Background

This study aimed to demonstrate the noninferior efficacy of TachoSil vs. TachoComb in Japanese patients undergoing liver resection and to assess the safety of TachoSil vs. TachoComb in these patients.

Methods

This randomized, double-blind, noninferiority study (JapicCTI-090684) involved participants scheduled for liver resection/living donors (age ≥ 20 years). TachoSil or TachoComb (1:1 allocation ratio) was applied to control persistent exudative bleeding after primary hemostasis during liver resection/removal for donation. The primary outcome was hemostasis 5 min after study treatment application. The 95% confidence interval (CI) for the difference in the proportion of participants with hemostasis 5 min after application of TachoSil/TachoComb was determined; noninferiority of TachoSil was indicated if the lower limit of the CI was ≥−14%. Adverse events (AEs) were recorded.

Results

All participants in the efficacy analysis (TachoSil: 54/54, 100%; TachoComb: 54/54, 100%) achieved hemostasis 5 min after study treatment application. Therefore, TachoSil was noninferior to TachoComb. All participants experienced ≥1 AE; however, none discontinued because of an AE. Most (≥97.8%) AEs were mild or moderate in severity.

Conclusions

These findings confirm the safety profile and noninferior hemostatic efficacy of TachoSil compared with TachoComb.

Introduction

Hemostasis during liver resection is a critical determinant of surgical success. Indeed, the volume of blood loss during liver surgery is an established predictor of morbidity and mortality [13]. Of note, the management of hemorrhage during liver resection can be particularly challenging compared with other types of surgery because the hepatosinusoidal structure lacks smooth muscle and thus the capacity to vasoconstrict [4]. As a consequence, a variety of different approaches may be used to manage bleeding during liver resection. Major bleeding (strong and/or pulsating) from identifiable vessels is initially managed by primary surgical methods (i.e., sutures, stapling ligatures, argon beam coagulation, and electrocautery) and then secondary hemostatic agents as necessary [5, 6]. Diffuse bleeding may be managed by argon beam coagulation, electrocautery, and/or hemostatic agents, including collagen-based sealants, synthetic glues, and fibrin sealants [58]. Of these hemostatic agents, fibrin sealants have been increasingly used for hemostasis during liver resection [9], in which they may be used to control persistent bleeding (after primary surgical management) and/or diffuse bleeding.
TachoComb® and TachoSil® are widely used fibrin sealants for tissue adhesion/closure during different types of surgery, including liver, lung, cardiovascular, gynecological, and urological. TachoComb comprises a collagen patch coated with human fibrinogen and bovine thrombin and aprotinin. This product version has been marketed and widely used in Japan since 1999. The newer product version, TachoSil, is currently marketed in more than 50 countries worldwide, and it comprises a collagen patch coated with human fibrinogen and human thrombin. TachoSil was developed after TachoComb to avoid potential immunogenic effects of bovine thrombin [10] and anaphylaxis caused by bovine aprotinin with repeated use [11, 12], and to negate the theoretical risk of horizontal disease transfer (bovine to human), e.g., by prions causing variant Creutzfeldt–Jakob disease. Preclinical testing in pigs demonstrated that there was no difference between TachoSil and TachoComb in primary hemostasis and that aprotinin was not required for effective hemostasis [13]. Subsequent clinical studies [1416] carried out in Europe demonstrated that TachoSil provides effective hemostasis during liver resection and has an acceptable safety and tolerability profile. To date, however, no comparison of the efficacy and safety of the two product versions has been published to demonstrate if the exclusion of aprotinin has an impact on clinical outcomes. Likewise, the hemostatic efficacy of TachoSil has not previously been investigated in Asians (including Japanese) with their different coagulation profile compared with Caucasians [17].
Accordingly, the aims of this study were to demonstrate noninferiority in efficacy of TachoSil compared with TachoComb in Japanese patients undergoing liver resection and to assess and compare the safety of the two products in these patients.

Methods

Study design

This was a multicenter, randomized, double-blind, noninferiority (TachoSil vs. TachoComb) study carried out at 11 sites in Japan from 18th April 2008 to 19th August 2009. The trial was registered in the Japan Pharmaceutical Information Center Clinical Trial Information database (JapicCTI-090684).
The study protocol was reviewed and approved by the Institutional Review Board at each study site. The study was carried out in accordance with Good Clinical Practice (GCP), based on the ethical principles outlined in the Declaration of Helsinki and the International Conference on Harmonization-GCP Guideline, and all applicable local Japanese laws and regulations. All participants provided written informed consent.

Study population

Patients scheduled for elective liver resection (at least segmental, anatomical, or non-anatomical) and living donors were considered for inclusion in the study if they were aged ≥20 years at the time of informed consent.
Patients and living donors were excluded from the study if they had a Child–Pugh Classification of C; had a history of hypersensitivity to any of the ingredients of the investigational products, or to bovine blood-derived, bovine lung-derived, or equine blood-derived preparations; had a history of TachoComb use; were females who were pregnant, lactating, suspected of being pregnant, or who planned to become pregnant during the study period; had participated in any other clinical study within 180 days before providing informed consent; or were judged by the investigator as not suitable to participate in the study.

