Abstract

The purpose of this study was to assess by multislice computed tomography (MSCT) imaging geometry of the ascending aorta, the aortic root, the aortic annulus and the left ventricle outflow tract (LVOT) in aortic stenosis (AS) patients, to compare aortic root morphology in patients with AS with healthy controls and to evaluate sex differences. Fifty patients with severe AS and 50 age- and gender-matched controls who underwent MSCT were included in the study. The dimensions of the LVOT, the aortic annulus, the aortic root, the ascending aorta, and the volume of the aortic root were retrospectively assessed and a comparison was made between patients with severe tricuspid AS and controls. Patients with tricuspid AS in comparison with controls had smaller dimensions of the sinus of Valsalva resulting in reduction of the aortic root volume, whereas the dimensions of the other structures were comparable. MSCT revealed larger annular, LVOT and the sinus of Valsalva dimensions and the aortic root volume in men than women. Men with AS differed from healthy men only in regard to the dimensions of the sinus of Valsalva, while women showed significant differences also in the LVOT, and the aortic annulus. MSCT showed accurately aortic root remodeling in tricuspid AS patients and indentified sex-dependent differences. Women with tricuspid AS differ from healthy women more than men did. A high degree of the variability in the aortic root dimensions requires further careful research.
Hinweise

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Introduction

Aortic stenosis (AS) is the most common native valve disease [1] occurring more and more frequently due to the ageing population [2]. Aortic valve is a part of the sophisticated structure of the aortic root. The aortic root is the continuation of the left ventricular outflow tract (LVOT), which is located between the basal attachment of the aortic valvar leaflets and the sinotubular junction (STJ) [3]. It includes the aortic valve annulus with leaflets and the sinus of Valsalva [3].
Detailed knowledge of the aortic root geometry is essential to understand the mechanism or pathophysiology of valvular heart disease and clinical consequences resulting from valvular disruption. Careful assessment of the aortic root geometry is crucial to surgical repair techniques used for treatment various diseases of the aortic root. Moreover, in the era of transcatheter aortic valve implantation (TAVI), advanced and precise evaluation is essential in the accurate positioning of the prosthesis in the aortic annulus, prosthesis sizing as well as avoidance of the covering of the coronary ostia by the upper part of the prosthesis or occlusion of the left coronary artery [4]. Currently there is still paucity of data about detailed assessment of the aortic root geometry in aortic stenosis compared to both healthy people and between genders and the further studies are necessary.
The preferred imaging tool to assess the anatomy and dimensions of the aortic root is multislice computed tomography (MSCT) [2].
The aim of this study was to characterize geometry of the ascending aorta, the aortic root, the aortic annulus and the left ventricle outflow tract (LVOT) in aortic stenosis, to assess whether aortic root geometry differs between AS patients and those without valvular heart disease, and to identify sex differences.

Materials and methods

Study group

Retrospectively, aortic root geometry was assessed and compared between patients with severe tricuspid aortic valve stenosis and controls without valvular disease in this single center study. All data were indexed to the body surface area (BSA).
25 consecutive women and 25 consecutive men with severe AS who underwent MSCT and transthoracic echocardiography (TTE) before TAVI in 2015-2018 at our Institute were included in the study. Age-matched 25 women and men without valvular pathology, who were subjected to coronary angiography CT due to suspected coronary artery regression were enrolled in a control group.
Exclusion criteria included renal failure, hypersensitivity to iodinated contrast material and bicuspid aortic valve. The aspect of the aortic valve, the tricuspid or the bicuspid one were assessed by TTE and MSCT.

Multislice computed tomography

All patients underwent computed tomography scanning using dual source scanner Somatom Force (Siemens Healthcare, Forchheim, Germany) with the following parameters: 2 × 192 slices with 0.6-mm collimation, gantry rotation time 250 ms, tube voltage 70-100 kV, tube current 320–500 mAs (depending on the patient body mass). In both groups, non-enhanced prospectively ECG-gated scan (75% of R–R interval) with a slice thickness of 3 mm was performed to measure the calcium score of the aortic valve according to the modified Agatston method using dedicated calcium scoring software [5].
After a non-enhanced scan, a retrospectively ECG-gated helical CT angiography was performed in both groups (controls and in patients with severe AS). To minimize radiation exposure, electrocardiographically-gated tube current modulation was applied in all patients. The scan covered the heart (extending from the tracheal bifurcation to the diaphragm). In patients with AS, the ECG-gated data acquisition was followed by a non–ECG-gated CT angiographic scan of the chest, the abdomen, and the pelvis for the assessment of an access route. Iodinated contrast material (350–370 mg/ml) was injected intravenously at a flow rate of 4.5 ml/s.
CT acquisition parameters were slice collimation 192 × 0.6 mm, gantry rotation time 250 ms, tube voltage 70–100 kV, tube current 320–500 mAs (depending on the patient body mass), pitch of 0.16–0.3 (depending of the heart rate).
The dataset of the contrast-enhanced scan was reconstructed every 10% of the R–R interval.
Detailed assessments of aortic root anatomy and the ascending aorta were performed. Measurements were taken using dedicated software syngo.via (Siemens Healthcare, Forchheim, Germany).
The aortic annulus was assessed in the oblique transversal plane which crossed the level of the most basal attachments of the aortic cusps. The dimensions of the aortic root at the level of the STJ and the widest portion of the sinus of Valsalva were measured in the oblique transversal plane perpendicular to the course of the aorta [6].
The following measurements of the aortic root and the aortic valve were performed using MPRs: the long axis (maximum) of annulus, the short axis (minimum) of the annulus, the area of annulus (defined as an oval or a circle formed by linking the most basal portions of the leaflet attachments) [6], the perimeter of the annulus, the widest and the highest portion of the sinus of Valsalva diameter, the area and the perimeter of the sinus of Valsalva (Fig. 1a–d). The sinus of Valsalva was measured on the level of the widest diameter from one sinus to another sinus. The average of three sinus-to-sinus measurements were calculated. The sinus of Valsalva height was measure from the annular plain to the highest point of the right and the left sinus of Valsalva. The area, the perimeter and the diameter of the ascending aorta were measured 4.5 cm above the annulus on a transverse double oblique plane perpendicular to the long axis of the ascending aorta. The volume of the aortic root was calculated from the annular plane to the lowest point of the sinotubular junction using syngo.via VOI freehand Siemens software (Fig. 1e). All diameter measurements were assessed in the systolic phase. The aortic wall and calcifications were included to all dimensions.
The shape of the LVOT, the aortic annulus, the STJ and the ascending aorta was assessed by the ellipticity index (EI). The ellipticity index defined as maximal diameter (Dmax) divided by minimal diameter (Dmin) and the circular shape was established for EI < 1.1, which means that the difference between Dmax and Dmin was <10% of Dmin [4].
All analyses were assessed by a single expert reader experienced in cardiac CT and trained in the interpretation of CT scans before TAVI procedure.

