Abstract

Background

Reconstruction of large acetabular defects remains a substantial challenge in hip arthroplasty. There remains a paucity of data on the long-term results of acetabular trabecular metal augments.

Questions/purposes

The purpose of this study was to assess the survivorship, clinical outcomes, restoration of center of rotation of the hip, and radiological signs of component fixation of trabecular metal augments in the context of reconstruction of acetabular defects.

Methods

Between 2002 and 2005, we performed 56 revision (n = 53) and primary (n = 3) THAs using trabecular metal augments in combination with a trabecular metal acetabular component. Of the 56 patients, 16 (29%) died during followup. Of the 40 surviving patients, 37 (93%) had complete radiological followup, 23 (58%) had complete outcome questionnaire followup, and 17 (42%) provided partial questionnaire responses in the clinic or over the telephone. Median followup was 110 months (range, 88–128 months). During that period, we used these implants when preoperative templating indicated that an augment would be required to achieve acetabular implant stability with restoration of the hip center of rotation. We also chose during surgery to use an augment when we could not achieve a stable acetabular trial component without one. The combination of trabecular metal augments and trabecular metal shells was used in 18% (53 of 292) of our acetabular revisions during that time. Survivorship, functional outcome (WOMAC and Oxford hip score), health status (SF-12), and osseointegration according to the criteria of Moore and presence of radiolucencies were determined.

Results

Survivorship of the augments at 10 years was 92% (95% confidence interval, 81%–97%). Four patients underwent cup revision, one for infection and three for loosening. The mean WOMAC global score was 79 (SD 17), the mean Oxford hip score 76 (SD 18), the mean physical component SF-12 score was 39 (SD 11), and the mean mental component SF-12 score was 52 (SD 9). The center of rotation was corrected from more than 35 mm above the inter-teardrop line in 48 of 56 patients preoperatively to only five of 46 postoperatively. One patient had radiographic findings suggestive of loosening, but this patient was asymptomatic.

Conclusions

The results of the acetabular trabecular metal augments continue to be encouraging in the medium to long term with low rates of revision or loosening in this complex group of patients. We continue to recommend the use of these augments in the reconstruction of complex acetabular defects.