Randomization and treatment protocol

Prior to surgery, participants were randomly allocated (1:1 ratio) to TachoSil or TachoComb using a central allocation system. Randomization was stratified by study site, Child–Pugh classification (A or B), and platelet count (<100,000 or ≥100,000/μL). Intra-operatively, patients with severe surgical complications and patients with persistent bleeding after completion of the primary hemostatic procedures were excluded from the study.
TachoSil and TachoComb were provided (Nycomed, Zurich, Switzerland [now part of Takeda Pharmaceutical Company Ltd]) in the form of identical 9.5 × 4.8 cm equine collagen patches of a 0.5 cm thick spongy material with a dry yellow coating of active ingredients on one side. Active ingredients in the TachoSil patches were human fibrinogen (5.5 mg/cm2) and human thrombin (1.38 IU/cm2). Active ingredients in the TachoComb patches were human fibrinogen (5.5 mg/cm2), bovine thrombin (1.38 IU/cm2), and bovine aprotinin (128 IU/cm2). The two study treatments were indistinguishable in their appearance and physical characteristics.
Study treatment was applied at the discretion of the investigator/subinvestigator to control persistent bleeding after primary hemostasis during liver resection or liver removal for donation. Before application, the wound site was cleansed of blood and body fluid. The patch was cut to the required dimensions and applied in dry form, or moistened with physiological saline just before application. The active side was applied to the bleeding wound site and held against the site with gentle pressure for 5 min.
To prevent potential confounding of the efficacy and safety evaluations, participants were prohibited from taking the following concomitant medications from 2 days before study treatment until day 28 after study treatment: tissue sealants containing fibrinogen, collagen preparations, oxidized cellulose preparations, local hemostatic agents, whole blood and platelet preparations, fresh frozen plasma, procoagulants, antifibrinolytic agents, aprotinin preparations, and other investigational drugs or medical devices.

Outcome measures

The primary efficacy outcome was hemostasis 5 min after the application of study treatment, which was assessed at the site where study treatment was first applied. Blood flow occlusion was temporarily released, if clamping was used, and the site was visually inspected by the investigator/subinvestigator. Hemostasis was defined as being achieved when other hemostatic treatment was not required. If hemostasis was not obtained 5 min after application, other (nonstudy) treatments were used to control bleeding from the wound.
Adverse events (AEs) were recorded from the time of informed consent until day 28 after treatment and were defined as any unfavorable medical occurrence or worsening of subjective symptoms/objective findings, worsening of underlying diseases and complications, or clinically significant abnormal laboratory values. Adverse events were coded according to MedDRA, version 11.0.
Serological tests for hepatitis B and C virus (HBV and HCV) and human immunodeficiency virus (HIV) were performed the day before study treatment and at day 28.

Statistical analysis

Based on the results from European clinical studies of patients undergoing liver resection, 95% of Japanese participants were expected to achieve hemostasis at 5 min. A sample size of 100 participants (50 per study group) was determined to provide 90% power at a noninferiority margin of 0.14.
The efficacy analysis population for demonstrating non-inferiority was the per protocol set and included all enrolled participants who received the allocated study treatment and from whom any data was collected (full analysis set), in accordance with the intention-to-treat principle [18]. The safety analysis population included all enrolled participants who received the allocated study treatment and provided any data.
The primary efficacy analysis, designed to demonstrate noninferiority of TachoSil compared with TachoComb, was the 95% confidence interval (CI) for the difference between TachoSil and TachoComb in the proportion of participants with hemostasis 5 min after application of TachoSil or TachoComb. Noninferiority of TachoSil was considered to be demonstrated if the lower limit of the 95% CI was greater than −14%. The 95% CI for the proportion of participants with hemostasis at 5 min in each group was also calculated using the score method by Wilson [19]. The difference in the proportion of participants with hemostasis at 5 min between the TachoSil and TachoComb groups was compared using Fisher’s exact test.
Safety analysis comprised the number of AEs, the number of participants who experienced AEs, and the number of participants who were HBV, HCV, and HIV positive at day 28.

Results

Disposition of participants

A total of 130 participants were randomized to treatment, 64 to TachoSil and 66 to TachoComb (Fig. 1). Of the 64 participants randomized to TachoSil, 55 (85.9%) received study treatment, two (3.1%) discontinued from study participation, and 53 (82.8%) completed the study. Of the 66 participants randomized to TachoComb, 56 (84.8%) received study treatment, two (3.0%) discontinued from study participation, and 53 (80.3%) completed the study (note: one participant in this group completed the study, but did not complete the day 28 examination). Except for one participant in the TachoSil group who died due to intra-abdominal hemorrhage, all other participants who were discontinued had prohibited concomitant medications.
The efficacy analysis population included 54 participants in both study groups. The safety analysis population included 55 participants in the TachoSil group and 56 participants in the TachoComb group.

Demographic, baseline, and surgical characteristics

Demographic and baseline characteristics were generally similar between study groups (Table 1), although there were more alcohol users (37.0 vs. 14.8%) and fewer patients undergoing surgery due to liver donation (22.1 vs. 3.7%) in the TachoSil group compared to the TachoComb treatment group. Overall, surgical characteristics were balanced between TachoSil and TachoComb treatment groups, respectively, with small differences in the use of drip bipolar (14.8 vs. 20.8%) and clamp crushing technique (13.0 vs. 7.4%) for hepatic resection (Table 2). Likewise, there were differences in the proportion of patients receiving intraoperative blood transfusion. More participants had a history of chemotherapy for hepatic disease in the TachoSil group compared with the TachoComb group.
Table 1
Participants’ demographic and baseline characteristics
Characteristic
TachoSil N = 54
TachoComb N = 54
Males, n (%)
37 (68.5)
35 (64.8)
Age (years), mean ± SD
59.9 ± 12.2
65.5 ± 11.3
BMI (kg/m2), mean ± SD
23.7 ± 3.2
22.6 ± 2.8
Smokers, n (%)
20 (37.0)
8 (14.8)
Alcohol use, n (%)
23 (42.6)
20 (37.0)
Reason for surgery, n (%)
 Hepatic disease
48 (88.9)
52 (96.3)
 Liver donor
6 (11.1)
2 (3.7)
Child–Pugh classification, n (%)
 A
53 (98.1)
52 (96.3)
 B
1 (1.9)
2 (3.7)
Platelets (×104/μL), mean ± SD
20.7 ± 9.1
19.0 ± 6.7
Previous chemotherapy for hepatic disease, n (%)
19 (35.2)
8 (14.8)
BMI body mass index, SD standard deviation
Table 2
Participants’ surgical characteristics
Characteristic
TachoSil N = 54
TachoComb N = 54
Method of liver resection, n (%)
 CUSA
44 (81.5)
42 (77.8)
 Drip bipolar
8 (14.8)
11 (20.4)
 Harmonic scalpel
9 (16.7)
9 (16.7)
 Clamp crush
7 (13.0)
4 (7.4)
 Bipolar scissors
4 (7.4)
5 (9.3)
 Other
20 (37.0)
15 (27.8)
Number of resection sites, mean ± SD
2.6 ± 1.40
3.1 ± 1.5
Weight of liver resected (g), mean ± SD
315.3 ± 274.2
338.4 ± 302.1
Intraoperative blood transfusion, n (%)
 Before efficacy evaluation
0 (0)
3 (5.6)
 After efficacy evaluation
12 (22.2)
8 (14.8)
Blood flow occlusion, n (%)
47 (87.0)
49 (90.7)
Method of primary hemostasis, n (%)
 Suture
18 (33.3)
18 (33.3)
 Ligation
13 (24.1)
17 (31.5)
 Electrocoagulation
43 (79.6)
45 (83.3)
 Compression
23 (42.6)
19 (35.2)
Volume of bleeding (mL), mean ± SD
649.5 ± 932.2
666.3 ± 499.0
Size of patch used, n (%)
 9.5 × 4.8 cm
9 (16.7)
11 (20.4)
 4.8 × 4.8 cm
5 (9.3)
1 (1.9)
 2.4 × 4.8 cm
6 (11.1)
4 (7.4)
 2.4 × 2.4 cm
21 (38.9)
27 (50.0)
 Other
13 (24.1)
11 (20.4)
CUSA Cavitron ultrasonic surgical aspirator, SD standard deviation

