Skip to main content
Erschienen in: Heart and Vessels 4/2019

03.11.2018 | Original Article

Comparison of the vessel healing process after everolimus-eluting stent and bare metal stent implantations in patients with ST-elevation myocardial infarction

verfasst von: Hideki Yano, Shigeo Horinaka, Manami Watahik, Tomoko Watanabe, Toshihiko Ishimitsu

Erschienen in: Heart and Vessels | Ausgabe 4/2019

Einloggen, um Zugang zu erhalten

Abstract

Cobalt–chromium everolimus-eluting stent (CoCr EES) is associated with a lower rate of stent thrombosis even in patients with ST-elevation myocardial infarction (STEMI). However, the time-serial changes of endothelial coverage of the stent struts in the extremely early period have never been reported, especially in patients with STEMI. The aim of this study was to compare the vessel healing process between CoCr EES and cobalt–chromium bare metal stent (CoCr BMS) implantations using optical coherence tomography (OCT) in patients with STEMI. Sixty-three patients who had primary emergent percutaneous coronary intervention (PCI) with CoCr EES (42 patients) or CoCr BMS (21 patients) were enrolled in this study for 3 years. OCT was performed just after, 2 and 12 weeks after EES or BMS implantations. Time-serial changes in the neointimal coverage (NIC), the neointimal thickness, and malapposition of stent struts were evaluated. NIC of stent struts did not differ between CoCr EES (23.2%, 99.4%) and CoCr BMS (24.0%, 97.8%) at 2 weeks and 12 weeks after PCI, respectively. Thicknesses of the neointima on the stent strut was significantly thinner in CoCr EES (34.0 ± 13.8, 107.0 ± 32.4 µm) than in CoCr BMS (40.0 ± 14.6, 115.7 ± 33.8 µm) at 2 weeks and 12 weeks after PCI (= 0.011, p = 0.008), respectively. The malapposition did not differ just after PCI, and was completely resolved at 12 weeks after PCI in both groups. Thrombus was significantly less in CoCr EES than in CoCr BMS at 2 weeks (19.0% vs 42.9%, p < 0.01), and decreased over time in both groups, but at 12 weeks, disappeared only in CoCr EES (CoCr EES: 0% vs. CoCr BMS: 4.8%, p = 0.56). This study demonstrated that NIC and apposition of the stent struts almost completed at 12 weeks after EES and BMS implantations, while the neointimal thickness on the stent struts were thinner in EES than in BMS. Moreover, thrombus was significantly less in EES than in BMS implantations 2 weeks after PCI, which may explain the lower rate of acute and subacute stent thrombosis of EES compared with BMS.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Horst B, Rihal CS, Holmes DR Jr, Bresnahan JF, Prasad A, Gau G, Lennon R, Lerman A (2009) Comparison of drug-eluting and bare-metal stents for stable coronary artery disease. JACC Cardiovasc Interv 2:321–328CrossRefPubMed Horst B, Rihal CS, Holmes DR Jr, Bresnahan JF, Prasad A, Gau G, Lennon R, Lerman A (2009) Comparison of drug-eluting and bare-metal stents for stable coronary artery disease. JACC Cardiovasc Interv 2:321–328CrossRefPubMed
2.
Zurück zum Zitat Stettler C, Wandel S, Allemann S, Kastrati A, Morice MC, Schömig A, Pfisterer ME, Stone GW, Leon MB, de Lezo JS, Goy JJ, Park SJ, Sabaté M, Suttorp MJ, Kelbaek H, Spaulding C, Menichelli M, Vermeersch P, Dirksen MT, Cervinka P, Petronio AS, Nordmann AJ, Diem P, Meier B, Zwahlen M, Reichenbach S, Trelle S, Windecker S, Jüni P (2007) Outcomes associated with drug-eluting and bare-metal stents: a collaborative network metaanalysis. Lancet 370:937–948CrossRefPubMed Stettler C, Wandel S, Allemann S, Kastrati A, Morice MC, Schömig A, Pfisterer ME, Stone GW, Leon MB, de Lezo JS, Goy JJ, Park SJ, Sabaté M, Suttorp MJ, Kelbaek H, Spaulding C, Menichelli M, Vermeersch P, Dirksen MT, Cervinka P, Petronio AS, Nordmann AJ, Diem P, Meier B, Zwahlen M, Reichenbach S, Trelle S, Windecker S, Jüni P (2007) Outcomes associated with drug-eluting and bare-metal stents: a collaborative network metaanalysis. Lancet 370:937–948CrossRefPubMed
3.
Zurück zum Zitat Babapulle MN, Joseph L, Belisle P, Brophy JM, Eisenberg MJ (2004) A hierarchical Bayesian meta-analysis of randomized clinical trials of drug-eluting stents. Lancet 364:583–591CrossRefPubMed Babapulle MN, Joseph L, Belisle P, Brophy JM, Eisenberg MJ (2004) A hierarchical Bayesian meta-analysis of randomized clinical trials of drug-eluting stents. Lancet 364:583–591CrossRefPubMed
4.
