Comparison of myocardial T1 and T2 values in 3 T with T2* in 1.5 T in patients with iron overload and controls

verfasst von: Gabriel C. Camargo, Tamara Rothstein, Flavia P. Junqueira, Elsa Fernandes, Andreas Greiser, Ralph Strecker, Viviani Pessoa, Ronaldo S. L. Lima, Ilan Gottlieb

Erschienen in: International Journal of Hematology | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Abstract

Myocardial iron quantification remains limited to 1.5 T systems with T2* measurement. The present study aimed at comparing myocardial T2* values at 1.5 T to T1 and T2 mapping at 3.0 T in patients with iron overload and healthy controls. A total of 17 normal volunteers and seven patients with a history of myocardial iron overload were prospectively enrolled. Mid-interventricular septum T2*, native T1 and T2 times were quantified on the same day, using a multi-echo gradient-echo sequence at 1.5 T and T1 and T2 mapping sequences at 3.0 T, respectively. Subjects with myocardial iron overload (T2* < 20 ms) in comparison with those without had significantly lower mean myocardial T1 times (868.9 ± 120.2 vs. 1170.3 ± 25.0 ms P = 0.005 respectively) and T2 times (34.9 ± 4.7 vs. 45.1 ± 2.0 ms P = 0.007 respectively). 3 T T1 and T2 times strongly correlated with 1.5 T, T2* times (Pearson’s r = 0.95 and 0.91 respectively). T1 and T2 measures presented less variability than T2* in inter- and intra-observer analysis. Native myocardial T1 and T2 times at 3 T correlate closely with T2* times at 1.5 T and may be useful for myocardial iron overload quantification.
Literatur
1.
Zurück zum Zitat Camaschella C, Poggiali E. Inherited disorders of iron metabolism. Curr Opin Pediatr. 2011;23:14–20.CrossRefPubMed Camaschella C, Poggiali E. Inherited disorders of iron metabolism. Curr Opin Pediatr. 2011;23:14–20.CrossRefPubMed
2.
Zurück zum Zitat Murphy CJ, Oudit GY. Iron-overload cardiomyopathy: pathophysiology, diagnosis, and treatment. J. Card. Fail. 2010;16:888–900.CrossRefPubMed Murphy CJ, Oudit GY. Iron-overload cardiomyopathy: pathophysiology, diagnosis, and treatment. J. Card. Fail. 2010;16:888–900.CrossRefPubMed
3.
Zurück zum Zitat Kolnagou A, Yazman D. Uses and limitations of serum ferritin, magnetic resonance imaging T2 and T2* in the diagnosis of iron overload and in the ferrikinetics of normalization of the iron stores in thalassemia using international committe on chelation deferiprone/deferoxamine. Hemoglobin. 2009;33:312–22.CrossRefPubMed Kolnagou A, Yazman D. Uses and limitations of serum ferritin, magnetic resonance imaging T2 and T2* in the diagnosis of iron overload and in the ferrikinetics of normalization of the iron stores in thalassemia using international committe on chelation deferiprone/deferoxamine. Hemoglobin. 2009;33:312–22.CrossRefPubMed
4.
Zurück zum Zitat Pennell DJ. T2* magnetic resonance and myocardial iron in thalassemia. Ann N Y Acad Sci. 2005;378:373–8.CrossRef Pennell DJ. T2* magnetic resonance and myocardial iron in thalassemia. Ann N Y Acad Sci. 2005;378:373–8.CrossRef
5.
Zurück zum Zitat Pennell DJ, Udelson JE, Arai AE, Bozkurt B, Cohen AR, Galanello R, et al. Cardiovascular function and treatment in β-thalassemia major: a consensus statement from the american heart association. Circulation. 2013;128:281–308.CrossRefPubMed Pennell DJ, Udelson JE, Arai AE, Bozkurt B, Cohen AR, Galanello R, et al. Cardiovascular function and treatment in β-thalassemia major: a consensus statement from the american heart association. Circulation. 2013;128:281–308.CrossRefPubMed
6.