Primary outcome measure

All participants in the efficacy analysis population in both study groups (TachoSil: 54/54, 100%; TachoComb: 54/54, 100%) achieved hemostasis 5 min after the application of study treatment. There was no difference in the response rate between study groups (p = 1.0). The 95% CI for the proportion of participants who achieved hemostasis at 5 min was 93.4 to 100% for both groups. The 95% CI for the difference in the proportion of participants who achieved hemostasis at 5 min between study groups was −4.9 to 4.9%, indicating that TachoSil was noninferior to TachoComb.

Safety

The proportion of participants who experienced AEs was generally similar between study groups (Table 3). All participants in both study groups experienced at least one AE; however, no participants discontinued because of an AE. Most (≥97.8%) AEs in both groups were classified as mild or moderate in severity. The incidence of possibly treatment-related AEs was greater in the TachoSil group than in the TachoComb group.
Table 3
Summary of adverse events
Adverse event
TachoSil N = 55
TachoComb N = 56
One or more AE, n (%)
55 (100.0)
56 (100.0)
One or more possibly treatment-related AE, n (%)
10 (18.2)
1 (1.8)
Discontinuation because of an AE, n (%)
0 (0)
0 (0)
One or more SAE, n (%)
7 (12.7)
9 (16.1)
Total AEs, n
329
303
 Mild, n (%)
263 (79.9)
232 (76.6)
 Moderate, n (%)
59 (17.9)
65 (21.5)
 Severe, n (%)
7 (2.1)
6 (2.0)
AE adverse event, SAE serious adverse event
A small number of participants experienced at least one serious AE (SAE), most of which were not considered to be related to study treatment. In the TachoSil group, seven participants experienced a total of eight SAEs, including ventricular flutter, peritonitis, intra-abdominal hemorrhage, pyrexia, post-procedural bile leak, atelectasis, aneurysm ruptured, and vascular pseudoaneurysm (all n = 1). The SAEs of post-procedural bile leak and peritonitis were considered to be possibly treatment related. The participant who experienced intra-abdominal hemorrhage died; this SAE was not considered to be related to study treatment because the event was a rupture caused by hepatic artery aneurysm resulting from the surgery. In the TachoComb group, nine participants experienced a total of 10 SAEs, including post-procedural bile leak (n = 4), and ventricular fibrillation, gastritis, abdominal abscess, upper limb fracture, chylothorax, and arterial hemorrhage (all n = 1). The SAE of ventricular fibrillation was considered to be possibly treatment related. One participant in the TachoComb group died after the study period due to worsening of underlying disease; this death was not considered to be related to study treatment.
The incidence of AEs (by preferred term) was generally similar between study groups (Table 4), with wound complication (defined as pruritus of the wound and periwound skin, wound pain, wound site pain, or wound pain in the buttocks) and pyrexia being the most commonly reported AEs, experienced by ≥73.2% of participants in both study groups.
Table 4
Adverse events occurring at a rate of >5%
Adverse event (preferred term), n (%)
TachoSil N = 55
TachoComb N = 56
Wound complicationa
51 (92.7)
47 (83.9)
Pyrexia
44 (80.0)
41 (73.2)
Insomnia
17 (30.9)
12 (21.4)
Vomiting
11 (20.0)
8 (14.3)
Nausea
10 (18.2)
10 (17.9)
Abdominal distension
9 (16.4)
6 (10.7)
Musculoskeletal pain
9 (16.4)
5 (8.9)
Pleural effusion
8 (14.5)
14 (25.0)
Constipation
8 (14.5)
9 (16.1)
Ascites
6 (10.9)
5 (8.9)
Diarrhea
5 (9.1)
8 (14.3)
Hyperglycemia
5 (9.1)
5 (8.9)
Atelectasis
5 (9.1)
5 (8.9)
Pain
4 (7.3)
2 (3.6)
Blood pressure increased
4 (7.3)
1 (1.8)
Post-procedural bile leak
3 (5.5)
8 (14.3)
Back pain
3 (5.5)
4 (7.1)
Pruritus
3 (5.5)
3 (5.4)
Urine output decreased
3 (5.5)
2 (3.6)
Erythema
3 (5.5)
2 (3.6)
Rash
3 (5.5)
2 (3.6)
Cholangitis
2 (3.6)
5 (8.9)
Delirium
1 (1.8)
7 (12.5)
Abdominal abscess
0 (0)
3 (5.4)
aPruritus of the wound and periwound skin, wound pain, wound site pain, or wound pain in the buttocks
Changes in laboratory values were similar between groups (data not shown). One participant in the TachoSil group experienced a clinically significant, but nonserious, abnormal laboratory value of C-reactive protein increase that was considered related to study treatment. There were no new cases of HBV, HBC, or HIV infection, nor were there any positive conversions for participants who had positive virus markers at the start of the study.