Echocardiography

A standard comprehensive TTE was performed in each patient. The Vivid S70 and E9 (General Electric Medical Systems, Milwaukee, WI, USA) were used. Echocardiographic measurements were performed by qualified echocardiographers experienced in the quantitative assessment of valvular heart diseases.
According to the latest guidelines of the European Society of Cardiology (ESC) [2], severe AS was determined quantitatively on the basis of the aortic valve area < 1.0 cm2, mean aortic gradient > 40 mmHg, or aortic jet velocity > 4.0 m/s.
TTE data were collected, including the left ventricular end-diastolic diameter (LVEDD), the LV end-systolic diameter (LVESD), the interventricular septum (IVS) diameter at the end-diastole, and the end-diastolic posterior wall thickness (PW), the left ventricle ejection fraction (LVEF). All measurements were made in the parasternal long axis view.

Statistical analysis

All data were presented as absolute values and values indexed to BSA.
Continuous data were presented depending on the distribution as mean ± standard deviation (SD) or median and range of values, and categorical variables are presented as frequency and percentages. The data distribution was verified by the Kolmogorov–Smirnov test. The T-test, the Chi square, and the Mann–Whitney test were performed for data analysis. Correlations between variables were assessed with the Pearson’s correlation coefficient. All P values were two-sided and a P value < 0.05 was considered to be statistically significant.

Ethics statement

The study was carried out in accordance with the Declaration of Helsinki of the World Medical Association. The protocol for the study was reviewed and approved by the Ethics Committee on Human Studies (IK-NPIA-0021-74/1733/2018). Each participant read and signed the informed consent form after study procedures had been fully explained. Study subjects were not compensated for their participation. This article does not contain any studies with animals performed by any of the authors.

Results

The baseline clinical characteristics and echocardiographics data of the study and the control group are summarized in Table 1.
Table 1
Demographic, clinical, laboratory and echocardiographics characteristics of patients
 
Study group (n = 50)
Control group (n = 50)
p value
Age (years)
74.4 ± 6.9
74.4 ± 5.7
0.99
Male
25 (50%)
25 (50%)
1
Weight (kg)
80.6 ± 16.7
80 ± 12
0.85
Height (cm)
166 ± 8.7
170 ± 11.8
0.59
Body mass index (kg/m2)
29.5 ± 7
27.7 ± 3.3
0.11
Body surface area (m2)
1.9 ± 0.2
1.9 ± 0.2
0.75
Past medical history
 Hypertension
36 (72%)
36 (72%)
1
 Coronary artery disease
33 (66%)
35 (70%)
0.67
 Atrial fibrillation
14 (28%)
16 (32%)
0.66
 Diabetes mellitus
22 (44%)
8 (16%)
0.02
 eGFR (ml/min/1.63 m2)
64.3 ± 20.9
67.3 ± 15
0.44
Echocardiographics data
 LV end-systolic diameter, (mm)
30.3 ± 7.2
32.1 ± 10.2
0.46
 LV end-diastolic diameter, (mm)
48.5 ± 7.3
49.8 ± 7.3
0.4
 IVS in diastole, (mm)
14.9 ± 2.4
11.7 ± 2.1
<0.001
 PW in diastole, (mm)
11.8 ± 2
10.5 ± 1.9
0.005
 LVEF, (%)
57.1 ± 12.9
56.1 ± 11.6
0.73
 Left atrial diameter (cm)
4.3 ± 1.3
4.3 ± 0.7
0.99
 Left atrial area (cm2)
25.5 ± 4.8
24.2 ± 7.1
0.42
 Severe mitral regurgitation
2 (4%)
0 (0%)
0.31
 Severe aortic regurgitation
1 (2%)
0 (0%)
0.92
 Severe tricuspid regurgitation
1 (2%)
0 (0%)
0.92
 Aortic valve area (equation of continuity), (cm2)
0.6 ± 0.2
  
