Skip to main content
Erschienen in: European Journal of Clinical Microbiology & Infectious Diseases 9/2020

17.04.2020 | Original Article

Comparison of Legionella K-set® and BinaxNOW® Legionella for diagnosing Legionnaires’ disease on concentrated urine samples

verfasst von: Aubin Souche, Ghislaine Descours, Anne-Gaëlle Ranc, Gérard Lina, Sophie Jarraud, Laetitia Beraud

Erschienen in: European Journal of Clinical Microbiology & Infectious Diseases | Ausgabe 9/2020

Einloggen, um Zugang zu erhalten

Abstract

Detection of Legionella pneumophila serogroup 1 urinary antigens is the most widely used technique for the diagnosis of Legionnaires’ disease (LD). The aim of this study was to evaluate the performance of the Legionella K-set® immunochromatographic test, in comparison with the BinaxNOW® Legionella urinary antigen card (UAC) on concentrated urine samples (US). A total of 250 concentrated US including 200 prospective US sent to the laboratory for urinary antigens’ testing and 50 frozen US from patients with confirmed LD were tested. Positive US were retested after boiling (5 min, 100 °C). Each US leading to discordant results between the two tests was further tested using Binax™ Legionella EIA. Then, 10 additional positive non-concentrated US were tested using both tests. On concentrated US, Legionella K-set® test showed concordant results with that of BinaxNOW® Legionella. All negative US with BinaxNOW® were negative with Legionella K-set® test. For the 50 frozen US, all were positive with BinaxNOW® and 49 were positive with Legionella K-set®, all confirmed after boiling except 3 US which led to uninterpretable results with Legionella K-set®, due to a migration defect. Three of the 10 additional positive non-concentrated US were found negative with Legionella K-set® and only 1 US remained negative after concentration. All these positive non-concentrated US were positive with BinaxNOW® Legionella. The performance of the Legionella K-set® test is comparable to that of BinaxNOW® Legionella UAC, if performed on concentrated US.
Literatur
5.
Zurück zum Zitat Heath C, Grove D, Looke D (1996) Delay in appropriate therapy of Legionella pneumonia associated with increased mortality. Eur J Clin Microbiol Infect Dis 4(15):286–290CrossRef Heath C, Grove D, Looke D (1996) Delay in appropriate therapy of Legionella pneumonia associated with increased mortality. Eur J Clin Microbiol Infect Dis 4(15):286–290CrossRef
6.
Zurück zum Zitat Beauté J, Zucs P, De Jong B, on behalf of the European Legionnaires’ Disease Surveillance Network (2013) Legionnaires’ disease in Europe, 2009–2010. Euro Surveill 18(10):pll-20417CrossRef Beauté J, Zucs P, De Jong B, on behalf of the European Legionnaires’ Disease Surveillance Network (2013) Legionnaires’ disease in Europe, 2009–2010. Euro Surveill 18(10):pll-20417CrossRef
8.
Zurück zum Zitat Congestrì F, Crepaldi E, Gagliardi M, Pedna MF, Sambri V, Onderdonk AB (2016) Comparative evaluation of the novel bioNexia Legionella test with the BinaxNOW Legionella card assay and the Sofia Legionella FIA assay for detection of Legionella pneumophila (serogroup 1) antigen in urine samples. J Clin Microbiol 54(4):1164–1166. https://doi.org/10.1128/JCM.03340-15CrossRefPubMedPubMedCentral Congestrì F, Crepaldi E, Gagliardi M, Pedna MF, Sambri V, Onderdonk AB (2016) Comparative evaluation of the novel bioNexia Legionella test with the BinaxNOW Legionella card assay and the Sofia Legionella FIA assay for detection of Legionella pneumophila (serogroup 1) antigen in urine samples. J Clin Microbiol 54(4):1164–1166. https://​doi.​org/​10.​1128/​JCM.​03340-15CrossRefPubMedPubMedCentral
17.
Zurück zum Zitat Williams A, Lever MS (1995) Characterisation of Legionella pneumophila antigen in urine of Guinea pigs and humans with Legionnaires’ disease. J Inf Secur 30(1):13–16 Williams A, Lever MS (1995) Characterisation of Legionella pneumophila antigen in urine of Guinea pigs and humans with Legionnaires’ disease. J Inf Secur 30(1):13–16
20.
