Skip to main content
Erschienen in: Nuclear Medicine and Molecular Imaging 3/2020

01.06.2020 | Original Article

Computed Tomography (CT) Protocols Associated with Cardiac and Bone Single-Photon Emission Computed Tomography/CT (SPECT/CT) in Korea

verfasst von: Eun Jeong Lee, Ji Young Kim, Jung Mi Park, Bong-Il Song, Hongyoon Choi, Hye-kyeong Shim, Hey Lim Park, Ho-Young Lee, Kyung Jae Lee, Joon-Kee Yoon, Seongho Seo, Seong Min Kim, Soo Bin Park, Young Seok Cho, Seong Hoon Kim

Erschienen in: Nuclear Medicine and Molecular Imaging | Ausgabe 3/2020

Einloggen, um Zugang zu erhalten

Abstract

Purpose

Single-photon emission computed tomography/computed tomography (SPECT/CT) is an advanced hybrid nuclear medicine technology that generates both functional and anatomical images in a single study. As utilization of SPECT/CT in Korea has been increasing, the purpose of this study was to survey its application of cardiac and skeletal SPECT/CT imaging for protocol optimization.

Methods

We surveyed CT protocols established for cardiac and skeletal SPECT/CT. We searched the guidelines for the CT protocols for SPECT/CT and reviewed the literature recently published.

Results

Among 36 hybrid SPECT scanners equipped with four or more multi-channel detector CTs (MDCTs), 18 scanners were used to perform cardiac studies at both very low current CT (30–80 mA; 11.1%) and ultra-low current CT (13–30 mA; 88.9%). Among the 33 canners, very low current (≤ 80 mA) CT or low current CT (80–130 mA) was used in 23.5%, and 41.8% for spine disorders, and in 36.4% or 30.3% for foot/ankle disorders, respectively. In the CT reconstructions, slice thickness of 5 mm for cardiac studies was most commonly used (94.4%); thinner slices (0.6–1.0 mm) for spine and foot/ankle studies were used in 24.2% and 45.5%, respectively. We also reviewed the international guidelines.