 Peak aortic gradient, (mm Hg)
85.1 ± 28.2
  
 Mean aortic gradient, (mmHg)
52.6 ± 16.8
  
 Maximal aortic valve velocity (m/s)
4.6 ± 0.7
  
Absolute aortic valve calcium score and indexed to body surface area were higher in patients with AS compared with controls (3050.45 ± 1412.3 AU vs. 26.09 ± 73.9 AU; p < 0.001 and 1619.29 ± 783.1 AU/m2 vs. 12.36 ± 35.1 AU/m2; p < 0.001 respectively). Differences in calcium score between men and women with AS were not found (3139.8 ± 1494.9 AU vs. 2961.1 ± 1349.5 AU; p = 0.7 respectively).
Comparison of the aortic annulus, the LVOT, the sinus of Valsalva, the STJ and the ascending aorta between the two groups were shown in Table 2 and Fig 2. The average aortic root volume was 17 ± 3.9 cm3 in the study group and 20.6 ± 6.7 cm3 in the control group (p = 0.002) (Fig. 3).
Table 2
Comparison of the aortic annulus, the LVOT, the sinus of Valsalva, the STJ and the ascending aorta dimensions between study and control group
 
Absolute value
Indexed to BSA
Study group (n = 50)
Control group (n = 50)
p value
Study group (n = 50)
Control group (n = 50)
p value
Aortic annulus
 Area (cm2)
4.6 ± 0.7
4.5 ± 1
0.64
2.4 ± 0.4
2.3 ± 0.5
0.33
 Perimeter (mm)
107 ± 143
76 ± 10
0.14
55 ± 6.9
40 ± 5
0.14
 Diameter max (mm)
27.8 ± 2.4
27.2 ± 3.1
0.24
14.7 ± 2
14.1 ± 1.4
0.11
 Diameter min (mm)
21.6 ± 2
21.4 ± 2.5
0.64
11.4 ± 1.5
11.1 ± 1.1
0.34
Left ventricular outflow tract
 Area (cm2)
4.6 ± 1.1
4.4 ± 1.2
0.43
2.4 ± 0.6
2.2 ± 1.06
0.43
 Perimeter (mm)
81 ± 9
79 ± 9
0.31
43 ± 7
41 ± 4
0.15
 Diameter max (mm)
29.5 ± 3.3
29.3 ± 3.2
0.37
15.6 ± 2.6
14.9 ± 2.4
0.2
 Diameter min (mm)
19.8 ± 2.8
19.1 ± 3.4
0.29
10.4 ± 1.8
9.9 ± 1.5
0.13
Sinus of Valsalva
 Area (cm2)
8.2 ± 1
9.3 ± 2
0.002
4.3 ± 1
4.8 ± 1
0.14
 Perimeter (mm)
105 ± 10
114 ± 10
< 0.001
55 ± 10
59 ± 10
0.06
 Diameter, noncoronary cusp (mm)
32.4 ± 4
35.8 ± 5
< 0.001
17.1 ± 3
18.6 ± 3
0.02
 Diameter, left coronary cusp (mm)
33.6 ± 4
35.4 ± 4
0.033
17.7 ± 3
18.4 ± 2
0.14
 Diameter, right coronary cusp (mm)
32.2 ± 3
35.1 ± 4
< 0.001
17 ± 2
18.2 ± 2
0.02
 Height, left side (mm)
19.8 ± 3
20.5 ± 2
0.12
10.4 ± 2
10.7 ± 1
0.31
 Height, right side (mm)
19.7 ± 3
21.1 ± 3
0.02
10.4 ± 2
11 ± 2
0.08
Sino-tubular junction
 Area (cm2)
6.5 ± 1.3
6.9 ± 1.8
0.052
3.4 ± 0.8
3.6 ± 0.9
0.08
 Perimeter (mm)
88.6 ± 11.7
93.3 ± 16.8
0.008
46.7 ± 7.7
48.5 ± 8.5
0.04
 Diameter max (mm)
29 ± 3.1
30 ± 3.3
0.14
15.2 ± 2.2
15.4 ± 1.5
0.56
 Diameter min (mm)
27.9 ± 2.9
29.2 ± 3.3
0.04
14.8 ± 2
15.3 ± 1.6
0.12
Ascending aorta
 Area (cm2)
9.2 ± 2
9 ± 2.1
0.75
4.8 ± 1.1
4.7 ± 1.1
0.89
 Perimeter (mm)
107.6 ± 10.9
105.7 ± 18.1
0.71
56.7 ± 7.8
55 ± 9.9
0.81
 Diameter max (mm)
34.5 ± 3.4
34.4 ± 3.5
0.95
18 ± 2.3
17.8 ± 1.9
0.69
 Diameter min (mm)
33.5 ± 3.5
33.8 ± 3.5
0.73
17.8 ± 2.4
17.7 ± 2
0.81
The aortic annulus was oval (EI > 1.1) in 98% (n = 49 out of 50) of the study group and in 98% (n = 49 out of 50) of the controls. No circular shape of LVOT was observed in both groups. Overall, the ascending aorta and the STJ were circular in most patients in both groups, with oval shapes in 4% (n = 2 out of 50) and 16% (n = 8 out of 50) in the study group and 2% (n = 1 out of 50) and 0% (n = 0 out of 50) in the control group, respectively.
Sex-dependent dimensions of the aortic root were shown in Table 3.
Table 3
Sex-specific dimensions of the aortic root in patients with AS
 