Zurück zum Zitat Muñoz M, Martínez Toldos M, Yaqüe G, Seqovia M (2009) Evaluation of three immunochromatographic assays for detection of Legionella pneumophila serogroup 1 antigen in urine samples. Rev Esp Quimioter 4(22):207–209 Muñoz M, Martínez Toldos M, Yaqüe G, Seqovia M (2009) Evaluation of three immunochromatographic assays for detection of Legionella pneumophila serogroup 1 antigen in urine samples. Rev Esp Quimioter 4(22):207–209
22.
Zurück zum Zitat Dominguez JA et al (1998) Comparison of the Binax Legionella urinary antigen enzyme immunoassay (EIA) with the biotest Legionella Urin antigen EIA for detection of Legionella antigen in both concentrated and nonconcentrated urine samples. J Clin Microbiol 36(9):2718–2722CrossRef Dominguez JA et al (1998) Comparison of the Binax Legionella urinary antigen enzyme immunoassay (EIA) with the biotest Legionella Urin antigen EIA for detection of Legionella antigen in both concentrated and nonconcentrated urine samples. J Clin Microbiol 36(9):2718–2722CrossRef
23.
Zurück zum Zitat Guerrero C, Toldos CM, Yagüe G, Ramírez C, Rodríguez T, Segovia M (2004) Comparison of diagnostic sensitivities of three assays (Bartels enzyme immunoassay [EIA], Biotest EIA, and Binax NOW immunochromatographic test) for detection of Legionella pneumophila serogroup 1 antigen in urine. J Clin Microbiol 42(1):467–468CrossRef Guerrero C, Toldos CM, Yagüe G, Ramírez C, Rodríguez T, Segovia M (2004) Comparison of diagnostic sensitivities of three assays (Bartels enzyme immunoassay [EIA], Biotest EIA, and Binax NOW immunochromatographic test) for detection of Legionella pneumophila serogroup 1 antigen in urine. J Clin Microbiol 42(1):467–468CrossRef
24.
Zurück zum Zitat Dominguez JA et al (1996) Detection of Legionella pneumophila serogroup 1 antigen in nonconcentrated urine and urine concentrated by selective ultrafiltration. J Clin Microbiol 34(9):2334–2336CrossRef Dominguez JA et al (1996) Detection of Legionella pneumophila serogroup 1 antigen in nonconcentrated urine and urine concentrated by selective ultrafiltration. J Clin Microbiol 34(9):2334–2336CrossRef
26.
Zurück zum Zitat Beraud L et al Performances of the BinaxNOW® Legionella urinary antigen rapid test in conjunction with the Alere™ Reader., Poster 11 Present. 9th Int. Conf. Legion. Rome 26th–30th Sept. 2017 Beraud L et al Performances of the BinaxNOW® Legionella urinary antigen rapid test in conjunction with the Alere™ Reader., Poster 11 Present. 9th Int. Conf. Legion. Rome 26th–30th Sept. 2017
27.
Zurück zum Zitat Deforges L, Legrand P, Tankovic J, Brun-Buisson C, Lang P, Soussy C-J (1999) Case of false-positive results of the urinary antigen test for Legionella pneumophila. Clin Infect Dis 29(4):953–954CrossRef Deforges L, Legrand P, Tankovic J, Brun-Buisson C, Lang P, Soussy C-J (1999) Case of false-positive results of the urinary antigen test for Legionella pneumophila. Clin Infect Dis 29(4):953–954CrossRef
28.
Zurück zum Zitat Doskeland SO, Berdal BP (1980) Bacterial antigen detection in body fluids: methods for rapid antigen concentration and reduction of nonspecific reactions. J Clin Microbiol 11(4):380–384CrossRef Doskeland SO, Berdal BP (1980) Bacterial antigen detection in body fluids: methods for rapid antigen concentration and reduction of nonspecific reactions. J Clin Microbiol 11(4):380–384CrossRef
Metadaten
Titel
Comparison of Legionella K-set® and BinaxNOW® Legionella for diagnosing Legionnaires’ disease on concentrated urine samples
verfasst von
Aubin Souche
Ghislaine Descours
Anne-Gaëlle Ranc
Gérard Lina
Sophie Jarraud
Laetitia Beraud
Publikationsdatum
17.04.2020
Verlag
Springer Berlin Heidelberg
Erschienen in
European Journal of Clinical Microbiology & Infectious Diseases / Ausgabe 9/2020
Print ISSN: 0934-9723
Elektronische ISSN: 1435-4373
DOI
https://doi.org/10.1007/s10096-020-03892-x

Weitere Artikel der Ausgabe 9/2020

European Journal of Clinical Microbiology & Infectious Diseases 9/2020 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Neu im Fachgebiet Innere Medizin

22.04.2024 | DGIM 2024 | Kongressbericht | Nachrichten

Krebspatienten impfen: Was? Wen? Und wann nicht?

22.04.2024 | DGIM 2024 | Kongressbericht | Nachrichten

Nierenultraschall: Tipps vom Profi

22.04.2024 | DGIM 2024 | Kongressbericht | Nachrichten

„KI sieht, was wir nicht sehen“

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.