Skip to main content
Erschienen in: Journal of Clinical Monitoring and Computing 6/2015

01.12.2015 | Original Research

Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients

verfasst von: Julia Y. Wagner, Ileana Negulescu, Miriam Schöfthaler, Alexander Hapfelmeier, Agnes S. Meidert, Wolfgang Huber, Roland M. Schmid, Bernd Saugel

Erschienen in: Journal of Clinical Monitoring and Computing | Ausgabe 6/2015

Einloggen, um Zugang zu erhalten

Abstract

The CNAP system allows continuous noninvasive arterial pressure measurement based on the volume clamp method using a finger cuff. We aimed to evaluate the agreement between arterial pressure measurements noninvasively obtained using the CNAP device and arterial catheter-derived arterial pressure measurements in intensive care unit patients. In 55 intensive care unit patients, we simultaneously recorded arterial pressure values obtained by an arterial catheter placed in the abdominal aorta through the femoral artery (criterion standard) and arterial pressure values determined noninvasively using CNAP. We performed Bland–Altman analysis and calculated the percentage error. The mean difference (±standard deviation, 95 % limits of agreement, percentage error) between noninvasive (CNAP) and invasively assessed arterial pressure was for mean arterial pressure +1 mmHg (±9 mmHg, −16 to +19 mmHg, 22 %), for systolic arterial pressure −10 mmHg (±16 mmHg, −42 to +21 mmHg, 27 %), and for diastolic arterial pressure +7 mmHg (±9 mmHg, −10 to +24 mmHg, 28 %). Our results indicate a reasonable accuracy and precision for the determination of mean and diastolic arterial pressure by noninvasive continuous arterial pressure measurements using the volume clamp method compared with the criterion standard (invasive arterial catheter). Systolic arterial pressure is determined less accurately and precisely.
Literatur
1.
Zurück zum Zitat Frezza EE, Mezghebe H. Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients. Am Surg. 1998;64:127–31.PubMed Frezza EE, Mezghebe H. Indications and complications of arterial catheter use in surgical or medical intensive care units: analysis of 4932 patients. Am Surg. 1998;64:127–31.PubMed
2.
Zurück zum Zitat O’Grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, Lipsett PA, Masur H, Mermel LA, Pearson ML, Raad II, Randolph AG, Rupp ME, Saint S, Healthcare Infection Control Practices Advisory C. Guidelines for the prevention of intravascular catheter-related infections. Am J Infect Control. 2011;39:S1–34.CrossRefPubMed O’Grady NP, Alexander M, Burns LA, Dellinger EP, Garland J, Heard SO, Lipsett PA, Masur H, Mermel LA, Pearson ML, Raad II, Randolph AG, Rupp ME, Saint S, Healthcare Infection Control Practices Advisory C. Guidelines for the prevention of intravascular catheter-related infections. Am J Infect Control. 2011;39:S1–34.CrossRefPubMed
3.
Zurück zum Zitat Penaz J, Voigt A, Teichmann W. Contribution to the continuous indirect blood pressure measurement. Z Gesamte Inn Med. 1976;31:1030–3.PubMed Penaz J, Voigt A, Teichmann W. Contribution to the continuous indirect blood pressure measurement. Z Gesamte Inn Med. 1976;31:1030–3.PubMed
4.
Zurück zum Zitat Fortin J, Marte W, Grullenberger R, Hacker A, Habenbacher W, Heller A, Wagner C, Wach P, Skrabal F. Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med. 2006;36:941–57.CrossRefPubMed Fortin J, Marte W, Grullenberger R, Hacker A, Habenbacher W, Heller A, Wagner C, Wach P, Skrabal F. Continuous non-invasive blood pressure monitoring using concentrically interlocking control loops. Comput Biol Med. 2006;36:941–57.CrossRefPubMed