Absolute value
BSA indexed
Male (n = 25)
Female (n = 25)
p value
Male (n = 25)
Female (n = 25)
p value
Aortic annulus
 Area (cm2)
5 ± 0.7
4.2 ± 0.5
< 0.001
2.6 ± 0.4
2.3 ± 0.4
0.03
 Perimeter (mm)
111 ± 146
103 ± 143
0.86
56.7 ± 73
53.5 ± 65
0.87
 Diameter max
28.9 ± 3
26.8 ± 2
0.001
14.9 ± 2
14.4 ± 2
0.44
 Diameter min
22.4 ± 2
20.7 ± 1.4
0.001
11.6 ± 1.6
11.2 ± 1.4
0.39
Left ventricular outflow tract
 Area (cm2)
5.1 ± 1.3
4.2 ± 0.5
0.002
2.6 ± 0.8
2.3 ± 0.4
0.03
 Perimeter (mm)
85.4 ± 10.3
77.4 ± 5.3
0.001
44.1 ± 7.5
41.8 ± 5.7
0.23
 Diameter max
30.4 ± 3.9
28.6 ± 2.4
0.05
15.7 ± 2.9
15.4 ± 2.2
0.67
 Diameter min
20.6 ± 3.4
18.9 ± 1.6
0.02
10.6 ± 2.1
10.2 ± 1.4
0.36
Sinuses of Valsalva
 Area (cm2)
9.1 ± 1.3
7.3 ± 1
< 0.001
4.7 ± 0.8
3.9 ± 0.6
0.001
  Perimeter (mm)
111 ± 8.5
99.2 ± 6.8
< 0.001
57.1 ± 7.3
53.5 ± 6.5
0.07
  Diameter, noncoronary cusp (mm)
33.9 ± 4.2
30.9 ± 2.5
0.003
17.5 ± 2.8
16.6 ± 2
0.23
  Diameter, left coronary cusp
35.2 ± 4.6
32 ± 2.6
0.004
18.1 ± 3
17.3 ± 2.3
0.25
  Diameter, right coronary cusp
33.6 ± 2.9
30.8 ± 2.2
< 0.001
17.3 ± 2.2
16.6 ± 2.1
0.27
  Height, left side (mm)
20.9 ± 2.9
18.6 ± 1.3
0.001
10.7 ± 1.7
10.1 ± 1.4
0.13
  Height, right side (mm)
20.8 ± 3.1
18.7 ± 2.2
0.01
10.7 ± 1.8
10.1 ± 1.7
0.26
  Aortic root volume (cm3)
19.1 ± 3.7
14.9 ± 2.9
< 0.001
9.9 ± 2.2
8 ± 1.6
0.001
Sino-tubular junction
 Area (cm2)
7 ± 1.5
6 ± 1
0.02
3.6 ± 0.9
3.2 ± 0.6
0.22
 Perimeter (mm)
89.5 ± 15
87.7 ± 6.8
0.22
46.2 ± 9.1
47.2 ± 5.9
0.54
 Diameter max
29.9 ± 3.4
28.1 ± 2.4
0.054
15.5 ± 2.6
15 ± 1.8
0.44
 Diameter min
28.8 ± 3.1
27 ± 2.4
0.03
14.8 ± 2.2
14.7 ± 1.7
0.81
Ascending aorta
 Area (cm2)
9.3 ± 2.3
9 ± 1.6
0.9
4.8 ± 1.2
4.8 ± 0.9
0.43
 Perimeter (mm)
108.2 ± 12.5
106.9 ± 8.9
0.83
55.7 ± 8.2
57.6 ± 7.2
0.23
 Diameter max
34.9 ± 3.7
34 ± 3.1
0.63
17.9 ± 2.6
18.1 ± 2
0.77
 Diameter min
34 ± 3.9
33.1 ± 3
0.59
17.6 ± 2.5
18 ± 2.3
0.53
AS men compared with men without AS got smaller sinus of Valsalva with regard to all diameters (33.9 ± 4.2 mm vs. 38.4 ± 3.9 mm; p < 0.001; 35.2 ± 4.6 mm vs. 38.3 ± 3.1 mm; p = 0.008; 33.6 ± 2.9 mm vs. 38.1 ± 2.5 mm; p < 0.001), area (9.1 ± 1.3 cm2 vs. 10.7 ± 1.6 cm2; p < 0.001) and the perimeter (111.1 ± 0.8 mm vs. 123.1 ± 1.1 mm; p < 0.001). Also aortic root volume was smaller in study group (19.1 ± 3.7 cm3 vs. 25.4 ± 5.3 cm3; p<0.001). AS men compared with men without AS got smaller the STJ dimensions with regard to the area, the perimeter and the long axis. There were no significant differences in LVOT, aortic annulus and ascending aorta dimensions (Table 4).
Table 4
Comparison of the aortic annulus, the LVOT, the sinus of Valsalva, the STJ and the ascending aorta dimensions between male with AS and male without AS and between female with AS and female without AS
 