Zurück zum Zitat Jeremias A, Sylvia B, Bridges J, Kirtane AJ, Bigelow B, Pinto DS, Ho KK, Cohen DJ, Garcia LA, Cutlip DE, Carrozza JP Jr (2004) Stent thrombosis after successful sirolimus-eluting stent implantation. Circulation 109:1930–1932CrossRefPubMed Jeremias A, Sylvia B, Bridges J, Kirtane AJ, Bigelow B, Pinto DS, Ho KK, Cohen DJ, Garcia LA, Cutlip DE, Carrozza JP Jr (2004) Stent thrombosis after successful sirolimus-eluting stent implantation. Circulation 109:1930–1932CrossRefPubMed
5.
Zurück zum Zitat Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48:193–202CrossRef Joner M, Finn AV, Farb A, Mont EK, Kolodgie FD, Ladich E, Kutys R, Skorija K, Gold HK, Virmani R (2006) Pathology of drug-eluting stents in humans: delayed healing and late thrombotic risk. J Am Coll Cardiol 48:193–202CrossRef
6.
Zurück zum Zitat Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, Mihalcsik L, Tespili M, Valsecchi O, Kolodgie FD (2004) Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 109:701–705CrossRefPubMed Virmani R, Guagliumi G, Farb A, Musumeci G, Grieco N, Motta T, Mihalcsik L, Tespili M, Valsecchi O, Kolodgie FD (2004) Localized hypersensitivity and late coronary thrombosis secondary to a sirolimus-eluting stent: should we be cautious? Circulation 109:701–705CrossRefPubMed
7.
Zurück zum Zitat Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drugeluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441CrossRefPubMed Finn AV, Joner M, Nakazawa G, Kolodgie F, Newell J, John MC, Gold HK, Virmani R (2007) Pathological correlates of late drugeluting stent thrombosis: strut coverage as a marker of endothelialization. Circulation 115:2435–2441CrossRefPubMed
8.
Zurück zum Zitat Sheiban I, Villata G, Bollati M, Sillano D, Lotrionte M, Biondi-Zoccai G (2008) Next-generation drug-eluting stents in coronary artery disease: focus on everolimus-eluting stent (Xience V). Vasc Health Risk Manag 4:31–38CrossRefPubMedPubMedCentral Sheiban I, Villata G, Bollati M, Sillano D, Lotrionte M, Biondi-Zoccai G (2008) Next-generation drug-eluting stents in coronary artery disease: focus on everolimus-eluting stent (Xience V). Vasc Health Risk Manag 4:31–38CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Serruys PW, Ruygrok P, Neuzner J, Piek JJ, Seth A, Schofer JJ, Richardt G, Wiemer M, Carrié D, Thuesen L, Boone E, Miquel-Herbert K, Daemen J (2006) A randomized comparison of an everolimus-eluting coronary stent with a paclitaxel-eluting coronary stent: the SPIRIT II trial. EuroIntervention 2:286–294 Serruys PW, Ruygrok P, Neuzner J, Piek JJ, Seth A, Schofer JJ, Richardt G, Wiemer M, Carrié D, Thuesen L, Boone E, Miquel-Herbert K, Daemen J (2006) A randomized comparison of an everolimus-eluting coronary stent with a paclitaxel-eluting coronary stent: the SPIRIT II trial. EuroIntervention 2:286–294
10.
Zurück zum Zitat Planer D, Smits PC, Kereiakes DJ, Kedhi E, Fahy M, Xu K, Serruys PW, Stone GW (2011) Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials. JACC Cardiovasc Interv 4:1104–1115CrossRefPubMed Planer D, Smits PC, Kereiakes DJ, Kedhi E, Fahy M, Xu K, Serruys PW, Stone GW (2011) Comparison of everolimus- and paclitaxel-eluting stents in patients with acute and stable coronary syndromes: pooled results from the SPIRIT (A Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) and COMPARE (A Trial of Everolimus-Eluting Stents and Paclitaxel-Eluting Stents for Coronary Revascularization in Daily Practice) trials. JACC Cardiovasc Interv 4:1104–1115CrossRefPubMed
11.
Zurück zum Zitat Farb A, Burke AP, Kolodgie FD, Virmani R (2003) Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 108:1701–1706CrossRefPubMed Farb A, Burke AP, Kolodgie FD, Virmani R (2003) Pathological mechanisms of fatal late coronary stent thrombosis in humans. Circulation 108:1701–1706CrossRefPubMed
12.