Zurück zum Zitat Modell B, Khan M, Darlison M, Westwood MA, Ingram D, Pennell DJ. Improved survival of thalassaemia major in the UK and relation to T2* cardiovascular magnetic resonance. J Cardiovasc Magn Reson BioMed Central. 2008;10:42. Modell B, Khan M, Darlison M, Westwood MA, Ingram D, Pennell DJ. Improved survival of thalassaemia major in the UK and relation to T2* cardiovascular magnetic resonance. J Cardiovasc Magn Reson BioMed Central. 2008;10:42.
7.
Zurück zum Zitat Wood JC, Otto-Duessel M, Aguilar M, Nick H, Nelson MD, Coates TD, et al. Cardiac iron determines cardiac T2*, T2, and T1 in the gerbil model of iron cardiomyopathy. Circulation. 2005;112:535–43.CrossRefPubMedPubMedCentral Wood JC, Otto-Duessel M, Aguilar M, Nick H, Nelson MD, Coates TD, et al. Cardiac iron determines cardiac T2*, T2, and T1 in the gerbil model of iron cardiomyopathy. Circulation. 2005;112:535–43.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Carpenter J-P, He T, Kirk P, Roughton M, Anderson LJ, De Noronha SV, et al. On T2* magnetic resonance and cardiac iron. Circulation. 2011;123:1519–28.CrossRefPubMedPubMedCentral Carpenter J-P, He T, Kirk P, Roughton M, Anderson LJ, De Noronha SV, et al. On T2* magnetic resonance and cardiac iron. Circulation. 2011;123:1519–28.CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Wood J. History and current impact of cardiac magnetic resonance imaging on the management of iron overload. Circulation. Lippincott Williams & Wilkins; 2009;123:2552–61. Wood J. History and current impact of cardiac magnetic resonance imaging on the management of iron overload. Circulation. Lippincott Williams & Wilkins; 2009;123:2552–61.
10.
Zurück zum Zitat Storey P, Thompson A. R2* Imaging of Transfusional Iron Burden at 3T and Comparison with 1.5 T. J Magn Reson Imaging NIH Public Access. 2007;25:540–7.CrossRef Storey P, Thompson A. R2* Imaging of Transfusional Iron Burden at 3T and Comparison with 1.5 T. J Magn Reson Imaging NIH Public Access. 2007;25:540–7.CrossRef
11.
Zurück zum Zitat He T, Smith GC, Gatehouse PD, Mohiaddin RH, Firmin DN, Pennell DJ. On using T2 to assess extrinsic magnetic field inhomogeneity effects on T2* measurements in myocardial siderosis in thalassemia. Magn Reson Med. 2009;61:501–6.CrossRefPubMed He T, Smith GC, Gatehouse PD, Mohiaddin RH, Firmin DN, Pennell DJ. On using T2 to assess extrinsic magnetic field inhomogeneity effects on T2* measurements in myocardial siderosis in thalassemia. Magn Reson Med. 2009;61:501–6.CrossRefPubMed
12.
Zurück zum Zitat Oshinski JN, Delfino JG, Sharma P, Gharib AM, Pettigrew RI. Cardiovascular magnetic resonance at 3.0 T: current state of the art. J Cardiovasc Magn Reson BioMed Central Ltd. 2010;12:55. Oshinski JN, Delfino JG, Sharma P, Gharib AM, Pettigrew RI. Cardiovascular magnetic resonance at 3.0 T: current state of the art. J Cardiovasc Magn Reson BioMed Central Ltd. 2010;12:55.
13.
Zurück zum Zitat Messroghli DR, Greiser A, Fröhlich M, Dietz R, Schulz-Menger J. Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart. J Magn Reson Imaging. 2007;26:1081–6.CrossRefPubMed Messroghli DR, Greiser A, Fröhlich M, Dietz R, Schulz-Menger J. Optimization and validation of a fully-integrated pulse sequence for modified look-locker inversion-recovery (MOLLI) T1 mapping of the heart. J Magn Reson Imaging. 2007;26:1081–6.CrossRefPubMed
14.
Zurück zum Zitat Messroghli DR, Radjenovic A, Kozerke S, Higgins DM, Sivananthan MU, Ridgway JP. Modified look-locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magn Reson Med. 2004;52:141–6.CrossRefPubMed Messroghli DR, Radjenovic A, Kozerke S, Higgins DM, Sivananthan MU, Ridgway JP. Modified look-locker inversion recovery (MOLLI) for high-resolution T1 mapping of the heart. Magn Reson Med. 2004;52:141–6.CrossRefPubMed
15.
