Skip to main content
Erschienen in: Abdominal Radiology 2/2017

28.09.2016

Comparison of MRI- and CT-based semiautomated liver segmentation: a validation study

verfasst von: Akshat Gotra, Gabriel Chartrand, Kim-Nhien Vu, Franck Vandenbroucke-Menu, Karine Massicotte-Tisluck, Jacques A. de Guise, An Tang

Erschienen in: Abdominal Radiology | Ausgabe 2/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To compare the repeatability, agreement, and efficiency of MRI- and CT-based semiautomated liver segmentation for the assessment of total and subsegmental liver volume.

Methods

This retrospective study was conducted in 31 subjects who underwent contemporaneous liver MRI and CT. Total and subsegmental liver volumes were segmented from contrast-enhanced 3D gradient-recalled echo MRI sequences and CT images. Semiautomated segmentation was based on variational interpolation and Laplacian mesh optimization. All segmentations were repeated after 2 weeks. Manual segmentation of CT images using an active contour tool was used as the reference standard. Repeatability and agreement of the methods were evaluated with intra-class correlation coefficients (ICC) and Bland–Altman analysis. Total interaction time was recorded.

Results

Intra-reader ICC were ≥0.987 for MRI and ≥0.995 for CT. Intra-reader repeatability was 30 ± 217 ml (bias ± 1.96 SD) (95% limits of agreement: −187 to 247 ml) for MRI and −10 ± 143 ml (−153 to 133 ml) for CT. Inter-method ICC between semiautomated and manual volumetry were ≥0.995 for MRI and ≥0.986 for CT. Inter-method segmental ICC varied between 0.584 and 0.865 for MRI and between 0.596 and 0.890 for CT. Inter-method agreement was –14 ± 136 ml (−150 to 122 ml) for MRI and 50 ± 226 ml (−176 to 276 ml) for CT. Inter-method segmental agreement ranged from 10 ± 47 ml (−37 to 57 ml) to 2 ± 214 ml (−212 to 216 ml) for MRI and 9 ± 45 ml (−36 to 54 ml) to −46 ± 183 ml (−229 to 137 ml) for CT. Interaction time (mean ± SD) was significantly shorter for MRI-based semiautomated segmentation (7.2 ± 0.1 min, p < 0.001) and for CT-based semiautomated segmentation (6.5 ± 0.2 min, p < 0.001) than for CT-based manual segmentation (14.5 ± 0.4 min).