Conclusions

The results and current recommendations will be helpful for optimizing CT protocols for SPECT/CT. Optimization of SPECT/CT protocols will be required for generating the proper strategy for the specific lesions and clinical purpose.
Literatur
1.
Zurück zum Zitat Delbeke D, Coleman RE, Guiberteau MJ, Brown ML, Royal HD, Siegel BA, et al. Procedure guideline for SPECT/CT imaging 1.0. J Nucl Med. 2006;47:1227–34.PubMed Delbeke D, Coleman RE, Guiberteau MJ, Brown ML, Royal HD, Siegel BA, et al. Procedure guideline for SPECT/CT imaging 1.0. J Nucl Med. 2006;47:1227–34.PubMed
2.
Zurück zum Zitat Clinical applications of SPECT/CT: new hybrid nuclear medicine imaging system. IAEA-TECDOC-1597. 2008. Clinical applications of SPECT/CT: new hybrid nuclear medicine imaging system. IAEA-TECDOC-1597. 2008.
3.
Zurück zum Zitat Van den Wyngaert T, Strobel K, Kampen WU, Kuwert T, van der Bruggen W, Mohan HK, et al. The EANM practice guidelines for bone scintigraphy. Eur J Nucl Med Mol Imaging. 2016;43:1723–38.PubMedPubMedCentralCrossRef Van den Wyngaert T, Strobel K, Kampen WU, Kuwert T, van der Bruggen W, Mohan HK, et al. The EANM practice guidelines for bone scintigraphy. Eur J Nucl Med Mol Imaging. 2016;43:1723–38.PubMedPubMedCentralCrossRef
4.
Zurück zum Zitat Dalrymple NC, Prasad SR, El-Merhi FM, Chintapalli KN. Price of isotropy in multi-detector CT. Radiographics. 2007;27:49–62.PubMedCrossRef Dalrymple NC, Prasad SR, El-Merhi FM, Chintapalli KN. Price of isotropy in multi-detector CT. Radiographics. 2007;27:49–62.PubMedCrossRef
5.
Zurück zum Zitat The Korean Society of Radiology and Health Insurance Review and Assessment Service. CT Examination and Repeat CT Examination Guidelines. 2013 (Korean) http://www.hira.or.kr/title of subordinate document. Accessed 20. April 2020. The Korean Society of Radiology and Health Insurance Review and Assessment Service. CT Examination and Repeat CT Examination Guidelines. 2013 (Korean) http://​www.​hira.​or.​kr/​title of subordinate document. Accessed 20. April 2020.
6.
Zurück zum Zitat The Korean Society of Radiology and Health Insurance Review and Assessment Service. CT Examination Guidelines for Justification and Optimization. 2012 (Korean) http://nifds.go.kr/brd/title of subordinate document. Accessed 20. April 2020. The Korean Society of Radiology and Health Insurance Review and Assessment Service. CT Examination Guidelines for Justification and Optimization. 2012 (Korean) http://​nifds.​go.​kr/​brd/​title of subordinate document. Accessed 20. April 2020.
7.
Zurück zum Zitat Gupta SK, Trethewey S, Brooker B, Rutherford N, Diffey J, Viswanathan S, et al. Radionuclide bone scan SPECT-CT: lowering the dose of CT significantly reduces radiation dose without impacting CT image quality. Am J Nucl Med Mol Imaging. 2017;7:63–73.PubMedPubMedCentral Gupta SK, Trethewey S, Brooker B, Rutherford N, Diffey J, Viswanathan S, et al. Radionuclide bone scan SPECT-CT: lowering the dose of CT significantly reduces radiation dose without impacting CT image quality. Am J Nucl Med Mol Imaging. 2017;7:63–73.PubMedPubMedCentral
8.
Zurück zum Zitat Huang K, Feng Y, Liu D, Liang W, Li L. Quantification evaluation of 99mTc-MDP concentration in the lumbar spine with SPECT/CT: compare with bone mineral density. Ann Nucl Med. 2020;34:136–43.PubMedCrossRef Huang K, Feng Y, Liu D, Liang W, Li L. Quantification evaluation of 99mTc-MDP concentration in the lumbar spine with SPECT/CT: compare with bone mineral density. Ann Nucl Med. 2020;34:136–43.PubMedCrossRef
9.