Level of Evidence

Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Abolghasemian M, Tangsataporn S, Sternheim A, Backstein D, Safir O, Gross AE. Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss: a mid-term review. J Bone Joint Surg Br. 2013;95:166–172.CrossRef Abolghasemian M, Tangsataporn S, Sternheim A, Backstein D, Safir O, Gross AE. Combined trabecular metal acetabular shell and augment for acetabular revision with substantial bone loss: a mid-term review. J Bone Joint Surg Br. 2013;95:166–172.CrossRef
2.
Zurück zum Zitat Antoniades J, Pellegrini VD. Cross-sectional anatomy of the ilium: implications for acetabular component placement in total hip arthroplasty. Clin Orthop Relat Res. 2012;470:3537–3541.PubMedCentralPubMedCrossRef Antoniades J, Pellegrini VD. Cross-sectional anatomy of the ilium: implications for acetabular component placement in total hip arthroplasty. Clin Orthop Relat Res. 2012;470:3537–3541.PubMedCentralPubMedCrossRef
3.
Zurück zum Zitat Banerjee S, Issa K, Kapadia BH, Pivec R, Khanuja HS, Mont MA. Systematic review on outcomes of acetabular revisions with highly-porous metals. Int Orthop. 2014;38:689–702.PubMedCrossRef Banerjee S, Issa K, Kapadia BH, Pivec R, Khanuja HS, Mont MA. Systematic review on outcomes of acetabular revisions with highly-porous metals. Int Orthop. 2014;38:689–702.PubMedCrossRef
4.
Zurück zum Zitat Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840.PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840.PubMed
5.
Zurück zum Zitat Bobyn JD, Poggie RA, Krygier JJ, Lewallen DG, Hanssen AD, Lewis RJ, Unger AS, O’Keefe TJ, Christie MJ, Nasser S, Wood JE, Stulberg SD, Tanzer M. Clinical validation of a structural porous tantalum biomaterial for adult reconstruction. J Bone Joint Surg Am. 2004;86(Suppl 2):123–129.PubMed Bobyn JD, Poggie RA, Krygier JJ, Lewallen DG, Hanssen AD, Lewis RJ, Unger AS, O’Keefe TJ, Christie MJ, Nasser S, Wood JE, Stulberg SD, Tanzer M. Clinical validation of a structural porous tantalum biomaterial for adult reconstruction. J Bone Joint Surg Am. 2004;86(Suppl 2):123–129.PubMed
6.
Zurück zum Zitat Buttaro MA, Comba F, Pusso R, Piccaluga F. Acetabular revision with metal mesh, impaction bone grafting, and a cemented cup. Clin Orthop Relat Res. 2008;466:2482–2490.PubMedCentralPubMedCrossRef Buttaro MA, Comba F, Pusso R, Piccaluga F. Acetabular revision with metal mesh, impaction bone grafting, and a cemented cup. Clin Orthop Relat Res. 2008;466:2482–2490.PubMedCentralPubMedCrossRef
7.
Zurück zum Zitat Chen WM, Engh CA, Hopper RH, McAuley JP. Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency. J Bone Joint Surg Am. 2000;82:197–206.PubMed Chen WM, Engh CA, Hopper RH, McAuley JP. Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency. J Bone Joint Surg Am. 2000;82:197–206.PubMed
8.
Zurück zum Zitat Christie MJ. Clinical applications of trabecular metal. Am J Orthop. 2002;31:219–220.PubMed Christie MJ. Clinical applications of trabecular metal. Am J Orthop. 2002;31:219–220.PubMed
9.
Zurück zum Zitat Dawson J, Fitzpatrick R, Carr A, Murray DW. Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br. 1996;78:185–190.PubMed Dawson J, Fitzpatrick R, Carr A, Murray DW. Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br. 1996;78:185–190.PubMed
10.
Zurück zum Zitat Dearborn JT, Harris WH. High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. Results after a mean of ten years. J Bone Joint Surg Am. 1999;81:469–480.PubMed Dearborn JT, Harris WH. High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. Results after a mean of ten years. J Bone Joint Surg Am. 1999;81:469–480.PubMed
11.
Zurück zum Zitat Dearborn JT, Harris WH. Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study. J Arthroplasty. 2000;15:8–15.PubMedCrossRef Dearborn JT, Harris WH. Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study. J Arthroplasty. 2000;15:8–15.PubMedCrossRef
12.
