Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 7/2019

08.03.2019 | Original Paper

Comparison of sequential and high-pitch-spiral coronary CT-angiography: image quality and radiation exposure

verfasst von: D. Seppelt, C. Kolb, J. P. Kühn, U. Speiser, C. G. Radosa, S. Hoberück, R. T. Hoffmann, I. Platzek

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 7/2019

Einloggen, um Zugang zu erhalten

Abstract

New protocols for coronary computed tomography angiography (CCTA) could lower the radiation dose for patients but influence the image quality. To compare image quality and radiation exposure in step-and-shoot CCTA and high-pitch spiral CCTA. Fifty-nine pairs of patients matched for weight, height, sex and heart rate were included in this study (74 m, 44 f, average age 60 years, age range 29–94 years). Step-and-shoot CCTA and high-pitch spiral CCTA was performed on a third generation dual-source CT in equally sized patient groups. The signal-to-noise ratio (SNR) in the ascending aorta and the coronary arteries were determined for each dataset. Image quality was rated using a five-point scale. We used the t-test for paired samples to compare SNR and effective dose, and the Wilcoxon test to compare image quality scores. Mean effective dose for the step-and-shoot protocol (4.15 ± 3.07 mSv) was significantly higher in comparison to the high-pitch spiral protocol (1.2 ± 0.69 mSv; p < 0.0001). Mean SNR was higher with the step-and-shoot protocol compared to the high-pitch spiral protocol in the aorta, in the left main and peripheral coronary arteries (p < 0.01), in the proximal right coronary artery (p = 0.027). Image quality scores were significantly better for the step-and-shoot protocol (p = 0.0003). Step-and-shoot CCTA has significantly better SNR and overall image quality compared to high-pitch spiral CCTA, but with a mean effective dose more than thrice as high.
Literatur
1.
Zurück zum Zitat Roth GA, Huffman MD, Moran AE, Feigin V, Mensah GA, Naghavi M et al (2015) Global and regional patterns in cardiovascular mortality from 1990 to 2013. Circulation 132:1667–1678CrossRefPubMed Roth GA, Huffman MD, Moran AE, Feigin V, Mensah GA, Naghavi M et al (2015) Global and regional patterns in cardiovascular mortality from 1990 to 2013. Circulation 132:1667–1678CrossRefPubMed
2.
Zurück zum Zitat Bhatnagar P, Wickramasinghe K, Williams J, Rayner M, Townsend N (2015) The epidemiology of cardiovascular disease in the UK 2014. Heart 101:1182–1189CrossRefPubMed Bhatnagar P, Wickramasinghe K, Williams J, Rayner M, Townsend N (2015) The epidemiology of cardiovascular disease in the UK 2014. Heart 101:1182–1189CrossRefPubMed
3.
Zurück zum Zitat Go AS, Mozaffarian D, Roger VL, Benjamin EJ, Berry JD, Blaha MJ et al (2014) Heart disease and stroke statistics—2014 update: a report from the American Heart Association. Circulation 129:e28–e292CrossRefPubMed Go AS, Mozaffarian D, Roger VL, Benjamin EJ, Berry JD, Blaha MJ et al (2014) Heart disease and stroke statistics—2014 update: a report from the American Heart Association. Circulation 129:e28–e292CrossRefPubMed
4.
Zurück zum Zitat Patel MR, Peterson ED, Dai D, Brennan JM, Redberg RF, Anderson HV et al (2010) Low diagnostic yield of elective coronary angiography. N Engl J Med 362:886–895CrossRefPubMedPubMedCentral Patel MR, Peterson ED, Dai D, Brennan JM, Redberg RF, Anderson HV et al (2010) Low diagnostic yield of elective coronary angiography. N Engl J Med 362:886–895CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Dewey M, Zimmermann E, Deissenrieder F, Laule M, Dübel H-P, Schlattmann P et al (2009) Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation 120:867–875CrossRefPubMed Dewey M, Zimmermann E, Deissenrieder F, Laule M, Dübel H-P, Schlattmann P et al (2009) Noninvasive coronary angiography by 320-row computed tomography with lower radiation exposure and maintained diagnostic accuracy: comparison of results with cardiac catheterization in a head-to-head pilot investigation. Circulation 120:867–875CrossRefPubMed
