Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 9/2017

20.02.2016 | Knee

Comparison of monoplanar versus biplanar medial opening-wedge high tibial osteotomy techniques for preventing lateral cortex fracture

verfasst von: Faik Türkmen, Burkay K. Kaçıra, Mustafa Özkaya, Ömer F. Erkoçak, Mehmet A. Acar, Mustafa Özer, Serdar Toker, Teyfik Demir

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 9/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to investigate the mechanical strength of both monoplanar and biplanar medial opening-wedge high tibial osteotomy (MOWHTO) procedures and assess the risk of lateral cortex disruption for both techniques.

Methods

Twelve synthetic tibia models with cortical shells were used as test models. Saw cuts for monoplanar MOWHTO and biplanar MOWHTO were generated on the test models in equal numbers (n = 6 for both groups). Wedge opening load and wedge gap distance were evaluated via compressive tests.

Results

The mean gap distance just before the lateral cortex fracture in the monoplanar group was 14.7 ± 2.9 mm, which was significantly narrower than that in the biplanar group of 19.1 ± 2.0 mm (p = 0.015). The mean load just before the occurrence of lateral cortex fracture of 32.4 ± 3.2 N in the monoplanar osteotomy group was significantly lower than that in the biplanar osteotomy group of 111.8 ± 9.3 N (p = 0.009).