Zurück zum Zitat Gaddikeri S, Matesan M, Alvarez J, Hippe DS, Vesselle HJ. MDP-SPECT versus hybrid MDP-SPECT/CT in the evaluation of suspected pars interarticularis fracture in young athletes. J Neuroimaging. 2018;28:635–9.PubMedCrossRef Gaddikeri S, Matesan M, Alvarez J, Hippe DS, Vesselle HJ. MDP-SPECT versus hybrid MDP-SPECT/CT in the evaluation of suspected pars interarticularis fracture in young athletes. J Neuroimaging. 2018;28:635–9.PubMedCrossRef
10.
Zurück zum Zitat Tamm AS, Abele JT. Bone and gallium single-photon emission computed tomography-computed tomography is equivalent to magnetic resonance imaging in the diagnosis of infectious spondylodiscitis: a retrospective study. Can Assoc Radiol J. 2017;68:41–6.PubMedCrossRef Tamm AS, Abele JT. Bone and gallium single-photon emission computed tomography-computed tomography is equivalent to magnetic resonance imaging in the diagnosis of infectious spondylodiscitis: a retrospective study. Can Assoc Radiol J. 2017;68:41–6.PubMedCrossRef
11.
Zurück zum Zitat Russo VM, Dhawan RT, Dharmarajah N, Baudracco I, Lazzarino AI, Casey AT. Hybrid bone single photon emission computed tomography imaging in evaluation of chronic low back pain: correlation with modic changes and degenerative disc disease. World Neurosurg. 2017;104:816–23.PubMedCrossRef Russo VM, Dhawan RT, Dharmarajah N, Baudracco I, Lazzarino AI, Casey AT. Hybrid bone single photon emission computed tomography imaging in evaluation of chronic low back pain: correlation with modic changes and degenerative disc disease. World Neurosurg. 2017;104:816–23.PubMedCrossRef
12.
Zurück zum Zitat Russo VM, Dhawan RT, Baudracco I, Dharmarajah N, Lazzarino AI, Casey AT. Hybrid bone SPECT/CT imaging in evaluation of chronic low back pain: correlation with facet joint arthropathy. World Neurosurg. 2017;107:732–8.PubMedCrossRef Russo VM, Dhawan RT, Baudracco I, Dharmarajah N, Lazzarino AI, Casey AT. Hybrid bone SPECT/CT imaging in evaluation of chronic low back pain: correlation with facet joint arthropathy. World Neurosurg. 2017;107:732–8.PubMedCrossRef
13.
Zurück zum Zitat Russo VM, Duits A, Dhawan RT, Casey AT. Joint arthropathy at the cranio-vertebral junction. scintigraphic patterns on bone SPECT/CT. Br J Neurosurg. 2017;31:45–9.PubMedCrossRef Russo VM, Duits A, Dhawan RT, Casey AT. Joint arthropathy at the cranio-vertebral junction. scintigraphic patterns on bone SPECT/CT. Br J Neurosurg. 2017;31:45–9.PubMedCrossRef
14.
Zurück zum Zitat Van de Kelft E, Verleye G, Van de Kelft AS, Melis K, Van Goethem J. Validation of topographic hybrid single-photon emission computerized tomography with computerized tomography scan in patients with and without nonspecific chronic low back pain. A prospective comparative study. Spine J. 2017;17:1457–63.PubMedCrossRef Van de Kelft E, Verleye G, Van de Kelft AS, Melis K, Van Goethem J. Validation of topographic hybrid single-photon emission computerized tomography with computerized tomography scan in patients with and without nonspecific chronic low back pain. A prospective comparative study. Spine J. 2017;17:1457–63.PubMedCrossRef
15.
Zurück zum Zitat Kato S, Demura S, Matsubara H, Inaki A, Shinmura K, Yokogawa N, et al. Utility of bone SPECT/CT to identify the primary cause of pain in elderly patients with degenerative lumbar spine disease. Orthop Surg Res. 2019;20:185.CrossRef Kato S, Demura S, Matsubara H, Inaki A, Shinmura K, Yokogawa N, et al. Utility of bone SPECT/CT to identify the primary cause of pain in elderly patients with degenerative lumbar spine disease. Orthop Surg Res. 2019;20:185.CrossRef
16.
Zurück zum Zitat Gnanasegaran G, Paycha F, Strobel K, van der Bruggen W, Kampen WU, Kuwert T, et al. Bone SPECT/CT in postoperative spine. Semin Nucl Med. 2018;48:410–24.PubMedCrossRef Gnanasegaran G, Paycha F, Strobel K, van der Bruggen W, Kampen WU, Kuwert T, et al. Bone SPECT/CT in postoperative spine. Semin Nucl Med. 2018;48:410–24.PubMedCrossRef