6.
Zurück zum Zitat Hsieh J, Londt J, Vass M, Li J, Tang X, Okerlund D (2006) Step-and-shoot data acquisition and reconstruction for cardiac X-ray computed tomography. Med Phys 33:4236–4248CrossRefPubMed Hsieh J, Londt J, Vass M, Li J, Tang X, Okerlund D (2006) Step-and-shoot data acquisition and reconstruction for cardiac X-ray computed tomography. Med Phys 33:4236–4248CrossRefPubMed
7.
Zurück zum Zitat Earls JP (2009) How to use a prospective gated technique for cardiac CT. J Cardiovasc Comput Tomogr 3:45–51CrossRefPubMed Earls JP (2009) How to use a prospective gated technique for cardiac CT. J Cardiovasc Comput Tomogr 3:45–51CrossRefPubMed
8.
Zurück zum Zitat Baek S, Park SH, Won E, Park YR, Kim HJ (2015) Propensity score matching: a conceptual review for radiology researchers. Korean J Radiol 16:286–296CrossRefPubMedPubMedCentral Baek S, Park SH, Won E, Park YR, Kim HJ (2015) Propensity score matching: a conceptual review for radiology researchers. Korean J Radiol 16:286–296CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Pannu HK, Alvarez W, Fishman EK (2006) Beta-blockers for cardiac CT: a primer for the radiologist. Am J Roentgenol 186:S341–S345CrossRef Pannu HK, Alvarez W, Fishman EK (2006) Beta-blockers for cardiac CT: a primer for the radiologist. Am J Roentgenol 186:S341–S345CrossRef
10.
Zurück zum Zitat Raju VM, Gosling OE, Morgan-Hughes G, Colliver RJ, Iyengar S, Dissanayake P et al (2014) High-dose intravenous metoprolol usage for reducing heart rate at CT coronary angiography: efficacy and safety. Clin Radiol 69:739–744CrossRefPubMed Raju VM, Gosling OE, Morgan-Hughes G, Colliver RJ, Iyengar S, Dissanayake P et al (2014) High-dose intravenous metoprolol usage for reducing heart rate at CT coronary angiography: efficacy and safety. Clin Radiol 69:739–744CrossRefPubMed
11.
Zurück zum Zitat Cademartiri F, Nieman K, van der Lugt A, Raaijmakers RH, Mollet N, Pattynama PMT et al (2004) Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology 233:817–823CrossRefPubMed Cademartiri F, Nieman K, van der Lugt A, Raaijmakers RH, Mollet N, Pattynama PMT et al (2004) Intravenous contrast material administration at 16-detector row helical CT coronary angiography: test bolus versus bolus-tracking technique. Radiology 233:817–823CrossRefPubMed
12.
Zurück zum Zitat Sun K, Liu G-R, Li Y-C, Han R-J, Cui L-F, Ma L-J et al (2013) Intravenous contrast material administration at high-pitch dual-source CT coronary angiography: bolus-tracking technique with shortened time of respiratory instruction versus test bolus technique. Chin Med Sci J 27:225–231CrossRefPubMed Sun K, Liu G-R, Li Y-C, Han R-J, Cui L-F, Ma L-J et al (2013) Intravenous contrast material administration at high-pitch dual-source CT coronary angiography: bolus-tracking technique with shortened time of respiratory instruction versus test bolus technique. Chin Med Sci J 27:225–231CrossRefPubMed
15.
Zurück zum Zitat Cerqueira MD (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–542CrossRefPubMed Cerqueira MD (2002) Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: a statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association. Circulation 105:539–542CrossRefPubMed
16.
Zurück zum Zitat Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biom Int Biom Soc 33:159 Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biom Int Biom Soc 33:159
19.