Male AS (n = 25)
Male without AS (n = 25)
p value
Female AS (n = 25)
Female without AS (n = 25)
p value
Aortic annulus
 Area (cm2)
5 ± 0.7
5.1 ± 0.8
0.67
4.2 ± 0.5
3.9 ± 0.9
0.17
 Perimeter (mm)
111 ± 146
83 ± 7
0.34
103 ± 143
70 ± 9
0.25
 Diameter max (mm)
28.9 ± 2.5
29.3 ± 2.7
0.6
26.8 ± 1.7
25.1 ± 1.9
0.002
 Diameter min (mm)
22.4 ± 2.1
23 ± 1.9
0.36
20.7 ± 1.4
19.8 ± 1,9
0.05
Left ventricular outflow tract
 Area (cm2)
5.1 ± 1.3
5.2 ± 1
0.7
4.2 ± 0.5
3.7 ± 0.7
0.005
 Perimeter (mm)
85 ± 10
86 ± 8
0.87
77 ± 5
73 ± 6
0.015
 Diameter max (mm)
30.4 ± 3.9
31.4 ± 2.5
0.96
28.6 ± 2.5
27.2 ± 2.2
0.035
 Diameter min (mm)
20.6 ± 3.4
21.1 ± 2.9
0.6
18.9 ± 1.6
17.1 ± 2.5
0.004
Sinuses of Valsalva
 Area (cm2)
9.1 ± 1,3
10.7 ± 1.6
< 0.001
7.3 ± 1
7.9 ± 1.4
0.022
 Perimeter (mm)
111.1 ± 0.8
123.1 ± 1.1
< 0.001
99.3 ± 6.8
104.6 ± 9.5
0.02
 Diameter, noncoronary cusp (mm)
33.9 ± 4.2
38.4 ± 3.9
< 0.001
30.9 ± 2.5
33.1 ± 3.7
0.018
 Diameter, left coronary cusp (mm)
35.2 ± 4.6
38.3 ± 3.1
0.008
32 ± 2.6
32.5 ± 3
0.55
 Diameter, right coronary cusp (mm)
33.6 ± 2.9
38.1 ± 2.5
< 0.001
30.8 ± 2.2
32.1 ± 2.9
0.094
 Height, left side (mm)
20.9 ± 2.9
20.9 ± 2.9
0.98
18.6 ± 1.3
20.2 ± 1.6
0.001
 Height, right side (mm)
20.8 ± 3.1
22.3 ± 3.1
0.083
18.7 ± 2.2
19.8 ± 2.2
0.08
 Aortic root volume (cm3)
19.1 ± 3.7
25.4 ± 5.3
< 0.001
14.9 ± 2.9
15.9 ± 4
0.34
Sino-tubular junction
 Area (cm2)
7 ± 1.5
7.7 ± 2.1
0.05
6 ± 1
6.2 ± 1.1
0.5
 Perimeter (mm)
89.5 ± 15
97.3 ± 21.7
0.009
87.7 ± 6.8
89.2 ± 8
0.43
 Diameter max (mm)
30 ± 3.4
31.4 ± 3.1
0.006
27.8 ± 2.5
28 ± 2.6
0.63
 Diameter min (mm)
28.8 ± 3.1
31.3 ± 3
0.11
27.3 ± 2.4
27.7 ± 2.8
0.81
Ascending aorta
 Area (cm2)
9.3 ± 2.3
9.4 ± 2.6
0.24
9 ± 1.6
8.7 ± 1.4
0.48
 Perimeter (mm)
108.2 ± 12.5
106.3 ± 24.3
0.25
106.9 ± 8.9
105.1 ± 8
0.45
 Diameter max (mm)
34.7 ± 3.7
35.2 ± 3.8
0.3
33.6 ± 3
33.1 ± 2.7
0.5
 Diameter min (mm)
34.2 ± 4
35 ± 4
0.41
33.5 ± 3.2
33 ± 3.1
0.48
Women with AS compared with women without AS got smaller sinus of Valsalva in terms of the area (7.3 ± 1 cm2 vs. 7.9 ± 1.4 cm2; p = 0.022), the perimeter (99.3 ± 6.8 mm vs. 104.6 ± 9.5 mm; p = 0.02), the noncoronary cusp diameter (30.9 ± 2.5 mm vs. 33.1. ± 3.7 mm; p = 0.018) and the distance of the aortic annulus to the STJ on the left side (18.6 ± 1.3 mm vs. 20.2 ± 1.6 mm; p = 0.001), but aortic root volume was comparable. Contrary to men, AS women compared with controls got a larger LVOT in terms of the area (4.2 ± 0.5 cm2 vs. 3.7 ± 0.7 mm; p = 0.005), the perimeter (77.4 ± 5.3 mm vs. 73.2 ± 6.4 mm; p = 0.015) and diameters (28.6 ± 2.5 mm vs. 27.2 ± 2.2 mm; p = 0.035; 18.9 ± 1.6 mm vs. 17.1 ± 2.5 mm; p = 0.004) and diameters of the aortic annulus (26.8 ± 1.7 mm vs. 25.1 ± 1.9 mm; p = 0.002; 20.7 ± 1.4 mm vs. 19.8 ± 1.9 mm; p = 0.05) (Table 4).