Discussion

This is the first randomized trial to compare the efficacy and safety of TachoSil and TachoComb in Japanese patients undergoing liver resection or living donors. We found that TachoSil has noninferior hemostatic efficacy compared with TachoComb and appears to have a similar safety profile. Our findings therefore suggest that the beneficial effects of TachoSil are similar to those of TachoComb and that TachoSil is an effective means of providing hemostasis in Japanese patients during surgery.
The primary finding of our study was that TachoSil and TachoComb provided similarly effective hemostasis within 5 min of application in all participants. The assessment of hemostasis was judged by the surgeon; however, the binary nature of the endpoint avoids any grading and thus renders some objectivity. This endpoint reflects the immediate pharmacodynamic effect of the products, and although of minor clinical relevance, this kind of efficacy endpoint is widely used and acknowledged as basis for the assessment of hemostatic effect of treatments in surgery [4, 15, 2022]. To our knowledge, no other published clinical study has directly compared the hemostatic efficacy of TachoSil and TachoComb. However, our findings are supported by those from nonclinical studies. [23] Notably, Agger et al. [13] found that TachoSil and TachoComb had similar hemostatic efficacy in a pig model of challenging aortic arterial bleeding. The findings from the current study support other published data showing that TachoSil is an effective means of providing hemostasis during liver resection. Specifically, two European, multicenter, randomized, controlled trials, involving 121 [16] and 119 [14] adults, respectively, demonstrated that TachoSil provided superior or significantly faster hemostasis compared with argon beamer during liver resection. Likewise, a US, multicenter, randomized, controlled trial, involving 224 adults, demonstrated that TachoSil provided superior hemostasis to Surgicel® during liver resection [20]. A small prospective study [15] involving 16 children undergoing liver resection also demonstrated that 81.3% of participants had effective hemostasis within 3 min of application of TachoSil. Further, TachoSil has also been reported to provide effective hemostasis during various other types of surgery, including lung surgery [24, 25], kidney tumor resection [22], prostate surgery [26], gynecological surgery [2729], and cardiovascular surgery in patients requiring cardiopulmonary bypass [21]. The current published literature on use of TachoSil in Japan is restricted to a recently published retrospective study [30], a case report [31], and a case series [32]. In the retrospective study, which involved 75 patients, the application of TachoSil or TachoComb to the staple line of the pancreas after distal pancreatectomy was associated with a low rate of fistula formation [30]. The case report [31] and case series [32] describe successful pulmonary and renal application, respectively.
TachoSil was developed to reduce the potential for immunogenic effects in response to bovine thrombin and bovine aprotinin with repeated use, and to remove the potential for horizontal disease transfer (bovine to human). While no specific antibody testing was undertaken in the current analyses, a recent study reported that among 97 patients using TachoSil for the secondary treatment of local bleeding after hepatic resection, immunogenicity findings did not appear to be clinically significant [20]. No treatment emergent AEs related to immune response were reported in the initial 6-month follow-up period, and no medical conditions potentially related to antibody development were observed in an extended follow-up of up to 2 years.
We did not aim to assess the long-term safety of TachoSil in this study; however, the safety profile of TachoSil in clinical practice has been confirmed in postmarketing settings [33], through an estimated 5.2 million patient exposures worldwide (data on file). The findings from randomized controlled trials of TachoSil carried out in Europe, involving participants undergoing liver resection [14, 16] and other types of surgery [21, 22, 24], have also confirmed the favorable safety profile of TachoSil. Our study findings indicate that the safety profiles of TachoSil and TachoComb are similar for up to 28 days following use for hemostasis in Japanese patients undergoing liver resection or living donors. Treatment-related AEs were more common in the TachoSil group than in the TachoComb group. This difference likely relates to a random imbalance in treatment assignment to two investigators, both of whom practiced standards for the evaluation of the definition of “causal relationship” differently from the other investigators. All other aspects of safety including total AEs and patients with one or more SAEs were similar in the two treatment groups. Most AEs were of mild or moderate severity and few SAEs were reported. The incidence of AEs in our study is also higher than the incidence of AEs in the European studies of patients undergoing liver resection (100% of participants vs. 42 to 44% of participants [14, 16]). We suggest that this disparity likely reflects methodological differences in the prespecified criteria for recording or not recording specific AEs or the cautious practice of Japanese investigators. In particular, AEs that are common after liver resection, such as wound complication, nausea, vomiting, and pain, were recorded in our study, but not in the European studies.
A key strength of this study is the prospective, randomized, double-blind, multicenter design with predefined statistical analyses based on the intention-to-treat paradigm. Limitations include the length of follow-up, which may have been insufficient to detect longer term postoperative morbidities, and the moderate number of participants. Additionally, one of the authors (M. Kobayashi) was sponsor-affiliated, which incurs a risk of bias [34]. However, the primary contributors to the study design and the scientific interpretation of the data were the authors affiliated with academic research institutions.

Conclusion

This study demonstrated that TachoSil has noninferior hemostatic efficacy compared with TachoComb, and a similar safety profile, in patients undergoing liver resection.

Acknowledgements

CSL Behring was involved in the study design, data collection, data analysis, and preparation of the manuscript. Takeda Pharmaceutical Company Ltd. was involved in the preparation of the manuscript.

