Several recently introduced ‘new’ techniques in computed tomography—iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT—actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems.
Literatur
1.
Zurück zum Zitat Ambrose J, Hounsfield G (1973) Computerized transverse axial tomography. Br J Radiol 46:148–149CrossRefPubMed Ambrose J, Hounsfield G (1973) Computerized transverse axial tomography. Br J Radiol 46:148–149CrossRefPubMed
2.
Zurück zum Zitat Hounsfield GN (1973) Computerized transverse axial scanning (tomography). Part 1. Description of system. Br J Radiol 46:1016–1022CrossRefPubMed Hounsfield GN (1973) Computerized transverse axial scanning (tomography). Part 1. Description of system. Br J Radiol 46:1016–1022CrossRefPubMed
3.
Zurück zum Zitat Berrington de Gonzalez A, Mahesh M, Kim KP et al (2009) Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169:2071–2077CrossRefPubMed Berrington de Gonzalez A, Mahesh M, Kim KP et al (2009) Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169:2071–2077CrossRefPubMed
4.
Zurück zum Zitat Shepp LA, Logan BF (1974) The Fourier reconstruction of a head section. IEEE Trans Nucl Sci NS21:21–34 Shepp LA, Logan BF (1974) The Fourier reconstruction of a head section. IEEE Trans Nucl Sci NS21:21–34
5.
Zurück zum Zitat Radon J (1917) Über die Bestimmung von Funktionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten. Berichte Sächsische Acadamie der Wissenschaften 69:262 Radon J (1917) Über die Bestimmung von Funktionen durch ihre Integralwerte längs gewisser Mannigfaltigkeiten. Berichte Sächsische Acadamie der Wissenschaften 69:262
6.
Zurück zum Zitat Rockmore AJ, Macovski A (1976) A maximum likelihood approach to emission image reconstruction from projections. IEEE Trans Nucl Sci 23:1428–1432CrossRef Rockmore AJ, Macovski A (1976) A maximum likelihood approach to emission image reconstruction from projections. IEEE Trans Nucl Sci 23:1428–1432CrossRef
7.
Zurück zum Zitat Boas FE, Fleischmann D (2011) Evaluation of two new iterative techniques for reducing metal artifacts in computed tomography. Radiology in press Boas FE, Fleischmann D (2011) Evaluation of two new iterative techniques for reducing metal artifacts in computed tomography. Radiology in press
8.
Zurück zum Zitat Marin D, Nelson RC, Schindera ST et al (2010) Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm–initial clinical experience. Radiology 254:145–153CrossRefPubMed Marin D, Nelson RC, Schindera ST et al (2010) Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm–initial clinical experience. Radiology 254:145–153CrossRefPubMed
9.
Zurück zum Zitat Yadava G, Kulkarni S, Colon ZR, Thibault J, Hsieh J (2010) TU-A-201B-03: Dose reduction and image quality benefits using model based iterative reconstruction (MBIR) technique for computed tomography. AAPM Annual Meeting. AAPM, Philadelphia, p 3372 Yadava G, Kulkarni S, Colon ZR, Thibault J, Hsieh J (2010) TU-A-201B-03: Dose reduction and image quality benefits using model based iterative reconstruction (MBIR) technique for computed tomography. AAPM Annual Meeting. AAPM, Philadelphia, p 3372
10.
Zurück zum Zitat Pontana F, Pagniez J, Flohr T et al (2010) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients. Eur Radiol. doi:10.1007/s00330-010-1990-5 Pontana F, Pagniez J, Flohr T et al (2010) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients. Eur Radiol. doi:10.​1007/​s00330-010-1990-5
11.
Zurück zum Zitat Sagel SS, Weiss ES, Gillard RG et al (1977) Gated computed tomography of the human heart. Invest Radiol 12:563–566CrossRefPubMed Sagel SS, Weiss ES, Gillard RG et al (1977) Gated computed tomography of the human heart. Invest Radiol 12:563–566CrossRefPubMed
12.
Zurück zum Zitat Harell GS, Guthaner DF, Breiman RS et al (1977) Stop-action cardiac computed tomography. Radiology 123:515–517PubMed Harell GS, Guthaner DF, Breiman RS et al (1977) Stop-action cardiac computed tomography. Radiology 123:515–517PubMed
13.