Zurück zum Zitat Palmerini T, Sangiorgi D, Valgimigli M, Biondi-Zoccai G, Feres F, Abizaid A, Costa RA, Hong MK, Kim BK, Jang Y, Kim HS, Park KW, Mariani A, Della Riva D, Genereux P, Leon MB, Bhatt DL, Bendetto U, Rapezzi C, Stone GW (2015) Short-versus long-term dual antiplatelet therapy after drug-eluting stent implantation: an individual patient data pairwise and network meta-analysis. J Am Coll Cardiol 65:1092–1102CrossRefPubMed Palmerini T, Sangiorgi D, Valgimigli M, Biondi-Zoccai G, Feres F, Abizaid A, Costa RA, Hong MK, Kim BK, Jang Y, Kim HS, Park KW, Mariani A, Della Riva D, Genereux P, Leon MB, Bhatt DL, Bendetto U, Rapezzi C, Stone GW (2015) Short-versus long-term dual antiplatelet therapy after drug-eluting stent implantation: an individual patient data pairwise and network meta-analysis. J Am Coll Cardiol 65:1092–1102CrossRefPubMed
13.
Zurück zum Zitat Giustino G, Baber U, Sartori S, Mehran R, Mastoris I, Kini AS, Sharma SK, Pocock SJ, Dangas GD (2015) Duration of dual antiplatelet therapy after drug-eluting stent implantation: a systematic review and meta-analysis of randomized controlled trials. J Am Coll Cardiol 65:1298–1310CrossRefPubMed Giustino G, Baber U, Sartori S, Mehran R, Mastoris I, Kini AS, Sharma SK, Pocock SJ, Dangas GD (2015) Duration of dual antiplatelet therapy after drug-eluting stent implantation: a systematic review and meta-analysis of randomized controlled trials. J Am Coll Cardiol 65:1298–1310CrossRefPubMed
14.
Zurück zum Zitat Kim BK, Hong MK, Shin DH, Nam CM, Kim JS, Ko YG, Choi D, Kang TS, Park BE, Kang WC, Lee SH, Yoon JH, Hong BK, Kwon HM, Jang Y, Investigators RESET (2012) A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet therapy following Endeavor zotarolimus-eluting stent implantation). J Am Coll Cardiol 2012(60):1340–1348CrossRef Kim BK, Hong MK, Shin DH, Nam CM, Kim JS, Ko YG, Choi D, Kang TS, Park BE, Kang WC, Lee SH, Yoon JH, Hong BK, Kwon HM, Jang Y, Investigators RESET (2012) A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet therapy following Endeavor zotarolimus-eluting stent implantation). J Am Coll Cardiol 2012(60):1340–1348CrossRef
15.
Zurück zum Zitat Yano H, Horinaka S, Ishikawa M, Ishimitsu T (2017) Early vascular responses after everolimus-eluting stent implantation assessed by serial observations of intracoronary optical coherence tomography. Heart Vessels 32:804–812CrossRefPubMed Yano H, Horinaka S, Ishikawa M, Ishimitsu T (2017) Early vascular responses after everolimus-eluting stent implantation assessed by serial observations of intracoronary optical coherence tomography. Heart Vessels 32:804–812CrossRefPubMed
16.
Zurück zum Zitat van Werkum JW, Heestermans AA, Zomer AC, Kelder JC, Suttorp MJ, Rensing BJ, Koolen JJ, Brueren BR, Dambrink JH, Hautvast RW, Verheugt FW, ten Berg JM (2009) Predictors of coronary stent thrombosis: the Dutch Stent thrombosis registry. J Am Coll Cardiol 53:1399–1409CrossRefPubMed van Werkum JW, Heestermans AA, Zomer AC, Kelder JC, Suttorp MJ, Rensing BJ, Koolen JJ, Brueren BR, Dambrink JH, Hautvast RW, Verheugt FW, ten Berg JM (2009) Predictors of coronary stent thrombosis: the Dutch Stent thrombosis registry. J Am Coll Cardiol 53:1399–1409CrossRefPubMed
17.
Zurück zum Zitat Dangas GD, Caixeta A, Mehran R, Parise H, Lansky AJ, Cristea E, Brodie BR, Witzenbichler B, Guagliumi G, Peruga JZ, Dudek D, Möeckel M, Stone GW, Harmonizing Outcomes with Revascularization Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial Investigators (2011) Frequency and predictors of stent thrombosis after percutaneous coronary intervention in acute myocardial infarction. Circulation 123:1745–1756CrossRefPubMed Dangas GD, Caixeta A, Mehran R, Parise H, Lansky AJ, Cristea E, Brodie BR, Witzenbichler B, Guagliumi G, Peruga JZ, Dudek D, Möeckel M, Stone GW, Harmonizing Outcomes with Revascularization Stents in Acute Myocardial Infarction (HORIZONS-AMI) Trial Investigators (2011) Frequency and predictors of stent thrombosis after percutaneous coronary intervention in acute myocardial infarction. Circulation 123:1745–1756CrossRefPubMed
18.