Conclusion

MRI-based semiautomated segmentation provides similar repeatability and agreement to CT-based segmentation for total liver volume.
Literatur
3.
Zurück zum Zitat Massoptier L, Casciaro S (2008) A new fully automatic and robust algorithm for fast segmentation of liver tissue and tumors from CT scans. Eur Radiol 18(8):1658–1665CrossRefPubMed Massoptier L, Casciaro S (2008) A new fully automatic and robust algorithm for fast segmentation of liver tissue and tumors from CT scans. Eur Radiol 18(8):1658–1665CrossRefPubMed
5.
Zurück zum Zitat Masutani Y, Uozumi K, Akahane M, Ohtomo K (2006) Liver CT image processing: a short introduction of the technical elements. Eur J Radiol 58(2):246–251CrossRefPubMed Masutani Y, Uozumi K, Akahane M, Ohtomo K (2006) Liver CT image processing: a short introduction of the technical elements. Eur J Radiol 58(2):246–251CrossRefPubMed
7.
Zurück zum Zitat Fulcher AS, Szucs RA, Bassignani MJ, Marcos A (2001) Right lobe living donor liver transplantation: preoperative evaluation of the donor with MR imaging. Ajr 176(6):1483–1491CrossRefPubMed Fulcher AS, Szucs RA, Bassignani MJ, Marcos A (2001) Right lobe living donor liver transplantation: preoperative evaluation of the donor with MR imaging. Ajr 176(6):1483–1491CrossRefPubMed
8.
Zurück zum Zitat Reeder SB, Cruite I, Hamilton G, Sirlin CB (2011) Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy. J Magn Reson Imaging JMRI 34 (4):spcone. doi:10.1002/jmri.22775 Reeder SB, Cruite I, Hamilton G, Sirlin CB (2011) Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy. J Magn Reson Imaging JMRI 34 (4):spcone. doi:10.​1002/​jmri.​22775
11.
Zurück zum Zitat d’Assignies G, Kauffmann C, Boulanger Y, et al. (2011) Simultaneous assessment of liver volume and whole liver fat content: a step towards one-stop shop preoperative MRI protocol. Eur Radiol 21(2):301–309. doi:10.1007/s00330-010-1941-1 CrossRefPubMed d’Assignies G, Kauffmann C, Boulanger Y, et al. (2011) Simultaneous assessment of liver volume and whole liver fat content: a step towards one-stop shop preoperative MRI protocol. Eur Radiol 21(2):301–309. doi:10.​1007/​s00330-010-1941-1 CrossRefPubMed
17.
Zurück zum Zitat Chartrand G, Cresson T, Chav R, et al. (2013) Semi-automated liver CT segmentation using Laplacian meshes. In: 2014 IEEE international symposium on biomedical imaging, Beiing, China Chartrand G, Cresson T, Chav R, et al. (2013) Semi-automated liver CT segmentation using Laplacian meshes. In: 2014 IEEE international symposium on biomedical imaging, Beiing, China
19.
Zurück zum Zitat Couinaud C (1957) Le Foie: études anatomiques et chirurgicales. Paris: Masson Couinaud C (1957) Le Foie: études anatomiques et chirurgicales. Paris: Masson
20.
Zurück zum Zitat Kass M, Witkin A, Terzopoulos D (1988) Snakes: active Contour Models. Int J Comput Vis 1(4):321–331CrossRef Kass M, Witkin A, Terzopoulos D (1988) Snakes: active Contour Models. Int J Comput Vis 1(4):321–331CrossRef
22.
Zurück zum Zitat Wimmer A, Soza G, Hornegger J (2007) Two-stage semi-automatic organ segmentation framework using radial basis functions and level sets. In: Proceedings of MICCAI 2007 workshop: 3D segmentation in the clinic-a grand challenge, pp. 179–188 Wimmer A, Soza G, Hornegger J (2007) Two-stage semi-automatic organ segmentation framework using radial basis functions and level sets. In: Proceedings of MICCAI 2007 workshop: 3D segmentation in the clinic-a grand challenge, pp. 179–188
24.
Zurück zum Zitat Heckel F, Konrad O, Hahn HK, Peitgen HO (2010) Interactive 3D medical image segmentation with energy-minimizing implicit functions. Comput Graph 35(2):275–287CrossRef Heckel F, Konrad O, Hahn HK, Peitgen HO (2010) Interactive 3D medical image segmentation with energy-minimizing implicit functions. Comput Graph 35(2):275–287CrossRef
25.
Zurück zum Zitat Nealen A, Igarashi T, Sorkine O, Alexa M (2006) Laplacian mesh optimization. In: Proceedings of the 4th international conference on Computer graphics and interactive techniques in Australasia and Southeast Asia - GRAPHITE ‘06. doi:10.1145/1174429.1174494 Nealen A, Igarashi T, Sorkine O, Alexa M (2006) Laplacian mesh optimization. In: Proceedings of the 4th international conference on Computer graphics and interactive techniques in Australasia and Southeast Asia - GRAPHITE ‘06. doi:10.​1145/​1174429.​1174494
27.
Zurück zum Zitat Mazonakis M, Damilakis J, Maris T, Prassopoulos P, Gourtsoyiannis N (2002) Comparison of two volumetric techniques for estimating liver volume using magnetic resonance imaging. J Magn Reson Imaging JMRI 15(5):557–563. doi:10.1002/jmri.10109 CrossRefPubMed Mazonakis M, Damilakis J, Maris T, Prassopoulos P, Gourtsoyiannis N (2002) Comparison of two volumetric techniques for estimating liver volume using magnetic resonance imaging. J Magn Reson Imaging JMRI 15(5):557–563. doi:10.​1002/​jmri.​10109 CrossRefPubMed
32.
