Skip to main content
main-content

01.11.2010 | Original Article | Ausgabe 11/2010

European Journal of Nuclear Medicine and Molecular Imaging 11/2010

Comparison of two neural network classifiers in the differential diagnosis of essential tremor and Parkinson’s disease by 123I-FP-CIT brain SPECT

Zeitschrift:
European Journal of Nuclear Medicine and Molecular Imaging > Ausgabe 11/2010
Autoren:
Barbara Palumbo, Mario Luca Fravolini, Susanna Nuvoli, Angela Spanu, Kai Stephan Paulus, Orazio Schillaci, Giuseppe Madeddu
Wichtige Hinweise
An erratum to this article can be found at http://​dx.​doi.​org/​10.​1007/​s00259-010-1547-5

Abstract

Purpose

To contribute to the differentiation of Parkinson’s disease (PD) and essential tremor (ET), we compared two different artificial neural network classifiers using 123I-FP-CIT SPECT data, a probabilistic neural network (PNN) and a classification tree (ClT).

Methods

123I-FP-CIT brain SPECT with semiquantitative analysis was performed in 216 patients: 89 with ET, 64 with PD with a Hoehn and Yahr (H&Y) score of ≤2 (early PD), and 63 with PD with a H&Y score of ≥2.5 (advanced PD). For each of the 1,000 experiments carried out, 108 patients were randomly selected as the PNN training set, while the remaining 108 validated the trained PNN, and the percentage of the validation data correctly classified in the three groups of patients was computed. The expected performance of an “average performance PNN” was evaluated. In analogy, for ClT 1,000 classification trees with similar structures were generated.

Results

For PNN, the probability of correct classification in patients with early PD was 81.9±8.1% (mean±SD), in patients with advanced PD 78.9±8.1%, and in ET patients 96.6±2.6%. For ClT, the first decision rule gave a mean value for the putamen of 5.99, which resulted in a probability of correct classification of 93.5±3.4%. This means that patients with putamen values >5.99 were classified as having ET, while patients with putamen values <5.99 were classified as having PD. Furthermore, if the caudate nucleus value was higher than 6.97 patients were classified as having early PD (probability 69.8±5.3%), and if the value was <6.97 patients were classified as having advanced PD (probability 88.1%±8.8%).

Conclusion

These results confirm that PNN achieved valid classification results. Furthermore, ClT provided reliable cut-off values able to differentiate ET and PD of different severities.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 11/2010

European Journal of Nuclear Medicine and Molecular Imaging 11/2010 Zur Ausgabe
  1. Sie können e.Med Radiologie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  2. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.