Zurück zum Zitat Armstrong RA (2014) When to use the Bonferroni correction. Ophthalmic Physiol Opt 34:502–508CrossRefPubMed Armstrong RA (2014) When to use the Bonferroni correction. Ophthalmic Physiol Opt 34:502–508CrossRefPubMed
20.
Zurück zum Zitat Curtin F, Schulz P (1998) Multiple correlations and Bonferroni’s correction. Biol Psychiatry 44:775–777CrossRefPubMed Curtin F, Schulz P (1998) Multiple correlations and Bonferroni’s correction. Biol Psychiatry 44:775–777CrossRefPubMed
21.
Zurück zum Zitat Smettei OA, Sayed S, Al Habib MA, Alharbi F, Abazid RM (2018) Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: comparison of image quality and patient radiation exposure. J Saudi Heart Assoc 30:165–171CrossRefPubMed Smettei OA, Sayed S, Al Habib MA, Alharbi F, Abazid RM (2018) Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: comparison of image quality and patient radiation exposure. J Saudi Heart Assoc 30:165–171CrossRefPubMed
22.
Zurück zum Zitat Ghadri JR, Küest SM, Goetti R, Fiechter M, Pazhenkottil AP, Nkoulou RN et al (2012) Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition. Int J Cardiovasc Imaging 28:1217–1225. https://doi.org/10.1007/s10554-011-9921-3 CrossRefPubMed Ghadri JR, Küest SM, Goetti R, Fiechter M, Pazhenkottil AP, Nkoulou RN et al (2012) Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition. Int J Cardiovasc Imaging 28:1217–1225. https://​doi.​org/​10.​1007/​s10554-011-9921-3 CrossRefPubMed
23.
Zurück zum Zitat Wang W, Zhao YE, Qi L, Li X, Zhou CS, Zhang LJ et al (2017) Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: an intraindividual comparison with sequential scanning at 120 kVp with 60 mL contrast agent. Eur J Radiol 90:97–105CrossRefPubMed Wang W, Zhao YE, Qi L, Li X, Zhou CS, Zhang LJ et al (2017) Prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp with 30 mL contrast agent: an intraindividual comparison with sequential scanning at 120 kVp with 60 mL contrast agent. Eur J Radiol 90:97–105CrossRefPubMed
26.
Zurück zum Zitat Gebhard C, Fuchs TA, Stehli J, Gransar H, Berman DS, Budoff MJ et al (2015) Coronary dominance and prognosis in patients undergoing coronary computed tomographic angiography: results from the CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: an international multicenter) registry. Eur Heart J Cardiovasc Imaging 16:853–862CrossRefPubMedPubMedCentral Gebhard C, Fuchs TA, Stehli J, Gransar H, Berman DS, Budoff MJ et al (2015) Coronary dominance and prognosis in patients undergoing coronary computed tomographic angiography: results from the CONFIRM (COronary CT Angiography EvaluatioN For Clinical Outcomes: an international multicenter) registry. Eur Heart J Cardiovasc Imaging 16:853–862CrossRefPubMedPubMedCentral
27.
Zurück zum Zitat Sakamoto S, Takahashi S, Coskun AU, Papafaklis MI, Takahashi A, Saito S et al (2013) Relation of distribution of coronary blood flow volume to coronary artery dominance. Am J Cardiol 111:1420–1424CrossRefPubMed Sakamoto S, Takahashi S, Coskun AU, Papafaklis MI, Takahashi A, Saito S et al (2013) Relation of distribution of coronary blood flow volume to coronary artery dominance. Am J Cardiol 111:1420–1424CrossRefPubMed
Metadaten
Titel
Comparison of sequential and high-pitch-spiral coronary CT-angiography: image quality and radiation exposure
verfasst von
D. Seppelt
C. Kolb
J. P. Kühn
U. Speiser
C. G. Radosa
S. Hoberück
R. T. Hoffmann
I. Platzek
Publikationsdatum
08.03.2019
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 7/2019
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-019-01568-y

Weitere Artikel der Ausgabe 7/2019

The International Journal of Cardiovascular Imaging 7/2019 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.