Skip to main content
Erschienen in: Journal of Digital Imaging 1/2011

01.02.2011

Computer-Aided Detection of Intracranial Aneurysms in MR Angiography

verfasst von: Xiaojiang Yang, Daniel J. Blezek, Lionel T. E. Cheng, William J. Ryan, David F. Kallmes, Bradley J. Erickson

Erschienen in: Journal of Imaging Informatics in Medicine | Ausgabe 1/2011

Einloggen, um Zugang zu erhalten

Abstract

Intracranial aneurysms represent a significant cause of morbidity and mortality. While the risk factors for aneurysm formation are known, the detection of aneurysms remains challenging. Magnetic resonance angiography (MRA) has recently emerged as a useful non-invasive method for aneurysm detection. However, even for experienced neuroradiologists, the sensitivity to small (<5 mm) aneurysms in MRA images is poor, on the order of 30~60% in recent, large series. We describe a fully automated computer-aided detection (CAD) scheme for detecting aneurysms on 3D time-of-flight (TOF) MRA images. The scheme locates points of interest (POIs) on individual MRA datasets by combining two complementary techniques. The first technique segments the intracranial arteries automatically and finds POIs from the segmented vessels. The second technique identifies POIs directly from the raw, unsegmented image dataset. This latter technique is useful in cases of incomplete segmentation. Following a series of feature calculations, a small fraction of POIs are retained as candidate aneurysms from the collected POIs according to predetermined rules. The CAD scheme was evaluated on 287 datasets containing 147 aneurysms that were verified with digital subtraction angiography, the accepted standard of reference for aneurysm detection. For two different operating points, the CAD scheme achieved a sensitivity of 80% (71% for aneurysms less than 5 mm) with three mean false positives per case, and 95% (91% for aneurysms less than 5 mm) with nine mean false positives per case. In conclusion, the CAD scheme showed good accuracy and may have application in improving the sensitivity of aneurysm detection on MR images.
Literatur
1.
Zurück zum Zitat Kraft JK, Bradey N, Newman PK: Intracranial aneurysm: seen and unseen. J Neurol Neurosurg Psychiatry 74:1431–1431, 2003CrossRefPubMed Kraft JK, Bradey N, Newman PK: Intracranial aneurysm: seen and unseen. J Neurol Neurosurg Psychiatry 74:1431–1431, 2003CrossRefPubMed
2.
Zurück zum Zitat Wardlaw JM, White PM: The detection and management of unruptured intracranial aneurysms. Brain 123(2):205–221, 2000CrossRefPubMed Wardlaw JM, White PM: The detection and management of unruptured intracranial aneurysms. Brain 123(2):205–221, 2000CrossRefPubMed
3.
Zurück zum Zitat Korogi Y, Takahashi M, Mabuchi N, Nakagawa T, Fujiwara S, Horikawa Y, Miki H, O’Uchi T, Shiga H, Shiokawa Y, Watabe T, Furuse M: Intracranial aneurysms: diagnostic accuracy of MR angiography with evaluation of maximum intensity projection and source images. Radiology 199:199–207, 1996PubMed Korogi Y, Takahashi M, Mabuchi N, Nakagawa T, Fujiwara S, Horikawa Y, Miki H, O’Uchi T, Shiga H, Shiokawa Y, Watabe T, Furuse M: Intracranial aneurysms: diagnostic accuracy of MR angiography with evaluation of maximum intensity projection and source images. Radiology 199:199–207, 1996PubMed
4.
Zurück zum Zitat White PM, Teasdale EM, Wardlaw JM, Easton V: Intracranial aneurysms: CT angiography and MR angiography for detection prospective blinded comparison in a large patient cohort. Radiology 219:739–749, 2001PubMed White PM, Teasdale EM, Wardlaw JM, Easton V: Intracranial aneurysms: CT angiography and MR angiography for detection prospective blinded comparison in a large patient cohort. Radiology 219:739–749, 2001PubMed