Authors’ contributions

All authors participated in the interpretation of study results, and in the drafting, critical revision, and approval of the final version of the manuscript. SK and MK were involved in designing the study. MK was involved in the data collection. MK and HO were involved in the statistical analyses.

Other contributors

This clinical trial was conducted at 11 sites in Japan: Hokkaido University Hospital, Tohoku University Hospital, Chiba University Hospital, Tokyo Women’s Medical University Hospital, Kanazawa University Hospital, Kyoto University Hospital, Osaka University Hospital, Osaka Medical Center for Cancer and Cardiovascular Diseases, Okayama University Hospital, Kyushu University Hospital, and Kumamoto University Hospital.

Compliance with ethical standards

Conflict of interest

SK has received research funding from CSL Behring K.K. MK is an employee of CSL Behring K.K. HO has no conflicts of interest to declare.

Funding

This study was sponsored by CSL Behring K.K. Medical writing assistance was provided by Luke Carey, PhD, and Serina Stretton, PhD, CMPP, of ProScribe—part of the Envision Pharma Group—and was funded by Takeda Pharmaceutical Company Ltd. ProScribe’s services complied with international guidelines for Good Publication Practice (GPP3).
Informed consent was obtained from all individual participants included in the study.
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Unsere Produktempfehlungen

Die Chirurgie

Print-Titel

Das Abo mit mehr Tiefe

Mit der Zeitschrift Die Chirurgie erhalten Sie zusätzlich Online-Zugriff auf weitere 43 chirurgische Fachzeitschriften, CME-Fortbildungen, Webinare, Vorbereitungskursen zur Facharztprüfung und die digitale Enzyklopädie e.Medpedia.

Bis 30. April 2024 bestellen und im ersten Jahr nur 199 € zahlen!