Zurück zum Zitat Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301:500–507CrossRefPubMed Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301:500–507CrossRefPubMed
14.
Zurück zum Zitat Earls JP, Berman EL, Urban BA et al (2008) Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246:742–753CrossRefPubMed Earls JP, Berman EL, Urban BA et al (2008) Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose. Radiology 246:742–753CrossRefPubMed
15.
Zurück zum Zitat Berninger W, Redington R (1980) Multiple purpose high speed tomographic x-ray scanner. Patent No. 4196325A, USA Berninger W, Redington R (1980) Multiple purpose high speed tomographic x-ray scanner. Patent No. 4196325A, USA
16.
Zurück zum Zitat Tang J, Hsieh J, Chen GH (2010) Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies. Med Phys 37:4377–4388CrossRefPubMed Tang J, Hsieh J, Chen GH (2010) Temporal resolution improvement in cardiac CT using PICCS (TRI-PICCS): performance studies. Med Phys 37:4377–4388CrossRefPubMed
17.
Zurück zum Zitat Chen GH, Tang J, Leng S (2008) Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. Med Phys 35:660–663CrossRefPubMed Chen GH, Tang J, Leng S (2008) Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets. Med Phys 35:660–663CrossRefPubMed
18.
Zurück zum Zitat Flohr TG, McCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268CrossRefPubMed Flohr TG, McCollough CH, Bruder H et al (2006) First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 16:256–268CrossRefPubMed
19.
Zurück zum Zitat Franke K, Siemens Aktiengesellschaft (1979) Tomographic apparatus for producing transverse layer images. Patent No. 4150293, USA Franke K, Siemens Aktiengesellschaft (1979) Tomographic apparatus for producing transverse layer images. Patent No. 4150293, USA
20.
Zurück zum Zitat Wang G, Yu H, De Man B (2008) An outlook on x-ray CT research and development. Med Phys 35:1051–1064CrossRefPubMed Wang G, Yu H, De Man B (2008) An outlook on x-ray CT research and development. Med Phys 35:1051–1064CrossRefPubMed
21.
Zurück zum Zitat Ritman EL, Kinsey JH, Robb RA, Gilbert BK, Harris LD, Wood EH (1980) Three-dimensional imaging of heart, lungs, and circulation. Science 210:273–280CrossRefPubMed Ritman EL, Kinsey JH, Robb RA, Gilbert BK, Harris LD, Wood EH (1980) Three-dimensional imaging of heart, lungs, and circulation. Science 210:273–280CrossRefPubMed
22.
Zurück zum Zitat Petersilka M, Bruder H, Krauss B, Stierstorfer K, Flohr TG (2008) Technical principles of dual-source CT. Eur J Radiol 68:362–368CrossRefPubMed Petersilka M, Bruder H, Krauss B, Stierstorfer K, Flohr TG (2008) Technical principles of dual-source CT. Eur J Radiol 68:362–368CrossRefPubMed
23.
Zurück zum Zitat Schardt P, Deuringer J, Freudenberger J et al (2004) New x-ray tube performance in computed tomography by introducing the rotating envelope tube technology. Med Phys 31:2699–2706CrossRefPubMed Schardt P, Deuringer J, Freudenberger J et al (2004) New x-ray tube performance in computed tomography by introducing the rotating envelope tube technology. Med Phys 31:2699–2706CrossRefPubMed
24.
Zurück zum Zitat Coolidge WD, General Electric Company (1917) X-ray apparatus. Patent No. 1215116, USA Coolidge WD, General Electric Company (1917) X-ray apparatus. Patent No. 1215116, USA
25.
Zurück zum Zitat Alvarez RE, Macovski A (1976) Energy-selective reconstructions in X-ray computerized tomography. Phys Med Biol 21:733–744CrossRefPubMed Alvarez RE, Macovski A (1976) Energy-selective reconstructions in X-ray computerized tomography. Phys Med Biol 21:733–744CrossRefPubMed
26.