Zurück zum Zitat Delp SL, Wixson RL, Komattu AV, Kocmond JH. How superior placement of the joint center in hip arthroplasty affects the abductor muscles. Clin Orthop Relat Res. 1996;328:137–146.PubMedCrossRef Delp SL, Wixson RL, Komattu AV, Kocmond JH. How superior placement of the joint center in hip arthroplasty affects the abductor muscles. Clin Orthop Relat Res. 1996;328:137–146.PubMedCrossRef
13.
Zurück zum Zitat Field RE, Cronin MD, Singh PJ. The Oxford hip scores for primary and revision hip replacement. J Bone Joint Surg Br. 2005;87:618–622.PubMedCrossRef Field RE, Cronin MD, Singh PJ. The Oxford hip scores for primary and revision hip replacement. J Bone Joint Surg Br. 2005;87:618–622.PubMedCrossRef
14.
Zurück zum Zitat Garbuz D, Morsi E, Gross AE. Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft. Study with a minimum five-year follow-up. J Bone Joint Surg Am. 1996;78:693–697.PubMed Garbuz D, Morsi E, Gross AE. Revision of the acetabular component of a total hip arthroplasty with a massive structural allograft. Study with a minimum five-year follow-up. J Bone Joint Surg Am. 1996;78:693–697.PubMed
15.
Zurück zum Zitat Gehrke T, Bangert Y, Schwantes B, Gebauer M, Kendoff D. Acetabular revision in THA using tantalum augments combined with impaction bone grafting. Hip Int. 2013;23:359–365.PubMedCrossRef Gehrke T, Bangert Y, Schwantes B, Gebauer M, Kendoff D. Acetabular revision in THA using tantalum augments combined with impaction bone grafting. Hip Int. 2013;23:359–365.PubMedCrossRef
16.
Zurück zum Zitat Gie GA, Linder L, Ling RS, Simon JP, Slooff TJ, Timperley AJ. Impacted cancellous allografts and cement for revision total hip arthroplasty. J Bone Joint Surg Br. 1993;75:14–21.PubMed Gie GA, Linder L, Ling RS, Simon JP, Slooff TJ, Timperley AJ. Impacted cancellous allografts and cement for revision total hip arthroplasty. J Bone Joint Surg Br. 1993;75:14–21.PubMed
17.
Zurück zum Zitat Gross AE. Revision arthroplasty of the acetabulum with restoration of bone stock. Clin Orthop Relat Res. 1999;369:198–207.PubMedCrossRef Gross AE. Revision arthroplasty of the acetabulum with restoration of bone stock. Clin Orthop Relat Res. 1999;369:198–207.PubMedCrossRef
18.
Zurück zum Zitat Gross AE, Goodman S. The current role of structural grafts and cages in revision arthroplasty of the hip. Clin Orthop Relat Res. 2004;429:193–200.PubMedCrossRef Gross AE, Goodman S. The current role of structural grafts and cages in revision arthroplasty of the hip. Clin Orthop Relat Res. 2004;429:193–200.PubMedCrossRef
19.
Zurück zum Zitat Gustke KA, Levering MF, Miranda MA. Use of jumbo cups for revision of acetabulae with large bony defects. J Arthroplasty. 2013;29:199–203.PubMedCrossRef Gustke KA, Levering MF, Miranda MA. Use of jumbo cups for revision of acetabulae with large bony defects. J Arthroplasty. 2013;29:199–203.PubMedCrossRef
20.
Zurück zum Zitat Judge A, Arden NK, Batra RN, Thomas G, Beard D, Javaid MK, Cooper C, Murray DW, Exeter Primary Outcomes Study (EPOS) group. The association of patient characteristics and surgical variables on symptoms of pain and function over 5 years following primary hip-replacement surgery: a prospective cohort study. BMJ Open. 2013;3:e002453. Judge A, Arden NK, Batra RN, Thomas G, Beard D, Javaid MK, Cooper C, Murray DW, Exeter Primary Outcomes Study (EPOS) group. The association of patient characteristics and surgical variables on symptoms of pain and function over 5 years following primary hip-replacement surgery: a prospective cohort study. BMJ Open. 2013;3:e002453.
21.
Zurück zum Zitat Kim D-H, Cho S-H, Jeong S-T, Park H-B, Hwang S-C, Park J-S. Restoration of the center of rotation in revision total hip arthroplasty. J Arthroplasty. 2010;25:1041–1046.PubMedCrossRef Kim D-H, Cho S-H, Jeong S-T, Park H-B, Hwang S-C, Park J-S. Restoration of the center of rotation in revision total hip arthroplasty. J Arthroplasty. 2010;25:1041–1046.PubMedCrossRef
22.