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Literatur
1.
Zurück zum Zitat Ekberg H, Tranberg KG, Andersson R, Jeppsson B, Bengmark S (1986) Major liver resection: perioperative course and management. Surgery 100(1):1–8PubMed Ekberg H, Tranberg KG, Andersson R, Jeppsson B, Bengmark S (1986) Major liver resection: perioperative course and management. Surgery 100(1):1–8PubMed
2.
Zurück zum Zitat Alfieri S, Carriero C, Caprino P, Di Giorgio A, Sgadari A, Crucitti F, Doglietto GB (2001) Avoiding early postoperative complications in liver surgery. A multivariate analysis of 254 patients consecutively observed. Dig Liver Dis 33(4):341–346PubMedCrossRef Alfieri S, Carriero C, Caprino P, Di Giorgio A, Sgadari A, Crucitti F, Doglietto GB (2001) Avoiding early postoperative complications in liver surgery. A multivariate analysis of 254 patients consecutively observed. Dig Liver Dis 33(4):341–346PubMedCrossRef
3.
Zurück zum Zitat Imamura H, Seyama Y, Kokudo N, Maema A, Sugawara Y, Sano K, Takayama T, Makuuchi M (2003) One thousand fifty-six hepatectomies without mortality in 8 years. Arch Surg 138(11):1198–1206PubMedCrossRef Imamura H, Seyama Y, Kokudo N, Maema A, Sugawara Y, Sano K, Takayama T, Makuuchi M (2003) One thousand fifty-six hepatectomies without mortality in 8 years. Arch Surg 138(11):1198–1206PubMedCrossRef
4.
Zurück zum Zitat Chapman WC, Clavien PA, Fung J, Khanna A, Bonham A (2000) Effective control of hepatic bleeding with a novel collagen-based composite combined with autologous plasma: results of a randomized controlled trial. Arch Surg 135(10):1200–1205PubMedCrossRef Chapman WC, Clavien PA, Fung J, Khanna A, Bonham A (2000) Effective control of hepatic bleeding with a novel collagen-based composite combined with autologous plasma: results of a randomized controlled trial. Arch Surg 135(10):1200–1205PubMedCrossRef
5.
Zurück zum Zitat Alkozai EM, Lisman T, Porte RJ (2009) Bleeding in liver surgery: prevention and treatment. Clin Liver Dis 13(1):145–154PubMedCrossRef Alkozai EM, Lisman T, Porte RJ (2009) Bleeding in liver surgery: prevention and treatment. Clin Liver Dis 13(1):145–154PubMedCrossRef
6.
Zurück zum Zitat Stellingwerff M, Brandsma A, Lisman T, Porte RJ (2012) Prohemostatic interventions in liver surgery. Semin Thromb Hemost 38(3):244–249PubMedCrossRef Stellingwerff M, Brandsma A, Lisman T, Porte RJ (2012) Prohemostatic interventions in liver surgery. Semin Thromb Hemost 38(3):244–249PubMedCrossRef
7.
Zurück zum Zitat Berrevoet F, de Hemptinne B (2007) Use of topical hemostatic agents during liver resection. Dig Surg 24(4):288–293PubMedCrossRef Berrevoet F, de Hemptinne B (2007) Use of topical hemostatic agents during liver resection. Dig Surg 24(4):288–293PubMedCrossRef
8.
Zurück zum Zitat Seyednejad H, Imani M, Jamieson T, Seifalian AM (2008) Topical haemostatic agents. Br J Surg 95(10):1197–1225PubMedCrossRef Seyednejad H, Imani M, Jamieson T, Seifalian AM (2008) Topical haemostatic agents. Br J Surg 95(10):1197–1225PubMedCrossRef
9.
Zurück zum Zitat Ding H, Yuan JQ, Zhou JH, Zheng XY, Ye P, Mao C, Chen Q (2013) Systematic review and meta-analysis of application of fibrin sealant after liver resection. Curr Med Res Opin 29(4):387–394PubMedCrossRef Ding H, Yuan JQ, Zhou JH, Zheng XY, Ye P, Mao C, Chen Q (2013) Systematic review and meta-analysis of application of fibrin sealant after liver resection. Curr Med Res Opin 29(4):387–394PubMedCrossRef
10.
Zurück zum Zitat Ortel TL, Mercer MC, Thames EH, Moore KD, Lawson JH (2001) Immunologic impact and clinical outcomes after surgical exposure to bovine thrombin. Ann Surg 233(1):88–96PubMedPubMedCentralCrossRef Ortel TL, Mercer MC, Thames EH, Moore KD, Lawson JH (2001) Immunologic impact and clinical outcomes after surgical exposure to bovine thrombin. Ann Surg 233(1):88–96PubMedPubMedCentralCrossRef
11.
Zurück zum Zitat Scheule AM, Beierlein W, Wendel HP, Eckstein FS, Heinemann MK, Ziemer G (1998) Fibrin sealant, aprotinin, and immune response in children undergoing operations for congenital heart disease. J Thorac Cardiovasc Surg 115(4):883–889PubMedCrossRef Scheule AM, Beierlein W, Wendel HP, Eckstein FS, Heinemann MK, Ziemer G (1998) Fibrin sealant, aprotinin, and immune response in children undergoing operations for congenital heart disease. J Thorac Cardiovasc Surg 115(4):883–889PubMedCrossRef
12.
Zurück zum Zitat Shirai T, Shimota H, Chida K, Sano S, Takeuchi Y, Yasueda H (2005) Anaphylaxis to aprotinin in fibrin sealant. Intern Med 44(10):1088–1089PubMedCrossRef Shirai T, Shimota H, Chida K, Sano S, Takeuchi Y, Yasueda H (2005) Anaphylaxis to aprotinin in fibrin sealant. Intern Med 44(10):1088–1089PubMedCrossRef
13.
Zurück zum Zitat Agger P, Langhoff J, Smerup MH, Hasenkam JM (2010) Comparison between TachoComb and TachoSil for surgical hemostasis in arterial bleeding: an animal experimental study. J Trauma 68(4):838–842PubMedCrossRef Agger P, Langhoff J, Smerup MH, Hasenkam JM (2010) Comparison between TachoComb and TachoSil for surgical hemostasis in arterial bleeding: an animal experimental study. J Trauma 68(4):838–842PubMedCrossRef
14.
Zurück zum Zitat Fischer L, Seiler CM, Broelsch CE, de Hemptinne B, Klempnauer J, Mischinger HJ, Gassel HJ, Rokkjaer M, Schauer R, Larsen PN, Tetens V, Buchler MW (2011) Hemostatic efficacy of TachoSil in liver resection compared with argon beam coagulator treatment: an open, randomized, prospective, multicenter, parallel-group trial. Surgery 149(1):48–55PubMedCrossRef Fischer L, Seiler CM, Broelsch CE, de Hemptinne B, Klempnauer J, Mischinger HJ, Gassel HJ, Rokkjaer M, Schauer R, Larsen PN, Tetens V, Buchler MW (2011) Hemostatic efficacy of TachoSil in liver resection compared with argon beam coagulator treatment: an open, randomized, prospective, multicenter, parallel-group trial. Surgery 149(1):48–55PubMedCrossRef
15.
Zurück zum Zitat Mirza D, Millar AJ, Sharif K, Vilca-Melendez H, Rela M, Heaton N (2011) The use of TachoSil in children undergoing liver resection with or without segmental liver transplantation. Eur J Pediatr Surg 21(2):111–115PubMedCrossRef Mirza D, Millar AJ, Sharif K, Vilca-Melendez H, Rela M, Heaton N (2011) The use of TachoSil in children undergoing liver resection with or without segmental liver transplantation. Eur J Pediatr Surg 21(2):111–115PubMedCrossRef
16.
Zurück zum Zitat Frilling A, Stavrou GA, Mischinger HJ, de Hemptinne B, Rokkjaer M, Klempnauer J, Thorne A, Gloor B, Beckebaum S, Ghaffar MF, Broelsch CE (2005) Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial. Langenbeck’s Arch Surg 390(2):114–120CrossRef Frilling A, Stavrou GA, Mischinger HJ, de Hemptinne B, Rokkjaer M, Klempnauer J, Thorne A, Gloor B, Beckebaum S, Ghaffar MF, Broelsch CE (2005) Effectiveness of a new carrier-bound fibrin sealant versus argon beamer as haemostatic agent during liver resection: a randomised prospective trial. Langenbeck’s Arch Surg 390(2):114–120CrossRef
17.
Zurück zum Zitat Singhal D, Smorodinsky E, Guo L (2011) Differences in coagulation among Asians and Caucasians and the implication for reconstructive microsurgery. J Reconstr Microsurg 27(1):57–62PubMedCrossRef Singhal D, Smorodinsky E, Guo L (2011) Differences in coagulation among Asians and Caucasians and the implication for reconstructive microsurgery. J Reconstr Microsurg 27(1):57–62PubMedCrossRef
19.
Zurück zum Zitat Wilson EB (1927) Probable inference, the law of succession, and statistical inference. J Am Stat Assoc 22209–22212 Wilson EB (1927) Probable inference, the law of succession, and statistical inference. J Am Stat Assoc 22209–22212
20.
Zurück zum Zitat Genyk Y, Kato T, Pomposelli JJ, Wright JK Jr, Sher LS, Tetens V, Chapman WC (2016) Fibrin sealant patch (TachoSil) vs oxidized regenerated cellulose patch (Surgicel original) for the secondary treatment of local bleeding in patients undergoing hepatic resection: a randomized controlled trial. J Am Coll Surg 222(3):261–268PubMedCrossRef Genyk Y, Kato T, Pomposelli JJ, Wright JK Jr, Sher LS, Tetens V, Chapman WC (2016) Fibrin sealant patch (TachoSil) vs oxidized regenerated cellulose patch (Surgicel original) for the secondary treatment of local bleeding in patients undergoing hepatic resection: a randomized controlled trial. J Am Coll Surg 222(3):261–268PubMedCrossRef