Zurück zum Zitat Feres F, Costa RA, Abizaid A, Leon MB, Marin-Neto JA, Botelho RV, King SB 3rd, Negoita M, Liu M, de Paula JE, Mangione JA, Meireles GX, Castello HJ Jr, Nicolela EL Jr, Perin MA, Devito FS, Labrunie A, Salvadori D Jr, Gusmão M, Staico R, Costa JR Jr, de Castro JP, Abizaid AS, Bhatt DL, Trial Investigators OPTIMIZE (2013) Three vs twelve months of dual antiplatelet therapy after zotarolimus-eluting stents: the OPTIMIZE randomized trial. JAMA 310:2510–2522PubMed Feres F, Costa RA, Abizaid A, Leon MB, Marin-Neto JA, Botelho RV, King SB 3rd, Negoita M, Liu M, de Paula JE, Mangione JA, Meireles GX, Castello HJ Jr, Nicolela EL Jr, Perin MA, Devito FS, Labrunie A, Salvadori D Jr, Gusmão M, Staico R, Costa JR Jr, de Castro JP, Abizaid AS, Bhatt DL, Trial Investigators OPTIMIZE (2013) Three vs twelve months of dual antiplatelet therapy after zotarolimus-eluting stents: the OPTIMIZE randomized trial. JAMA 310:2510–2522PubMed
19.
Zurück zum Zitat de Jaegere P, Mudra H, Figulla H, Almagor Y, Doucet S, Penn I, Colombo A, Hamm C, Bartorelli A, Rothman M, Nobuyoshi M, Yamaguchi T, Voudris V, DiMario C, Makovski S, Hausmann D, Rowe S, Rabinovich S, Sunamura M, van Es GA (1998) Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study). Eur Heart J 19:1214–1223CrossRefPubMed de Jaegere P, Mudra H, Figulla H, Almagor Y, Doucet S, Penn I, Colombo A, Hamm C, Bartorelli A, Rothman M, Nobuyoshi M, Yamaguchi T, Voudris V, DiMario C, Makovski S, Hausmann D, Rowe S, Rabinovich S, Sunamura M, van Es GA (1998) Intravascular ultrasound-guided optimized stent deployment. Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study). Eur Heart J 19:1214–1223CrossRefPubMed
20.
Zurück zum Zitat Imola F, Mallus MT, Ramazzotti V, Manzoli A, Pappalardo A, Di Giorgio A, Albertucci M, Prati F (2010) Safety and feasibility of frequency domain optical coherence tomography to guide decision making in percutaneous coronary intervention. EuroIntervention 6:575–581CrossRefPubMed Imola F, Mallus MT, Ramazzotti V, Manzoli A, Pappalardo A, Di Giorgio A, Albertucci M, Prati F (2010) Safety and feasibility of frequency domain optical coherence tomography to guide decision making in percutaneous coronary intervention. EuroIntervention 6:575–581CrossRefPubMed
21.
Zurück zum Zitat Gonzalo N, Serruys PW, Okamura T, Shen ZJ, Onuma Y, Garcia-Garcia HM, Sarno G, Schultz C, van Geuns RJ, Ligthart J, Regar E (2009) Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach. Heart 95:1913–1919CrossRefPubMed Gonzalo N, Serruys PW, Okamura T, Shen ZJ, Onuma Y, Garcia-Garcia HM, Sarno G, Schultz C, van Geuns RJ, Ligthart J, Regar E (2009) Optical coherence tomography assessment of the acute effects of stent implantation on the vessel wall: a systematic quantitative approach. Heart 95:1913–1919CrossRefPubMed
22.
Zurück zum Zitat Gutiérrez-Chico JL, Alegría-Barrero E, Teijeiro-Mestre R, Chan PH, Tsujioka H, de Silva R, Viceconte N, Lindsay A, Patterson T, Foin N, Akasaka T, di Mario C (2012) Optical coherence tomography: from research to practice. Eur Heart J Cardiovasc Imaging 13:370–384CrossRefPubMedPubMedCentral Gutiérrez-Chico JL, Alegría-Barrero E, Teijeiro-Mestre R, Chan PH, Tsujioka H, de Silva R, Viceconte N, Lindsay A, Patterson T, Foin N, Akasaka T, di Mario C (2012) Optical coherence tomography: from research to practice. Eur Heart J Cardiovasc Imaging 13:370–384CrossRefPubMedPubMedCentral
23.