Zurück zum Zitat Lee PTH, Raz G, Safir OA, Backstein DJ, Gross AE. Long-term results for minor column allografts in revision hip arthroplasty. Clin Orthop Relat Res. 2010;468:3295–3303.PubMedCentralPubMedCrossRef Lee PTH, Raz G, Safir OA, Backstein DJ, Gross AE. Long-term results for minor column allografts in revision hip arthroplasty. Clin Orthop Relat Res. 2010;468:3295–3303.PubMedCentralPubMedCrossRef
23.
Zurück zum Zitat Moore MS, McAuley JP, Young AM, Engh CA Sr. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–183.PubMedCrossRef Moore MS, McAuley JP, Young AM, Engh CA Sr. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–183.PubMedCrossRef
24.
Zurück zum Zitat Paprosky WG, Magnus RE. Principles of bone grafting in revision total hip arthroplasty. Acetabular technique. Clin Orthop Relat Res. 1994;298:147–155. Paprosky WG, Magnus RE. Principles of bone grafting in revision total hip arthroplasty. Acetabular technique. Clin Orthop Relat Res. 1994;298:147–155.
25.
Zurück zum Zitat Paprosky WG, Martin EL. Structural acetabular allograft in revision total hip arthroplasty. Am J Orthop. 2002;31:481–484.PubMed Paprosky WG, Martin EL. Structural acetabular allograft in revision total hip arthroplasty. Am J Orthop. 2002;31:481–484.PubMed
26.
Zurück zum Zitat Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994;9:33–44.PubMedCrossRef Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994;9:33–44.PubMedCrossRef
27.
Zurück zum Zitat Patel JV, Masonis JL, Bourne RB, Rorabeck CH. The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty. 2003;18:129–133.PubMedCrossRef Patel JV, Masonis JL, Bourne RB, Rorabeck CH. The fate of cementless jumbo cups in revision hip arthroplasty. J Arthroplasty. 2003;18:129–133.PubMedCrossRef
28.
Zurück zum Zitat Russotti GM, Harris WH. Proximal placement of the acetabular component in total hip-arthroplasty—a long-term follow-up-study. J Bone Joint Surg Am. 1991;73:587–592.PubMed Russotti GM, Harris WH. Proximal placement of the acetabular component in total hip-arthroplasty—a long-term follow-up-study. J Bone Joint Surg Am. 1991;73:587–592.PubMed
29.
Zurück zum Zitat Saleh KJ, Holtzman J, Gafni ASaleh L, Jaroszynski G, Wong P, Woodgate I, Davis A, Gross AE. Development, test reliability and validation of a classification for revision hip arthroplasty. J Orthop Res. 2001;19:50–56. Saleh KJ, Holtzman J, Gafni ASaleh L, Jaroszynski G, Wong P, Woodgate I, Davis A, Gross AE. Development, test reliability and validation of a classification for revision hip arthroplasty. J Orthop Res. 2001;19:50–56.
30.
Zurück zum Zitat Schreurs BW, Keurentjes JC, Gardeniers JWM, Verdonschot N, Slooff TJ, Veth RPH. Acetabular revision with impacted morsellised cancellous bone grafting and a cemented acetabular component: a 20- to 25-year follow-up. J Bone Joint Surg Br. 2009;91:1148–1153.PubMedCrossRef Schreurs BW, Keurentjes JC, Gardeniers JWM, Verdonschot N, Slooff TJ, Veth RPH. Acetabular revision with impacted morsellised cancellous bone grafting and a cemented acetabular component: a 20- to 25-year follow-up. J Bone Joint Surg Br. 2009;91:1148–1153.PubMedCrossRef
31.
Zurück zum Zitat Schreurs BW, Luttjeboer J, Thien TM, de Waal Malefijt MC, Buma P, Veth RPH, Slooff TJ. Acetabular revision with impacted morsellized cancellous bone graft and a cemented cup in patients with rheumatoid arthritis. A concise follow-up, at eight to nineteen years, of a previous report. J Bone Joint Surg Am. 2009;91:646–651. Schreurs BW, Luttjeboer J, Thien TM, de Waal Malefijt MC, Buma P, Veth RPH, Slooff TJ. Acetabular revision with impacted morsellized cancellous bone graft and a cemented cup in patients with rheumatoid arthritis. A concise follow-up, at eight to nineteen years, of a previous report. J Bone Joint Surg Am. 2009;91:646–651.
32.
Zurück zum Zitat Shinar AA, Harris WH. Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty. Sixteen-year-average follow-up. J Bone Joint Surg Am. 1997;79:159–168.PubMed Shinar AA, Harris WH. Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty. Sixteen-year-average follow-up. J Bone Joint Surg Am. 1997;79:159–168.PubMed
33.