Conclusion

Performing a MOWHTO via the biplanar rather than the monoplanar technique allows larger-sized wedges to be opened with less risk of lateral cortical fracture. Thus, larger gaps can be opened and higher angle corrections can be achieved using the biplanar osteotomy procedure. From a clinical viewpoint, the biplanar osteotomy technique reduced the risk of lateral cortical hinge fracture during MOWHTO.
Literatur
1.
Zurück zum Zitat Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14(3):291–300CrossRefPubMed Agneskirchner JD, Freiling D, Hurschler C, Lobenhoffer P (2006) Primary stability of four different implants for opening wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 14(3):291–300CrossRefPubMed
2.
Zurück zum Zitat Chae DJ, Shetty GM, Wang KH, Montalban AS Jr, Kim JI, Nha KW (2011) Early complications of medial opening wedge high tibial osteotomy using autologous tricortical iliac bone graft and T-plate fixation. Knee 18(4):278–284CrossRefPubMed Chae DJ, Shetty GM, Wang KH, Montalban AS Jr, Kim JI, Nha KW (2011) Early complications of medial opening wedge high tibial osteotomy using autologous tricortical iliac bone graft and T-plate fixation. Knee 18(4):278–284CrossRefPubMed
3.
Zurück zum Zitat Coventry MB (1965) Osteotomy of the upper portion of the tibia for degenerative arthritis of the knee. A preliminary report. J Bone Joint Surg Am 47:984–990CrossRefPubMed Coventry MB (1965) Osteotomy of the upper portion of the tibia for degenerative arthritis of the knee. A preliminary report. J Bone Joint Surg Am 47:984–990CrossRefPubMed
4.
Zurück zum Zitat Coventry MB, Ilstrup DM, Wallrichs SL (1993) Proximal tibial osteotomy. A critical long-term study of eighty-seven cases. J Bone Joint Surg Am 75(2):196–201CrossRefPubMed Coventry MB, Ilstrup DM, Wallrichs SL (1993) Proximal tibial osteotomy. A critical long-term study of eighty-seven cases. J Bone Joint Surg Am 75(2):196–201CrossRefPubMed
5.
Zurück zum Zitat Elmalı N, Esenkaya I, Can M, Karakaplan M (2013) Monoplanar versus biplanar medial open-wedge proximal tibial osteotomy for varus gonarthrosis: a comparison of clinical and radiological outcomes. Knee Surg Sports Traumatol Arthrosc 21(12):2689–2695CrossRefPubMed Elmalı N, Esenkaya I, Can M, Karakaplan M (2013) Monoplanar versus biplanar medial open-wedge proximal tibial osteotomy for varus gonarthrosis: a comparison of clinical and radiological outcomes. Knee Surg Sports Traumatol Arthrosc 21(12):2689–2695CrossRefPubMed
6.
Zurück zum Zitat Han SB, Lee DH, Shetty GM, Chae DJ, Song JG, Nha KW (2013) A “safe zone” in medial open-wedge high tibia osteotomy to prevent lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 21(1):90–95CrossRefPubMed Han SB, Lee DH, Shetty GM, Chae DJ, Song JG, Nha KW (2013) A “safe zone” in medial open-wedge high tibia osteotomy to prevent lateral cortex fracture. Knee Surg Sports Traumatol Arthrosc 21(1):90–95CrossRefPubMed
7.
Zurück zum Zitat Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69(3):332–354CrossRefPubMed Hernigou P, Medevielle D, Debeyre J, Goutallier D (1987) Proximal tibial osteotomy for osteoarthritis with varus deformity. A ten to thirteen-year follow-up study. J Bone Joint Surg Am 69(3):332–354CrossRefPubMed
8.
Zurück zum Zitat Insall JN, Joseph DM, Msika C (1984) High tibial osteotomy for varus gonarthrosis. A long-term follow-up study. J Bone Joint Surg Am 66(7):1040–1048CrossRefPubMed Insall JN, Joseph DM, Msika C (1984) High tibial osteotomy for varus gonarthrosis. A long-term follow-up study. J Bone Joint Surg Am 66(7):1040–1048CrossRefPubMed
9.
Zurück zum Zitat Jacobi M, Wahl P, Jakob RP (2010) Avoiding intraoperative complications in open-wedge high tibial valgus osteotomy: technical advancement. Knee Surg Sports Traumatol Arthrosc 18(2):200–203CrossRefPubMed Jacobi M, Wahl P, Jakob RP (2010) Avoiding intraoperative complications in open-wedge high tibial valgus osteotomy: technical advancement. Knee Surg Sports Traumatol Arthrosc 18(2):200–203CrossRefPubMed
10.
Zurück zum Zitat Kazimoğlu C, Akdoğan Y, Sener M, Kurtulmuş A, Karapinar H, Uzun B (2008) Which is the best fixation method for lateral cortex disruption in the medial open wedge high tibial osteotomy? A biomechanical study. Knee 15(4):305–308CrossRefPubMed Kazimoğlu C, Akdoğan Y, Sener M, Kurtulmuş A, Karapinar H, Uzun B (2008) Which is the best fixation method for lateral cortex disruption in the medial open wedge high tibial osteotomy? A biomechanical study. Knee 15(4):305–308CrossRefPubMed