Zurück zum Zitat Iwanczyk JS, Nygard E, Meirav O et al (2009) Photon counting energy dispersive detector arrays for X-ray imaging. IEEE Trans Nucl Sci 56:535–542CrossRefPubMed Iwanczyk JS, Nygard E, Meirav O et al (2009) Photon counting energy dispersive detector arrays for X-ray imaging. IEEE Trans Nucl Sci 56:535–542CrossRefPubMed
27.
Zurück zum Zitat Marin D, Nelson RC, Samei E et al (2009) Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection–initial clinical experience. Radiology 251:771–779CrossRefPubMed Marin D, Nelson RC, Samei E et al (2009) Hypervascular liver tumors: low tube voltage, high tube current multidetector CT during late hepatic arterial phase for detection–initial clinical experience. Radiology 251:771–779CrossRefPubMed
28.
Zurück zum Zitat Leschka S, Scheffel H, Desbiolles L et al (2007) Image quality and reconstruction intervals of dual-source ct coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol 42:543–549CrossRefPubMed Leschka S, Scheffel H, Desbiolles L et al (2007) Image quality and reconstruction intervals of dual-source ct coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol 42:543–549CrossRefPubMed
29.
Zurück zum Zitat Chandarana H, Godoy MC, Vlahos I et al (2008) Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms–initial observations. Radiology 249:692–700CrossRefPubMed Chandarana H, Godoy MC, Vlahos I et al (2008) Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms–initial observations. Radiology 249:692–700CrossRefPubMed
30.
Zurück zum Zitat Stolzmann P, Frauenfelder T, Pfammatter T et al (2008) Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology 249:682–691CrossRefPubMed Stolzmann P, Frauenfelder T, Pfammatter T et al (2008) Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT. Radiology 249:682–691CrossRefPubMed
31.
Zurück zum Zitat Graser A, Johnson TR, Chandarana H, Macari M (2009) Dual-energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol 19:13–23CrossRefPubMed Graser A, Johnson TR, Chandarana H, Macari M (2009) Dual-energy CT: preliminary observations and potential clinical applications in the abdomen. Eur Radiol 19:13–23CrossRefPubMed
32.
Zurück zum Zitat Nicolaou S, Yong-Hing CJ, Galea-Soler S, Hou DJ, Louis L, Munk P (2010) Dual-energy CT as a potential new diagnostic tool in the management of gout in the acute setting. AJR Am J Roentgenol 194:1072–1078CrossRefPubMed Nicolaou S, Yong-Hing CJ, Galea-Soler S, Hou DJ, Louis L, Munk P (2010) Dual-energy CT as a potential new diagnostic tool in the management of gout in the acute setting. AJR Am J Roentgenol 194:1072–1078CrossRefPubMed
33.
Zurück zum Zitat Tran DN, Straka M, Roos JE, Napel S, Fleischmann D (2009) Dual-energy CT discrimination of iodine and calcium: experimental results and implications for lower extremity CT angiography. Acad Radiol 16:160–171CrossRefPubMed Tran DN, Straka M, Roos JE, Napel S, Fleischmann D (2009) Dual-energy CT discrimination of iodine and calcium: experimental results and implications for lower extremity CT angiography. Acad Radiol 16:160–171CrossRefPubMed
34.
Zurück zum Zitat Macovski A, Herman GT (1981) Principles of reconstruction algorithms. In Newton TH, Potts DG (eds) Radiology of the skull and brain: technical aspects of computed tomography. Mosby, Saint Louis, MO, pp 3877–3903 Macovski A, Herman GT (1981) Principles of reconstruction algorithms. In Newton TH, Potts DG (eds) Radiology of the skull and brain: technical aspects of computed tomography. Mosby, Saint Louis, MO, pp 3877–3903
Metadaten
Titel
Computed tomography—old ideas and new technology
verfasst von
Dominik Fleischmann
F. Edward Boas
Publikationsdatum
01.03.2011
Verlag
Springer-Verlag
Erschienen in
European Radiology / Ausgabe 3/2011
Print ISSN: 0938-7994
Elektronische ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-011-2056-z

Weitere Artikel der Ausgabe 3/2011

European Radiology 3/2011 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.