Discussion

Our study assessed calcium score and geometry of the LVOT, the aortic root and the ascending aorta in 50 patients with AS and 50 controls who underwent computed tomography scanning due to clinical indications.
To the best of our knowledge, there is limited data for the comparison of the aortic root geometry between patients with tricuspid AS and patients without stenosis. Our study revealed that patients with tricuspid AS had smaller all dimensions of the sinus of Valsalva as well as a distance between the aortic annulus and the STJ on the right side resulting in a reduction of the aortic root volume compared with patients without stenosis. In the study using 3D transesophageal echocardiography observed reductions of aortic root size in both longitudinal and transverse directions in patients with tricuspid AS and 23% reduction of aortic root volume, but they also described smaller STJ dimensions [7]. Similar to our study, previous studies using MDCT have demonstrated that patients with AS had decreased distance from the aortic valve annulus to the STJ compared with controls, but they denied differences in cross-sectional dimensions of the aortic root [8], while other revealed a transverse remodelling of the aortic root including the diameter of the ascending aorta and the STJ without differences in longitudinal dimensions [9]. While part of previous studies are consistent with our results, there remains also controversy. Discrepancies of study results can be caused by different patient populations, different methodologies or prevalence of aortic regurgitations.
We did not observe differences in ascending aorta dimensions in patients with tricuspid AS compared with controls. The previous studies often reported that aortic stenosis may cause dilatation of the ascending aorta [1012]. Post-stenotic aortic dilatation is defined as dilatation of the vessel wall distal to the area of a partial stenosis [12]. Extension of the aortic root occurs more frequently in patients with AS, aortic regurgitations or bicuspid aortic valve [12, 13]. The widening of the aorta is associated more frequently with bicuspid aortic valve (BAV) than tricuspid aortic stenosis (TAV) [10, 11, 13], which may results from a disorder of a wall structure in patients with BAV [11, 12].
The present study revealed an elipitic shape of the aortic annulus and the LVOT, whereas the STJ and the ascending aorta were more likely to be circular in AS patients as well as in controls. What is more, there were no differences in the Ellipticity Index in the study group compared with patients without AS, except the STJ, which was less frequently circular in the AS group. The shape of the aortic root was sex-independent. Our results are comparable to numerous studies [4, 1416]. One study showed that in contrast to the ascending aorta, which was circular, the annulus and the LVOT were oval in shape, and the elipticity was more pronounced in the LVOT compared with the annulus [4]. Differences in the shape of the aortic root are sex-independent. In systole, the minimal diameter of the aortic annulus increased leading to a decrease in the ellipticity. The annulus assumed a more round shape, thus increasing aortic valve area (AVA) without a substantial change in perimeter [16]. These changes are slight in patients with calcified valves, because tissue properties allow very little changes [16]. The previous study emphasized that a significant oval shape of the aortic annulus may increase the risk of paravalvular leakage after TAVI [14]. The aortic annulus shape is associated with age, with more circular shape in patients younger than 40 years and oval shape in older patients [17].
The components of the aortic root have been described in previous reports but most of these studies assessed only part of the aortic root dimensions, which do not reflect geometry of the aortic root and impact of gender. Our study is one of the few assessment of anatomic dimensions at the various levels of the aortic root, which evaluated aortic root volume and showed sex differences. The age, weight and body surface area were similar in men and women, whereas height and body mass index were larger in men. The present study showed significant sex-dependent differences in the area of the LVOT, the aortic annulus and the sinus of Valsalva and the perimeter of coronary sinus in term of absolute as well as indexed to BSA. Our study showed also that diameters of the LVOT, the aortic annulus and the sinus of Valsalva and the perimeters of LVOT and sinus of Valsalva were larger in men with regard to absolute scores, but indexed values were comparable in both groups. Correlations between patients’ gender and sinus of Valsalva height was not found, but a larger sinus of Valsalva diameter was associated with male gender [18]. Significant differences between men and women were found with regard to the height of the left and right sinus of Valsalva with a larger height for men [9]. Female patients showed also smaller values of the aortic annulus and the sinus of Valsalva, when compared with men, STJ indexed to BSA remained without differences [9]. Our results are also partly consistent with study which revealed larger annulus, LVOT and sinus of Valsalva dimensions in men than in women, whereas dimensions of the ascending aorta were comparable [4].
To the best of our knowledge, there is limited data evaluating differences in aortic root geometry between tricuspid AS patients and healthy controls among women and men. Our study showed that the geometry of the aortic root in women with AS compared to healthy ones shows much more differences than an analogical comparison of men. Men differed from each other by the dimensions of the sinus of Valsalva, the STJ and aortic root volume, while comparison between women with AS and controls showed differences in the sinus of Valsalva, the LVOT, and the aortic annulus, but aortic root volume was comparable. Further research is necessary and our data may contribute to raising awareness of AS etiology.
Our results represent a single-centre study. Selection was biased towards patients with a high cardiac operation risk who were disqualified from surgical aortic replacement, not representative for the overall population of patients with severe aortic stenosis. The small sample size limited comparisons.

Summary

MSCT successfully showed anatomic differences in aortic root geometry in AS patients compared with those without valvular pathology and indentified sex-dependent differences. Significant transverse and longitudinal aortic root remodeling were demonstrated in AS patients compared with controls in contrast to the aortic annulus, the LVOT and the STJ, which did not show differences between both groups. No significant differences in ascending aorta dimensions between tricuspid AS and controls were found. Overall, the aortic annulus and the LVOT were predominantly oval, while the ascending aorta and the STJ were circular in most patients in both groups. Male sex is associated with a greater annulus, a greater LVOT and sinus of Valsalva, but not aortic dimensions. More differences were found between tricuspid AS women and healthy women than in a similar comparison between men. Our study revealed a high variability in the aortic root dimensions between AS patients and healthy controls, which may be relevant for further research into the etiology and pathophysiology of aortic stenosis. What is more, detailed knowledge of the aortic root anatomy in patients with aortic stenosis is crucial for the further improvement of interventional treatment techniques, especially transacatheter aortic valve implantation. Recognition of the sex-dependent aortic root anatomic differences will improve the selection of appropriate systems used for TAVI in particular groups of patients, moreover, it can help identify the group of patients who will benefit most from TAVI. A high variability in the aortic root dimensions require further careful research.