Zurück zum Zitat Tanaka N, Terashima M, Rathore S, Itoh T, Habara M, Nasu K, Kimura M, Itoh T, Kinoshita Y, Ehara M, Tsuchikane E, Asakura K, Asakura Y, Katoh O, Suzuki T (2010) Different patterns of vascular response between patients with or without diabetes mellitus after drug-eluting stent implantation: optical coherence tomographic analysis. JACC Cardiovasc Interv 3:1074–1079CrossRefPubMed Tanaka N, Terashima M, Rathore S, Itoh T, Habara M, Nasu K, Kimura M, Itoh T, Kinoshita Y, Ehara M, Tsuchikane E, Asakura K, Asakura Y, Katoh O, Suzuki T (2010) Different patterns of vascular response between patients with or without diabetes mellitus after drug-eluting stent implantation: optical coherence tomographic analysis. JACC Cardiovasc Interv 3:1074–1079CrossRefPubMed
24.
Zurück zum Zitat Joner M, Nakazawa G, Finn AV, Quee SC, Coleman L, Acampado E, Wilson PS, Skorija K, Cheng Q, Xu X, Gold HK, Kolodgie FD, Virmani R (2008) Endothelial cell recovery between comparator polymer-based drug-eluting stents. J Am Coll Cardiol 52:333–342CrossRefPubMed Joner M, Nakazawa G, Finn AV, Quee SC, Coleman L, Acampado E, Wilson PS, Skorija K, Cheng Q, Xu X, Gold HK, Kolodgie FD, Virmani R (2008) Endothelial cell recovery between comparator polymer-based drug-eluting stents. J Am Coll Cardiol 52:333–342CrossRefPubMed
25.
Zurück zum Zitat Takano M, Yamamoto M, Mizuno M, Murakami D, Inami T, Kimata N, Murai K, Kobayashi N, Okamatsu K, Ohba T, Seino Y, Mizuno K (2010) Late vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: serial observations by intracoronary optical coherence tomography. Circ Cardiovasc Interv 3:476–483CrossRefPubMed Takano M, Yamamoto M, Mizuno M, Murakami D, Inami T, Kimata N, Murai K, Kobayashi N, Okamatsu K, Ohba T, Seino Y, Mizuno K (2010) Late vascular responses from 2 to 4 years after implantation of sirolimus-eluting stents: serial observations by intracoronary optical coherence tomography. Circ Cardiovasc Interv 3:476–483CrossRefPubMed
26.
Zurück zum Zitat Katoh H, Shite J, Shinke T, Matsumoto D, Tanino Y, Ogasawara D, Sawada T, Miyoshi N, Kawamori H, Yoshino N, Hirata K (2009) Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography. Circ J 73:1033–1037CrossRefPubMed Katoh H, Shite J, Shinke T, Matsumoto D, Tanino Y, Ogasawara D, Sawada T, Miyoshi N, Kawamori H, Yoshino N, Hirata K (2009) Delayed neointimalization on sirolimus-eluting stents: 6-month and 12-month follow up by optical coherence tomography. Circ J 73:1033–1037CrossRefPubMed
27.
Zurück zum Zitat Yano H, Horinaka S, Ishikawa M, Ishimitsu T (2017) Early vascular responses after everolimus-eluting stent implantation assessed by serial observations of intracoronary optical coherence tomography. Heart Vessels 32:804–812CrossRefPubMed Yano H, Horinaka S, Ishikawa M, Ishimitsu T (2017) Early vascular responses after everolimus-eluting stent implantation assessed by serial observations of intracoronary optical coherence tomography. Heart Vessels 32:804–812CrossRefPubMed
28.
Zurück zum Zitat Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717CrossRefPubMed Kume T, Akasaka T, Kawamoto T, Ogasawara Y, Watanabe N, Toyota E, Neishi Y, Sukmawan R, Sadahira Y, Yoshida K (2006) Assessment of coronary arterial thrombus by optical coherence tomography. Am J Cardiol 97:1713–1717CrossRefPubMed
29.
Zurück zum Zitat Tanigawa J, Barlis P, Di Mario C (2007) Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. EuroIntervention 3:128–136PubMed Tanigawa J, Barlis P, Di Mario C (2007) Intravascular optical coherence tomography: optimisation of image acquisition and quantitative assessment of stent strut apposition. EuroIntervention 3:128–136PubMed
30.
Zurück zum Zitat Kim J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C (2009) The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol 134:180–188CrossRef Kim J, Barlis P, Dimopoulos K, Dalby M, Moore P, Di Mario C (2009) The influence of strut thickness and cell design on immediate apposition of drug-eluting stents assessed by optical coherence tomography. Int J Cardiol 134:180–188CrossRef
31.
Zurück zum Zitat Kim TH, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK (2011) Long-term (%3e2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: comparison to 9-month follow-up results. Int J Cardiovasc Imaging 27:875–881CrossRefPubMed Kim TH, Kim JS, Kim BK, Ko YG, Choi D, Jang Y, Hong MK (2011) Long-term (%3e2 years) follow-up optical coherence tomographic study after sirolimus- and paclitaxel-eluting stent implantation: comparison to 9-month follow-up results. Int J Cardiovasc Imaging 27:875–881CrossRefPubMed
32.