21.
Zurück zum Zitat Maisano F, Kjaergard HK, Bauernschmitt R, Pavie A, Rabago G, Laskar M, Marstein JP, Falk V (2009) TachoSil surgical patch versus conventional haemostatic fleece material for control of bleeding in cardiovascular surgery: a randomised controlled trial. Eur J Cardiothorac Surg 36(4):708–714PubMedCrossRef Maisano F, Kjaergard HK, Bauernschmitt R, Pavie A, Rabago G, Laskar M, Marstein JP, Falk V (2009) TachoSil surgical patch versus conventional haemostatic fleece material for control of bleeding in cardiovascular surgery: a randomised controlled trial. Eur J Cardiothorac Surg 36(4):708–714PubMedCrossRef
22.
Zurück zum Zitat Siemer S, Lahme S, Altziebler S, Machtens S, Strohmaier W, Wechsel HW, Goebell P, Schmeller N, Oberneder R, Stolzenburg JU, Becker H, Luftenegger W, Tetens V, Van Poppel H (2007) Efficacy and safety of TachoSil as haemostatic treatment versus standard suturing in kidney tumour resection: a randomised prospective study. Eur Urol 52(4):1156–1163PubMedCrossRef Siemer S, Lahme S, Altziebler S, Machtens S, Strohmaier W, Wechsel HW, Goebell P, Schmeller N, Oberneder R, Stolzenburg JU, Becker H, Luftenegger W, Tetens V, Van Poppel H (2007) Efficacy and safety of TachoSil as haemostatic treatment versus standard suturing in kidney tumour resection: a randomised prospective study. Eur Urol 52(4):1156–1163PubMedCrossRef
23.
Zurück zum Zitat Erdogan D, van Gulik TM (2008) Evolution of fibrinogen-coated collagen patch for use as a topical hemostatic agent. J Biomed Mater Res B Appl Biomater 85(1):272–278PubMedCrossRef Erdogan D, van Gulik TM (2008) Evolution of fibrinogen-coated collagen patch for use as a topical hemostatic agent. J Biomed Mater Res B Appl Biomater 85(1):272–278PubMedCrossRef
24.
Zurück zum Zitat Marta GM, Facciolo F, Ladegaard L, Dienemann H, Csekeo A, Rea F, Dango S, Spaggiari L, Tetens V, Klepetko W (2010) Efficacy and safety of TachoSil(R) versus standard treatment of air leakage after pulmonary lobectomy. Eur J Cardiothorac Surg 38(6):683–689PubMedCrossRef Marta GM, Facciolo F, Ladegaard L, Dienemann H, Csekeo A, Rea F, Dango S, Spaggiari L, Tetens V, Klepetko W (2010) Efficacy and safety of TachoSil(R) versus standard treatment of air leakage after pulmonary lobectomy. Eur J Cardiothorac Surg 38(6):683–689PubMedCrossRef
25.
Zurück zum Zitat Anegg U, Lindenmann J, Matzi V, Smolle J, Maier A, Smolle-Juttner F (2007) Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery: a prospective randomised trial. Eur J Cardiothorac Surg 31(2):198–202PubMedCrossRef Anegg U, Lindenmann J, Matzi V, Smolle J, Maier A, Smolle-Juttner F (2007) Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery: a prospective randomised trial. Eur J Cardiothorac Surg 31(2):198–202PubMedCrossRef
26.
Zurück zum Zitat Simonato A, Varca V, Esposito M, Venzano F, Carmignani G (2009) The use of a surgical patch in the prevention of lymphoceles after extraperitoneal pelvic lymphadenectomy for prostate cancer: a randomized prospective pilot study. J Urol 182(5):2285–2290PubMedCrossRef Simonato A, Varca V, Esposito M, Venzano F, Carmignani G (2009) The use of a surgical patch in the prevention of lymphoceles after extraperitoneal pelvic lymphadenectomy for prostate cancer: a randomized prospective pilot study. J Urol 182(5):2285–2290PubMedCrossRef
27.
Zurück zum Zitat Tinelli A, Giorda G, Manca C, Pellegrino M, Prudenzano R, Guido M, Dell’Edera D, Malvasi A (2012) Prevention of lymphocele in female pelvic lymphadenectomy by a collagen patch coated with the human coagulation factors: a pilot study. J Surg Oncol 105(8):835–840PubMedCrossRef Tinelli A, Giorda G, Manca C, Pellegrino M, Prudenzano R, Guido M, Dell’Edera D, Malvasi A (2012) Prevention of lymphocele in female pelvic lymphadenectomy by a collagen patch coated with the human coagulation factors: a pilot study. J Surg Oncol 105(8):835–840PubMedCrossRef
28.
Zurück zum Zitat Buda A, Fruscio R, Pirovano C, Signorelli M, Betti M, Milani R (2012) The use of TachoSil for the prevention of postoperative complications after groin dissection in cases of gynecologic malignancy. Int J Gynaecol Obstet 117(3):217–219PubMedCrossRef Buda A, Fruscio R, Pirovano C, Signorelli M, Betti M, Milani R (2012) The use of TachoSil for the prevention of postoperative complications after groin dissection in cases of gynecologic malignancy. Int J Gynaecol Obstet 117(3):217–219PubMedCrossRef
29.
Zurück zum Zitat Di Monta G, Caraco C, Crispo A, Marone U, Mozzillo N (2012) Collagen sealant patch to reduce lymphatic drainage after lymph node dissection. World J Surg Oncol 10275 Di Monta G, Caraco C, Crispo A, Marone U, Mozzillo N (2012) Collagen sealant patch to reduce lymphatic drainage after lymph node dissection. World J Surg Oncol 10275
30.
Zurück zum Zitat Mita K, Ito H, Murabayashi R, Asakawa H, Nabetani M, Kamasako A, Koizumi K, Hayashi T (2015) Use of a fibrinogen/thrombin-based collagen fleece (TachoComb, TachoSil) with a stapled closure to prevent pancreatic fistula formation following distal pancreatectomy. Surg Innov. doi:10.1177/1553350615580649 Mita K, Ito H, Murabayashi R, Asakawa H, Nabetani M, Kamasako A, Koizumi K, Hayashi T (2015) Use of a fibrinogen/thrombin-based collagen fleece (TachoComb, TachoSil) with a stapled closure to prevent pancreatic fistula formation following distal pancreatectomy. Surg Innov. doi:10.​1177/​1553350615580649​
31.
Zurück zum Zitat Konishi Y, Yamamoto H, Hiraki T, Soh J, Toyooka S, Kanazawa S, Miyoshi S (2014) Massive subcutaneous and mediastinal emphysema with little pneumothorax treated by surgery after pulmonary radiofrequency ablation. Cardiovasc Intervent Radiol 37(2):548–551PubMedCrossRef Konishi Y, Yamamoto H, Hiraki T, Soh J, Toyooka S, Kanazawa S, Miyoshi S (2014) Massive subcutaneous and mediastinal emphysema with little pneumothorax treated by surgery after pulmonary radiofrequency ablation. Cardiovasc Intervent Radiol 37(2):548–551PubMedCrossRef
32.
Zurück zum Zitat Kinoshita H, Sugi M, Matsuda T (2013) Renal parenchymal non-suturing technique using tachosil tissue sealing sheet in laparoscopic partial nephrectomy. J Endourol 27(Suppl 1):A398 Kinoshita H, Sugi M, Matsuda T (2013) Renal parenchymal non-suturing technique using tachosil tissue sealing sheet in laparoscopic partial nephrectomy. J Endourol 27(Suppl 1):A398
33.
Zurück zum Zitat Birth M, Figueras J, Bernardini S, Troen T, Gunther K, Mirza D, Mortensen FV (2009) Collagen fleece-bound fibrin sealant is not associated with an increased risk of thromboembolic events or major bleeding after its use for haemostasis in surgery: a prospective multicentre surveillance study. Patient Saf Surg 3(1):13PubMedPubMedCentralCrossRef Birth M, Figueras J, Bernardini S, Troen T, Gunther K, Mirza D, Mortensen FV (2009) Collagen fleece-bound fibrin sealant is not associated with an increased risk of thromboembolic events or major bleeding after its use for haemostasis in surgery: a prospective multicentre surveillance study. Patient Saf Surg 3(1):13PubMedPubMedCentralCrossRef
34.
Zurück zum Zitat Probst P, Knebel P, Grummich K, Tenckhoff S, Ulrich A, Buchler MW, Diener MK (2016) Industry bias in randomized controlled trials in general and abdominal surgery: an empirical study. Ann Surg 264(1):87–92PubMedCrossRef Probst P, Knebel P, Grummich K, Tenckhoff S, Ulrich A, Buchler MW, Diener MK (2016) Industry bias in randomized controlled trials in general and abdominal surgery: an empirical study. Ann Surg 264(1):87–92PubMedCrossRef
Metadaten
Titel
Comparison of TachoSil and TachoComb in patients undergoing liver resection—a randomized, double-blind, non-inferiority trial
verfasst von
S. Kawasaki
H. Origasa
V. Tetens
M. Kobayashi
Publikationsdatum
01.04.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Langenbeck's Archives of Surgery / Ausgabe 4/2017
Print ISSN: 1435-2443
Elektronische ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-017-1571-z