5.
Zurück zum Zitat Biais M, Vidil L, Roullet S, Masson F, Quinart A, Revel P, Sztark F. Continuous non-invasive arterial pressure measurement: evaluation of CNAP device during vascular surgery. Ann Fr Anesth Reanim. 2010;29:530–5.CrossRefPubMed Biais M, Vidil L, Roullet S, Masson F, Quinart A, Revel P, Sztark F. Continuous non-invasive arterial pressure measurement: evaluation of CNAP device during vascular surgery. Ann Fr Anesth Reanim. 2010;29:530–5.CrossRefPubMed
6.
Zurück zum Zitat Jeleazcov C, Krajinovic L, Munster T, Birkholz T, Fried R, Schuttler J, Fechner J. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br J Anaesth. 2010;105:264–72.CrossRefPubMed Jeleazcov C, Krajinovic L, Munster T, Birkholz T, Fried R, Schuttler J, Fechner J. Precision and accuracy of a new device (CNAPTM) for continuous non-invasive arterial pressure monitoring: assessment during general anaesthesia. Br J Anaesth. 2010;105:264–72.CrossRefPubMed
7.
Zurück zum Zitat Jagadeesh AM, Singh NG, Mahankali S. A comparison of a continuous noninvasive arterial pressure (CNAP) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU. Ann Card Anaesth. 2012;15:180–4.CrossRefPubMed Jagadeesh AM, Singh NG, Mahankali S. A comparison of a continuous noninvasive arterial pressure (CNAP) monitor with an invasive arterial blood pressure monitor in the cardiac surgical ICU. Ann Card Anaesth. 2012;15:180–4.CrossRefPubMed
8.
Zurück zum Zitat Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed Bland JM, Altman DG. Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat. 2007;17:571–82.CrossRefPubMed
9.
Zurück zum Zitat Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed Critchley LA, Critchley JA. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput. 1999;15:85–91.CrossRefPubMed
10.
Zurück zum Zitat Martina JR, Westerhof BE, van Goudoever J, de Beaumont EM, Truijen J, Kim YS, Immink RV, Jobsis DA, Hollmann MW, Lahpor JR, de Mol BA, van Lieshout JJ. Noninvasive continuous arterial blood pressure monitoring with Nexfin(R). Anesthesiology. 2012;116:1092–103.CrossRefPubMed Martina JR, Westerhof BE, van Goudoever J, de Beaumont EM, Truijen J, Kim YS, Immink RV, Jobsis DA, Hollmann MW, Lahpor JR, de Mol BA, van Lieshout JJ. Noninvasive continuous arterial blood pressure monitoring with Nexfin(R). Anesthesiology. 2012;116:1092–103.CrossRefPubMed
11.
Zurück zum Zitat Meidert AS, Huber W, Muller JN, Schofthaler M, Hapfelmeier A, Langwieser N, Wagner JY, Eyer F, Schmid RM, Saugel B. Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure. Br J Anaesth. 2014;112:521–8.CrossRefPubMed Meidert AS, Huber W, Muller JN, Schofthaler M, Hapfelmeier A, Langwieser N, Wagner JY, Eyer F, Schmid RM, Saugel B. Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure. Br J Anaesth. 2014;112:521–8.CrossRefPubMed
12.
Zurück zum Zitat Hahn R, Rinosl H, Neuner M, Kettner SC. Clinical validation of a continuous non-invasive haemodynamic monitor (CNAP™ 500) during general anaesthesia. Br J Anaesth. 2012;108:581–5.CrossRefPubMed Hahn R, Rinosl H, Neuner M, Kettner SC. Clinical validation of a continuous non-invasive haemodynamic monitor (CNAP™ 500) during general anaesthesia. Br J Anaesth. 2012;108:581–5.CrossRefPubMed
13.
Zurück zum Zitat Ilies C, Bauer M, Berg P, Rosenberg J, Hedderich J, Bein B, Hinz J, Hanss R. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth. 2012;108:202–10.CrossRefPubMed Ilies C, Bauer M, Berg P, Rosenberg J, Hedderich J, Bein B, Hinz J, Hanss R. Investigation of the agreement of a continuous non-invasive arterial pressure device in comparison with invasive radial artery measurement. Br J Anaesth. 2012;108:202–10.CrossRefPubMed