Compliance with ethical standards

Conflict of interest

The authors declare that they have no conflict of interest.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Iung B, Baron G, Butchart EG, Delahaye F, Gohlke-Bärwolf C, Levang OW, Tornos P, Vanoverschelde JV, Vermeer F, Boersma E, Ravaud P, Vahanian A (2003) A prospective survey of patients with valvular heart disease in Europe: the Euro Heart Survey on Valvular Heart Disease. Eur Heart J 24(13):1231–1243CrossRef Iung B, Baron G, Butchart EG, Delahaye F, Gohlke-Bärwolf C, Levang OW, Tornos P, Vanoverschelde JV, Vermeer F, Boersma E, Ravaud P, Vahanian A (2003) A prospective survey of patients with valvular heart disease in Europe: the Euro Heart Survey on Valvular Heart Disease. Eur Heart J 24(13):1231–1243CrossRef
2.
Zurück zum Zitat Baumgartner H, Falk V, Bax JJ, De Bonis M, Hamm C, Holm PJ, Iung B, Lancellotti P, Lansac E, Rodriguez Muñoz D, Rosenhek R, Sjögren J, Tornos Mas P, Vahanian A, Walther T, Wendler O, Windecker S, Zamorano JL (2017) 2017 ESC/EACTSGuidelines for the management of valvular heart disease. The Task Force for the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J 38(36):2739–2791CrossRef Baumgartner H, Falk V, Bax JJ, De Bonis M, Hamm C, Holm PJ, Iung B, Lancellotti P, Lansac E, Rodriguez Muñoz D, Rosenhek R, Sjögren J, Tornos Mas P, Vahanian A, Walther T, Wendler O, Windecker S, Zamorano JL (2017) 2017 ESC/EACTSGuidelines for the management of valvular heart disease. The Task Force for the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur Heart J 38(36):2739–2791CrossRef
3.
Zurück zum Zitat Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circulation 1(1):74–81PubMed Piazza N, de Jaegere P, Schultz C, Becker AE, Serruys PW, Anderson RH (2008) Anatomy of the aortic valvar complex and its implications for transcatheter implantation of the aortic valve. Circulation 1(1):74–81PubMed
4.
Zurück zum Zitat Buellesfeld L, Stortecky S, Kalesan B, Gloekler S, Khattab AA, Nietlispach F, Delfine V, Huber C, Eberle B, Meier B, Wenaweser P, Windecker S (2013) Aortic root dimensions among patients with severe aortic stenosis undergoing transcatheter aortic valve replacement. JACC Cardiovasc Interv 6(1):72–83CrossRef Buellesfeld L, Stortecky S, Kalesan B, Gloekler S, Khattab AA, Nietlispach F, Delfine V, Huber C, Eberle B, Meier B, Wenaweser P, Windecker S (2013) Aortic root dimensions among patients with severe aortic stenosis undergoing transcatheter aortic valve replacement. JACC Cardiovasc Interv 6(1):72–83CrossRef
5.
Zurück zum Zitat Clavel MA, Messika-Zeitoun D, Pibarot P, Aggarwal SR, Malouf J, Araoz PA, Michelena HI, Cueff C, Larose E, Capoulade R, Vahanian A, Enriquez-Sarano M (2013) The complex nature of discordant severe calcified aortic valve disease grading: new insights from combined doppler echocardiographic and computed tomographic study. J Am Coll Cardiol 62(24):2329–2338CrossRef Clavel MA, Messika-Zeitoun D, Pibarot P, Aggarwal SR, Malouf J, Araoz PA, Michelena HI, Cueff C, Larose E, Capoulade R, Vahanian A, Enriquez-Sarano M (2013) The complex nature of discordant severe calcified aortic valve disease grading: new insights from combined doppler echocardiographic and computed tomographic study. J Am Coll Cardiol 62(24):2329–2338CrossRef
6.
Zurück zum Zitat Jurencak T, Turek J, Kietselaer BLJH, Mihl C, Kok M, Ommen VGVA, Garsse LAFM, Nijssen EC, Wildberger JE, Das M (2015) MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle? Eur Radiol 25(7):1975–1983CrossRef Jurencak T, Turek J, Kietselaer BLJH, Mihl C, Kok M, Ommen VGVA, Garsse LAFM, Nijssen EC, Wildberger JE, Das M (2015) MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle? Eur Radiol 25(7):1975–1983CrossRef
7.
Zurück zum Zitat Chien-Chia WuV, Kaku K, Takeuchi M, Otani K, Yoshitani H, Tamura M, Abe H, Lin FC, Otsuji Y (2014) Aortic root geometry in patients with aortic stenosis assessed by real-time three-dimensional transesophageal echocardiography. J Am Soc Echocardiogr 27(1):32–41CrossRef Chien-Chia WuV, Kaku K, Takeuchi M, Otani K, Yoshitani H, Tamura M, Abe H, Lin FC, Otsuji Y (2014) Aortic root geometry in patients with aortic stenosis assessed by real-time three-dimensional transesophageal echocardiography. J Am Soc Echocardiogr 27(1):32–41CrossRef
8.
Zurück zum Zitat Akhtar M, Tuzcu EM, Kapadia SR, Svensson LG, Greenberg RK, Roselli EE, Halliburton S, Kurra V, Schoenhagen P, Sola S (2009) Aortic root morphology in patients undergoing percutaneous aortic valve replacement: evidence of aortic root remodeling. J Thorac Cardiovasc Surg 137(4):950–956CrossRef Akhtar M, Tuzcu EM, Kapadia SR, Svensson LG, Greenberg RK, Roselli EE, Halliburton S, Kurra V, Schoenhagen P, Sola S (2009) Aortic root morphology in patients undergoing percutaneous aortic valve replacement: evidence of aortic root remodeling. J Thorac Cardiovasc Surg 137(4):950–956CrossRef
9.
Zurück zum Zitat Stolzmann P, Knight J, Desbiolles L, Maier W, Scheffel H, Plass A, Kurtcuoglu V, Leschka S, Poulikakos D, Marincek B, lkadhi H (2009) Remodelling of the aortic root in severe tricuspid aortic stenosis: implications for transcatheter aortic valve implantation. Eur Radiol 19(6):1316–1323CrossRef Stolzmann P, Knight J, Desbiolles L, Maier W, Scheffel H, Plass A, Kurtcuoglu V, Leschka S, Poulikakos D, Marincek B, lkadhi H (2009) Remodelling of the aortic root in severe tricuspid aortic stenosis: implications for transcatheter aortic valve implantation. Eur Radiol 19(6):1316–1323CrossRef