Zurück zum Zitat Giri S, Shah S, Xue H, Chung Y-C, Pennell ML, Guehring J, et al. Myocardial T2 mapping with respiratory navigator and automatic nonrigid motion correction. Magn Reson Med. 2012;68:1570–8.CrossRefPubMedPubMedCentral Giri S, Shah S, Xue H, Chung Y-C, Pennell ML, Guehring J, et al. Myocardial T2 mapping with respiratory navigator and automatic nonrigid motion correction. Magn Reson Med. 2012;68:1570–8.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Henninger B, Kremser C, Rauch S, Eder R, Zoller H, Finkenstedt A, et al. Evaluation of MR imaging with T1 and T2* mapping for the determination of hepatic iron overload. Eur Radiol. 2012;22:2478–86.CrossRefPubMed Henninger B, Kremser C, Rauch S, Eder R, Zoller H, Finkenstedt A, et al. Evaluation of MR imaging with T1 and T2* mapping for the determination of hepatic iron overload. Eur Radiol. 2012;22:2478–86.CrossRefPubMed
17.
Zurück zum Zitat Feng Y, He T, Carpenter J-P, Jabbour A, Alam MH, Gatehouse PD, et al. In vivo comparison of myocardial T1 with T2 and T2* in thalassaemia major. J Magn Reson Imaging. 2013;38:588–93.CrossRefPubMed Feng Y, He T, Carpenter J-P, Jabbour A, Alam MH, Gatehouse PD, et al. In vivo comparison of myocardial T1 with T2 and T2* in thalassaemia major. J Magn Reson Imaging. 2013;38:588–93.CrossRefPubMed
18.
Zurück zum Zitat Sado D, White SK, Piechnik SK, Banypersad SM, Treibel TA, Fontana M, et al. Native T1 lowering in iron overload and Anderson Fabry disease ; a novel and early marker of disease. J Cardiovasc Magn Reson BioMed Central Ltd. 2013;15(Suppl1):O71 (Abstract). Sado D, White SK, Piechnik SK, Banypersad SM, Treibel TA, Fontana M, et al. Native T1 lowering in iron overload and Anderson Fabry disease ; a novel and early marker of disease. J Cardiovasc Magn Reson BioMed Central Ltd. 2013;15(Suppl1):O71 (Abstract).
19.
Zurück zum Zitat Lee JJ, Liu S, Nacif MS, Ugander M, Han J, Kawel N, et al. Myocardial T1 and extracellular volume fraction mapping at 3 tesla. J Cardiovasc Magn Reson. 2011;13:75.CrossRefPubMedPubMedCentral Lee JJ, Liu S, Nacif MS, Ugander M, Han J, Kawel N, et al. Myocardial T1 and extracellular volume fraction mapping at 3 tesla. J Cardiovasc Magn Reson. 2011;13:75.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Piechnik S, Ferreira V, Armellina E, Cochlin L, Greiser A, Neubauer S, et al. Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. J Cardiovasc Magn Reson. 2010;1:11. Piechnik S, Ferreira V, Armellina E, Cochlin L, Greiser A, Neubauer S, et al. Shortened Modified Look-Locker Inversion recovery (ShMOLLI) for clinical myocardial T1-mapping at 1.5 and 3 T within a 9 heartbeat breathhold. J Cardiovasc Magn Reson. 2010;1:11.
21.
Zurück zum Zitat Westwood Mark. Lisa J Anderson, David N Firmin, Peter D Gatehouse, Clare C Charrier, Beatrix Wonke DJP. A single breath-hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload. J Magn Reson Imaging. 2003;18:33–9.CrossRefPubMed Westwood Mark. Lisa J Anderson, David N Firmin, Peter D Gatehouse, Clare C Charrier, Beatrix Wonke DJP. A single breath-hold multiecho T2* cardiovascular magnetic resonance technique for diagnosis of myocardial iron overload. J Magn Reson Imaging. 2003;18:33–9.CrossRefPubMed
23.