Zurück zum Zitat Awata M, Kotani J, Uematsu M, Morozumi T, Watanabe T, Onishi T, Iida O, Sera F, Nanto S, Hori M, Nagata S (2007) Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: comparison with bare-metal stents. Circulation 116:910–916CrossRefPubMed Awata M, Kotani J, Uematsu M, Morozumi T, Watanabe T, Onishi T, Iida O, Sera F, Nanto S, Hori M, Nagata S (2007) Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation: comparison with bare-metal stents. Circulation 116:910–916CrossRefPubMed
33.
Zurück zum Zitat Takano M, Yamamoto M, Xie Y, Murakami D, Inami S, Okamatsu K, Seimiya K, Ohba T, Seino Y, Mizuno K (2007) Serial long-term evaluation of neointimal stent coverage and thrombus after sirolimus-eluting stent implantation by use of coronary angioscopy. Heart 93:1533–1536CrossRefPubMedPubMedCentral Takano M, Yamamoto M, Xie Y, Murakami D, Inami S, Okamatsu K, Seimiya K, Ohba T, Seino Y, Mizuno K (2007) Serial long-term evaluation of neointimal stent coverage and thrombus after sirolimus-eluting stent implantation by use of coronary angioscopy. Heart 93:1533–1536CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Kubo T, Imanishi T, Kitabata H, Kuroi A, Ueno S, Yamano T, Tanimoto T, Matsuo Y, Masho T, Takarada S, Tanaka A, Nakamura N, Mizukoshi M, Tomobuchi Y, Akasaka T (2008) Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study. JACC Cardiovasc Imaging 1:475–484CrossRefPubMed Kubo T, Imanishi T, Kitabata H, Kuroi A, Ueno S, Yamano T, Tanimoto T, Matsuo Y, Masho T, Takarada S, Tanaka A, Nakamura N, Mizukoshi M, Tomobuchi Y, Akasaka T (2008) Comparison of vascular response after sirolimus-eluting stent implantation between patients with unstable and stable angina pectoris: a serial optical coherence tomography study. JACC Cardiovasc Imaging 1:475–484CrossRefPubMed
35.
Zurück zum Zitat Byrne RA, Iijima R, Mehilli J, Pinieck S, Bruskina O, Schömig A, Kastrati A (2009) Durability of antirestenotic efficacy in drug-eluting stents with and without permanent polymer. JACC Cardiovasc Interv 2(4):291–299CrossRefPubMed Byrne RA, Iijima R, Mehilli J, Pinieck S, Bruskina O, Schömig A, Kastrati A (2009) Durability of antirestenotic efficacy in drug-eluting stents with and without permanent polymer. JACC Cardiovasc Interv 2(4):291–299CrossRefPubMed
36.
Zurück zum Zitat Nakagawa Y, Kimura T, Morimoto T, Nomura M, Saku K, Haruta S, Muramatsu T, Nobuyoshi M, Kadota K, Fujita H, Tatami R, Shiode N, Nishikawa H, Shibata Y, Miyazaki S, Murata Y, Honda T, Kawasaki T, Doi O, Hiasa Y, Hayashi Y, Matsuzaki M, Mitsudo K, j-Cypher Registry Investigators (2010) Incidence and risk factors of late target lesion revascularization after sirolimuseluting stent implantation (3-year follow-up of the j-Cypher Registry). Am J Cardiol 106:329–336CrossRefPubMed Nakagawa Y, Kimura T, Morimoto T, Nomura M, Saku K, Haruta S, Muramatsu T, Nobuyoshi M, Kadota K, Fujita H, Tatami R, Shiode N, Nishikawa H, Shibata Y, Miyazaki S, Murata Y, Honda T, Kawasaki T, Doi O, Hiasa Y, Hayashi Y, Matsuzaki M, Mitsudo K, j-Cypher Registry Investigators (2010) Incidence and risk factors of late target lesion revascularization after sirolimuseluting stent implantation (3-year follow-up of the j-Cypher Registry). Am J Cardiol 106:329–336CrossRefPubMed
37.
Zurück zum Zitat Onuma Y, Miquel-Hebert K, Serruys PW, SPIRITII Investigators (2013) Five-year long-term clinical follow-up of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery disease: the SPIRIT II trial. EuroIntervention 8:1047–1051CrossRefPubMed Onuma Y, Miquel-Hebert K, Serruys PW, SPIRITII Investigators (2013) Five-year long-term clinical follow-up of the XIENCE V everolimus-eluting coronary stent system in the treatment of patients with de novo coronary artery disease: the SPIRIT II trial. EuroIntervention 8:1047–1051CrossRefPubMed
38.