10.
Zurück zum Zitat Keane MG, Wiegers SE, Plappert T, Pochettino A, Bavaria JE, St MG, Sutton J (2000) Bicuspid aortic valves are associated with aortic dilatation out of proportion to coexistent valvular lesions. Circulation 102(19 Suppl 3):III35–III39PubMed Keane MG, Wiegers SE, Plappert T, Pochettino A, Bavaria JE, St MG, Sutton J (2000) Bicuspid aortic valves are associated with aortic dilatation out of proportion to coexistent valvular lesions. Circulation 102(19 Suppl 3):III35–III39PubMed
11.
Zurück zum Zitat Ruzmetov M, Shah JJ, Fortuna RS, Welke KF (2015) The Association between Aortic Valve Leaflet Morphology and Patterns of Aortic Dilation in Patients with Bicuspid Aortic Valves. Ann Thorac Surg 99(6):2101–2108CrossRef Ruzmetov M, Shah JJ, Fortuna RS, Welke KF (2015) The Association between Aortic Valve Leaflet Morphology and Patterns of Aortic Dilation in Patients with Bicuspid Aortic Valves. Ann Thorac Surg 99(6):2101–2108CrossRef
12.
Zurück zum Zitat Wilton E, Jahangiri M (2006) Post-stenotic aortic dilatation. J Cardiothorac Surg 1(1):1–11CrossRef Wilton E, Jahangiri M (2006) Post-stenotic aortic dilatation. J Cardiothorac Surg 1(1):1–11CrossRef
13.
Zurück zum Zitat Hanis I, Linhartová K, Beránek V, Sefrna F, Hanisová I, Sterbáková G, Pesková M (2007) Aortic stenosis severity is not a risk factor for poststenotic dilatation of the ascending aorta. Circ J 71(1):84–88CrossRef Hanis I, Linhartová K, Beránek V, Sefrna F, Hanisová I, Sterbáková G, Pesková M (2007) Aortic stenosis severity is not a risk factor for poststenotic dilatation of the ascending aorta. Circ J 71(1):84–88CrossRef
14.
Zurück zum Zitat Tops LF, Wood DA, Delgado V, Schuijf JD, Mayo JR, Pasupati S, Lamers FPL, van der Wall EE, Schalij MJ, Webb JG, Bax JJ (2008) Noninvasive evaluation of the aortic root with multislice computed tomography. Implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1(3):321–330CrossRef Tops LF, Wood DA, Delgado V, Schuijf JD, Mayo JR, Pasupati S, Lamers FPL, van der Wall EE, Schalij MJ, Webb JG, Bax JJ (2008) Noninvasive evaluation of the aortic root with multislice computed tomography. Implications for transcatheter aortic valve replacement. JACC Cardiovasc Imaging 1(3):321–330CrossRef
15.
Zurück zum Zitat Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, Makhija R, Doctor N, Leon MB, Makkar RR (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59(14):1275–1286CrossRef Jilaihawi H, Kashif M, Fontana G, Furugen A, Shiota T, Friede G, Makhija R, Doctor N, Leon MB, Makkar RR (2012) Cross-sectional computed tomographic assessment improves accuracy of aortic annular sizing for transcatheter aortic valve replacement and reduces the incidence of paravalvular aortic regurgitation. J Am Coll Cardiol 59(14):1275–1286CrossRef
16.
Zurück zum Zitat Hamdan A, Guetta V, Konen E, Goitein O, Segev A, Raanani E, Spiegelstein D, Hay I, Segni ED, Eldar M, Schwammenthal E (2012) Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 59(2):119–127CrossRef Hamdan A, Guetta V, Konen E, Goitein O, Segev A, Raanani E, Spiegelstein D, Hay I, Segni ED, Eldar M, Schwammenthal E (2012) Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy. J Am Coll Cardiol 59(2):119–127CrossRef
17.
Zurück zum Zitat Oshita C, Murata K, Wada Y, Nao T, Uchida K, Okuda S, Susa T, Tanaka N, Matsuzaki M, Yano M (2014) Assessment of the aortic valve annular geometry by real-time three-dimensional transthoracic echocardiography: comparison with two-dimensional transthoracic echocardiography and multidetector computed tomography. J Echocardiogr 12(1):24–30CrossRef Oshita C, Murata K, Wada Y, Nao T, Uchida K, Okuda S, Susa T, Tanaka N, Matsuzaki M, Yano M (2014) Assessment of the aortic valve annular geometry by real-time three-dimensional transthoracic echocardiography: comparison with two-dimensional transthoracic echocardiography and multidetector computed tomography. J Echocardiogr 12(1):24–30CrossRef
18.
Zurück zum Zitat Bahlmann E, Nienaber CA, Cramariuc D, Gohlke-Baerwolf C, Ray S, Devereux RB, Wachtell K, Kuck KH, Davidsen E, Gerdts E (2011) Aortic root geometry in aortic stenosis patients (a SEAS Substudy). Eur J Echocardiogr 12(8):585–590CrossRef Bahlmann E, Nienaber CA, Cramariuc D, Gohlke-Baerwolf C, Ray S, Devereux RB, Wachtell K, Kuck KH, Davidsen E, Gerdts E (2011) Aortic root geometry in aortic stenosis patients (a SEAS Substudy). Eur J Echocardiogr 12(8):585–590CrossRef
Metadaten
Titel
Comparison of the geometry of the left ventricle outflow tract, the aortic root and the ascending aorta in patients with severe tricuspid aortic stenosis versus healthy controls
verfasst von
Małgorzata Nieznańska
Karina Zatorska
Patrycjusz Stokłosa
Małgorzata Ryś
Piotr Duchnowski
Piotr Szymański
Tomasz Hryniewiecki
Ilona Michałowska
Publikationsdatum
04.11.2019
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 2/2020
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-019-01715-5

Weitere Artikel der Ausgabe 2/2020

The International Journal of Cardiovascular Imaging 2/2020 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.