17.
Zurück zum Zitat Al-Riyami K, Vöö S, Gnanasegaran G, Pressney I, Meir A, Casey A, et al. The role of bone SPECT/CT in patients with persistent or recurrent lumbar pain following lumbar spine stabilization surgery. Eur J Nucl Med Mol Imaging. 2019;46:989–98.PubMedCrossRef Al-Riyami K, Vöö S, Gnanasegaran G, Pressney I, Meir A, Casey A, et al. The role of bone SPECT/CT in patients with persistent or recurrent lumbar pain following lumbar spine stabilization surgery. Eur J Nucl Med Mol Imaging. 2019;46:989–98.PubMedCrossRef
18.
Zurück zum Zitat Zhang L, He Q, Jiang M, Zhang B, Zhong X, Zhang R. Diagnosis of insufficiency fracture after radiotherapy in patients with cervical cancer: contribution of technetium Tc 99m-labeled methylene diphosphonate single-photon emission computed tomography/computed tomography. Int J Gynecol Cancer. 2018;28:1369–76.PubMedCrossRef Zhang L, He Q, Jiang M, Zhang B, Zhong X, Zhang R. Diagnosis of insufficiency fracture after radiotherapy in patients with cervical cancer: contribution of technetium Tc 99m-labeled methylene diphosphonate single-photon emission computed tomography/computed tomography. Int J Gynecol Cancer. 2018;28:1369–76.PubMedCrossRef
19.
20.
Zurück zum Zitat Bhure U, Roos JE, Pérez Lago MDS, Steurer I, Grünig H, Hug U, et al. SPECT/CT arthrography. Br J Radiol. 2018;91:1082. Bhure U, Roos JE, Pérez Lago MDS, Steurer I, Grünig H, Hug U, et al. SPECT/CT arthrography. Br J Radiol. 2018;91:1082.
21.
Zurück zum Zitat Bhure U, Roos JE, Perez-Lago MDS, Strobel K. Single-photon emission computed tomography/computed tomography arthrography of wrist, ankle, and knee joints. Nucl Med Commun. 2020;41:182–8.PubMedCrossRef Bhure U, Roos JE, Perez-Lago MDS, Strobel K. Single-photon emission computed tomography/computed tomography arthrography of wrist, ankle, and knee joints. Nucl Med Commun. 2020;41:182–8.PubMedCrossRef
22.
Zurück zum Zitat Bae S, Kang Y, Song YS, Lee WW. Maximum standardized uptake value of foot SPECT/CT using Tc-99m HDP in patients with accessory navicular bone as a predictor of surgical treatment. Medicine (Baltimore). 2019;98:e14022.CrossRef Bae S, Kang Y, Song YS, Lee WW. Maximum standardized uptake value of foot SPECT/CT using Tc-99m HDP in patients with accessory navicular bone as a predictor of surgical treatment. Medicine (Baltimore). 2019;98:e14022.CrossRef
23.
Zurück zum Zitat Kampen WU, Westphal F, Van den Wyngaert T, Strobel K, Kuwert T, Van der Bruggen W. SPECT/CT in postoperative foot and ankle pain. Semin Nucl Med. 2018;48:454–68.PubMedCrossRef Kampen WU, Westphal F, Van den Wyngaert T, Strobel K, Kuwert T, Van der Bruggen W. SPECT/CT in postoperative foot and ankle pain. Semin Nucl Med. 2018;48:454–68.PubMedCrossRef
24.
Zurück zum Zitat Alvelo JL, Papademetris X, Mena-Hurtado C, Jeon S, Sumpio BE, Sinusas AJ, et al. Radiotracer imaging allows for noninvasive detection and quantification of abnormalities in angiosome foot perfusion in diabetic patients with critical limb ischemia and nonhealing wounds. Circ Cardiovasc Imaging. 2018;11:e006932.PubMedPubMedCentralCrossRef Alvelo JL, Papademetris X, Mena-Hurtado C, Jeon S, Sumpio BE, Sinusas AJ, et al. Radiotracer imaging allows for noninvasive detection and quantification of abnormalities in angiosome foot perfusion in diabetic patients with critical limb ischemia and nonhealing wounds. Circ Cardiovasc Imaging. 2018;11:e006932.PubMedPubMedCentralCrossRef
25.