Zurück zum Zitat Yano H, Horinaka S, Ishikawa M, Ishimitsu T (2016) The efficacy of everolimus-eluting stent implantation in patients with ST-segment elevation myocardial infarction: outcomes of 2-year clinical follow-up. Heart Vessels 31:1609–1615CrossRefPubMed Yano H, Horinaka S, Ishikawa M, Ishimitsu T (2016) The efficacy of everolimus-eluting stent implantation in patients with ST-segment elevation myocardial infarction: outcomes of 2-year clinical follow-up. Heart Vessels 31:1609–1615CrossRefPubMed
39.
Zurück zum Zitat Holmes DR Jr, Kereiakes DJ, Garg S, Serruys PW, Dehmer GJ, Ellis SG, Williams DO, Kimura T, Moliterno DJ (2010) Stent thrombosis. J Am Coll Cardiol 56:1357–1365CrossRefPubMed Holmes DR Jr, Kereiakes DJ, Garg S, Serruys PW, Dehmer GJ, Ellis SG, Williams DO, Kimura T, Moliterno DJ (2010) Stent thrombosis. J Am Coll Cardiol 56:1357–1365CrossRefPubMed
40.
Zurück zum Zitat Ong DS, Jang IK (2015) Causes, assessment, and treatment of stent thrombosis-intravascular imaging insights. Nat Rev Cardiol 12:325–336CrossRefPubMed Ong DS, Jang IK (2015) Causes, assessment, and treatment of stent thrombosis-intravascular imaging insights. Nat Rev Cardiol 12:325–336CrossRefPubMed
41.
Zurück zum Zitat Lagerqvist B, Carlsson J, Fröbert O, Lindbäck J, Scherstén F, Stenestrand U, James SK, Swedish Coronary Angiography and Angioplasty Registry Study Group (2009) Stent thrombosis in Sweden: a report from the Swedish coronary angiography and angioplasty registry. Circ Cardiovasc Interv 2:401–408CrossRefPubMed Lagerqvist B, Carlsson J, Fröbert O, Lindbäck J, Scherstén F, Stenestrand U, James SK, Swedish Coronary Angiography and Angioplasty Registry Study Group (2009) Stent thrombosis in Sweden: a report from the Swedish coronary angiography and angioplasty registry. Circ Cardiovasc Interv 2:401–408CrossRefPubMed
42.
Zurück zum Zitat Steg PG, Fox KA, Eagle KA, Furman M, Van de Werf F, Montalescot G, Goodman SG, Avezum A, Huang W, Gore JM, Global Registry of Acute Coronary Events (GRACE) Investigators (2009) Mortality following placement of drug-eluting and bare-metal stents for ST-segment elevation acute myocardial infarction in the Global Registry of Acute Coronary Events. Eur Heart J 30:321–329CrossRefPubMed Steg PG, Fox KA, Eagle KA, Furman M, Van de Werf F, Montalescot G, Goodman SG, Avezum A, Huang W, Gore JM, Global Registry of Acute Coronary Events (GRACE) Investigators (2009) Mortality following placement of drug-eluting and bare-metal stents for ST-segment elevation acute myocardial infarction in the Global Registry of Acute Coronary Events. Eur Heart J 30:321–329CrossRefPubMed
43.
Zurück zum Zitat Kim BK, Kim JS, Park J, Ko YG, Choi D, Jang Y, Hong MK (2012) Comparison of optical coherence tomographic assessment between first- and second-generation drug-eluting stents. Yonsei Med J 53:524–529CrossRefPubMedPubMedCentral Kim BK, Kim JS, Park J, Ko YG, Choi D, Jang Y, Hong MK (2012) Comparison of optical coherence tomographic assessment between first- and second-generation drug-eluting stents. Yonsei Med J 53:524–529CrossRefPubMedPubMedCentral
44.
Zurück zum Zitat Kolandaivelu K, Swaminathan R, Gibson WJ, Kolachalama VB, Nguyen-Ehrenreich KL, Giddings VL, Coleman L, Wong GK, Edelman ER (2011) Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings. Circulation 123:1400–1409CrossRefPubMedPubMedCentral Kolandaivelu K, Swaminathan R, Gibson WJ, Kolachalama VB, Nguyen-Ehrenreich KL, Giddings VL, Coleman L, Wong GK, Edelman ER (2011) Stent thrombogenicity early in high-risk interventional settings is driven by stent design and deployment and protected by polymer-drug coatings. Circulation 123:1400–1409CrossRefPubMedPubMedCentral
45.
Zurück zum Zitat Kastrati A, Mehilli J, Dirschinger J, Dotzer F, Schühlen H, Neumann FJ, Fleckenstein M, Pfafferott C, Seyfarth M, Schömig A (2001) Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation 103:2816–2821CrossRefPubMed Kastrati A, Mehilli J, Dirschinger J, Dotzer F, Schühlen H, Neumann FJ, Fleckenstein M, Pfafferott C, Seyfarth M, Schömig A (2001) Intracoronary stenting and angiographic results: strut thickness effect on restenosis outcome (ISAR-STEREO) trial. Circulation 103:2816–2821CrossRefPubMed
46.