Zurück zum Zitat Kellman P, Chefd’hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting. Magn Reson Med. 2009;62:1557–64.CrossRefPubMedPubMedCentral Kellman P, Chefd’hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting. Magn Reson Med. 2009;62:1557–64.CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat He T, Gatehouse PD, Smith GC, Mohiaddin RH, Pennell DJ, Firmin DN. Myocardial T2* measurements in iron-overloaded thalassemia: an in vivo study to investigate optimal methods of quantification. Magn Reson Med. 2008;60:1082–9.CrossRefPubMedPubMedCentral He T, Gatehouse PD, Smith GC, Mohiaddin RH, Pennell DJ, Firmin DN. Myocardial T2* measurements in iron-overloaded thalassemia: an in vivo study to investigate optimal methods of quantification. Magn Reson Med. 2008;60:1082–9.CrossRefPubMedPubMedCentral
25.
Zurück zum Zitat Hardy P, Henkelman R. Transverse relaxation rate enhancement caused by magnetic particulates. Magn Reson Imaging. 1989;7:265–75.CrossRefPubMed Hardy P, Henkelman R. Transverse relaxation rate enhancement caused by magnetic particulates. Magn Reson Imaging. 1989;7:265–75.CrossRefPubMed
26.
Zurück zum Zitat Tanimoto a, Oshio K, Suematsu M, Pouliquen D, Stark DD. Relaxation effects of clustered particles. J. Magn. Reson. Imaging. 2001;14:72–7. Tanimoto a, Oshio K, Suematsu M, Pouliquen D, Stark DD. Relaxation effects of clustered particles. J. Magn. Reson. Imaging. 2001;14:72–7.
27.
Zurück zum Zitat Gossuin Y, Burtea C, Monseux A, Toubeau G, Roch A, Muller RN, et al. Ferritin-induced relaxation in tissues: an in vitro study. J Magn Reson Imaging. 2004;20:690–6.CrossRefPubMed Gossuin Y, Burtea C, Monseux A, Toubeau G, Roch A, Muller RN, et al. Ferritin-induced relaxation in tissues: an in vitro study. J Magn Reson Imaging. 2004;20:690–6.CrossRefPubMed
28.
Zurück zum Zitat Anderson LJ, Holden S, Davis B, Prescott E, Charrier CC, Bunce NH, et al. Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur. Heart J. W B Saunders Co Ltd; 2001;22:2171–9. Anderson LJ, Holden S, Davis B, Prescott E, Charrier CC, Bunce NH, et al. Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur. Heart J. W B Saunders Co Ltd; 2001;22:2171–9.
29.
Zurück zum Zitat Ibrahim E-SH, Rana FN, Johnson KR, White RD. Assessment of cardiac iron deposition in sickle cell disease using 3.0 Tesla cardiovascular magnetic resonance. Hemoglobin. 2012;36:343–61. Ibrahim E-SH, Rana FN, Johnson KR, White RD. Assessment of cardiac iron deposition in sickle cell disease using 3.0 Tesla cardiovascular magnetic resonance. Hemoglobin. 2012;36:343–61.
30.
Zurück zum Zitat Liu S, Han J, Nacif M, Jones J, Kawel N, Kellman P, et al. Diffuse myocardial fibrosis evaluation using cardiac magnetic resonance T1 mapping: sample size considerations for clinical trials. J Cardiovasc Magn Reson. 2012;14:90.CrossRefPubMedPubMedCentral Liu S, Han J, Nacif M, Jones J, Kawel N, Kellman P, et al. Diffuse myocardial fibrosis evaluation using cardiac magnetic resonance T1 mapping: sample size considerations for clinical trials. J Cardiovasc Magn Reson. 2012;14:90.CrossRefPubMedPubMedCentral
31.
Zurück zum Zitat Guo H, Au W, Cheung J. Myocardial T2 Quantitation in Patients With Iron Overload at 3 Tesla. J Magn NIH Public Access. 2009;22:4109. Guo H, Au W, Cheung J. Myocardial T2 Quantitation in Patients With Iron Overload at 3 Tesla. J Magn NIH Public Access. 2009;22:4109.
33.
Zurück zum Zitat Chu WCW, Au WY, Lam WWM. MRI of cardiac iron overload. J Magn Reson Imaging. 2012;36:1052–9.CrossRefPubMed Chu WCW, Au WY, Lam WWM. MRI of cardiac iron overload. J Magn Reson Imaging. 2012;36:1052–9.CrossRefPubMed
34.