Zurück zum Zitat Lemke AJ, Brinkmann MJ, Pascher A, et al. (2003) Accuracy of the CT-estimated weight of the right hepatic lobe prior to living related liver donation (LRLD) for predicting the intraoperatively measured weight of the graft. RoFo Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin 175(9):1232–1238. doi:10.1055/s-2003-41938 CrossRefPubMed Lemke AJ, Brinkmann MJ, Pascher A, et al. (2003) Accuracy of the CT-estimated weight of the right hepatic lobe prior to living related liver donation (LRLD) for predicting the intraoperatively measured weight of the graft. RoFo Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin 175(9):1232–1238. doi:10.​1055/​s-2003-41938 CrossRefPubMed
33.
Zurück zum Zitat Frericks BB, Kiene T, Stamm G, Shin H, Galanski M (2004) CT-based liver volumetry in a porcine model: impact on clinical volumetry prior to living donated liver transplantation. RoFo Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin 176(2):252–257. doi:10.1055/s-2004-817636 CrossRefPubMed Frericks BB, Kiene T, Stamm G, Shin H, Galanski M (2004) CT-based liver volumetry in a porcine model: impact on clinical volumetry prior to living donated liver transplantation. RoFo Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin 176(2):252–257. doi:10.​1055/​s-2004-817636 CrossRefPubMed
34.
Zurück zum Zitat Niehues SM, Unger JK, Malinowski M, et al. (2010) Liver volume measurement: reason of the difference between in vivo CT-volumetry and intraoperative ex vivo determination and how to cope it. Eur J Med Res 15(8):345–350CrossRefPubMedPubMedCentral Niehues SM, Unger JK, Malinowski M, et al. (2010) Liver volume measurement: reason of the difference between in vivo CT-volumetry and intraoperative ex vivo determination and how to cope it. Eur J Med Res 15(8):345–350CrossRefPubMedPubMedCentral
36.
Zurück zum Zitat Schiano TD, Bodian C, Schwartz ME, Glajchen N, Min AD (2000) Accuracy and significance of computed tomographic scan assessment of hepatic volume in patients undergoing liver transplantation. Transplantation 69(4):545–550CrossRefPubMed Schiano TD, Bodian C, Schwartz ME, Glajchen N, Min AD (2000) Accuracy and significance of computed tomographic scan assessment of hepatic volume in patients undergoing liver transplantation. Transplantation 69(4):545–550CrossRefPubMed
38.
Zurück zum Zitat Heimann T, Wolf I, Meinzer HP (2006) Active shape models for a fully automated 3D segmentation of the liver–an evaluation on clinical data. Med Image Comput Comput Assist Interv Int Conf Med Image Comput Comput Assist Interv 9(Pt 2):41–48 Heimann T, Wolf I, Meinzer HP (2006) Active shape models for a fully automated 3D segmentation of the liver–an evaluation on clinical data. Med Image Comput Comput Assist Interv Int Conf Med Image Comput Comput Assist Interv 9(Pt 2):41–48
40.
Zurück zum Zitat Lee J, Kim N, Lee H et al. (2007) Efficient liver segmentation exploiting level-set speed images with 2.5D shape propagation. In: Proceedings of MICCAI workshop on 3-D segmentatation in the clinic: a grand challenge, pp. 189–196. Lee J, Kim N, Lee H et al. (2007) Efficient liver segmentation exploiting level-set speed images with 2.5D shape propagation. In: Proceedings of MICCAI workshop on 3-D segmentatation in the clinic: a grand challenge, pp. 189–196.
43.
Zurück zum Zitat Lemke AJ, Brinkmann MJ, Schott T, et al. (2006) Living donor right liver lobes: preoperative CT volumetric measurement for calculation of intraoperative weight and volume. Radiology 240(3):736–742CrossRefPubMed Lemke AJ, Brinkmann MJ, Schott T, et al. (2006) Living donor right liver lobes: preoperative CT volumetric measurement for calculation of intraoperative weight and volume. Radiology 240(3):736–742CrossRefPubMed
45.
Zurück zum Zitat Reiner CS, Karlo C, Petrowsky H, et al. (2009) Preoperative liver volumetry: how does the slice thickness influence the multidetector computed tomography- and magnetic resonance-liver volume measurements? J Comput Assist Tomogr 33(3):390–397. doi:10.1097/RCT.0b013e3181806c29 CrossRefPubMed Reiner CS, Karlo C, Petrowsky H, et al. (2009) Preoperative liver volumetry: how does the slice thickness influence the multidetector computed tomography- and magnetic resonance-liver volume measurements? J Comput Assist Tomogr 33(3):390–397. doi:10.​1097/​RCT.​0b013e3181806c29​ CrossRefPubMed
46.
Zurück zum Zitat Karlo C, Reiner CS, Stolzmann P, et al. (2010) CT- and MRI-based volumetry of resected liver specimen: comparison to intraoperative volume and weight measurements and calculation of conversion factors. Eur J Radiol 75(1):e107–e111CrossRefPubMed Karlo C, Reiner CS, Stolzmann P, et al. (2010) CT- and MRI-based volumetry of resected liver specimen: comparison to intraoperative volume and weight measurements and calculation of conversion factors. Eur J Radiol 75(1):e107–e111CrossRefPubMed
Metadaten
Titel
Comparison of MRI- and CT-based semiautomated liver segmentation: a validation study
verfasst von
Akshat Gotra
Gabriel Chartrand
Kim-Nhien Vu
Franck Vandenbroucke-Menu
Karine Massicotte-Tisluck
Jacques A. de Guise
An Tang
Publikationsdatum
28.09.2016
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 2/2017
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-016-0912-7

Weitere Artikel der Ausgabe 2/2017

Abdominal Radiology 2/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.