Zurück zum Zitat Levine GN, Bates ER, Bittl JA, Brindis RG, Fihn SD, Fleisher LA, Granger CB, Lange RA, Mack MJ, Mauri L, Mehran R, Mukherjee D, Newby LK, O'Gara PT, Sabatine MS, Smith PK, Smith SC Jr, Halperin JL, Levine GN, Al-Khatib SM, Birtcher KK, Bozkurt B, Brindis RG, Cigarroa JE, Curtis LH, Fleisher LA, Gentile F, Gidding S, Hlatky MA, Ikonomidis JS, Joglar JA, Pressler SJ, Wijeysundera DN (2016) 2016 ACC/AHA guideline focused update on duration of dual antiplatelet therapy in patients with coronary artery disease: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. J Thorac Cardiovasc Surg 152:1243–1275CrossRefPubMed Levine GN, Bates ER, Bittl JA, Brindis RG, Fihn SD, Fleisher LA, Granger CB, Lange RA, Mack MJ, Mauri L, Mehran R, Mukherjee D, Newby LK, O'Gara PT, Sabatine MS, Smith PK, Smith SC Jr, Halperin JL, Levine GN, Al-Khatib SM, Birtcher KK, Bozkurt B, Brindis RG, Cigarroa JE, Curtis LH, Fleisher LA, Gentile F, Gidding S, Hlatky MA, Ikonomidis JS, Joglar JA, Pressler SJ, Wijeysundera DN (2016) 2016 ACC/AHA guideline focused update on duration of dual antiplatelet therapy in patients with coronary artery disease: a report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. J Thorac Cardiovasc Surg 152:1243–1275CrossRefPubMed
47.
Zurück zum Zitat Otsuki S, Brugaletta S, Sabaté M, Shiratori Y, Gomez-Monterrosas O, Scalone G, Romero-Villafañe S, Hernández-Enríquez M, Freixa X, Martín-Yuste V, Masotti M (2016) Overtime evaluation of the vascular HEALing process after everolimus-eluting stent implantation by optical coherence tomography. The HEAL-EES study. Cardiovasc Revasc Med 17:241–247CrossRefPubMed Otsuki S, Brugaletta S, Sabaté M, Shiratori Y, Gomez-Monterrosas O, Scalone G, Romero-Villafañe S, Hernández-Enríquez M, Freixa X, Martín-Yuste V, Masotti M (2016) Overtime evaluation of the vascular HEALing process after everolimus-eluting stent implantation by optical coherence tomography. The HEAL-EES study. Cardiovasc Revasc Med 17:241–247CrossRefPubMed
48.
Zurück zum Zitat Kimura T, Morimoto T, Natsuaki M, Shiomi H, Igarashi K, Kadota K, Tanabe K, Morino Y, Akasaka T, Takatsu Y, Nishikawa H, Yamamoto Y, Nakagawa Y, Hayashi Y, Iwabuchi M, Umeda H, Kawai K, Okada H, Kimura K, Simonton CA, Kozuma K, RESET Investigators (2012) Comparison of everolimus-eluting and sirolimus-eluting coronary stents: 1-year outcomes from the Randomized Evaluation of Sirolimus-eluting Versus Everolimuseluting stent Trial (RESET). Circulation 126:1225–1236CrossRefPubMed Kimura T, Morimoto T, Natsuaki M, Shiomi H, Igarashi K, Kadota K, Tanabe K, Morino Y, Akasaka T, Takatsu Y, Nishikawa H, Yamamoto Y, Nakagawa Y, Hayashi Y, Iwabuchi M, Umeda H, Kawai K, Okada H, Kimura K, Simonton CA, Kozuma K, RESET Investigators (2012) Comparison of everolimus-eluting and sirolimus-eluting coronary stents: 1-year outcomes from the Randomized Evaluation of Sirolimus-eluting Versus Everolimuseluting stent Trial (RESET). Circulation 126:1225–1236CrossRefPubMed
Metadaten
Titel
Comparison of the vessel healing process after everolimus-eluting stent and bare metal stent implantations in patients with ST-elevation myocardial infarction
verfasst von
Hideki Yano
Shigeo Horinaka
Manami Watahik
Tomoko Watanabe
Toshihiko Ishimitsu
Publikationsdatum
03.11.2018
Verlag
Springer Japan
Erschienen in
Heart and Vessels / Ausgabe 4/2019
Print ISSN: 0910-8327
Elektronische ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-018-1287-1

Weitere Artikel der Ausgabe 4/2019

Heart and Vessels 4/2019 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.