Zurück zum Zitat Siegmeth A, Duncan CP, Masri BA, Kim WY, Garbuz DS. Modular tantalum augments for acetabular defects in revision hip arthroplasty. Clin Orthop Relat Res. 2009;467:199–205.PubMedCentralPubMedCrossRef Siegmeth A, Duncan CP, Masri BA, Kim WY, Garbuz DS. Modular tantalum augments for acetabular defects in revision hip arthroplasty. Clin Orthop Relat Res. 2009;467:199–205.PubMedCentralPubMedCrossRef
34.
Zurück zum Zitat Slooff TJ, Buma P, Schreurs BW, Schimmel JW, Huiskes R, Gardeniers J. Acetabular and femoral reconstruction with impacted graft and cement. Clin Orthop Relat Res. 1996;324:108–115.PubMedCrossRef Slooff TJ, Buma P, Schreurs BW, Schimmel JW, Huiskes R, Gardeniers J. Acetabular and femoral reconstruction with impacted graft and cement. Clin Orthop Relat Res. 1996;324:108–115.PubMedCrossRef
35.
Zurück zum Zitat Sporer SM, Paprosky WG. The use of a trabecular metal acetabular component and trabecular metal augment for severe acetabular defects. J Arthroplasty. 2006;21:83–86.PubMedCrossRef Sporer SM, Paprosky WG. The use of a trabecular metal acetabular component and trabecular metal augment for severe acetabular defects. J Arthroplasty. 2006;21:83–86.PubMedCrossRef
36.
Zurück zum Zitat Sporer SM, Paprosky WG. Acetabular revision using a trabecular metal acetabular component for severe acetabular bone loss associated with a pelvic discontinuity. J Arthroplasty. 2006;21:87–90.PubMedCrossRef Sporer SM, Paprosky WG. Acetabular revision using a trabecular metal acetabular component for severe acetabular bone loss associated with a pelvic discontinuity. J Arthroplasty. 2006;21:87–90.PubMedCrossRef
37.
Zurück zum Zitat Templeton JE, Callaghan J, Goetz D, Sullivan PM, Johnston R. Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study. J Bone Joint Surg Am. 2001;83:1706–1711.PubMed Templeton JE, Callaghan J, Goetz D, Sullivan PM, Johnston R. Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study. J Bone Joint Surg Am. 2001;83:1706–1711.PubMed
39.
Zurück zum Zitat Ware J, Kosinski M, Keller SD. A 12-Item Short-Form Health Survey: construction of scales and preliminary tests of reliability and validity. Med Care. 1996;34:220–233.PubMedCrossRef Ware J, Kosinski M, Keller SD. A 12-Item Short-Form Health Survey: construction of scales and preliminary tests of reliability and validity. Med Care. 1996;34:220–233.PubMedCrossRef
40.
Zurück zum Zitat Whaley AL, Berry DJ, Harmsen WS. Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Joint Surg Am. 2001;83:1352–1357.PubMed Whaley AL, Berry DJ, Harmsen WS. Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Joint Surg Am. 2001;83:1352–1357.PubMed
41.
Zurück zum Zitat Williams DH, Greidanus NV, Masri BA, Duncan CP, Garbuz DS. Predictors of participation in sports after hip and knee arthroplasty. Clin Orthop Relat Res. 2011;470:555–561.PubMedCentralCrossRef Williams DH, Greidanus NV, Masri BA, Duncan CP, Garbuz DS. Predictors of participation in sports after hip and knee arthroplasty. Clin Orthop Relat Res. 2011;470:555–561.PubMedCentralCrossRef
42.
Zurück zum Zitat Woodgate IG, Saleh KJ, Jaroszynski G, Agnidis Z, Woodgate MM, Gross AE. Minor column structural acetabular allografts in revision hip arthroplasty. Clin Orthop Relat Res. 2000;371:75–85.PubMedCrossRef Woodgate IG, Saleh KJ, Jaroszynski G, Agnidis Z, Woodgate MM, Gross AE. Minor column structural acetabular allografts in revision hip arthroplasty. Clin Orthop Relat Res. 2000;371:75–85.PubMedCrossRef
Metadaten
Titel
Continued Good Results With Modular Trabecular Metal Augments for Acetabular Defects in Hip Arthroplasty at 7 to 11 Years
verfasst von
Michael R. Whitehouse, PhD, MSc(Orth Eng), FRCS(Tr&Orth)
Bassam A. Masri, MD, FRCS(C)
Clive P. Duncan, MD, MSc
Donald S. Garbuz, MD, MHSc
Publikationsdatum
01.02.2015
Verlag
Springer US
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 2/2015
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-014-3861-x

Weitere Artikel der Ausgabe 2/2015

Clinical Orthopaedics and Related Research® 2/2015 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.