Zurück zum Zitat Wu E, Kim D, Tosti C. Magnetic resonance assessment of iron overload by separate measurement of tissue ferritin and hemosiderin iron. Ann New Acad Sci NIH Public Access. 2010;1202:115–22.CrossRef Wu E, Kim D, Tosti C. Magnetic resonance assessment of iron overload by separate measurement of tissue ferritin and hemosiderin iron. Ann New Acad Sci NIH Public Access. 2010;1202:115–22.CrossRef
35.
Zurück zum Zitat Cheung J, Au W, Ha S. Reduced Transverse Relaxation Rate (RR2) for Improved Sensitivity in Monitoring Myocardial Iron in Thalassemia. J Magn Reson Imaging NIH Public Access. 2011;33:1510–6.CrossRef Cheung J, Au W, Ha S. Reduced Transverse Relaxation Rate (RR2) for Improved Sensitivity in Monitoring Myocardial Iron in Thalassemia. J Magn Reson Imaging NIH Public Access. 2011;33:1510–6.CrossRef
36.
Zurück zum Zitat Carpenter JP, Pennell DJ. Role of T2* magnetic resonance in monitoring iron chelation therapy. Acta Haematol. 2009;122:146–54.CrossRefPubMed Carpenter JP, Pennell DJ. Role of T2* magnetic resonance in monitoring iron chelation therapy. Acta Haematol. 2009;122:146–54.CrossRefPubMed
37.
Zurück zum Zitat Kirk P, Carpenter JP, Tanner M a, Pennell DJ. Low prevalence of fibrosis in thalassemia major assessed by late gadolinium enhancement cardiovascular magnetic resonance. J Cardiovasc Magn Reson BioMed Central Ltd; 2011;13:8. Kirk P, Carpenter JP, Tanner M a, Pennell DJ. Low prevalence of fibrosis in thalassemia major assessed by late gadolinium enhancement cardiovascular magnetic resonance. J Cardiovasc Magn Reson BioMed Central Ltd; 2011;13:8.
38.
Zurück zum Zitat Marks B, Mitchell DG, Simelaro JP. Breath-holding in healthy and pulmonary-compromised populations: effects of hyperventilation and oxygen inspiration. J Magn Reson Imaging. 1997;7:595–7.CrossRefPubMed Marks B, Mitchell DG, Simelaro JP. Breath-holding in healthy and pulmonary-compromised populations: effects of hyperventilation and oxygen inspiration. J Magn Reson Imaging. 1997;7:595–7.CrossRefPubMed
39.
Zurück zum Zitat Robson MD, Piechnik SK, Tunnicliffe EM, Neubauer S. T1 measurements in the human myocardium: the effects of magnetization transfer on the SASHA and MOLLI sequences. Magn Reson Med. 2013;00:1–7. Robson MD, Piechnik SK, Tunnicliffe EM, Neubauer S. T1 measurements in the human myocardium: the effects of magnetization transfer on the SASHA and MOLLI sequences. Magn Reson Med. 2013;00:1–7.
40.
Zurück zum Zitat Chow K, Flewitt J a, Green JD, Pagano JJ, Friedrich MG, Thompson RB. Saturation recovery single-shot acquisition (SASHA) for myocardial T1 mapping. Magn Reson Med 2013;00:1–14. Chow K, Flewitt J a, Green JD, Pagano JJ, Friedrich MG, Thompson RB. Saturation recovery single-shot acquisition (SASHA) for myocardial T1 mapping. Magn Reson Med 2013;00:1–14.
Metadaten
Titel
Comparison of myocardial T1 and T2 values in 3 T with T2* in 1.5 T in patients with iron overload and controls
verfasst von
Gabriel C. Camargo
Tamara Rothstein
Flavia P. Junqueira
Elsa Fernandes
Andreas Greiser
Ralph Strecker
Viviani Pessoa
Ronaldo S. L. Lima
Ilan Gottlieb
Publikationsdatum
12.02.2016
Verlag
Springer Japan
Erschienen in
International Journal of Hematology / Ausgabe 5/2016
Print ISSN: 0925-5710
Elektronische ISSN: 1865-3774
DOI
https://doi.org/10.1007/s12185-016-1950-1

Weitere Artikel der Ausgabe 5/2016

International Journal of Hematology 5/2016 Zur Ausgabe

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.