeitsgemeinschaft für Handchirurgie Organ der Deutschsprachigen Arbeitsgemeinschaft für Mikrochirurgie der Peripher Nerven und Gefässe. Organ der Vereinigung der Deut. 2005;37:256–9. https://​doi.​org/​10.​1055/​s-2004-830563.CrossRef
Metadaten
Titel
Comparison of intraoperative 2D vs. 3D imaging in open reduction and fixation of distal radius fractures
verfasst von
Diego Hammerle
Georg Osterhoff
Florin Allemann
Clement Max Léonard Werner
Publikationsdatum
22.10.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Trauma and Emergency Surgery / Ausgabe 3/2020
Print ISSN: 1863-9933
Elektronische ISSN: 1863-9941
DOI
https://doi.org/10.1007/s00068-018-1036-2

Weitere Artikel der Ausgabe 3/2020

European Journal of Trauma and Emergency Surgery 3/2020 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.