5.
Zurück zum Zitat Arimura H, Li Q, Korogi Y, Hirai T, Abe H, Yamashita Y, Katsuragawa S, Ikeda R, Doi K: Automated computerized scheme for detection of unruptured intracranial aneurysms in three dimensional magnetic resonance angiography. Acad Radiol 11:1093–1104, 2004CrossRefPubMed Arimura H, Li Q, Korogi Y, Hirai T, Abe H, Yamashita Y, Katsuragawa S, Ikeda R, Doi K: Automated computerized scheme for detection of unruptured intracranial aneurysms in three dimensional magnetic resonance angiography. Acad Radiol 11:1093–1104, 2004CrossRefPubMed
7.
Zurück zum Zitat Syoji K, Katsuya K, Yutaka H: Computer-aided diagnosis of intracranial aneurysms in MRA images with case-based reasoning. IEICE Trans Inf Syst E89-D:340–350, 2006CrossRef Syoji K, Katsuya K, Yutaka H: Computer-aided diagnosis of intracranial aneurysms in MRA images with case-based reasoning. IEICE Trans Inf Syst E89-D:340–350, 2006CrossRef
8.
Zurück zum Zitat Hirai T, Korogi Y, Arimura H, Katsuragawa S, Kitajima M, Yamura M, Yamashita Y, Doi K: Intracranial aneurysms at MR angiography: effect of computer-aided diagnosis on radiologists’ detection performance. Radiology 237(2):605–610, 2005CrossRefPubMed Hirai T, Korogi Y, Arimura H, Katsuragawa S, Kitajima M, Yamura M, Yamashita Y, Doi K: Intracranial aneurysms at MR angiography: effect of computer-aided diagnosis on radiologists’ detection performance. Radiology 237(2):605–610, 2005CrossRefPubMed
9.
Zurück zum Zitat Ta-Chih L, Rangasami LK, Chong-Nam C: Building skeleton models via 3-D medial surface/axis thinning algorithms. CVGIP: Graph Models Image Process 56:462–478, 1994CrossRef Ta-Chih L, Rangasami LK, Chong-Nam C: Building skeleton models via 3-D medial surface/axis thinning algorithms. CVGIP: Graph Models Image Process 56:462–478, 1994CrossRef
10.
Zurück zum Zitat Zhou Y, Arthur WT: Efficient skeletonization of volumetric objects. IEEE Trans Vis Comput Graph 5(3):196–209, 1999CrossRefPubMed Zhou Y, Arthur WT: Efficient skeletonization of volumetric objects. IEEE Trans Vis Comput Graph 5(3):196–209, 1999CrossRefPubMed
11.
Zurück zum Zitat Li Q, Arimura H, Doi K: Selective enhancement filters for lung nodules intracranial aneurysms, and breast microcalcifications. Int Congr Ser 1268:929–934, 2004CrossRef Li Q, Arimura H, Doi K: Selective enhancement filters for lung nodules intracranial aneurysms, and breast microcalcifications. Int Congr Ser 1268:929–934, 2004CrossRef
12.
Zurück zum Zitat Jan JK: Solid Shape, Cambridge, Massachusetts: MIT Press, 1990 Jan JK: Solid Shape, Cambridge, Massachusetts: MIT Press, 1990
13.
Zurück zum Zitat Alessandro C, Claudio C, Raimondo S: 3D face detection using curvature analysis. Pattern Recogn 39:444–455, 2006CrossRef Alessandro C, Claudio C, Raimondo S: 3D face detection using curvature analysis. Pattern Recogn 39:444–455, 2006CrossRef
Metadaten
Titel
Computer-Aided Detection of Intracranial Aneurysms in MR Angiography
verfasst von
Xiaojiang Yang
Daniel J. Blezek
Lionel T. E. Cheng
William J. Ryan
David F. Kallmes
Bradley J. Erickson
Publikationsdatum
01.02.2011
Verlag
Springer-Verlag
Erschienen in
Journal of Imaging Informatics in Medicine / Ausgabe 1/2011
Print ISSN: 2948-2925
Elektronische ISSN: 2948-2933
DOI
https://doi.org/10.1007/s10278-009-9254-0

Weitere Artikel der Ausgabe 1/2011

Journal of Digital Imaging 1/2011 Zur Ausgabe

Update Radiologie