11.
Zurück zum Zitat Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11(3):132–138CrossRefPubMed Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11(3):132–138CrossRefPubMed
12.
Zurück zum Zitat Lobenhoffer P, De Simoni C, Staubli A (2002) Open-wedge high-tibial osteotomy with rigid plate fixation. Tech Knee Surg 1:93–105CrossRef Lobenhoffer P, De Simoni C, Staubli A (2002) Open-wedge high-tibial osteotomy with rigid plate fixation. Tech Knee Surg 1:93–105CrossRef
13.
Zurück zum Zitat Lustig S, Scholes CJ, Costa AJ, Coolican MJ, Parker DA (2013) Different changes in slope between the medial and lateral tibial plateau after open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 21(1):32–38CrossRefPubMed Lustig S, Scholes CJ, Costa AJ, Coolican MJ, Parker DA (2013) Different changes in slope between the medial and lateral tibial plateau after open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 21(1):32–38CrossRefPubMed
14.
Zurück zum Zitat Madry H, Ziegler R, Orth P, Goebel L, Ong MF, Kohn D, Cucchiarini M, Pape D (2012) Effect of open wedge high tibial osteotomy on the lateral compartment in sheep. Part I: analysis of the lateral meniscus. Knee Surg Sports Traumatol Arthrosc 21(1):39–48CrossRefPubMed Madry H, Ziegler R, Orth P, Goebel L, Ong MF, Kohn D, Cucchiarini M, Pape D (2012) Effect of open wedge high tibial osteotomy on the lateral compartment in sheep. Part I: analysis of the lateral meniscus. Knee Surg Sports Traumatol Arthrosc 21(1):39–48CrossRefPubMed
15.
Zurück zum Zitat Miller BS, DorseyWO BC, Austin JC (2005) The effect of lateral cortex disruption and repair on the stability of medial opening wedge high tibial osteotomy. Am J Sports Med 33(10):1552–1557CrossRefPubMed Miller BS, DorseyWO BC, Austin JC (2005) The effect of lateral cortex disruption and repair on the stability of medial opening wedge high tibial osteotomy. Am J Sports Med 33(10):1552–1557CrossRefPubMed
16.
Zurück zum Zitat Miller BS, Downie B, McDonough EB, Wojtys EM (2009) Complications after medial opening wedge high tibial osteotomy. Arthroscopy 25(6):639–646CrossRefPubMed Miller BS, Downie B, McDonough EB, Wojtys EM (2009) Complications after medial opening wedge high tibial osteotomy. Arthroscopy 25(6):639–646CrossRefPubMed
17.
Zurück zum Zitat Nelissen EM, van Langelaan EJ, Nelissen RG (2010) Stability of medial opening wedge high tibial osteotomy: a failure analysis. Int Orthop 34(2):217–223CrossRefPubMed Nelissen EM, van Langelaan EJ, Nelissen RG (2010) Stability of medial opening wedge high tibial osteotomy: a failure analysis. Int Orthop 34(2):217–223CrossRefPubMed
18.
Zurück zum Zitat Paccola CA, Fogagnolo F (2005) Open-wedge high tibial osteotomy: a technical trick to avoid loss of reduction of the opposite cortex. Knee Surg Sports Traumatol Arthrosc 13(1):19–22CrossRefPubMed Paccola CA, Fogagnolo F (2005) Open-wedge high tibial osteotomy: a technical trick to avoid loss of reduction of the opposite cortex. Knee Surg Sports Traumatol Arthrosc 13(1):19–22CrossRefPubMed
19.
Zurück zum Zitat Pape D, Adam F, Rupp S, Seil R, Kohn D (2004) Stability, bone healing and loss of correction after valgus realignment of the tibial head. A roentgen stereometry analysis. Orthopade 33(2):208–217CrossRefPubMed Pape D, Adam F, Rupp S, Seil R, Kohn D (2004) Stability, bone healing and loss of correction after valgus realignment of the tibial head. A roentgen stereometry analysis. Orthopade 33(2):208–217CrossRefPubMed
20.
Zurück zum Zitat Pape D, Madry H (2013) The preclinical sheep model of high tibial osteotomy relating basic science to the clinics: standards, techniques and pitfalls. Knee Surg Sports Traumatol Arthrosc 21(1):228–236CrossRefPubMed Pape D, Madry H (2013) The preclinical sheep model of high tibial osteotomy relating basic science to the clinics: standards, techniques and pitfalls. Knee Surg Sports Traumatol Arthrosc 21(1):228–236CrossRefPubMed
21.