Weitere Artikel der Ausgabe 4/2017

Langenbeck's Archives of Surgery 4/2017 Zur Ausgabe

Update Chirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.

S3-Leitlinie „Diagnostik und Therapie des Karpaltunnelsyndroms“

CME: 2 Punkte

Prof. Dr. med. Gregor Antoniadis Das Karpaltunnelsyndrom ist die häufigste Kompressionsneuropathie peripherer Nerven. Obwohl die Anamnese mit dem nächtlichen Einschlafen der Hand (Brachialgia parästhetica nocturna) sehr typisch ist, ist eine klinisch-neurologische Untersuchung und Elektroneurografie in manchen Fällen auch eine Neurosonografie erforderlich. Im Anfangsstadium sind konservative Maßnahmen (Handgelenksschiene, Ergotherapie) empfehlenswert. Bei nicht Ansprechen der konservativen Therapie oder Auftreten von neurologischen Ausfällen ist eine Dekompression des N. medianus am Karpaltunnel indiziert.

Prof. Dr. med. Gregor Antoniadis
Berufsverband der Deutschen Chirurgie e.V.

S2e-Leitlinie „Distale Radiusfraktur“

CME: 2 Punkte

Dr. med. Benjamin Meyknecht, PD Dr. med. Oliver Pieske Das Webinar S2e-Leitlinie „Distale Radiusfraktur“ beschäftigt sich mit Fragen und Antworten zu Diagnostik und Klassifikation sowie Möglichkeiten des Ausschlusses von Zusatzverletzungen. Die Referenten erläutern, welche Frakturen konservativ behandelt werden können und wie. Das Webinar beantwortet die Frage nach aktuellen operativen Therapiekonzepten: Welcher Zugang, welches Osteosynthesematerial? Auf was muss bei der Nachbehandlung der distalen Radiusfraktur geachtet werden?

PD Dr. med. Oliver Pieske
Dr. med. Benjamin Meyknecht
Berufsverband der Deutschen Chirurgie e.V.

S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“

CME: 2 Punkte

Dr. med. Mihailo Andric
Inhalte des Webinars zur S1-Leitlinie „Empfehlungen zur Therapie der akuten Appendizitis bei Erwachsenen“ sind die Darstellung des Projektes und des Erstellungswegs zur S1-Leitlinie, die Erläuterung der klinischen Relevanz der Klassifikation EAES 2015, die wissenschaftliche Begründung der wichtigsten Empfehlungen und die Darstellung stadiengerechter Therapieoptionen.

Dr. med. Mihailo Andric
Berufsverband der Deutschen Chirurgie e.V.