Zurück zum Zitat Chou TH, Atway SA, Bobbey AJ, Sarac TP, Go MR, Stacy MR. SPECT/CT imaging: a noninvasive approach for evaluating serial changes in angiosome foot perfusion in critical limb ischemia. Adv Wound Care (New Rochelle). 2020;9:103–10.CrossRef Chou TH, Atway SA, Bobbey AJ, Sarac TP, Go MR, Stacy MR. SPECT/CT imaging: a noninvasive approach for evaluating serial changes in angiosome foot perfusion in critical limb ischemia. Adv Wound Care (New Rochelle). 2020;9:103–10.CrossRef
27.
Zurück zum Zitat Lu SJ, Ul Hassan F, Vijayanathan S, Gnanasegaran G. Radionuclide bone SPECT/CT in the evaluation of knee pain: comparing two-phase bone scintigraphy. SPECT and SPECT/CT Br J Radiol. 2018;91:20180168.PubMedCrossRef Lu SJ, Ul Hassan F, Vijayanathan S, Gnanasegaran G. Radionuclide bone SPECT/CT in the evaluation of knee pain: comparing two-phase bone scintigraphy. SPECT and SPECT/CT Br J Radiol. 2018;91:20180168.PubMedCrossRef
28.
Zurück zum Zitat Mandegaran R, Agrawal K, Vijayanathan S, Gnanasegaran G. The value of 99mTc-MDP bone SPECT/CT in evaluation of patients with painful knee prosthesis. Nucl Med Commun. 2018;39:397–404.PubMedCrossRef Mandegaran R, Agrawal K, Vijayanathan S, Gnanasegaran G. The value of 99mTc-MDP bone SPECT/CT in evaluation of patients with painful knee prosthesis. Nucl Med Commun. 2018;39:397–404.PubMedCrossRef
29.
Zurück zum Zitat Verschueren J, Albert A, Carp L, Ceyssens S, Huyghe I, Stroobants, et al. Bloodpool SPECT as part of bone SPECT/CT in painful total knee arthroplasty (TKA): validation and potential biomarker of prosthesis biomechanics. Eur J Nucl Med Mol Imaging. 2019;46:1009–18.PubMedCrossRef Verschueren J, Albert A, Carp L, Ceyssens S, Huyghe I, Stroobants, et al. Bloodpool SPECT as part of bone SPECT/CT in painful total knee arthroplasty (TKA): validation and potential biomarker of prosthesis biomechanics. Eur J Nucl Med Mol Imaging. 2019;46:1009–18.PubMedCrossRef
30.
Zurück zum Zitat Kim J, Lee HH, Kang Y, Kim TK, Lee SW, So Y, et al. Maximum standardised uptake value of quantitative bone SPECT/CT in patients with medial compartment osteoarthritis of the knee. Clin Radiol. 2017;72:580–9.PubMedCrossRef Kim J, Lee HH, Kang Y, Kim TK, Lee SW, So Y, et al. Maximum standardised uptake value of quantitative bone SPECT/CT in patients with medial compartment osteoarthritis of the knee. Clin Radiol. 2017;72:580–9.PubMedCrossRef
31.
Zurück zum Zitat De Laroche R, Simon E, Suignard N, Williams T, Henry MP, Robin P, et al. Clinical interest of quantitative bone SPECT-CT in the preoperative assessment of knee osteoarthritis. Medicine (Baltimore). 2018;97:e11943.CrossRef De Laroche R, Simon E, Suignard N, Williams T, Henry MP, Robin P, et al. Clinical interest of quantitative bone SPECT-CT in the preoperative assessment of knee osteoarthritis. Medicine (Baltimore). 2018;97:e11943.CrossRef
32.
Zurück zum Zitat Rechsteiner J, Hirschmann MT, Dordevic M, Falkowski AL, Testa EA, Amsler F, et al. Meniscal pathologies on MRI correlate with increased bone tracer uptake in SPECT/CT. Eur Radiol. 2018;28:4696–704.PubMedCrossRef Rechsteiner J, Hirschmann MT, Dordevic M, Falkowski AL, Testa EA, Amsler F, et al. Meniscal pathologies on MRI correlate with increased bone tracer uptake in SPECT/CT. Eur Radiol. 2018;28:4696–704.PubMedCrossRef
33.
Zurück zum Zitat Egloff C, Huber L, Wurm M, Pagenstert G. No added value using SPECT/CT to analyze persistent symptoms after anterior cruciate ligament reconstruction. Arch Orthop Trauma Surg. 2019;139:807–16.PubMedCrossRef Egloff C, Huber L, Wurm M, Pagenstert G. No added value using SPECT/CT to analyze persistent symptoms after anterior cruciate ligament reconstruction. Arch Orthop Trauma Surg. 2019;139:807–16.PubMedCrossRef
34.