Zurück zum Zitat Rho JY, Tsui TY, Pharr GM (1997) Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. Biomaterials 18:1325–1330CrossRefPubMed Rho JY, Tsui TY, Pharr GM (1997) Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation. Biomaterials 18:1325–1330CrossRefPubMed
22.
Zurück zum Zitat Rose T, Imhoff AB (2007) Complications after transgenicular osteotomies. Oper Tech Orthop 17:80–86CrossRef Rose T, Imhoff AB (2007) Complications after transgenicular osteotomies. Oper Tech Orthop 17:80–86CrossRef
23.
Zurück zum Zitat Saengnipanthkul S (2012) Uni-condyle high tibial osteotomy for malunion of medial plateau fracture: surgical technique and case report. J Med Assoc Thai 95(12):1619–1624PubMed Saengnipanthkul S (2012) Uni-condyle high tibial osteotomy for malunion of medial plateau fracture: surgical technique and case report. J Med Assoc Thai 95(12):1619–1624PubMed
24.
Zurück zum Zitat Spahn G (2004) Complications in high tibial (medial opening wedge) osteotomy. Arch Orthop Trauma Surg 124(10):649–653CrossRefPubMed Spahn G (2004) Complications in high tibial (medial opening wedge) osteotomy. Arch Orthop Trauma Surg 124(10):649–653CrossRefPubMed
25.
Zurück zum Zitat Spahn G, Wittig R (2002) Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study. J Orthop Sci 7(6):683–687CrossRefPubMed Spahn G, Wittig R (2002) Primary stability of various implants in tibial opening wedge osteotomy: a biomechanical study. J Orthop Sci 7(6):683–687CrossRefPubMed
26.
Zurück zum Zitat Stoffel K, Stachowiak G, Kuster M (2004) Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex osteotomy plate (Puddu Plate) and the TomoFix Plate. Clin Biomech (Bristol, Avon) 19(9):944–950CrossRef Stoffel K, Stachowiak G, Kuster M (2004) Open wedge high tibial osteotomy: biomechanical investigation of the modified Arthrex osteotomy plate (Puddu Plate) and the TomoFix Plate. Clin Biomech (Bristol, Avon) 19(9):944–950CrossRef
27.
Zurück zum Zitat Takeuchi R, Ishikawa H, Kumagai K, Yamaguchi Y, Chiba N, Akamatsu Y, Saito T (2012) Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Arthroscopy 28(1):85–94CrossRefPubMed Takeuchi R, Ishikawa H, Kumagai K, Yamaguchi Y, Chiba N, Akamatsu Y, Saito T (2012) Fractures around the lateral cortical hinge after a medial opening-wedge high tibial osteotomy: a new classification of lateral hinge fracture. Arthroscopy 28(1):85–94CrossRefPubMed
28.
Zurück zum Zitat Türkmen F, Sever C, Kacıra BK, Demirayak M, Acar MA, Toker S (2014) Medial opening-wedge high tibial osteotomy fixation with short plate without any graft, synthetic material or spacer. Eur J Orthop Surg Traumatol 24(8):1549–1555CrossRefPubMed Türkmen F, Sever C, Kacıra BK, Demirayak M, Acar MA, Toker S (2014) Medial opening-wedge high tibial osteotomy fixation with short plate without any graft, synthetic material or spacer. Eur J Orthop Surg Traumatol 24(8):1549–1555CrossRefPubMed
29.
Zurück zum Zitat van Heerwaarden R, Najfeld M, Brinkman M, Seil R, Madry H, Pape D (2013) Wedge volume and osteotomy surface depend on surgical technique for distal femoral osteotomy. Knee Surg Sports Traumatol Arthrosc 21(1):206–212CrossRefPubMed van Heerwaarden R, Najfeld M, Brinkman M, Seil R, Madry H, Pape D (2013) Wedge volume and osteotomy surface depend on surgical technique for distal femoral osteotomy. Knee Surg Sports Traumatol Arthrosc 21(1):206–212CrossRefPubMed
30.
Zurück zum Zitat van Raaij TM, Brouwer RW, de Vlieger R, Reijman M, Verhaar JA (2008) Opposite cortical fracture in high tibial osteotomy: lateral closing compared to the medial opening-wedge technique. Acta Orthop 79(4):508–514CrossRefPubMed van Raaij TM, Brouwer RW, de Vlieger R, Reijman M, Verhaar JA (2008) Opposite cortical fracture in high tibial osteotomy: lateral closing compared to the medial opening-wedge technique. Acta Orthop 79(4):508–514CrossRefPubMed
Metadaten
Titel
Comparison of monoplanar versus biplanar medial opening-wedge high tibial osteotomy techniques for preventing lateral cortex fracture
verfasst von
Faik Türkmen
Burkay K. Kaçıra
Mustafa Özkaya
Ömer F. Erkoçak
Mehmet A. Acar
Mustafa Özer
Serdar Toker
Teyfik Demir
Publikationsdatum
20.02.2016
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 9/2017
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-016-4049-6

Weitere Artikel der Ausgabe 9/2017

Knee Surgery, Sports Traumatology, Arthroscopy 9/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.