Erschienen in:
25.04.2022 | Case Reports / Case Series
Congenital adult tracheoesophageal fistula repair with transthoracic ventilation: a case report
Erschienen in:
Canadian Journal of Anesthesia/Journal canadien d'anesthésie
|
Ausgabe 9/2022
Einloggen, um Zugang zu erhalten
Abstract
Purpose
To describe our experience using transthoracic ventilation to facilitate oral endotracheal tube (ETT) exchange after accidental ETT cuff rupture during a case of congenital tracheoesophageal fistula (TEF) repair.
Clinical features
A 53-yr-old male underwent a congenital H-type TEF repair via right-sided thoracotomy with a single-lumen ETT and a bronchial blocker. A large air leak developed after ETT cuff rupture during fistula closure. Transthoracic intubation via tracheotomy was performed to continue ventilation during an oral ETT exchange in the lateral position. No hypoxia or hemodynamic compromise occurred.
Conclusions
Airway device choice for TEF repair must be carefully considered in conjunction with the surgical team. In the present case of accidental ETT cuff rupture, rescue transthoracic ventilation safely facilitated oral ETT exchange.