Zurück zum Zitat Van der Bruggen W, Hirschmann MT, Strobel K, Kampen WU, Kuwert T, Gnanasegaran G, et al. SPECT/CT in the postoperative painful knee. Semin Nucl Med. 2018;48:439–53.PubMedCrossRef Van der Bruggen W, Hirschmann MT, Strobel K, Kampen WU, Kuwert T, Gnanasegaran G, et al. SPECT/CT in the postoperative painful knee. Semin Nucl Med. 2018;48:439–53.PubMedCrossRef
35.
Zurück zum Zitat Han YH, Jeong HJ, Sohn MH, Yoon SJ, Lim ST. Incidence and severity of femoral head avascularity after femoral neck or intertrochanteric fractures on preoperative bone single photon emission computed tomography/computed tomography: preliminary study. Nucl Med Commun. 2019;40:199–205.PubMedCrossRef Han YH, Jeong HJ, Sohn MH, Yoon SJ, Lim ST. Incidence and severity of femoral head avascularity after femoral neck or intertrochanteric fractures on preoperative bone single photon emission computed tomography/computed tomography: preliminary study. Nucl Med Commun. 2019;40:199–205.PubMedCrossRef
36.
Zurück zum Zitat Han S, Oh M, Yoon S, Kim J, Kim JW, Chang JS, et al. Risk stratification for avascular necrosis of the femoral head after internal fixation of femoral neck fractures by post-operative bone SPECT/CT. Nucl Med Mol Imaging. 2017;51:49–57.PubMedCrossRef Han S, Oh M, Yoon S, Kim J, Kim JW, Chang JS, et al. Risk stratification for avascular necrosis of the femoral head after internal fixation of femoral neck fractures by post-operative bone SPECT/CT. Nucl Med Mol Imaging. 2017;51:49–57.PubMedCrossRef
37.
Zurück zum Zitat Ryoo HG, Lee WW, Kim JY, Kong E, Choi WH, Yoon JK, et al. Minimum standardized uptake value from quantitative bone single-photon emission computed tomography/computed tomography for evaluation of femoral head viability in patients with femoral neck fracture. Nucl Med Mol Imaging. 2019;53:287–95.PubMedCrossRef Ryoo HG, Lee WW, Kim JY, Kong E, Choi WH, Yoon JK, et al. Minimum standardized uptake value from quantitative bone single-photon emission computed tomography/computed tomography for evaluation of femoral head viability in patients with femoral neck fracture. Nucl Med Mol Imaging. 2019;53:287–95.PubMedCrossRef
38.
Zurück zum Zitat Bäcker HC, Steurer-Dober I, Beck M, Agten CA, Decking J, Herzog RF, et al. Magnetic resonance imaging (MRI) versus single photon emission computed tomography (SPECT/CT) in painful total hip arthroplasty: a comparative multi-institutional analysis. Br J Radiol. 2020;93:20190738.PubMedCrossRef Bäcker HC, Steurer-Dober I, Beck M, Agten CA, Decking J, Herzog RF, et al. Magnetic resonance imaging (MRI) versus single photon emission computed tomography (SPECT/CT) in painful total hip arthroplasty: a comparative multi-institutional analysis. Br J Radiol. 2020;93:20190738.PubMedCrossRef
39.
Zurück zum Zitat Van den Wyngaert T, Paycha F, Strobel K, Kampen WU, Kuwert T, van der Bruggen W, et al. SPECT/CT in postoperative painful hip arthroplasty. Semin Nucl Med. 2018;48:425–38.PubMedCrossRef Van den Wyngaert T, Paycha F, Strobel K, Kampen WU, Kuwert T, van der Bruggen W, et al. SPECT/CT in postoperative painful hip arthroplasty. Semin Nucl Med. 2018;48:425–38.PubMedCrossRef
40.
Zurück zum Zitat Strobel K, van der Bruggen W, Hug U, Gnanasegaran G, Kampen WU, Kuwert T, et al. SPECT/CT in postoperative hand and wrist pain. Semin Nucl Med. 2018;48:396–409.PubMedCrossRef Strobel K, van der Bruggen W, Hug U, Gnanasegaran G, Kampen WU, Kuwert T, et al. SPECT/CT in postoperative hand and wrist pain. Semin Nucl Med. 2018;48:396–409.PubMedCrossRef
41.
Zurück zum Zitat Arıcan P, Okudan B, Şefizade R, Naldöken S. Diagnostic value of bone SPECT/CT in patients with suspected osteomyelitis. Mol Imaging Radionucl Ther. 2019;28:89–95.PubMedPubMedCentralCrossRef Arıcan P, Okudan B, Şefizade R, Naldöken S. Diagnostic value of bone SPECT/CT in patients with suspected osteomyelitis. Mol Imaging Radionucl Ther. 2019;28:89–95.PubMedPubMedCentralCrossRef
