Skip to main content
Erschienen in: International Orthopaedics 9/2017

10.04.2017 | Original Paper

Comparison of traditional surgery and surgery assisted by three dimensional printing technology in the treatment of tibial plateau fractures

verfasst von: Yiting Lou, Leyi Cai, Chenggui Wang, Qian Tang, Tianlong Pan, Xiaoshan Guo, Jianshun Wang

Erschienen in: International Orthopaedics | Ausgabe 9/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

This study was conducted to compare traditional surgery and surgery assisted by 3D printing technology in the treatment of tibial plateau fractures. In addition, we also investigated the effect of 3D printing technology on the communication between doctors and patients.

Methods

Seventy two patients with tibial plateau fractures were enrolled in the study from April 2014 to October 2015. They were divided into two groups: 34 cases of 3D model group, 38 cases of traditional surgery group. The individual models were used to simulate the surgical procedures and carry out the surgery according to plan. Operation time, blood loss, and number of intra-operative fluoroscopy were recorded. Through the follow-up, the recovery of patients were observed. Besides, we designed questionnaires to verify the satisfaction for both surgeons and patients.

Results

The average operation time, average amount of blood loss, and number of intra-operative fluoroscopy for 3D model group was 85.2±0.9 minutes, 186.3± 5.5ml, 5.3± 0.2 times, and for traditional surgery group was 99.2±1.0 minutes, 216.2 ±6.9 ml,7.1 ± 0.2 times respectively. There was statistically significant difference between the traditional surgery group and 3D model group (P < 0.05). Via follow-up, we can see that the 3D printing group has a better clinical efficacy. The average score of the questionnaires to Patient and doctors were 7.3 ± 0.1 points and 8.5± 0.1 points respectively.

Conclusion

This study suggested the clinical feasibility of 3D printing technology in treatment of tibial plateau fractures.
Literatur
4.
Zurück zum Zitat Ali AM, Elshafie M, Willett KM (2002) Failure of fixation of tibial plateau fractures. J Orthop Trauma 16(5):323–329CrossRefPubMed Ali AM, Elshafie M, Willett KM (2002) Failure of fixation of tibial plateau fractures. J Orthop Trauma 16(5):323–329CrossRefPubMed
5.
Zurück zum Zitat Barei DP, Nork SE, Mills WJ, Henley MB, Benirschke SK (2004) Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique. J Orthop Trauma 18(10):649–657CrossRefPubMed Barei DP, Nork SE, Mills WJ, Henley MB, Benirschke SK (2004) Complications associated with internal fixation of high-energy bicondylar tibial plateau fractures utilizing a two-incision technique. J Orthop Trauma 18(10):649–657CrossRefPubMed
7.
Zurück zum Zitat Yang L, Shang XW, Fan JN et al (2016) Application of 3D printing in the surgical planning of trimalleolar fracture and doctor-patient communication. Biomed Res Int 2016(420):1–5 Yang L, Shang XW, Fan JN et al (2016) Application of 3D printing in the surgical planning of trimalleolar fracture and doctor-patient communication. Biomed Res Int 2016(420):1–5
8.
Zurück zum Zitat Chung KJ, Huang B, Choi CH et al (2015) Utility of 3D printing for complex distal tibial fractures and malleolar avulsion fractures: technical tip. Foot Ankle Int 36(12):1504CrossRefPubMed Chung KJ, Huang B, Choi CH et al (2015) Utility of 3D printing for complex distal tibial fractures and malleolar avulsion fractures: technical tip. Foot Ankle Int 36(12):1504CrossRefPubMed
9.
10.
Zurück zum Zitat Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80(3):814–820. doi:10.1016/j.ejrad.2010.10.007 CrossRefPubMed Bagaria V, Deshpande S, Rasalkar DD, Kuthe A, Paunipagar BK (2011) Use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. use of rapid prototyping and three-dimensional reconstruction modeling in the management of complex fractures. Eur J Radiol 80(3):814–820. doi:10.​1016/​j.​ejrad.​2010.​10.​007 CrossRefPubMed
11.
Zurück zum Zitat Mellema JJ, Doornberg JN, Molenaars RJ et al (2016) Tibial plateau fracture characteristics: reliability and diagnostic accuracy. J Orthop Trauma 30(5):e144CrossRefPubMed Mellema JJ, Doornberg JN, Molenaars RJ et al (2016) Tibial plateau fracture characteristics: reliability and diagnostic accuracy. J Orthop Trauma 30(5):e144CrossRefPubMed
13.
Zurück zum Zitat Carrera I, Gelber P E, Chary G, et al. (2016) Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration. Int Orthopaed: 1-–7 Carrera I, Gelber P E, Chary G, et al. (2016) Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration. Int Orthopaed: 1-–7
14.
Zurück zum Zitat Wang L, Yu S, Lin CS et al (2016) The application of a three-column internal fixation system with anatomical locking plates on comminuted fractures of the tibial plateau. Int Orthop 40(7):1509–1514CrossRefPubMed Wang L, Yu S, Lin CS et al (2016) The application of a three-column internal fixation system with anatomical locking plates on comminuted fractures of the tibial plateau. Int Orthop 40(7):1509–1514CrossRefPubMed
15.
Zurück zum Zitat Ehlinger M, Adamczewski B, Adam P, et al. (2015) Comparison of the pre-shaped anatomical locking plate of 3.5 mm versus 4.5 mm for the treatment of tibial plateau fractures. Int Orthopaed: 1–7 Ehlinger M, Adamczewski B, Adam P, et al. (2015) Comparison of the pre-shaped anatomical locking plate of 3.5 mm versus 4.5 mm for the treatment of tibial plateau fractures. Int Orthopaed: 1–7
16.
Zurück zum Zitat Benum P, Aamodt AL (2010) Customised femoral stems in osteopetrosis and the development of a guiding system for the preparation of an intramedullary cavity: a report of two cases. Bone Joint J 92(9):1303–1305. doi:10.1302/0301-620X.92B9 CrossRef Benum P, Aamodt AL (2010) Customised femoral stems in osteopetrosis and the development of a guiding system for the preparation of an intramedullary cavity: a report of two cases. Bone Joint J 92(9):1303–1305. doi:10.​1302/​0301-620X.​92B9 CrossRef
19.
Zurück zum Zitat Cockburn J, Walters WA (1999) Communication between doctors and patients. Curr Obstet Gynaecol 9(1):34–40CrossRef Cockburn J, Walters WA (1999) Communication between doctors and patients. Curr Obstet Gynaecol 9(1):34–40CrossRef
Metadaten
Titel
Comparison of traditional surgery and surgery assisted by three dimensional printing technology in the treatment of tibial plateau fractures
verfasst von
Yiting Lou
Leyi Cai
Chenggui Wang
Qian Tang
Tianlong Pan
Xiaoshan Guo
Jianshun Wang
Publikationsdatum
10.04.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 9/2017
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-017-3445-y

Weitere Artikel der Ausgabe 9/2017

International Orthopaedics 9/2017 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.