Comparison of swept-source OCTA quantitative parameters between balanced salt solution and air tamponade after pars plana vitrectomy with peeling of idiopathic epiretinal membrane
- 08.10.2024
- case series
- Verfasst von
- Stefan Kickinger
- Maximilian Gabriel
- Anna-Maria Haas
- Martin Stattin
- Daniel Ahmed-Balestra
- Michael Jacob
- Alexandra Graf
- Reinhard Angermann
- Katharina Krepler
- Siamak Ansari-Shahrezaei
- Erschienen in
- Spektrum der Augenheilkunde | Ausgabe 5/2025
Summary
Background
To investigate potential differences in quantitative optical coherence tomography angiography (OCTA) parameters between balanced salt solution and air tamponade in eyes undergoing pars plana vitrectomy for idiopathic epiretinal membrane.
Materials and methods
This retrospective pilot study included 18 eyes, of which 10 were assigned to fluid and eight to the air group at the surgeon’s discretion. The OCTA imaging studies were acquired using the Topcon DRI OCT Triton Plus swept-source device before as well as 2 weeks and 2 months after surgery. The time course of foveal avascular zone (FAZ) area, perimeter and circularity as well as vessel density were compared between groups using linear mixed models.
Results
No significant difference in the change of FAZ parameters between time points or between the two groups was found. Additionally, no significant change over the time points across both groups was found. The exception is the perimeter of the deep capillary plexus, where a significant decrease from the preoperative to the 1st postoperative visit was observed (p = 0.005). Regarding vessel density, no significant difference in the change between time points between the two groups was found. In the overall study population, significant changes in the parafoveal area could be observed. The superficial capillary plexus, choriocapillary and full thickness of the retina showed a significant decrease from baseline to the 1st as well as to the 2nd postoperative visit (p = 0.001–0.016).
Conclusions
Although there were some statistically significant changes in the overall patient population, the air and fluid group remained equal regarding OCTA parameters.
Anzeige
- Titel
- Comparison of swept-source OCTA quantitative parameters between balanced salt solution and air tamponade after pars plana vitrectomy with peeling of idiopathic epiretinal membrane
- Verfasst von
-
Stefan Kickinger
Maximilian Gabriel
Anna-Maria Haas
Martin Stattin
Daniel Ahmed-Balestra
Michael Jacob
Alexandra Graf
Reinhard Angermann
Katharina Krepler
Siamak Ansari-Shahrezaei
- Publikationsdatum
- 08.10.2024
- Verlag
- Springer Vienna
- Erschienen in
-
Spektrum der Augenheilkunde / Ausgabe 5/2025
Print ISSN: 0930-4282
Elektronische ISSN: 1613-7523 - DOI
- https://doi.org/10.1007/s00717-024-00584-1
Dieser Inhalt ist nur sichtbar, wenn du eingeloggt bist und die entsprechende Berechtigung hast.