42.
Zurück zum Zitat Thélu-Vanysacker M, Frédéric P, Charles-Edouard T, Alban B, Nicolas B, Tanguy B. SPECT/CT in postoperative shoulder pain. Semin Nucl Med. 2018;48:469–82.PubMedCrossRef Thélu-Vanysacker M, Frédéric P, Charles-Edouard T, Alban B, Nicolas B, Tanguy B. SPECT/CT in postoperative shoulder pain. Semin Nucl Med. 2018;48:469–82.PubMedCrossRef
43.
Zurück zum Zitat Lee CH, Goo JM, Ye HJ, Ye SJ, Park CM, Chun EJ, et al. Radiation dose modulation techniques in the multidetector CT era: from basics to practice. Radiographics. 2008;28:1451–9.PubMedCrossRef Lee CH, Goo JM, Ye HJ, Ye SJ, Park CM, Chun EJ, et al. Radiation dose modulation techniques in the multidetector CT era: from basics to practice. Radiographics. 2008;28:1451–9.PubMedCrossRef
44.
Zurück zum Zitat Tsukagoshi S, Ota T, Fujii M, Kazama M, Okumura M, Johkoh T. Improvement of spatial resolution in the longitudinal direction for isotropic image in helical CT. Phys Med Biol. 2007;52:791–801.PubMedCrossRef Tsukagoshi S, Ota T, Fujii M, Kazama M, Okumura M, Johkoh T. Improvement of spatial resolution in the longitudinal direction for isotropic image in helical CT. Phys Med Biol. 2007;52:791–801.PubMedCrossRef
45.
Zurück zum Zitat Rogalla P, Kloeters C, Hein PA. CT technology overview: 64-slice and beyond. Radiol Clin N Am. 2009;47:1–11.PubMedCrossRef Rogalla P, Kloeters C, Hein PA. CT technology overview: 64-slice and beyond. Radiol Clin N Am. 2009;47:1–11.PubMedCrossRef
46.
Zurück zum Zitat Rydberg J, Buckwalter KA, Caldemeyer KS, Phillips MD, Conces DJ, Aisen AM, et al. Multisection CT: scanning techniques and clinical applications. Radiographics. 2000;20:1787–806.PubMedCrossRef Rydberg J, Buckwalter KA, Caldemeyer KS, Phillips MD, Conces DJ, Aisen AM, et al. Multisection CT: scanning techniques and clinical applications. Radiographics. 2000;20:1787–806.PubMedCrossRef
47.
Zurück zum Zitat Johnson PT, Fayad LM, Fishman EK. Sixteen slice CT with volumetric analysis of foot fractures. Emerg Radiol. 2006;12:171–6.PubMedCrossRef Johnson PT, Fayad LM, Fishman EK. Sixteen slice CT with volumetric analysis of foot fractures. Emerg Radiol. 2006;12:171–6.PubMedCrossRef
48.
Zurück zum Zitat Santos DT, Oliveira JX, Vannier MW, Cavalcanti MGP. Computed tomography imaging strategies and perspectives in orbital fractures. J Appl Oral Sci. 2007;15:135–9.PubMedPubMedCentralCrossRef Santos DT, Oliveira JX, Vannier MW, Cavalcanti MGP. Computed tomography imaging strategies and perspectives in orbital fractures. J Appl Oral Sci. 2007;15:135–9.PubMedPubMedCentralCrossRef
49.
Zurück zum Zitat Alshipli M, Kabir NA. Effect of slice thickness on image noise and diagnostic content of single-source-dual energy computed tomography. J Physics: Conf Series. 2017;851012005:1–6. Alshipli M, Kabir NA. Effect of slice thickness on image noise and diagnostic content of single-source-dual energy computed tomography. J Physics: Conf Series. 2017;851012005:1–6.
Metadaten
Titel
Computed Tomography (CT) Protocols Associated with Cardiac and Bone Single-Photon Emission Computed Tomography/CT (SPECT/CT) in Korea
verfasst von
Eun Jeong Lee
Ji Young Kim
Jung Mi Park
Bong-Il Song
Hongyoon Choi
Hye-kyeong Shim
Hey Lim Park
Ho-Young Lee
Kyung Jae Lee
Joon-Kee Yoon
Seongho Seo
Seong Min Kim
Soo Bin Park
Young Seok Cho
Seong Hoon Kim
Publikationsdatum
01.06.2020
Verlag
Springer Singapore
Erschienen in
Nuclear Medicine and Molecular Imaging / Ausgabe 3/2020
Print ISSN: 1869-3474
Elektronische ISSN: 1869-3482
DOI
https://doi.org/10.1007/s13139-020-00644-9

Weitere Artikel der Ausgabe 3/2020

Nuclear Medicine and Molecular Imaging 3/2020 Zur Ausgabe