14.
Zurück zum Zitat Gayat E, Mongardon N, Tuil O, Sievert K, Chazot T, Liu N, Fischler M. CNAP(®) does not reliably detect minimal or maximal arterial blood pressures during induction of anaesthesia and tracheal intubation. Acta Anaesthesiol Scand. 2013;57:468–73.CrossRefPubMed Gayat E, Mongardon N, Tuil O, Sievert K, Chazot T, Liu N, Fischler M. CNAP(®) does not reliably detect minimal or maximal arterial blood pressures during induction of anaesthesia and tracheal intubation. Acta Anaesthesiol Scand. 2013;57:468–73.CrossRefPubMed
15.
Zurück zum Zitat Saugel B, Fassio F, Hapfelmeier A, Meidert AS, Schmid RM, Huber W. The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients. Intensive Care Med. 2012;38:1471–7.CrossRefPubMed Saugel B, Fassio F, Hapfelmeier A, Meidert AS, Schmid RM, Huber W. The T-Line TL-200 system for continuous non-invasive blood pressure measurement in medical intensive care unit patients. Intensive Care Med. 2012;38:1471–7.CrossRefPubMed
16.
Zurück zum Zitat ANSI/AAMI SP10:2002. American national standard for manual electronic, or automated sphygmomanometers. Association for the Advancement of Medical Instrumentation, 2002. ANSI/AAMI SP10:2002. American national standard for manual electronic, or automated sphygmomanometers. Association for the Advancement of Medical Instrumentation, 2002.
17.
Zurück zum Zitat Saugel B, Reuter DA. Are we ready for the age of non-invasive haemodynamic monitoring? Br J Anaesth. 2014;113:340–3.CrossRefPubMed Saugel B, Reuter DA. Are we ready for the age of non-invasive haemodynamic monitoring? Br J Anaesth. 2014;113:340–3.CrossRefPubMed
18.
Zurück zum Zitat O’Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, Mengden T, Imai Y, Waeber B, Palatini P, Gerin W, Working Group on Blood Pressure Monitoring of the European Society of H. Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit. 2002;7:3–17.CrossRefPubMed O’Brien E, Pickering T, Asmar R, Myers M, Parati G, Staessen J, Mengden T, Imai Y, Waeber B, Palatini P, Gerin W, Working Group on Blood Pressure Monitoring of the European Society of H. Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults. Blood Press Monit. 2002;7:3–17.CrossRefPubMed
19.
Zurück zum Zitat Saugel B, Dueck R, Wagner JY. Measurement of blood pressure. Best Pract Res Clin Anaesthesiol. 2014;28:309–22.CrossRefPubMed Saugel B, Dueck R, Wagner JY. Measurement of blood pressure. Best Pract Res Clin Anaesthesiol. 2014;28:309–22.CrossRefPubMed
20.
Zurück zum Zitat Wagner JY, Saugel B. When should we adopt continuous noninvasive hemodynamic monitoring technologies into clinical routine? J Clin Monit Comput. 2014;29:1–3.CrossRef Wagner JY, Saugel B. When should we adopt continuous noninvasive hemodynamic monitoring technologies into clinical routine? J Clin Monit Comput. 2014;29:1–3.CrossRef
Metadaten
Titel
Continuous noninvasive arterial pressure measurement using the volume clamp method: an evaluation of the CNAP device in intensive care unit patients
verfasst von
Julia Y. Wagner
Ileana Negulescu
Miriam Schöfthaler
Alexander Hapfelmeier
Agnes S. Meidert
Wolfgang Huber
Roland M. Schmid
Bernd Saugel
Publikationsdatum
01.12.2015
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 6/2015
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9670-2

Weitere Artikel der Ausgabe 6/2015

Journal of Clinical Monitoring and Computing 6/2015 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.